Demolition / Reconstruction Married Accommodation ( For 112 Numbers Of Sailors ) At Svn Colony Visakhapatnam Demolition / Reconstruction Married Accommodation ( For 112 Numbers Of Sailors ) At Svn Colony Visakhapatnam, Visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Demolition / Reconstruction Married Accommodation ( For 112 Numbers Of Sailors ) At Svn Colony Visakhapatnam Demolition / Reconstruction Married Accommodation ( For 112 Numbers Of Sailors ) At Svn Colony Visakhapatnam. Submission Date for this Tender is 14-09-2021. Demolition Work Tenders in Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28701407
Corrigendum : Demolition / Reconstruction Married Accommodation ( For 112 Numbers Of Sailors ) At Svn Colony Visakhapatnam Demolition / Reconstruction Married Accommodation ( For 112 Numbers Of Sailors ) At Svn Colony Visakhapatnam
Open Tender
Indian
Andhra Pradesh
Visakhapatnam
14-09-2021

Tender Details

Demolition / Reconstruction Married Accommodation ( For 112 Numbers Of Sailors ) At Svn Colony Visakhapatnam Demolition / Reconstruction Married Accommodation ( For 112 Numbers Of Sailors ) At Svn Colony Visakhapatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Aug-2021 Revised and Amnd Drawings Other 04-09-2021
2 28-Aug-2021 Revised BOQ BOQ 04-09-2021
3 01-Sep-2021 85396 Date corrigendum Date 14-09-2021
4 07-Sep-2021 85396_Amnd_2 Technical Bid 14-09-2021

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 32.60 Crore /-

BOQ Items

Name of Work: DEMOLITION/RECONSTRUCTION OF 112 NUMBERS OF SAILORS MARRIED ACCOMMODATION AT SVN COLONY VISAKHAPATNAM
Sl. No. Item Description
1NOTE :- Schedule "A" Part I to be quoted by the Bidder. Bidders shall insert their lumpsum amount in Green coloured field under col-7 only
2Construction of Married accn forPOs/LDG below sailors inRCC Framed Structure (G+9storeyed) on pile foundation including, two RCC terrace tanks ( one tank of capacity 2X5,000 Ltrs of partition 10,000 lit for fire fighting, and another 25,000.00 Lit capacity domestic water supply), SS railing, scooter garage in stilt floor, Lift well & Lift store , tie beams, pile caps with PCC and moorum filling uder plinth etc.,but excluding pile foundation complete all as specified and as shown on drawings and as directed.
3Construction of RCC Under Ground sump 70000 liters capacityfor water supply and fire-fighting complete all as specified and as shown on drawings and as directed.NOTES for item No. 1.01 and 1.02: (i) Earth work, excavation, returning filling , disposal of surplus soil to a distance as specified, filling under floors with reference to MGL as shown in the drawings for building portion i.e. up to 3m beyond the external face of plith protection is deemed to be included in the scope of lumpsum quoted against these items.
4NOTE: Schedule "A" Part II to Part XV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under col-07 only
5Lumpsum price worked out by the contractor for " Site Clearance / Area Development / Earthwork/ Excavation", as listed in Schedule "A" Part – II on Serial Page No. 35.
6Lumpsum price worked out by the contractor for " Pile Foundation", as listed in Schedule "A" Part – III on Serial Page No. 36.
7Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – IV on Serial Page No. 38.
8Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – V on Serial Page No. 40.
9Lumpsum price worked out by the contractor for "Sewage Disposal",as listed in Schedule "A" Part – VI on Serial Page No. 42.
10Lumpsum price worked out by the contractor for "External Water Supply",as listed in Schedule "A" Part – VII on Serial Page No. 43.
11Lumpsum price worked out by the contractor for "External Electrification",as listed in Schedule "A" Part – VIII on Serial Page No. 46.
12Lumpsum price worked out by the contractor for "ROADS /PATH/HARD STANDING/CULVERT", as listed in Schedule "A" Part – IX on Serial Page No. 48.
13Lumpsum price worked out by the contractor for "Area Drainage", as listed in Schedule "A" Part – X on Serial Page No. 49.
14Lumpsum price worked out by the contractor for "Rain Water Harvesting", as listed in Schedule "A" Part – XI on Serial Page No. 50.
15Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION", as listed in Schedule "A" Part – XII on Serial Page No. 51.
16Lumpsum price worked out by the contractor for "FIRE ALARAM and DETECTION", as listed in Schedule "A" Part – XIII on Serial Page No. 52.
17Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM ", as listed in Schedule "A" Part – XIV on Serial Page No. 54.
18Lumpsum price worked out by the contractor for "DISMANTLING/ DEMOLITION", as listed in Schedule "A" Part – XV on Serial Page No. 56.
19Schedule "A" Part - XVI[Miscellaneous Items]
20PILE FOUNDATION
21Boring for bored cast-in-situ piles 600mm dia in any strata except SDR/hard rock and getting out and disposal of spoil out side MD land using Hydraulic system of boring method, complete all as specified and directed.
22Boring for bored cast-in-situ piles 600mm dia in SDR/ hard rock and getting out and disposal of spoil out side MD land using hydraulic system of boaring method complete all as specified and directed.
23Carrying out initial load test on 600mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
24Carrying out routine load test on 600mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
25Carrying out lateral load test on cast in situ piles 600 mm dia piles as specified in IS and directed by Engr - in- Charge.
26Carrying out pull out test on cast on situ piles 600 mm dia pile as per specified in IS ,complete all as specified and directed by Engr - in- charge.
27Carrying out low strain integrity test on bored cast in situ piles including analysing the result as per ASTM D 5882 and as directed by Engr - in- Charge.
28Chipping out pile up to cut off level including disposal up to a distance outside MD land all as specified and directed.
29INTERNAL WATER SUPPLY
30S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed suitable for 20mm PP-R pipe complete.
31S&F Bib taps two way, fancy type CP screwed down for size of15 mm dia
32S&F health faucet chromium plated , fancy type with steel flexible complete of size of15 mm dia
33INTERNAL ELECTRIFICATION
34Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and required module plate top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one light point controlled by one switch complete all as specified and as directed.
35Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of2mm thick MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one bell point controlled by one bell push complete all as specified and as directed.
36Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one fan point controlled by one point complete all as specified and as directed.
37Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 6 Amp socket on independent board complete all as specified and as directed.
38Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 6 Amp socket on same board complete all as specified and as directed.
39Point Wiring complete with 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 15 Amp socket on independent boardcomplete all as specified and as directed.
40Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of2mm thick MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one light point controlled by two number two way switch complete all as specified and as directed.
41LED adore lamp for AC 240Volt supply, B22 type,CDS five star, 10 watts of five star rated complete all as specified and as directed.
42Energy efficient LED tube light fitting suitable for mirror light with tube 5 wattsor nearest size, 240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and directed.
43Supply and fixingEnergy efficient LED tube light fitting with tube 9/10 wattsor nearest size ,240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
44Energy efficient LED tube light fitting with tube 20 wattsor nearest size, 240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed.
45LED Security light fitting with tube 30W new generation energy saving & environmental friendly long lifemade up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening seperate driver compartment with IP66 protectionpre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI tubing light grade of 32mmdia bend to shape for fixing on wall/pole withsuitable MS brackets nuts and bolts etc. compelte all as specified and as directred.
46Ceiling fans AC single phase 230V of size 1200mm sweep, copper wound with complete set of fixtures such as canopy, down rod etc, 5 star rating, metallic bodycomplete with and inclusive of making necessary electric connections from ceiling rose to fan tthrough twin core flexible wire all as specified and directed.
47S&F Exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 HzAC supply fixed on wall making opening,fixing and making good the distrubered surfaces etc. complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as spcified and as directed.
48S&F Exhaust fan 300 mm sweep, metallic body (Heavy duty),900 RPM, complete with louvers suitable for operation on 240 V AC, 50 HzAC supply fixed on wall including making of neccessary opening, fixing and making good the disturbed surfaces etccomplete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
49S&F Sub main wiring with 4 runs of single core 16 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, 32 mm dia with all accessoriesconcealed in Walls / Roofs / Floors / Ceiling etc. including one run of 16 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. (Bus bar trunk/MCCB to VTPN DB of each floor). Note: 4 runs of 16 Sq.mm, 1 runs of 16 Sq.mm & one run of 32mm dia PVC Conduit will be measured as one unit
50S&F Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, 20 mm dia with all accessoriesconcealed in Walls / Roofs / Floors / Ceiling etc. including One run of 6 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 6 Sq.mm, 1 runs of 6 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit
51Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, 20 mm dia with all accessoriesconcealed in Walls / Roofs / Floors / Ceiling etc. including One run of 2.5 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 2.5 Sq.mm, 1 runs of 2.5 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit
52Supply and fixing concealed in wall Vertical MCB DB double door type,TPN8 way 415V, 50Hz , IP 43 protection with 200A rated bus bar , including provision for fixingMCCB FP 63 amp as incommer andoutgoing circuits MCB SP/TP complete,fill empty way with blanking plates complete all as specefied and directed. Note:- MCCB and MCBs shall be measured and paid seperately.
