Repairs Maintenance Of Summer Appliances And Its Allied Works Under Ge Chennai Repairs Maintenance Of Summer Appliances And Its Allied Works Under Ge Chennai, Fort Saint George, Chennai-Tamil Nadu

Military Engineer Services-MES has published Repairs Maintenance Of Summer Appliances And Its Allied Works Under Ge Chennai Repairs Maintenance Of Summer Appliances And Its Allied Works Under Ge Chennai. Submission Date for this Tender is 27-08-2021. Air Conditioner Tenders in Fort Saint George, Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

28701426
Corrigendum : Repairs Maintenance Of Summer Appliances And Its Allied Works Under Ge Chennai Repairs Maintenance Of Summer Appliances And Its Allied Works Under Ge Chennai
Open Tender
Indian
Tamil Nadu
Fort Saint George, Chennai
27-08-2021

Tender Details

Repairs Maintenance Of Summer Appliances And Its Allied Works Under Ge Chennai Repairs Maintenance Of Summer Appliances And Its Allied Works Under Ge Chennai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Aug-2021 Corrigendum1 BOQ 20-08-2021
2 20-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIRS/ MAINTENANCE OF SUMMER APPLIANCES AND ITS ALLIED WORKS UNDER GE CHENNAI
Sl. No. Item Description
1BOQ PUBLISHED ON 30 JUL 2021
2Taking down carefully, dismantling and opening the water coolers/ deep Freezers of any capacity/ any make after disconnecting the electric connection for attending repairs, reassembling, refixing and re-connecting the Water coolers/ Deep Freezers to power point/ connector after necessary servicing and replacing the spare parts etc., complete all as specified and directed. Note: (i) Servicing and replacing the spare parts shall be measured and paid separetely. (ii) In specific cases involving shifting to workshop and returning to work site, the same will be measured and paid separetely.
3Rewinding the blower fan motor of water coolers of any Make with super enamelled copper wire of same existing (original) size to get design speed for the particular make of fan motor including insulating varnishing, providing sleeves to copper wire ends all as specified and directed for the capacity of fan motor 1/5 HP (for 150 litres water cooler).
4All as per item No. 2.00 above but, fan motor 1/16 HP (for 120 litres water cooler)
5All as per item No. 2.00 above but, fan motor 1/32 HP (for 80 litres water cooler)
6Flushing complete condensing unit, cooling coil unit and replacement of liquid lines, strainer/ drier capillary tubes etc. and rectification of leakage from the system, vacumising, dehydrating oil and gas charging including testing and commissioning complete and all as specified and directed for the water cooler of capacity 150 litres. Make of Water Cooler: USHA SHRIRAM/ BLUE STAR. Note:Freon Gas for charging shall be measured and paid separately.
7All as per item No. 5.00 above but, water cooler of capacity 120 Litres
8All as per item No. 5.00 above but, water cooler of capacity 80 Litres
9All as per item No. 5.00 above but, Deep freezer of capacity 200/ 585 Litres
10M&L for scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint over a coat of red oxide primer to water cooler complete and all as directed for the water cooler of capacity 150 litres. MAKE: USHA SHRIRAM/ BLUE STAR/ VOLTAS/ SIDWAL
11All as per item No. 9.00 above but, water cooler 120 Litres capacity.
12All as per item No. 9.00 above but, water cooler 80 Litres capacity.
13M&L for removal of entire portion of corroded base plate complete and welding with new base plate of same original gauge of MS Sheet, angle iron legs and painting with two coats of synthetic enamel paint over a coat of red oxide primer to match with existing surface for water coolers of any capacity complete all as directed.
14Repairs to the corroded portion of the water cooler side, front and rear panels, drip tray, top lid and making good by welding with MS sheet of 20 guageand painting with two coats of synthetic enamel paint over a coat of red oxide primer to match with existing surface complete all as directed.
15Supply only top lid hinges (set of two Nos counted as one unit)
16Supply only top lid gasket
17Supply only ball brass valve with polythene float and fly nut 1/2" (15mm) size .
