Improvement / Provision Of Ht Electric Supply System At Mrs And Associated Works Services At Af Station Bareilly Improvement / Provision Of Ht Electric Supply System At Mrs And Associated Works Services At Af Station Bareilly, Bareilly-Uttar Pradesh

Military Engineer Services-MES has published Improvement / Provision Of Ht Electric Supply System At Mrs And Associated Works Services At Af Station Bareilly Improvement / Provision Of Ht Electric Supply System At Mrs And Associated Works Services At Af Station Bareilly. Submission Date for this Tender is 21-08-2021. Overhead Line Tenders in Bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28695373
Corrigendum : Improvement / Provision Of Ht Electric Supply System At Mrs And Associated Works Services At Af Station Bareilly Improvement / Provision Of Ht Electric Supply System At Mrs And Associated Works Services At Af Station Bareilly
Open Tender
Indian
Uttar Pradesh
Bareilly
21-08-2021

Tender Details

Improvement / Provision Of Ht Electric Supply System At Mrs And Associated Works Services At Af Station Bareilly Improvement / Provision Of Ht Electric Supply System At Mrs And Associated Works Services At Af Station Bareilly

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-08-2021

Key Value

Document Fees
INR 1000 /-
EMD
INR 183000.0 /-
Tender Value
INR 1.08 Crore /-

BOQ Items

Name of Work: IMPROVEMENT /PROVISION OF HT ELECTRIC SUPPLY SYSTEM AT MRS AND ASSOCIATED WORKS SERVICES AT AF STATION BAREILLY
Sl. No. Item Description
1Schedule "A" Part I : Building Works
2Demolition of Brickwork of stone/boulder masonry,built in cement mortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
3Taking down Chowkatts or frames with shutterexc 1.5 sq. m but n exc 4 sq m and removing complete all as specified and directed.
4Dismentling asbestos cement (corrugated, plainsemicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
5Demolition of reinfoced cement concrete Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete all as specified and directed.
6Separating, scraping and cleaning of reinforcement (Demolition of concrete measures seprately) complete all as specified and directed.
7Dismantling framed trusses n exc 10m span complete all as specified and directed.
8Demolition of un-reinfoced cement concrete Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete all as specified and directed.
9Excavating over area (Manually)in soft/loose soil over areas, n exc 1.5m deep and gettingoutcomplete all as specified and directed.
10Excavating in trenches (maually) , n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
11M& L for Cement concrete 1:3:6, type C2 (40 mm graded aggre-gate) in foundations, filling and mass concrete complete all as specified and directed.
12M&L for Brick work with sub-class `B" bricks, straight or curved on plan exc6.0 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
13M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
14M & L for 10 mm thick renderingwith cement mortar 1:6on fair faces of brick work or concrete surfaces complete all as specified and directed.
15M & L for providing cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintel upto1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lasing courses, parapets and railing upto 60 cm in height, coping /pole coping, kneelers, apex stones, bed plates, water troughs and like including weathering, slightly rounded or chamfered angles and throating complte all as specified and directed.
16Removing excavated soiln exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
17Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
18M&L for prepration ofnew plastered Surfaces of wall and applying two coat ofoil bound distemperover one coat of primer complete all as specified and directed.
19Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
20M & L for providing 25 mm thick cement concrete (1:2:4) type B-O using 12.5 mm graded crushed stone aggregate as in floor etc surface finished even and fair complete all as specified and directed.
21M & L for Screed bed or bedding layers of mortar 15mm thick in Cement mortar (1:4) for laying floor finish complete all as specified and directed.
22M & L for glazed ceramic digitalcoloured/printed tiles in vertical surface600 X 300X 7mm thickmatch to floor tile set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick plastering in CM 1:4 complete all as specified and directed.
23M & L for marble makrana whitetiles of size 1.8 m x 1.2 m x 18 mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and granding upto granite polishing complete all as specified and directed.
24M & L for marble makrana white 13 mm thick marble tiles machine cut in skirting/dado laid over cement screed and jointed with grey cement slurry including cutting and polishing over and including 10 mm thick plastering in CM 1:4 complete all as specified and directed.
