Addn Altn To Air Conditioning System Of Main And Alterate Conference Hall At Kashmir House E In C Branch Under Ge New Delhi Addn Altn To Air Conditioning System Of Main And Alterate Conference Hall At Kashmir House E In C Branch Under Ge New Delhi, GE New Delhi-Delhi

Military Engineer Services-MES has published Addn Altn To Air Conditioning System Of Main And Alterate Conference Hall At Kashmir House E In C Branch Under Ge New Delhi Addn Altn To Air Conditioning System Of Main And Alterate Conference Hall At Kashmir House E In C Branch Under Ge New Delhi. Submission Date for this Tender is 18-08-2021. Air Conditioner Tenders in GE New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

28695430
Corrigendum : Addn Altn To Air Conditioning System Of Main And Alterate Conference Hall At Kashmir House E In C Branch Under Ge New Delhi Addn Altn To Air Conditioning System Of Main And Alterate Conference Hall At Kashmir House E In C Branch Under Ge New Delhi
Open Tender
Indian
Delhi
GE New Delhi
18-08-2021

Tender Details

Addn Altn To Air Conditioning System Of Main And Alterate Conference Hall At Kashmir House E In C Branch Under Ge New Delhi Addn Altn To Air Conditioning System Of Main And Alterate Conference Hall At Kashmir House E In C Branch Under Ge New Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: ADDN/ ALTN TO AIR CONDITIONING SYSTEM OF MAIN AND ALTERATE CONFERENCE HALL ATKASHMIR HOUSE (E-IN-IN-C"S BRANCH) UNDER GE NEW DELHI
Sl. No. Item Description
1Supply, install, testing and commissioning of Air Cooled Variable Refrigerant Volume / Flow (VRV / VRF) Outdoor units (working and standby) with all Inverter Scroll Compressor in each individual unit, preferably all compressors of suitable capacity, air cooled copper condenser coils must have Ocean Black / Blue Fins coatings for corrosion resistance, condenser fan motor shall be weather proof, brushless DC drive, fan shall have lower vibration, motor shall have minimum 10 steps and air flow resistance with protective grill, suitable for 380-420 Volts, 3 Phase + N, 50Hz, AC supply, with Heating-Cooling facilty suitable for 415 + 10% for outdoor and 230 + 5% volts for Indoor units complete with indoor and out door units, controllers, accessories and shall deliver 100% capacity at 43 degree centigrade temperature and shall be suitable for operation upto 50 degree centigrade ambient without tripping or failure, minimum Full load coefficient of performance (COP) must be 4.1 and minimum part load COP must be 7.2, defrost technology,6 bypass valve compressor, including Refrigerant R-410A / R 407C with first charge of refrigerant gas, suitable PCC foundations, including loading / unloading and shifting to floor / terrace and connecting earthing for out-door units from the panel, of following capacities / units, complete all as specified and directed:- MAKE:- O General / MITSUBISHI (Heavy) / TOSHIBA/ Hitachi/ DAIKIN/ BLUESTAR
2Note: 1. Work includes taking down of existing AC plants from its fixed position & depositing safely to MES store yard along with transportation at any distance. 2. The outdoor should deliver the mentioned capacity of 16 HP at 42 deg C outside temperature as per Delhi ambient conditions in summer (Bidder to consider applicable de-ration) 3. The bidder is required to submit NIT specific authorization certificate from the OEM duly signed and stamped. 4. COP at 50% load and at 35 deg C inside WBT should be of minimum of 7.0. 5. Bidder is required to submit OEM rating chart of the quoted outdoor unit for COP and capacity verification to the department 6. The entire work shall be carried out by OEM authorised delar and any civil work required shall be considered in the quoted rate. 7. Contractor and OEM are advised to visit site before quoting rates and arrangement to make sure there is no monkey menace leading to leakage from joints/ pipes. 8 Work includes gas charging of suitable refrigerant complete with Nitrogen testing 9. After completion of work contractor to submit to the department for 03 years AMC from OEM.
3VRF Outdoor Unit 16 HP capacity complete with all accessories
4Indoor Units Hi wall Type 2.0 TR inverter type
5Indoor Units Hi wall Type 1.3 TR capacity inverter type
6Tower Type AC unit 4.0 TR capacity inverter type
7Cassette Type AC unit 2.0 TR capacity inverter type
8Cassette Type AC unit 3.2 TR capacity
9Y/T Joints
10Remote Control Cordless
11Supply install, testing and commissioning of hard drawn copper refrigerant pipes for VRF Indoor and Outdoor units with necessary copper fittings, laid neatly, secured with GI clamps and wall brackets with pipe supports as per technical specifications, at every 1.5 meter interval and at bends including insulation with 19 mm thick class "O" nitrile rubber, UV treatment (coating) for exposed refrigerant piping insulation complete all as required at site as per specifications, of the following sizes:- MKAE:- MANDLEY / UNIFLOW / TOTAL LINE/ MANDEV
1228.60mm (1.125") of thickness 1.219mm (0.048")
1325.40mm (1.00") of thickness 1.219mm (0.048")
1422.20mm (0.875") of thickness 1.219mm (0.048")