18Supply only brass chromium plated 15mm dia push tap.Make: JAQUAR/ PRAYAG/ PARRYWARE/ H&R JOHNSON.
19Supply onlyfan motor blades suitable for 1/5 HP/ 1/6 HP/1/32 HP fan motors for water coolers. Make of fan motor: Usha Shriram/ Blue star/ Voltas/ Sidwal
20Supply only compressor unit mounting rubber bush complete with spring plate (02 Nos counted as one unit) for water coolers.
21Supply only fan motor capacitor 4 mFd for water coolers. Make: USHA/ KELTRON/ RENUTROL/ EPCOS.
22Supply only Thermostat switch for water coolers. Make: Danfoss/ Infoss
23Supply only Terminal cover with clamps for water coolers.
24Supply only Three core 4 Sqmm PVC insulated copper wire. Make: Finolex/ Havells/ Polycab/ Gloster/ Universal.
25Supply only Over load protector for SR 522/ SR 1022 for water coolers of capacity 150/ 120/ 80 litres. Make: Usha Sriram/ Renutrol/ Keltron
26Supply only Starting capacitor 40-80 mFd for water coolers of capacity 150/120/80 litres. Make: USHA/ KELTRON/ RENUTROL/ EPCOS.
27Supply only running capacitor 15-30mFd for water coolers of capacity 150/ 120/ 80 litres. Make: USHA/ KELTRON/ RENUTROL/ EPCOS.
28Supply only Starting relay for compressor for water coolers of capacity 150/ 120/ 80 litres. Make: Usha sriram/ Renutrol/ Keltron
29Taking out the existing unserviceable compressor unit and supply & fix new compressor unit of same make of water cooler suitable for the capacity of water cooler 80 litres including testing and commissioning etc. complete all as directed. Make of Water cooler: Usha shriram/ Bluestar/ Voltas/ Sidwal. Note : Freon Gas shall be measured and paid separately.
30All as per item No. 28.00 above, but for Water cooler 120 Litre capacity.
31All as per item No. 28.00 above, but for Water cooler 150 Litre capacity.
32Taking down unserviceable fan motor from water cooler and supply & fix new fan motor factory made for the capacity 1/16 HP (for 150 litres water cooler/ deep freezers) conforming to IS specification and bearing ISI mark all as specified and directed. Make: AUE/ GEC.
33All as per item No. 31.00 above but for Fan motor 1/32 HP (for 120/ 80 litrs water coolers).
34All as per item No. 31.00 above but for Fan motor 1/32 HP (for deep freezer).
35Taking down water cooler from site and shifting to workshop for repairs and brought back to same site and re-fixing the same in position all as directed. Note: Repair will be measured and paid separately.
36Dismantling the fan motor from the refrigerator, taking out the burnt out winding and Rewinding the blower fan motor of Refrigerator of capacity 180/ 270/ 310/ 315/ 344 litres of any make with super enamelled copper wire of same existing (original) size to get design speed for the particular make of fan motor including insulating varnishing, providing sleeves to copper wire ends and refixing the same in its original position, testing and commissioning all as specified and directed.
37Flushing complete condensing unit, cooling coil unit and replacement of liquid lines, strainer/ drier capillary tubes etc, of refrigerators and rectification of leakage from the system, vacumising dehydrating oil and gas charging including testing and commissioning complete and all as directed for the refrigerators capacity 180/ 270/ 310/ 315/ 344 litres. Note: Freon Gas for charging shall be measured and paid separately.
38M&L for renewal of entire portion of corroded base plate complete and welding with new base plate of existing gauge of MS Sheet and painting with two coats of synthetic enamel paint over a coat of red oxide primer to match with existing surface for refrigerators of capacity 180/ 270 litres of any make.
39All as per item No. 37.00 above but, for 310/ 315/ 344 litres capacity of any make.
40Scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint over a coat of red oxide primer for capacity ofthe refrigerators 165/ 200 litres capacity of any make.
41All as per item No. 39.00 above but, for 286/ 315/ 344 litres capacity of any make.