25S&Fof Armstrong Mineral Fibre Acoustical Suspended Ceiling System with ANF Angled Tegular edge tiles with Armstrong Prelude 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.5, Light Reflectance =85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 30%. The tile shall be laid on Armstrong Prelude 32 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 8.5 Kgs/M2 (as per standard installation layout mentioned below) & pull out strength of minimum 100 Kgs.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall.
26S & F for rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as specified and directed.
27S&F for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (TCT) of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws ascomplete all as specified and directed.
28S&F for pre painted galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick (TCT) for wall cladding of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed withself thread screws complete all as specified and directed.
29S& F for rolled mild steel framed work as inas of angle or other section with gusset plates, GDE Fe410-0 or Fe, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doo0rs etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
30S&F for rolled mild steel work in plates (plain or chequered) Fe 410W (gde-E-250) quality Achannels. Square cut or notched ) (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all asw specified and directed.
31M & L for preparation of new or previously untreated steel and iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
32M&L for Sand filling under floors including watering and consolidation complete all as specified and directed.
33M&Lstone dustfilling under floorsincluding watering and consolidation complete all as specified and directed.
34M & L for Sub base of 100mm thick with mooram / red bajri(20-40mm) rolled to consolidated to required gradient and camber complete all as specified and directed.
35S & F UPVC door with framewhitecolour including 08mm toughen glass with eaching wrighting (as directed) and logo (size as directed) at top &08mm acp sheet at bottom,Drainage, Coextruded Bead, T-Sash, Bead Shape, Fittings Suppli, Hinge Color,Handle ,inbuiltlock , Door Backset, Espag, floor spring etcMaterial, Silicon Sealant complete all as directed and specified.
36S & F UPVC window including frame white colour three track with 02 shutter glazed and one mesh shutter including Casement ,8mm Toughned glass, S/S wire mesh, 08 mm acp sheetfor fixed portionReinfor cement Drainage, Coextruded Bead, Flyscreen Colour white, Slider O/F, Slider Sash, Interlock Fittings Suppli, Handle, Slider Backset, Espag Material, Roller Supplier, Silicon Sealant complete all as specified and directed.
37S & F UPVC fixedwindow including frame white colourglazedincluding Casement ,08mm Toughned glass, 04 mm acp sheetfor fixed portionReinfor cement Drainage, Coextruded Bead, Flyscreen Colour white, Slider O/F, Slider Sash, Interlock Fittings Suppli, Handle, Slider Backset, Espag Material, Roller Supplier,Silicon Sealant complete all as specified and directed.
38S&F Aluminium composite panels (ACP), made of aluminium composite material , ACE series 6mm thickflat panelssheets used for external cladding fixed to any type of structure including all back supports, fixing material, finishing material, joints, laps, screws etc. Colour and shade as slected by GE complete all as specified and directed. Make : Aludecor, Alstone.
39M & L for providing, precast cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) Set in cement mortar1:6, in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, plastes, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers,m weatherings, throating etc. and setting in mortat complete with joints to match complete all as specified and directed.
40M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed.
41M & L for providing 18-20mm thick black granite stone slab including sanwich type (IInd layer of 20mm at front) (table rubbed and polished) bull nosed as on shelves / cooking plateform /WHB over and including screed bed 20mm thick in cm (1:4) set jointed in neat cement slurry and pointed in white/coloured cement to match the shade complete all as specified and directed.
42M&L for 2nd class hard wood for Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints,supplied and fixed complete all as specified and directed.
43M&L for IInd class hard wood Plain framed, panelled factory made shutter 35mm thick(two panel 12 mm thick BWP) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial venneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
44M & L for glazed and skeleton 35mm factory made shutters 2nd class hard wood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. cla-use 8.20 (a); supplied and fitted to chowkats complete all as specified and directed.
45S&Ffor Aluminium alloy, anodised, 300 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed
46S & F 100mm long Stainlesssteel butt hinges, medium type,and fixed with stainless screw complete all as secified and directed.
47S & F for 125 mm extruded aluminum ally classic handles, fabricated type., anodised fixed withstainless 04 nos screw complete all as specified & directed
48S&F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed with bright stainless steel bolt and fixed complete all as specified and directed.
49S&F mild steel 300mm, ordinary rat tail rod patttern springs includding roller and roller plate complete all as secified and directed.
50M&L for painting to new wooden surfaces of any description not otherwise described over 10cm wirdh or girth, with two coats of synthetic enamel paint (1st quality), over one coat of pink primer including preparation of surface complete all as specified and directed.
51S&F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
52M&L for 18/19mm Prelaminatd particle board, interior grade, glossy finish prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
53S&F 100mm long Aluminium anodized Hasp and staple, including bolt to hinge plate and fixed with screws complete all as specified and directed.
54S&F 150mm long Aluminium handles, cast type, anodised complete all as specified and directed
55S&F Continuous (piano) hinges, mild steel, bright finish Width of flaps (When open) in 40 mm or electrogalvanised complete all as specified and directed.
56M&L Moulding IInd class hard wood n exc 6 Sq cm sec area as in cornices, picture rails and the like complete all as specified and directed.
57S&F 0.5mm thick exterior grade Stainless steel/Chrome plated lettering letter height of 300mmthickness 30mmincluding fixingarrangement /bolt complete all as specified and directed.
58S&F 0.5mm thick Exterior grade stainless steel / Chromium plated, air force logo with required colourincluding fixing bolt height of 600mm complete all as specified and directed.
59M&L for Point wiring complete with multi-starnded copper conductor 1.5 Sqmm size PVC insulated unseathedcable, 1100 volt grade, confirming to IS 694 & colour code in counduit system of wiring, drawn in and including medium grade PVC conduit not less than 20 mm dia concealed including cutting chases and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size, of not less than 1.6 mm thickfactory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and cup wachers with all accessories including single core solid copper conductor 1.5 Sqmm size solid PVC insulated unseatheds cabe as earth wire to common earth dolly drawn in same conduit complete all as specified and directed .
60(a) One light point controlled by one, one way switch
61(a) One 3 pin socket outlet, 5/6 amps, on independent board.
62All as per item No. 59 above but with copper conductor 2.5sqmm for one 3 pin socket outlet, 15 amp on independent board complete all as specified and directed.
63S & F of modular type switch 1 way, 6 Amp, 1 module complete all as specified and directed.
64S & F of modular type socket,6 Amp, 1 module complete all as specified and directed.
65S & F of modular type socket,6/16 Amp, 2 module complete all as specified and directed.
66S & F of modular type switch 16 Amp, 1 module complete all as specified and directed.
67S & F of modular fan regulator 120watt, 2 module complete all as specified and directed.
68S & F for LED luminaire 600 mm X 600 mm, 35/36 watt, 230 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper cable of suitable sise complete all as specified and directed.
69taking down existing copper /aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc, removing materials to storefor keeping in safe custody or for taking credit (Credit for above items should be made as per conditions seperately) and making gooddistrurbed surfaces of wall, floor etc complete all as specified and directed
70Schedule "A" Part II : Electric Supply Works
71Supply,laying, jointed and testing HT cable XLPE insulated, screened, PVC bedded, galvanised steel strip, armoured,electric power cables with aluminium conductor, 11000 volts (Earthed) grade, laid in trenches/ drawn through pipe/ poles or laid under road / drains / pathcomplete ofcross sectional area 95 sq. mm 3 core complete all as specified and directed. Note :- HT cable drum length 1X900 RM & 2x600 RM all as directed by Engr-incharge
72Taking down of old U/S UG HT cable 95 SQMM 3 Core complete all as specified and directed.
73M & L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed..
74Supply and fix cable jointing kit for 11 KV( Earthed), grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmmcomplete all as specified and directed.
75Supply and fix cable jointing kit for 11 KV (Earthed)grade cable for indoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmmcomplete all as specified and directed.
76Excavation in trenches (manually) not exc. 1.50 m wide and not exc. 1.50 m in depth for laying cables or foundation of electric pole / Stay assembly and getting out in soft / loose soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.
77M & L for laying of course sand free from sharp materials as in filling in trenches for cable protection, laid to a uniform thickness of 23 cm (15 cm under the cable and 8 cm over the cable) and gently punned down to 18 cm thickness as required complete all as specified and directed. Note :- Punned down thickness shall be measured for payment purpose.
78Supply and laying un-reinforced precast concrete cable cover class HV type-I flat size 300 mmx180mmx40mm complete all as specified and as directed
79M & L for laying brick as in protection covers over cables using well burnt sub class "B" old size bricks in trenches over sand cushioning complete all as specified and directed.
80Supply, erecting and fixing in true vertical position, steel tubular swaged pole type 410 SP-55 (11 meter long) complete with CI base plate, pole cap / finialtaper plug,bolts, nuts and washers,welded reduced section and longitudinal weld throughout entire lenght of pole complete with including 2 coats of black bituminous paint externally up to plantingdepth and remaining portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.
81Supply, erecting and fixing in true vertical position, steel tubular swaged pole type 410 SP- 22 (8.5 meter long) complete with CI base plate, pole cap / finialtaper plug,bolts, nuts and washers,welded reduced section and longitudinal weld throughout entire lenght of pole complete with including 2 coats of black bituminous paint externally up to plantingdepth and remaining portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.
82M&L for cable path indicator for HT 11000 Volts made of CI plate of minimum 150mm dia, 4mm thick duly indicating cable size & voltage fixed to MS angle 30x30x6mm, 900mm long with bolts & nuts, the angle shall be planted in ground for 400mm depth, and embedded in PCC (1:3:6) type C1 foundation of size 200x200x600mm complete including necessary excavation & earth work, painting the exposed portion of the indicator & MS angle with two coats of synthetic enamel paint over a coat of zinc chrome primer all as directed.
83Excavation in trenches(manually) nexc for 1.5 mtr wide & exc 1.5 mtr as part there offin depthall as specified and directed.
84Supply, Installation, testing and commissioning of HT Panel 11KV, 3 Phase , 50 Hz, Indoor type having provision of one number incoming,one number out gonig and one number buscoupler horizontal, draw out, Vacuum Circuit Breaker (VCB) 630 Amps, horizontal isolation type motor oparated spring charged having rupturing capacity 18.4 KAfor 1 Sec by connecting to the HT Panel board with help of copper bus bar of suitable size duly enclosed in CRCA Frame and Comprising of the following :-(A)INCOMING:-01 Nos. (a) Mechanical interlock and automatic safty shutter door. (b) Isolating Plugs. (c)Assembly of three vacuum interrupters complete with epoxy support insulator and self-alingning finger type isolating contacts. (d) Hand / Motor 230 volts AC charged independent spring closing / tripping trip free operating mechanism with manual closing tripling push buttons and mechanical breaker " closed / open" spring charged / discharged indication. (e) Mechanical operation counter . (f) Electrical releases coil of 24 volts DC.
85(g) Shunt trip coil 24 Volts DC. (h) Auxiliary switch. (j) 230 Volts AC single phase 80 watt rated strip type heater with toggle switch and thermostat - 01Nos. (k) Cable termination 1x3Cx 95 Sqmm XLPE. (l) Digital Amp Meter flush type 0 -100/50 Amps CT Operated with CT having dual ratio 100 - 50/5+5. (m) Numerical type 3 phase over current and earth fault relay and CT rating 5 Amp operated on auxillary supply 24 volts to 110 volts AC/DC programmable. (n) On / Off / trip indications. (o) 3 Phase RYB indication lamp. (p) Trip circuit healthy indication lamp. (q) Tri-vector energy meter class 0.5 with Rs 485 Port. (r)Cable gland of suitable size. (s) Cubical illumination lamp-01 (t) Potential transformer copper winding ratio three single phase of 11KV / v3 /110 V/v3, class 0.5-3, with burden 50 VA and insulation level 28/75 conforming to IS - 3156. (u) Resin cast CT ratio 100-50/5+5 class1.0, 5P, 10 burden as per IS.
86(B) OUTGOING :- 01 Nos. (a) Mechanical interlock and automatic safety shutter door. (b) Isolating Plugs. (c)Assembly of three vacuum interrupters complete with epoxy support insulator and self-alingning finger type isolating contacts. (d) Hand / Motor 230 volts AC charged independent spring closing / tripping trip free operating mechanism with manual closing tripling push buttons and mechanical breaker " closed / open" spring charged / discharged indication. (e) Mechanical operation counter . (f) Electrical releases coil of 24 volts DC. (g) Shunt trip coil 24 Volts DC. (h) Auxiliary switch. (j) 230 Volts AC single phase 80 watt rated strip type heater with toggle switch and thermostat - 01Nos. (k) Cable termination 1x3Cx 95 Sqmm XLPE. (l) Digital Amp Meter flush type 0 -100/50 Amps CT Operated with CT having dual ratio 100 - 50/5+5. (m) Numerical type 3 phase over current and earth fault relay and CT rating 5Amp operated on auxillary supply 24 volts to 110 volts AC/DC programmable.
87(n) On / Off / trip indications. (o) 3 Phase RYB indication lamp. (p) Trip circuit healthy indication lamp. (q) Tri-vector energy meter class 0.5 with Rs 485 Port. (r)Cable gland of suitable size. (s) Cubical illumination lamp-01 (t) Resin cast CT ratio 100-50/5+5 class1.0, 5P, 10 burden as per IS.2705
88(C) BUS COUPLER:- 01Nos. (a) Mechanical interlock and automatic safety shutter door. (b) Isolating Plug (c)Assembly of three vacuum interrupters complete with epoxy support insulator and self-alingning finger type isolating contacts. (d) Hand / Motor 230 volts AC charged independent spring closing / tripping trip free operating mechanism with manual closing tripling push buttons and mechanical breaker " closed / open" spring charged / discharged indication. (e) Mechanical operation counter . (f) Electrical releases coil of 24 volts DC. (g) Shunt trip coil 24 Volts DC. (h) Auxiliary switch. (j) 3 Phase RYB indication lamp. (k) Selector switch
89NOTE Cost for Modification (Material & labour reqd) for 11KV,630 Amps, TP, Bus bar with air insulated,made of CRCA Sheet for connection with existing VCB deemed to be included. No extra amt to be quoted & paid.
90Supply,laying, jointed and testing LT cable XLPE insulated, screened, PVC bedded, galvanised steel strip, armoured, heavy duty cable with aluminium conductor, 1100 voltslaid in trenches/ drawn through pipe/ poles or laid under road / drains / path / complete ofcross sectional area 16 sq. mm 4 core complete all as specified and directed.
91Supply and fix LED Flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection ,with impact and corrosion resistant complete with driver and lamp complete all as specified and directed..
92S&F three corePVC insulated flexible cable cord 1.5 sqmm multi stranded copper conductorflexible cables 1100 Volt grade, drwan in sidepoles complete and making connection from pole box to Flood light all as specified and directed.
93S & Fshock proof rust proof fire retardant non transparent Kiosks pole box of size 310x 210x 120mm made of Engeineering plastic on piece moulding, for out door duty, with four nos of insulated alunminium bus bar of 60 amps capacity mounted on unbreakable insulators. 6A MCB SP with aluminium lugs of suitable size 16 sq mm . including 02 Nos 40x3mm FI clamps nut,bolts washer etc complete all as specified and as directed.
94Supply and fixinglightning arrestor of 9 KV metal oxide (Gap less type) heavy duty, self supporting station class having nominal discharge current 10 KA (peak), class II suitable for 11 KV HT over head network including necessary connections with HT over head linescomplete all as specified and directed.
95Supply and fixing of air break switch gang operated (GOD) triple pole with drop out fuses mechanically operated, mounted on insulators 12 Nos & steel frame with operating mechanism & operating rod of GI pipe 25mm & medium grade with necessary clamps to be operated from ground level 11 KV grade working pressures and current upto 400 Amps complete all as specified and directed.
96Supply and Fixing cross arms, bracings, supports, clamps and back plates fabricated from structural steel sactions including MS nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directedand inclusive of one primer coat, one under coat and one finishing coat of almunium paint complete all as specified and as directed.