1519.10mm (0.75") of thickness 1.219mm (0.048")
1615.90mm (0.625") of thickness 1.219mm (0.048")
1712.70mm (0.50") of thickness 0.914mm (0.036")
189.50mm (0.375") of thickness 0.914mm (0.036")
196.35mm (0.25") of thickness 0.914mm (0.036") NOTE for Sl. Item No. 2.01 to 2.08 here-in-before:- (i)The pipe sizes shall be selected according to the equipment capacities and manufacturer"s specification (ii)If required, soft piping shall only be allowed from refnet to the indoor units in case the same is as per OEM recommendations (iii)Contractor shall submit a detailed schedule of piping both suction and liquid line with detailed shop drawings for approval from Accepting Officer (iv)Necessary leak / pressure test shall be carried out before charging of refrigerant gas (v)All brazing shall be protected against oxidation during soldering / brazing by use of dry nitrogen gas flowing through the tube to remove carbon deposits.
20Supply & fix copper control cum transmission wiring 4 Cx 2.5 sqmm in PVC conduit between indoor & outdoor, indoor units and their remotes. Make- Havells/ polycab/RR
21Supply & fix UPVC drain pipes threaded 25 mm dia and fit clamps at every 1 m along with bends and maintaining slope complete all as specified and directed by Engr-in-Charge
22Supply, install, test and commissioning of out-door type LT distribution board made out of 3.0mm thick CRCA sheet, CPRI approved, double door totally enclosed, weather, dust and vermin proof as per ISwith front and rearopening, suitable locking arrangement, top with sloping canopy having aluminum bus bar of 200Amp capacity for RYB andfor neutral and insulated with insulators, including provision of cable glands, connecting incoming and outgoing cables necessary PCC 1:3:6 type C1 (20mm graded stone aggregate) in foundation and suitable size of angle iron grouted at terrace floor above 300mm from floor level, with and including provision of the following, complete all as specified and directed:- NOTE:- The quoted rate includes necessary internal wiringfor meters, CTs, indication lamps etc and rigid bus bar connections from bus bar to MCCB terminals, connection bus to MCCB. (For out-door unit of Ground Floor and First Floor ACs to be placed / mounted over First Floor terrace). Complete all as specified and as directed by Engr-in-Charge. Make for LT panel- Universal Switch Gears, Havells, ABB
23(a)MCCB, FP, 100Amp rating with microprocessor release, Icu = 16KA, Ics = 100% of Icu with adjustable overload setting (minimum 70% to 100%) - 01 No. (incoming), Make-Schneider/ Siemens/ ABB/ GE/Hager (b)MCCB, TPN, 63Amp with thermal magnetic release Icu = 16KA & Ics = 100% of Icu with adjustable over load setting (minimum 70% to 100%) = 3 Nos. (outgoing)Make-Schneider/ Siemens/ ABB/ GE/Hager(c) Automatic Phase Sequence Corrector 40 KVA- 02 Nos. Make-Universal Switch Gear/Schneider/L&T (e)Digital ammeter of size 96mm x 96mm - 01 No. Make- AE/L&T (f)Digital voltmeter of size 96mm x 96mm - 01 No. Make- AE/L&T (g)R-Y-B phase indicator lamps LED type - 1 set. Make-AE /L&T (h)Suitable rated CTS
24M&L for laying of XLPE PVC sheathed armored cable 35 sqmm 4 core complete all as specified and as directed by Engr-in-Charge. Make-Gloster, Havells, polycab
25M&L for fixing of sheet metal enclosureAC box along with single pole MCB SP 32 Amp. Complete all as specified and as directed by Engr-in-Charge
26S&F Automatic Voltage Stabilizer 5 KVA ISI Marked digital wall mounted input voltage 10V,260V, rated output voltage Stabilizer, rated current 18.2 Amp, insulation class B suitable for 2 Ton AC with inbuilt electronic over load trip, protection against high/ low voltage & timer for 10 Seconds, efficiency more than 97% all as specified by Engr-in-Charge.
27M&L for laying of light grade GI pipe 40 mm dia along with iron saddles complete all as specified and as directed by Engr-in-Charge
28M&L for Earthing complete with Copper earth plate 600 x 600 x 3.15 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5mr below normal ground levelconnected to25x4 mm GI strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washersfrom earth pit to test point with protection GI pipe of size 50mm dia light grade and providing masonry enclosureand watering pipe of dia 25 mm including wiremesh steel funnel, complete all as specified and directed by Engr-in-charge. Make of GI Pipe : Prakash/Jindal/TATA Note: 1. Copper strip/GI strip 7.5 mtr included in the quoted rate from earth pit to test point. 2. After GI/Cu strip final connection shall be terminated to the equipment either by Cu strip or if not feasible then Copper cable 6 sqmm single core upto final length not greater than 45 meters for copper cable 6 sqmm and rate quoted shall be deemed to be included in the above quoted rate
29Supply and fix CABLOFIL wire meshed stainless steel (SS304) cable tray 54mm (h) x 200 mm (w) complete with nuts bolts washers, clamps, brackets, support any type along with hole fastener and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends. Make- Legrand Cat Part No- CF54/200 (000098)/Schneider/ABB/Havells