53Supply and fixing single phase electronic Energy meter tamper proof with LED display, 240 volt , 50Hz AC supply, 10 to 30 amps capacity complete all as specified and as directed.
54Supply and fixing prefabricated meter box made out of 2mm thick CRCA sheet duly powder coated of approx size 50cm x 60 cm to accommodate 6 Nos single phase energy meter , front portion of the meter box to be provided with six opening to take the reading of energy meter and the six slit is to be covered/fixed with glass, necessary sunmica sheet of suitable size to be provided inside the meter box to fix the energy meter, with locking arrangements complete including sealing of energy meter all as directed and as specified. Note: Energy meter shall be measured and paid seperately.
55Supply and fixingtelephone socket with and inclussive of prefabricated terminal box and switch platefor fixing telephone socket all as specified and directed.
56Supply and fixing TV socket with and inclussive of prefabricated terminal box and switch platefor fixing TV socket all as specified and directed.
57Supply and fixing/drawing PVC insulated telephone cable one pair onexisting PVC conduits concealed to wall,of Havells make basic code No "WHTTATEL1P40 or equivalent make. Note : PVC conduit shall be measured seperately, both end of the telephone cable to betaged/marked in colour code sleevesof each qtr number.
58Supply and fixing/drawing PVC insulated telephone cable three pair onexisting PVC conduits concealed to wall,of Havells make basic code No "WHTTATEL3P40, or equivalent make. Note : PVC conduit shall be measured seperately, both end of the telephone cable to be taged/marked in colour code sleeves at ground floor and ateach floor junction box.
59Supply and fixing PVC junction box of approx size 10cm x 15 cm rectangular type concealed to wall to accommodate PVC connector of six way for telephone cable on each floor.(for three DUs)
60Supply and fixingjunction boxes of FRP body of size 15 cm x 10 cm with and including PVC connector three way for telephone cable at each floor
61Supply and fixingjunctionboxes of FRP body of aprox size 50 cm x 30 cm with and including PVC connector 56way for telephone cable at ground floor floor
62EXTERNAL WATER SUPPLY
63Material and Laboure for laying of Ductile pipe with spigot and socket end centrifugally cast(spun) class K-9 of 100 mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioningall as specified andas directed.
64Construction of Valve Chamber of size 750 X 750 X 750 mm , with 50mm thick PCC 1:5:10, Type E2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 100 mm thick PCC, 1:3:6, Type C1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick internally and externally up to 50mm below GL including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and includingnecessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
65Cutting existing DI pipe line for alterations or additions necessarily done in position without taking down and inserting T of 100 x 100 x 100 mm and Tee for tapping all as specified and directed.
66Supply, install, testing and commissioning of centrigugalpump set with minimum ratings not less than20 HP , 70 Mtr Head , 10LPSwith delivery size of 80 mm bore,with 4 pole, 415 Volts, 50 Hz, AC 3 Phase supply, electric driven, inclusive of air valve at delivery, pressure guage,star delta starter for pumps along with cabling by XLPE Copper cables from starter to Pump set with cable tray and PCC foundation. all as specified and directed .
67Supply and fix flanged end lift type Foot valve 100 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed.
68Supply and fix sheet metal encloser with provision of fixing incoming and out goingcables with bus bar and cable connection to tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed. (For Fresh Water Pumps) Incomming:- (a) MCCB 63 Amps,25 KA - 01 Nos Outgoing:- (a) MCB 32 Amp,16 KA TP - 03 Nos(for two pumps+ 01 Spare) (b) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases-03 Nos
69ROADS /PATH/HARD STANDING/CULVERT
70Granular sub Base (GSB) with grading V of 150mm thick Compacted thickness (laid in two layers of 75mm each, Compacted seperately) confirming to grading as specified, spread, rolled and consolidated to required gradient asnd camber complete using necessary mechanical paver/ Grader and vibratory soil compacter of Capacity 8-10 ton all as specified and as directed. (a) Pavement shall be made for solid quantity arrived after consolidation. (b) Compaction of granual sub base filling shall be carried out under Optimum moisture condition to achieve 98.50 modified density. (c) Curing shall be carried out as per IRC recommendations. (d) Before execution of this item the approved material obtained from outside MD land shall be tested/ checked for suitability to use.
71(e) The lead/ Royalty involved is to be ascertained by the contractor before quoting his tender and no extra payment/ Adjustment for increased in lead or Rate of Royalty due to whatever reason shall be admissible on his account. (f) Contractor shall use Vibratory earth compactor inlieu of Power roller to achieve 98.00% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. (g) GSB shall be as per MORTH specification as detailed in Perticular specification.
72Wet mix Mecadam of 250mm thick (Compacted thickness) laid in three equal layers compacted seperately with Coarse aggregate of specified grade spred rolled and consolidated to required gradient and camber complete using mechanical paver/ Grader and Pandom Vibrator of capacity of minimum 8-10 Tons at OMC to achieve atleast 98% MDD determained using modified Proctor density determination method as per IS code on prepared GSB surface complete all as specified and as directed. Note : 1. The rate quoted shall be for 250mm compacted thickness. 2. Each layer shall be rolled seperately.
73M & L for Painting lines, dashes, arrows, letters, etc. on road surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause. 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement upto 160 Degress C, including cleaning and drying the road surfaces to ensure dust,oil,grease and moisture free surface beforeapplying paint complete all as specified as directed.
74EXTERNAL ELECTRIFICATION
75XLPE insulated and screened insulated, FRLS armouredand PVC bedded underground HT cable, ISI marked with aluminium stranded conductor 11000 Volt grade (heavy duty) of size 3 Core, 120Sq.mm cross section conforming to IS-7098 (Part-II) laid in trenches, fixed to walls or passing through pipes and connecting up complete all as specified and directed.
76XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 185Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
77XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 150Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
78XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 120Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
79XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 50Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
80XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 16Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
81Supply, install, testing and commissioning outdoor type SF6 insulated compact R.M.U. extandable on both sides with rated voltage 11 KV rated current 630 A, short circuit breaking current 16 KA and making capacity 40KA ,fully arc proof metal enclosed, free standing, floor mounting, flush fronted type consists ofmanually operated non draw out typeSF6 filledload break switch-01 No (Incomers)and 2 Nos outgoing SF6 filled load break switches with integrated relays and related CTs as specified below, cable switch module and an interlocking mechanism with the earthing switch all as specified and directed. Degree of protection shall beper manufacturer specifications. (a) Fixed type voltage indicators and electronic short circuit indicators for simple fault indication b) Resin cast CT with ratio 75/1-1 with 15VA burden class1 for metering and class 5 P10 for protection-Set of three c) Resin cast potential transformers with ratio 11KV/1.732, 110V/1.732, 200 VA class1 with HT fuses mounted on with drawable rack d)Self powered microprocessor controlled numeric relay comprising of three over current , one earth fault protection relay with high set for both phase & earthand with fault memory, universal auxliary supply Model No.IRI1- WD of C&S make / Model No MC-61A of L&T /SIEMENS/ABB/AREVA
82e) Trip circuit supervision relay Model No. MRA1 of C&S make or equivalent in L&T/SIEMENS/ABB/AREVA f) Master trip relay Model No. CLR of C&S make or equivalent in L&T/SIEMENS/ABB/AREVA g) Power pack equipment , withback up for 15minutes including batteries complete suitable for operation of relays h) Internal bus earthing with flat GI strip of size 50x6mm i) Digital ammeter 100A CT operated with selector switch j) Digital voltmeter 15KV with selector switch k) Manual trip switch k) one No. of space heater with thermostat l) One No.of inside lamp with switch (40W 230V) m)One No. of plug point with switch (5A, 230V) n) Copper bus bar common for outgoing feederso) Manual charging/ operating arrangement p) Fuses for metering and protection systemq) Push buttons for accepting faults and reset r) Rear bottom entry of HT cables s)LED indicating lamps for:- Auto trip,Spring charge,Fault alarm,Trip circuit healthy,Trip circuit unhealthy,Breaker ON/Off. t) Complete control panel wiring with copper wire of size not less than 2.5 sqmm u) Civil works required for foundation as per manual of manufacturer
83Supply, install, testing and commissioning of factory made outdoor type APFC panel CPRI approved OEM, free standing floor mounted, dust and vermin proof Automatic Power Factor Correction (APFC) panel of capacity 100 KVAR with 06 steps (2x25+3x10), compartmentalised, outdoor type, fabricated as per IEC 61921 with 3.15mm thick CRCA sheet and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces with minimum IP 43 ingress protection suitable for 3 Phase, 415 Volts & 50 Hz system with MD-XL capacitor including suitable rated TPN, MCCB, 415 Volts, 35 KA rupturing capacity as incomer duly controlled by auto and manual option including instrumentation such asPower Factor Meter-1 No., digital type ammeter of range 0 to 200 Amps with CTs & Selector Switch-1 No., digital type volt meter of range 0-500 Volts-1 No., relay, auxiliary contacts, CTs, phase Indicating LED Lamps (RYB), selector switches etc., suitable internal wiring with copper cable of suitable size, double stud hinged door, front openable with locking arrangement including interlocking with switch gears complete andpanel shall be fixed with angle iron frame made of angles of size 50x50x6mm at corners and ISMC of suitable size for base, embedded 600mm below ground level in PCC 1:2:4 type B1 using 20mm grade stone aggregate, 600mm above ground level including connecting up with existing incoming and outgoing cables etc. complete all as specified and as directed.
84Suppy, fixing and testing of LT Panel board (Feeder Pillar Box) made out of CRCA sheet 3.15 mm thick of suitablesize but not less than 1.2x1.0x0.5m size outdoor PedLT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal typeof suitablesize but not less than 1.5x1.2x0.40m sizetotally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V, 600 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (Main LT FPB)
85INCOMING: - a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 125 A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos.MCCB AC 3 Phase 415 V, 50Hz 4 pole 500 A capactiy 35kA microprocesser based adjustable type - 1 No. OUTGOING: - a) Adjustable type MCCB 4 Pole 160 Amp 50 Hz 415 Vwith rupturing capacity 25 KA-03 Nos(Bldg -02, APFC - 01 & 01 No spare),b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 125 A capactiy 25kA with adjustable type thermal and magnetic setting relays - 03 Nos ( AMF Panel - 01,APFC - 01 and 01 No spare) c) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs d) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
86Supply fixing and testing of LT Panel board (Feeder Pillar Box) made out of CRCA sheet 3.15 mm thick of suitablesize but not less than 1.2x1.0x0.5m size outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: INCOMING:- a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 125 A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos OUTGOING: - a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 A capactiy 25kA with adjustable type thermal and magnetic setting relays - 03 Nos(Lift-02 No, Spare- 01 No)., b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 32 A capactiy 25kA with adjustable type thermal and magnetic setting relays - 04 Nos (for Street light-01 No, Boster Pump-02 Nos ,spare-01No).,c) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs ., d) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
87Supply and Installation Supply, installation, testing and commisioning of Bus bar trunking system for the complete bldg power supply duly insulated three phase of rating 250 Amps, 25 KA 415 Volts aluminium conductor galvanised GI enclosure 0.8 mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with MCCB 250 A 25 KA 4P with rotary handle, termination links of bldg comprising offollowings:
88Supply and fix Straight feederof Busbar trunking system as specified and directed.
89Supply and fixing of Flange end of Busbar trunking system as specified and directed.
90Supply and fix End Cover - 01 Nos(for main riser) of Busbar trunking system as specified and directed.
91Supply and fix Brackets of Busbar trunking system as specified and directed.
92Supply and fix Springs Hangers of Busbar trunking system as specified and directed.
93Supply and fix Fire barrier complete for BBT of Busbar trunking system as specified and directed.
94Supply and fix Addaptor box of Busbar trunking system as specified and directed.
95Supply and fix Copper braided flexibles complete for BBT of Busbar trunking system as specified and directed.
96Supply and fixing ofExternal GI strip 32 x 6 mmof Busbar trunking system as specified and directed.
97Supply and fix 63A 4P lightning trunking of Busbar trunking system as specified and directed.
98Supply and fix Flexible elbow as required at site of Busbar trunking system as specified and directed.
99Supply and fix Horizontal elbow as required.of Busbar trunking system as specified and directed.
100Supply and fix MS 100A Centre feed Unit IP 55 of Busbar trunking system as specified and directed.
101Supply and fix 63 A TAP OFF Box Prov for MCB of Busbar trunking system as specified and directed.
102Supply and fix End cover for 63 A feeder of Busbar trunking system as specified and directed.
103Supply and fix MS Sleeve IP 55-10 Nos of Busbar trunking system as specified and directed.
104Supply and fix MS Plug point Gasket IP 55-10 Nos of Busbar trunking system as specified and directed.
105Supply and fix suspenssion Bracket of Busbar trunking system as specified and directed.
106Supply and fix 125 A tap off box with,MCCB 63A 4P, 16 KAto Busbar trunking system as specified and directed.
107Supply and fix 250 A 25 KA 4P MCCB to Busbar trunking system as specified and directed.
108Supply and fix sheet metal encloser ,provision of fixing incoming and out goingcables with bus bar for cable connection alluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Block Panel) all as specified and as directed. (For lift machine room) Incomming:- (a) MCCB 63 Amps,25 KA - 01 Nos Outgoing:- (a) MCB 32 Amp,16 KA TP - 03 Nos(for two lift panel+ 01 Spare). (b) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
109Supply & Fix Integral LED street light Luminaire 40 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing all as specified and directed.
110Supply & Fix Loop in loop out box of FRP made with IP 65 protection of thermoplasic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangemets and with cable glands, etc all as specified and directed.
111Earthing complete with Galvanised iron earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6 mm GI earth strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m in length from earth plate, Earth Plate Electrode surrounded by 150 mm thick packed layers of Charcoal and Rock Salt filled in alternate layers, connected to the plate by means of brass Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Rock Salt, PCC chamber[1:3:6, Type C1]with RCC cover of 1:2:4 type B1, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
112Earthing complete with copperplate electrode 60 cm X 60 cm X 3 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to copper strip of 20mm x 3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed. (item caters for Internal Elec)
113M & L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
114Supply and fix time switches 415 V ,50 Hz of 20 Amp rating with contactorFitted inside steel enclosure all as specified and as directed
115M & L for masonry plat form for trasformer of size 1.5x1.5x1.2 Mtr with RR masonary in CM 1:6, in foundation base75mm thick PCC 1:4:8 type D2 with 40 mm graded aggregate, and 100mm thick PCC 1:2:4 type B1 with 20 mm graded aggregate at top of the platform, 20mm thick plastering in CM 1:6 externally upto50mm below GL and three coats of white wash including Earth work excavation complete and specified and directed by Engineer-in-Charge.
116Supply and fix HT Cable route indicator cast iron 150mm dia, 6mm thick plate with arrow for indicating direction 3mm embossed letters with 2No of holes and mounting on angle iron of 50x50x5mm of 1000mm sise with painting including with PCC, Earth work excavation & painting complete and specified and directed by Engineer-in-Charge.
117Supply,installation,testing and commissioning of silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 100 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:-(i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design., (ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed., (iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test.
118(A) Alternator :-Standard design alternator rated at 100 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC,3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class "H" and voltage regulation of+/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722., i) Insualation class - "H‘., ii) Temparature rise Class - "H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%.,
119(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- i)Fly wheel with housing., ii) Cooling system :- Moulded radiator with fan & belts., iii) Cooling Water pump : - Centrifugal type belt driven., iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.Exhaust gas turbo charger type. Exhaust manifold
120Silencer : Residual type Bellows., iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters,Fuel hoses. v) Lub oil System : -Lubricating oil filter ,Lubricating oil pump., vi) Air Intake System : Air intake Manifold Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator., ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length fromself starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch
121Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan., Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel., x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standardpractice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine., xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling., xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms. xv) Fuel Tank :- Additional Fuel Tank of capcaity to suit Daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the accoustic enclosure., xvi) MS pipe line to and from the fuel tank to the DG Set.
122C) AMF Panel :- Factory made Out door type control cubical made out of 3.15 mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 100 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standardstandard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc., g) Annuciation with indication lamps for :(i) Low lub oil pressure.(ii) High Water Temparature..,(iii) Engine over speed. (iv) Battery low voltage., Controls :- a) Load on Indicationb) Load off indication c) Engine start push buttond) Engine stop push button e) Fault accept / reset push button., f) Battary Charger :-(i) Transformer (ii) Rectifier (iii) Restance (iv) DC Volt meter (v) DC Ammeter (vi) Charger rate selector switch
123D) Accoustic Enclosure:-Manufactured by OEM suitable for 100 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board., (iii) The generating setbattaries and control panel should be inside the enclosure. (iv) Fuel tank should be out side the enclosure in the sub station building. (v) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms., vi) The accoustic should be composite in construction and fully assembled integral unit., vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulatedplat form viii) The fuel tank is to be located inside the enclosure., ix) The DG Set should be provided with external Emergency stop push button x) The enclosure should be suitably illuminated by LED Lamp fittings.
124xi) The noise level should be 75 dba at 1m under free field conditions., xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade. E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 2. 4 x 0.8 m for placing of DG Setcomplete all as specified and directed.
125Supply, install testing & commissioning of elctrically operated passengers lift of capacity08 passengers (544 Kg) , 1.5 metre/sec speed with, automatic GIEN micro stroke button control, micro processor based controler simplex selective / collective control suitable for 3 phase, 50 Hz 415 volts AC supply indepedent operation with AC variable frequency (AC VVVF) control closed loop with power saving regenerative drive)with suitable motor and gear less unit to serve ground plus nine upper floors ie withwith or without attendent suitable for synchorinised operation automatic power operated cntre opening sliding stainless steel door with mirror finish of 16 guage with infra-red sensors all along the height for car door with automatic rescue / leveling device (ARD) (with + or -5 mm) with suitable batteries , haul position digial indicators in car and all landing with call indicating lights etc including necessary hoists and beams for mounting mchine in the machine room including all civil works required in connection with erection of lifts complete all as specified.to serve upto 10 floors (G +9 floors) all as specified and as directed (a) Fire man switch., (b) Automatic rescue devide (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funnign the lift with full load., c) Battery operated emergency light (Led ceiling fitting), alarm (speaker for emergency alarm sustem to be fixed) and stop button in car with rechargeable arrangement for battery., d) Four sleek circular 5 Watt LED light fitting in false ceiling . e)One Sleek circular PVC heavy duty fan in false ceiling. Make for(c) & (d) : Philips / Bajaj / Havells / Crompton Greaves.
126f)Aluminium chequered plate (3 mm thick) as flooring joint in chequered palte should not more than one and top covering with granite flooring complete. g)Non stop button / independent operation. h)Over load warning indicator both audio and visual type with tripping sustem having relays etc (overload protectin / tripping system). j)Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k)Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish. l)Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS. m)Mirror of 4 mm thickness of suitable size as specified. n) Opening with mirror of 5mm thick 200 x 800 mm size in all the doors (Car/Landing doors). o) Specification plate with complete details . p)Contineuos earthing for machine and equipments. q) Steel wire rope of adequate sixze as per relevant IS and as per manufacturerer specifications.
127r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete.s) Full length display indicator panle. t)Main drives and control shall be of latest, high effective and low power consumption. u) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage. v) Stainless steel fron opend landing door with small opening for vision of size 200 mm x 800 mm with toughended galss not less than 8mm thick.Make of Toughened Glass : Safgex / Saint GobainGlass / Modiguard float glass /kesar / Asshi Indian / Atul Tuf / Hindustan pilkington glass works / Trivenin float glass. w) Intercome be connected with nearest security post.
128Design, supply ,install, testing and commissioning of electrically operated passengergearless liftof capacity 13 passenger lift (G+9) (884 Kgs) in the existing lift well, 1.5 m/s speed with automatic GIEN micro stroke button control, microprocessor based controller, simplex selective /collectivecontrol suitable for 3 phase, 50 HZ 415 volts AC supply independent operation with AC variable voltage variable frequency (AC VVVF) control closed loop with power saving regenerative drive with suitable motor and gear less unitto serve ground plus nine upper floors i.e with 10 stops and 10 landings with or without attendant suitable for synchronised operation automatic power operatedcentreopening sliding stainless steel door with mirror finish of 16 gauge with infra-red sensors all along the height for car door andview glass on upper part of all doors and built in announcing system without hand set ( 3 Nos. one each in car, machine room and near ground floor landing door) complete with automatic rescue/leveling device (ARD) system (with + or -5 mm) with suitable batteries, haul position, digital indicators in car and all landingwith call indicating lights etc complete conforming toIS- 14665 including necessary joists and beams for mounting machine in machine room including addition and alteration to existing lift well if any and all necessary civil works in connection with erection of lift complete all as specified and as directed to serve upto 10 floors (G+9 floors).
129(a) Fire man switch., (b) Automatic rescue devide (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funnign the lift with full load., c) Battery operated emergency light (Led ceiling fitting), alarm (speaker for emergency alarm sustem to be fixed) and stop button in car with rechargeable arrangement for battery., d) Four sleek circular 5 Watt LED light fitting in false ceiling . e)One Sleek circular PVC heavy duty fan in false ceiling. Make for(c) & (d) : Philips / Bajaj / Havells / Crompton Greaves.
130f)Aluminium chequered plate (3 mm thick) as flooring joint in chequered palte should not more than one and top covering with granite flooring complete. g)Non stop button / independent operation. h)Over load warning indicator both audio and visual type with tripping sustem having relays etc (overload protectin / tripping system). j)Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k)Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish. l)Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS. m)Mirror of 4 mm thickness of suitable size as specified. n) Opening with mirror of 5mm thick 200 x 800 mm size in all the doors (Car/Landing doors). o) Specification plate with complete details .
131p)Contineuos earthing for machine and equipments. q) Steel wire rope of adequate sixze as per relevant IS and as per manufacturerer specifications. r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete.s) Full length display indicator panle. t)Main drives and control shall be of latest, high effective and low power consumption. u) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage. v) Stainless steel fron opend landing door with small opening for vision of size 200 mm x 800 mm with toughended galss not less than 8mm thick.Make of Toughened Glass : Safgex / Saint GobainGlass / Modiguard float glass /kesar / Asshi Indian / Atul Tuf / Hindustan pilkington glass works / Trivenin float glass. w) Intercome be connected with nearest security post.
132AVIATION LIGHT
133Cable PVC insulated armoured PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 Sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable clamps spacers bolts, nuts etc.Complete all as specified and directed.
134Aviation obstruction light LED type filament-less bulb with 10 Watt bulb complete including standard fixing arrangements complete all as specified and directed.
135Time switches 250V single phase of 20 Amps rating with contactor fitted inside steel enclosure complete all as specified and directed.
136FIRE FIGHTING SYSTEM, FIRE ALARM AND DETECTION
137Cutting existing pipe any size/type not less than 150 mm dia for alter for alterations or additions necessarily done in position without taking down and inserting T of 150 x 150 x 100 mm and Tee of 100 x 100 x 100 mmfor tapping all as specified and directed.
138GEYSER
139Supply, installation, testing and commissioning of geyser electric driven (single phase), PVC body havingcapacity of 15 litre of 5 star rated with flexible hot/cold flexible water pipe and including all acessories complete all as specified and directed.
140ARBORICULTURE
141Supply & Planting carpet Grass by piece turfing including preparation of ground upto 30 cm deep and filling soft soil, cow dung and watering etc complete all as specified and directed. Note: Loose soil and cow dung shall be measured and paid separately UNDER SUPPLY ONLY.
142Supply only approved loose soil of best quality for plantation.
143Supply only approved manure (Cow dung) of best quality for plantation.
144Supply only approved vermi compost of best quality.
145Supply and plantation of Mango (height of plant not less than 2.0m above ground level) incl preparation of ground up to 560cm deep and filling of good earth, cow dung vermi compost and watering etc complete all as directed by the Engineer-in-charge.
146Supply and plantation of Guava of height not less than 1.50 m above ground level) incl preparation of ground up to 560cm deep and filling of good earth, cow dung vermi compost and watering etc complete all as directed by the Engineer-in-charge.
147Supply and plantation of Naseberry of height not less than 1.50 m above ground level) incl preparation of ground up to 560cm deep and filling of good earth, cow dung vermi compost and watering etc complete all as directed by the Engineer-in-charge.
148MAINTENANCE OF ARBORICULTURE [Phase-III ] [Schedule "A" Part – XVII]:
149Material and labour for maintenance including watering and fertilization of all the grass/plants/trees by weeding housing saucer melding once in every 15 days, planting new plants/grass spices and height with out any extra cost to the department for period of maintenance period of two years from the completion date of project complete all as specified and directed.
150SCHEDULE "A" PART-XVIII PHASE -IV FIRST YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 123 AND 126AFTER COMPLETION OF DEFECTS LIABILITY PERIOD OF 02 YEARS
151Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs)to serve G+9 upper floors all as mentioned vide SI No. 123 of Sch "A" Phase-I (Eight Lifts) during 1st year after expiry of defects liability period all as specified and directed
152Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs)to serve G+9 upper floors all as mentioned vide SI No. 126 of Sch "A" Phase-I(one Lift) during 1st year after expiry of defects liability period all as specified and directed
153SCHEDULE "A" PART-XIX PHASE -V SECOND YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 123 AND 126AFTER COMPLETION OF FIRST YEAR COMPREHENSIVE MAINTENANCE.
154All as per description of item No. 149 but second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
155All as per description of item No. 150 but second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
156SCHEDULE "A" PART-XX PHASE -VI THIRD YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 123 AND 126AFTER COMPLETION OF SECOND YEAR COMPREHENSIVE MAINTENANCE.
157All as per description of item No. 149 but third year after expiry of After completion of second year Comprehensive Maintenance.
158All as per description of item No. 150 but third year after expiry of After completion of second year Comprehensive Maintenance.
159Note for SL No: 149 to 156 :- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Required spares shall be measured and paid seperately as supply only under respective items below. (iii) However quoted rate is deemed to be inclusive for all other spares which have not been catered for seperatly. No extra cost is admissible on this account. (iv) Sufficient manpower having sound knowledge and well experience of lifts shall be employed by the contractor. all the staff employed for maintenance shall be reported to AGE E/M office daily and will give day to day progress duly entered in the concerned registers. (v)Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts.
160(vi)Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation.(vii)Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor.
161(viii) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engr -in-Charge. (ix) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM. (x) The quoted rate shall be deemed to be included the above aspect and for consumables such as timely toping up oils,acrylic covers, fuses, grease,waste cotton, stationery and other miscellaneous items and all minor & major spare parts other than mentioned below. (xi) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/accredited agencies service personel. The MoU shall besubmitted at least 06 monthsprior to issue of completion certificate of main contract as per Work Order No I.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail