Repair / Maint / Replacement Of Unsv Ceiling Fan, Exhaust Fan, Pedestal Fan, Wall Mounted Fan And Elect Meter Including Connected Works At Af Stn Bihta Under Ge ( Af ) Bihta Repair / Maint / Replacement Of Unsv Ceiling Fan, Exhaust Fan, Pedestal Fa, Bihta-Bihar

Military Engineer Services-MES has published Repair / Maint / Replacement Of Unsv Ceiling Fan, Exhaust Fan, Pedestal Fan, Wall Mounted Fan And Elect Meter Including Connected Works At Af Stn Bihta Under Ge ( Af ) Bihta Repair / Maint / Replacement Of Unsv Ceiling Fan, Exhaust Fan, Pedestal Fa. Submission Date for this Tender is 26-08-2021. Ceiling Fan Tenders in Bihta Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

28701394
Corrigendum : Repair / Maint / Replacement Of Unsv Ceiling Fan, Exhaust Fan, Pedestal Fan, Wall Mounted Fan And Elect Meter Including Connected Works At Af Stn Bihta Under Ge ( Af ) Bihta Repair / Maint / Replacement Of Unsv Ceiling Fan, Exhaust Fan, Pedestal Fa
Open Tender
Indian
Bihar
Bihta
26-08-2021

Tender Details

Repair / Maint / Replacement Of Unsv Ceiling Fan, Exhaust Fan, Pedestal Fan, Wall Mounted Fan And Elect Meter Including Connected Works At Af Stn Bihta Under Ge ( Af ) Bihta Repair / Maint / Replacement Of Unsv Ceiling Fan, Exhaust Fan, Pedestal Fan, Wall Mounted Fan And Elect Meter Including Connected Works At Af Stn Bihta Under Ge ( Af ) Bihta

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 8000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : Repair/Maint/Replacement of unsv ceiling Fan, Exhaust Fan, Pedestal Fan, Wall mounted Fan and elect meter including connected works at AF Stn Bihta under GE (AF) Bihta
Sl. No. Item Description
1Material and labour for taking down of ceiling fan/ exhaust fan from ceiling/wall any type and make cleaning the fan and replace the wornout, steel split pin, rubber reel, washer, screws, nut bolts etc. Greesing/ oilingthe fan including replacing old connecting wire complete and made it fully smoothfunctional, refixing in position and testing before fixing in the presence and to entire satisfaction of Engineer-in-charge complete all as specified and as directed.Note :Spare parts/items required to make the fan functional shall be measured and paid separately under appropriate items.
2Supply only the spare parts/items for serialitem No 1above to make it fully functional complete all as specified and directed. (a)Supply onlyFan clamp made of SS.
3(b) Supply only fan capacitor 2.5MFD Make: Philips/Bajaj/Havells
4(c) Supply only fan capacitor 3.15MFD. Make: Philips/Bajaj/Havells
5(d) Supply onlyMS down rodmade of 15mm dia GI, 30 cm long
6(e) Supplyonly Aluminium fan blade 1200/1400mm sweep for ceiling fans . Make : Orient / USHA / BAJAJ
7(f) Supply onlyMS mounting clamps for Exhaust fan with frame suitable for 300mm/450 mm sweep exhaust fans.
8(g)Supply onlyExhaust fan blade made of SS for 300/450 mm sweep exhaust fans. Make:- Orient/USHA/Bajaj
9S&F Electronic fan regulator stepped type (flush type) 240 volt ,50Hz,single phase on existing phenotic laminated sheet including taking down old unsv one and connecting complete all as specified and as directed.
10Material and labour for dismantling/ opening complete fan obtain from item No 1 here- in- before, assembling and testing in presence and to entire satisfaction of Engineer-in-charge complete after the following repairs : (a) Supply and fixing fan bearings complete all as directed Make : SKF and all as per existing make
11(b) Supply and fixing gun metal bushes all complete all as directed.
12Material and labour for dismantling, opening complete fan obtain from item No 1and rewinding the same with super enamel copper conductor of suitable size and meet to original specifications & speed etc. Using proper insulation and varnish, sleeves etc asssembling and 8hrs continous testing before refixing at site complete all as specified for the following sizes :Note : (i) Rewinding/ repairs of fans shall becarried out at AGE E/M store yard in the presence of Engineer-in-charge(ii) Transportationcharges for to and fro wiil be deemed to be included in quoted unit rate. (ii) Spare parts/Items required for smooth functioning of fan shall be measured and paid separately under appropriate items . (a) Ceiling fan 1200/1400mm sweep.
13(bExhaust fan 450mm/300 mm sweep
14(c)Wall mounted/ Padestal fan 450mm sweep
15S&F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthedstranded copper conductor cable 4 sqmmas current carrying conductor and one run of 4.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 4 sqmm all as specified and directedincluding taking down old unsv one. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.Make: RR cable/Universal/Plaza/Finolex
16S&F in repairMCB’s single pole,6 Amp to 32 Amp, 240 volts, ""C"" curve having currenr rating 10 KA complete all as specified and as directed. Make:Sheineder/ Legrand/L&T
17S&F in repair switch piano flush button single pole one way 5 Amp, 230 volts conforming to IS 1293-2005 and ISI marked complete all as specified and as directed. Make:Havells/Kinjal/Plaza/Leader
18S&Fin repairr socket outlet, 3 Pin,5 Amp flush 230 volts conforming to IS 1293-2005 and ISI marked complete all as specified and as directed. Make:Havells/Kinjal/Plaza/Leader
19S&Fswitch sockst combination 2 in 1, 6 pin 5 & 15 Amps flush type universal , 230 volts conforming to IS 1293-2005 and ISI marked complete all as specified and as directed. Make:Havells/Kinjal/Plaza/Leader
20Material and labour for taking down of electric water heater from wall of capacity 25/50ltrs, dismantling/opening the same, servicing the electric water heater, ie, cleaning internally and externally complete and replacement of wornout, MS nut bolts, washers, clamps etc and made it fully functional assembling, tested in the presence and to entire satifaction of Engineer-in-charge and fixed in position as directed and connected complete all as specified and as directed. Note:- Spare parts/items if required for making the water heater fully functional shall be measured separately in approrpriate item(s) to make it fully functional as supply only.
21Supply only the following spare parts/item required to make the water heater fully functional taken down vide items No20here-in-before complete all as directed by Engineer-in-charge.(a)Elect water heater element 2/1.5KW as per existing size and specification
22(b) Apparatus (Syphon assembly) plate as per existing size,specification and make.
23(c)Thermostate switch 30-70ºC ranging.as per existing size ,specification and make.
24(d) Copper vessal (inner tank) of weighting 3.5kg suitable for water heat 25 ltr capacityas per existing size ,specification and make.
25(e) SS vessal (inner tank) suitable for 25ltrs capacity water heateras per existing size ,specification and make.
26(f) Copper vesal (inner tank) of weighting 4.5kg suitable for 50ltrs capacity water heater as per existing size ,specification and make.
27(g)SS vessal (inner tank) heavy duty suitable for 50ltrs capacity water heateras per existing size ,specification and make.
28(h) Indicator lamp neon type 230w as per existing size ,specification and make.
29S&F in repair non return valves cast copper alloy screwed down, high pressure ,screwed both ends for iron pipe or brass ferrule 15 mm dia/bore complete all as specified and as directed. Make : Theta/Dass Pass /Racold
30S&F in repair pressure release valve of brass inner threaded of 15 mm dias per sample approved by Engineer-in-charge complete all as specified and as directed.Make : Theta/Dass Pass /Racold/kartar/Leader/Kirloskar.
31S&F pressure release valve of brass outer threaded of 15 mm dia as per sample approved by Engineer-in-charge complete all as specified and as directed. Make : Theta/Dass Pass /Racold/kartar/Leader/Kirloskar.
32S&F in repair PVC polythene connection steel bedded heavy duty for 15 mm dia/bore pipe 450mm long with CP brass nuts and leads PVC washer 02 Nos on each endsfor Hot water complete all as specified andasdirected. Make : Prayag/ Polytuff/supreme.
33S&F in repair PVC polythene connection steel bedded heavy duty for 15 mm dia/bore pipe 450mm long with CP brass nuts and leads PVC washer 02 Nos on each endsfor cold water complete all as specified andasdirected. Make : Prayag/ Polytuff/supreme.
34S&f in repair PVC insulated copper cable 3 core 40/ 0.0076,AC 1100/660 volt complete all as specified andasdirected. Make :RR cables/Havells/Plaza
35M & LMetallic fastener screw 75mm long 6mm dia with bolt for hanging Geyse, complete all as specified and directed.
36M&L prepration of outer surface of water heater, filling all cavities and rubbing the surface to achieve smooth fininish and applyingtwo coat of synthetic enameled paint over a coat of red oxide primer on outer body surface of storage type geyser of capacity 25 to 50 litres complete includingwritingMES No with black paint as directed complete all as specified and as directed.
37M&L steel water tube,15 mm bore medium grade,galvanised with all fittings fixed complete to walls and ceilings or laid in trenches/floors etc all as specified and as directed. Make : Jndal/Prakash/Swastik
38M&L for multifunction safety valve cast copper alloy screwed down, high pressure ,screwed both ends for iron pipe or brass ferrule 15 mm dia/bore complete all as specified and as directed. Make : Theta/Dass Pass /Racold/kartar/Leader/Kirloskar.
39M&L water tapecast copper alloyscrewed down, high pressure ,screwed both ends for iron pipe or brass ferrule 15 mm dia/bore complete all as specified and as directed. Make : Theta/Dass Pass /Racold/kartar/Leader/Kirloskar.
40S&F in repair switch piano flush button single pole one way 15 Amp, 240 230 volts conforming to IS 1293-2005 and ISI marked complete all as specified and as directed. Make:Havells/Kinjal/Plaza/Leader
41S&F in repair socket outlet, 3 Pin, 15 Amp flush type 230 volts conforming to IS 1293-2005 and ISI marked complete all as specified and as directed. Make:Havells/Kinjal/Plaza/Leader
42S&F in repair Rubber Gasket flange as per site requirement for 25/50 ltr water heater ( storage type) complete all as specified and as directed.
43S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions15 mm dia/bore complete all as specified and as directed.Make : Theta/Dass Pass /Racold/kartar/Leader/Kirloskar/Zoloto.
44S&F in rep[air top plug15 amps 3 pin , 230 voltscomplete all as specified and as directed.Make:Havells/Kinjal/Plaza/Leader
45M&Lproviding cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) in coping ,bed pates,etc including necessary form work complete all asdirected.