42M&L for replacement of cabinet light switch for refrigerators of any make and capacity.
43M&L for replacement of cabinet light bulbsfor refrigerators of any make and capacity.
44M&L for replacement of mounting rubber bush for compressor (3 Nos counted as one unit)
45M&L for replacement of auto defrost type thermostat switch for refrigerator of any capacity.
46M&L for replacement of starting relay pin type
47M&L for replacement of overload protector 1/8 HP/ 1/6 HP
48M&L for replacement of BI metal relay for refrigerator of any capacity.
49M&L for replacement of timer switch for refrigerator of any capacity.
50M&L for replacement of leg pin/ screw type for refrigerators (4 Nos one set). Make for item Nos. 41.00 to 49.00: Suitable make of exisiting refrigerator.
51M&L PVC insulated and sheathed multistranded three core cable with copper conductor of 48 strands fixed in replacement all as specified and directed. Make: Finolex/ Havells/ Plaza/ Standard.
52M&L for replacement of magnetic door gasket for refrigerators of capacity 180/ 270 litres of make Kelvinator/ LG/ Whirlpool/ Samsung/ Voltas all as directed.
53M&L for replacement of shelves set for refrigerators of capacity 180/ 270 litres of make Kelvinator/ LG/ Whirlpool/ Samsung/ Voltas all as directed.
54M&L for replacement of vegetable tray with glass cover for refrigerators of capacity 180/ 270 litres of make Kelvinator/ LG/ Whirlpool/ Samsung/ Voltas all as directed.
55M&L for replacement of freezer door for refrigerators of capacity 180/ 270 litres of make Kelvinator/ LG/ Whirlpool/ Samsung/ Voltas all as directed.
56M&L for replacement of ice tray for refrigerators of capacity 180/ 270 litres of make Kelvinator/ LG/ Whirlpool/ Samsung/ Voltas all as directed. Note for item No. 51 to 55: Spare shall be of same make of refrigerator and shall conforming to IS specification.
57M&L for replacement of magnetic door gasket for refrigerators of capacity 310/ 315/ 344 litres of make Kelvinator/ LG/ Wirlpool/ Samsung/ Voltas all as directed.
58M&L for replacement of shelves set for refrigerators of capacity 310/ 315/ 344 litres of make Kelvinator/ LG/ Wirlpool/ Samsung/ Voltas all as directed.
59M&L for replacement of ice tray for refrigerators of capacity 310/ 315/ 344 litres of make Kelvinator/ LG/ Wirlpool/ Samsung/ Voltas all as directed.
60M&L for replacement of vegetable tray with glass cover for refrigerators of capacity 310/ 315/ 344 litres of make Kelvinator/ LG/ Wirlpool/ Samsung/ Voltas all as directed.
61M&L for replacement of freezer door for refrigerators of capacity 310/ 315/ 344 litres of make Kelvinator/ LG/ Wirlpool/ Samsung/ Voltas all as directed. Note for item No. 56.00 to 60.00: Spare shall be of same make of refrigerator and shall conforming to IS specification.
62Taking out the existing unserviceable compressor unit and supply & fix new compressor unit of same make as that of refrigerator suitable for 180/ 270 litres refrigerators including testing and commisioning etc. complete all as directed. Note: Supply only of Freon gas charging shall be measured and paid for separately.
63Taking out the existing unserviceable compressor unit and supply & fix new compressor unit of same make as that of refrigerator suitable for 310/ 315/ 344 litres refrigerators including testing and commisioning etc. complete all as directed. Note: Supply only of Freon gas charging shall be measured and paid for separately.
64Supply only Freon Gas R-134A for charging to refrigerator/ water cooler/ deep freezers.
65Dismantling the fan motor from the window type AC of capacity 1.5 Ton of any make, taking out the burnt out winding and rewinding the motor with super enamelled copper wire of existing gauge to get designed speed including insulating, varnishing, providing sleeves to copper wire ends and refixing the same on its original position, testing and commissioning all as specified and directed.
66Flushing complete condensing unit, evaporator coil unit, compressor suction and delivery tubes and replacement of charging lines, strainers capillary tube etc., of window type AC and rectification of the leakage from the system, vaccumising, dehydrating, oil and gas charging including testing and commissioning of system all as directed. Note: Supply only of Freon gas for charging shall be measured and paid separately.
67M&L for replacement of condensing coil and housing of the unit of any make ofwindow type AC all as sapecified and directed.
68M&L for replacement of cooling coil unit and housing the unit of any make of window type AC all as specified and directed.
69M&L for renewal of corroded base plate by welding new MS sheet of gauge as existing (original) and painting with two coats of synthetic enamel paint over a coat of red oxide primer to match with existing surface for window type AC complete all as specified and directed.
70All as per item No. 68.00 above but Cooling coil housing, side and top plate.
71All as per item No. 68.00 above but Fan motor base.
72All as per item No. 68.00 above but Condensor coil housing side and top plate.
73M&L for replacement of evaporator coil for the 1.5 ton capacity window type air conditioners of any make all as directed. Note: The spares shall be of same make as that of AC (or) of existing spare and shall conforming to IS specification
74All as per item No. 72.00 above but Condensor coil
75All as per item No. 72.00 above but Standard outer cover.
76All as per item No. 72.00 above but Front grill.
77All as per item No. 72.00 above but Fan blade with squirel
78All as per item No. 72.00 above but Fan motor 1/5 HP
79All as per item No. 72.00 above but Rubber bush andMS clamp with bolts & nuts for motor
80All as per item No. 72.00 above but Starting relay 1622.
81All as per item No. 72.00 above but Starting capacitor 80-100 mFd.
82All as per item No. 72.00 above but running capacitor suitable mfd for the driven machine.
83All as per item No. 72.00 above but fan motor capacitor 4/6 mFd.
84All as per item No. 72.00 above but Thermostat switch
85M&L multi stranded 4 sqmm three core wire PVC insulated sheathed with copper conductor for window type AC all as specified and directed. Make: Finolex/ Havells/ Plaza/ Standard
86M&L for replacement of compressor terminal cover with clamp for window type AC all as directed.
87M&L for replacement of compressor mounting rubber bush for window type AC all as directed. (set of 3 Nos counted as one unit).
88M&L for replacement of remote control with PCB for window type AC all as directed.
89S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20 Amps for incoming and out going control complete all as specified and directed. Make: Standard/ Havells/ Seimens/ L&T.
90M&L for cleaningthe evaporator and condenser unit assembly of window type air conditioners with castic soda wash including scraping, removal of rust and complete removal of existing painting and applying spray painting with two coats of synthetic enamel paint over a coat of red oxide primer completev all as directed.
91Taking out the existing unserviceable compressor unit from window type AC and supply & fix new hermetically sealed rotary/ piston type compressor unit of capacity 1.5 ton and of same make as that of window type AC suitableto operate in AC single phase 50 HZ 230 volts including testing and commisioning etc., complete all as specified and directed. Note: Freon gas for charging shall be measured and paid for separately.
92Taking out the existing unserviceable compressor unit from Split type AC and supply & fix new hermetically sealed rotary/ piston type compressor unit of capacity 1.5 & 2.0 ton of same make as that of Split type AC suitable to operate in AC single phase 50 HZ 230 volts for split type AC including testing and commisioning etc. complete all as specified and directed. Note: Freon Gas for charging shall be measured and paid separately.
93Flushing the complete condensing unit, evaporator coil unit, compressor suction and delivery tubes and replacement of charging lines, strainers capillary tube etc. of split type AC and rectification of the leakage from the system, vaccumising. dehydrating as per standard practice and gas charging including testing and commissioning of system complete all as directed. Note: Freon gas for charging shall be measured and paid separately.
94M&L for replacement of fan motor of 1/6 HP RPM 950 AC single phase 50 HZ evaporator coil for the split type air conditioners of any make complete all as directed. Note: The spares shall be of same make of AC (or) of existing spare and shall conforming to IS specifications.
95All as per item No. 93.00 above but Freon gas outlet control regulator.
96All as per item No. 93.00 above but Freon gas inlet control regulator.
97All as per item No. 93.00 above but compressor base plate.
98All as per item No. 93.00 above but Condensor coil/ Evaparator coil (or) cooling coil.
99All as per item No. 93.00 above but Hand smart remote control with PCB.
100All as per item No. 93.00 above but Fan motor for condensing unit (outdoor unit).
101Dismantling Voltage stablizer of any make and of capacity 5 KVA and transporting to workshop to detect/ identifythe nature of defects/ repairs and reassembling and refixing after repairs/ servicing including testing and commissioning etc. complete all as specified and directed.
102All as per item No. 100.00 above but 4 KVA.
103Dismantling/ taking down transformer from 5 KVAstablizer, removing the burnt out winding and rewinding the transformer with super enameled copper wire of size as per existing (original) including insulating, varnishing and providing sleeves etc. and refixing in the stablizers in original position complete all as specified and directed.
104All as per item No. 102.00 above but 4 KVA.
105Removing the transformer from stablizerof capacity 5 KVA, cleaning varnishing with shellac including replacement of insulating sleeves etc. and refixing in the stablizer in original position complete all as specified and directed. Note: Replacement of insulating parts /defective items will be measured and paid separately.
106All as per item No. 104.00 above but 4 KVA.
107Supply only Relay set (set of two) for voltage stabilizer of capacity upto 5 KVA all as directed.
108Supply only PCB (Printed circuit board) for voltage stabilizer of capacity upto 5 KVA all as directed.
109Supply only Three core wire for voltage stabilizer of capacity upto 5 KVA all as directed.
110Supply only Indicating lamp for voltage stabilizer of capacity upto 5 KVA all as directed.
111Supply only Fuse unit for voltage stabilizer of capacity upto 5 KVA all as directed.
112Replacement of unserviceable Indoor unit of split type AC 1.5 Ton capacity all as directed. Make: BLUESTAR/ LG/ CARRIER/ VOLTAS/SIDWAL/ Hitachi
113Supply only freon gas R-404A for charging to window/ split type AC"s.
114Taking down window type AC of any capacity by carefully disconnecting the electric connection and carrying out water washing, cleaning the filter and cooling coil and refixing the same in position including testing and commissioning complete all as specified and directed.
115Taking down split type AC of any capacity by carefully disconnecting the electric connection and carrying out water washing, cleaning the filter and cooling coil and refixing the same in position including testing and commissioning complete all as specified and directed.
116Removing from existing location and shifting of split type AC of any capacity and fix factory made fabricated support suitable to mount outdoor unit (one pair per AC including drilling holes in walls for insertion of copper pipe, drain pipe and three core cable and making good the surfaces complete all as specified and directed.
117Removing from existing location and shifting of window type AC of any capacity and fix with suitable wooden frame with second class hardwood in new location including providing three core cable and making good the surfaces complete all as specified and directed.
118S&F in replacement 1/4 inch dia copper pipe with insulation tubular form for split type AC all as specified and directed.
119S&F in replacement 1/2 inch dia copper pipe with insulation tubular form for split type AC all as specified and directed.
120S&F in replacement 3/8 inch dia copper pipe with insulation tubular form for split type AC all as specified and directed.
121S&F in replacement 5/8 inch dia copper pipe with insulation tubular form for split type AC all as specified and directed.
122S&F in replacement angle set for outdoor unit of split type AC all as specified and directed.
123M&L taking out existing unserviceable fan motor from indoor unit of inverter type split AC and supply and fixing new motor of same make as per existing one complete all as specified and directed.
124M&L taking out existing unserviceable fan motor from outdoor unit of inverter type split AC and supply and fixing new motor of same make as per existing one complete all as specified and directed.
125S&F in replacelment PCB (Printed circuit board) with hand smart remote control for inverter type split AC of any make complete all as specified and directed. Note for item No. 122.00 to 124.00: The spares shall be of the same make as that of equipment.