97M&L for Shifting/relocation of existing 11KV VCB 400/630Amps capacity including disconnection necessary electrical connections and relay out of VCB with proposed VCB for symmetry cost of modification of foundation and replacement of nut/bolts for connections of cable/earth strip after reinstallation connection to be include to unit rate cost of reconnection of cable and auxillary supply, testing for operation after reinstallation for smooth operation , caliberation of existing VCB relays after reinstallation by MVVNL authorised agency. complete all as specified and directed.
98Taking down of existing 11KV VCB/OCB 400/630 Amps capacity including disconnection necessary electrical connections and using T&P etc for lifting & transporting from existing location to MES Store Yard complete with in AF Stn Bareilly not more than 3 KM distance complete all as specified and directed.
99M&L for Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to copper earth strip of 20x3mm size by means of bolts, nuts, check nuts and washers of copper/brass and connected from earth plate electrodeearthing test point,GI tubing 40 mmbore medium grade protection pipe,GI watering pipe 20 mm bore medium grade with 40 mm thick with PCC 1:3:6 type C1 chamber, MS funnel and wire mess, CI cover, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of Schedule Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion. Note :-1. Earth lead& protection pipes lenght upto & including 7.50 meter shall be deemed to be inclusive in quoted rate2.Earth filling shall be done by vegitable soil. 3. Soil should be free from stone , boulders, aggregate, gravels etc.
100S&F copper earth strip of size 20x3 mmfixed to wall or batten or recess or chases or buried in ground complete all as specified.
101Supply and fix High Voltage synthetic rubber insulating Mat, thickness 2.5 mm for up to 11 KV, with ISI marked CPRI tested and ISO & CE certified. Class-B category-III, As per IS: 15652:2006 with green colour strip all as specified and directed.Make: Electromat/Jyoti
102SM & L of Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
103M & L of Danger notice plate of 1.6mm thickmild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
104Supply and Fixingof pin type Porcelain, vatreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts gradecomplete all as specified and directed.
105Supply and Fixingof Disc type Porcelain, vatreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts gradecomplete all as specified and directed.
106Supply and FixingACSR Aluminium conductor with steel reinforced, binding on insulator and making busbar for four pole structure complete all as specified and directed.
107M & L for GI tubing medium grade including necessory fittings of size 80mm, laid in trenches /fixed with poles as in mechanical protection to UG cable .all as directed.
108M & L for GI tubing medium grade including necessory fittings of size 50mm, laid in trenches /fixed with poles as in mechanical protection to UG cable .all as directed.
109Schedule "A" Part III : Road hardstanding Fencing & Gate
110Surface excavation inSoft/loose soil n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out complete all as specified and directed.
111M & L for Sub base 100mm thick with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed.
112M & L for 100mm thick Cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) complete all as specified and directed.
113M & L for 50mm thick Cement concrete 1:2:4type B-1 (using 20mm graded aggregate) complete all as specified and directed.
114M & L for Forming construction joints 30 mm deep x 10mm wide filled with ceiling compound Gd "A" complete all as specified and directed.
115Dismantling post struts any dsecription incl taking out embeded portion & making good distrubed ground ,post/ iron postembeded in conctete /masonery etc complete all as specified and directed
116Dismantling fencing wire mesh/ chain link fencingany type complete all as specified and directed
117M & L for plain cement concrete 1:4:8 type D-2 (using 40 mm gradedstone agg) in foundations, filling and mass concrete complete all as specified and directed.
118S & F for mild steel work in Joist, channel, angle, tee/flat or othersections, includingcuttingtops to shapes as directed drilling holes ,notching for wire etc and simillar work conforming toof Fe 290 Gde-E-165 etc all as specified and directed
119S & F for 4mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed.
120M & L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work or concrete surfaces and finished even and fair without using extra cement complete all as specified and directed.
121M&L for preparation of new or untreated surface of wall and applying two coats of cement base paint over one coat of primer complete all as specified and directed
122Dismantling structural steel work including doors, gates, rolling shutterbut excluding framed truss etc. complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail