Repair / Maint Of Ac, Water Coolers, Refrigerators, Voltage Stabilizer, Geysers Of Various Capacity And Connected Items At Af Stn Darbhanga Under Ge ( Af ) Bihta, Darbhanga-Bihar

Military Engineer Services-MES has published Repair / Maint Of Ac, Water Coolers, Refrigerators, Voltage Stabilizer, Geysers Of Various Capacity And Connected Items At Af Stn Darbhanga Under Ge ( Af ) Bihta. Submission Date for this Tender is 26-08-2021. Voltage Stabiliser Tenders in Darbhanga Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

28684017
Corrigendum : Repair / Maint Of Ac, Water Coolers, Refrigerators, Voltage Stabilizer, Geysers Of Various Capacity And Connected Items At Af Stn Darbhanga Under Ge ( Af ) Bihta
Open Tender
Indian
Bihar
Darbhanga
26-08-2021

Tender Details

Repair / Maint Of Ac, Water Coolers, Refrigerators, Voltage Stabilizer, Geysers Of Various Capacity And Connected Items At Af Stn Darbhanga Under Ge ( Af ) Bihta

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Aug-2021 Corrigendum No 1 BOQ 19-08-2021
2 19-Aug-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : Repair/Maint of AC, water coolers, Refrigerators, voltage stabilizer, Geysers of various capacity & connected items at AF Stn Darbhanga under GE (AF) Bihta
Sl. No. Item Description
1Labour only for collecting the complaints of various /departments of 7C & MU and all other AOR of AGE B/R (Darbhanga) pertains tosplit/window type Acs /desert cooler/ water cooler/ceiling fans/exhaust fan/geyser of any capacity/make from concern JE of AGE E/M (Darbhanga), attendending these at site to asses the actual fault after opening of any heating /cooling appliances and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by nameto concern JE all as directed. (Spare parts shall be measured and paid separately under appropriate items)
2Material and labour taking down desert cooler from foundation, dismantling, opening the same and complete servicingby scrapping of rusted/deposited materials from the desert cooler body, replacement of wornout, MS Nut bolt, wahser etc, oiling, greasing of fan bearings, bushes etc.providing new GI/MS sheetincluding necessry mechinary works suchas cutting/welding/finishing etc painting the whole body internally& externally of the desert cooler with two coats of syntheticenamel paint of desire or existing colour.over a coat of red oxide primer after perration of surface.Desert cooler shall be made fully functionalto the entire satisfaction of Engineer-in-charge and re-installedat same or any other location as directed by Engineer-in-charge complete all as specified and directed. Note : (i) Spare requiredshall be measured and paid separately under respective items.
3Supply &fixing ,tesing and commissioning of submersible pump of desert cooler single phase 18watt220 volt 50 Hz of existing size & specification including taking out the old unserviceable one all as specified and directed.Make- Crompton Greaves/Bajaj//Usha/Khaitan
4Supply and fixing ,tesing and commisiioning of Motorsingle phase 150 watt220 volt 50 HZ of desert coller of existing size and specification including taking out the oldunserviceable one completeall as specified and directed Make- Crompton Greaves/Bajaj//Usha/Khaitan
5Supply and fixing fan500 mm sweep(Set of threeblades) for desert cooler of existing specification including taking out the oldunserviceable oneall as specified and directed
6Supply and fixingCooling pad (Grass) with wire mesh square shape fixing all the side as persample including taking out the old one all as specified and directed
7Supply and fixingflexible PVC pipefor water circulation on grass pad connected through Submersible pump to cooler top end Cooling pad (Grass)including PVC elbow and Junction box as per existingsample including taking out the old unserviceable one complete all as specified and directed
8supply and fixingstepped Rotary switch of existing size& specificationincluding taking out the old unserviceable one complete all as specified and directed. Make:HAVELLS/PLAZA/CG/SSK
9Supply and fixing switch plano flush button single pole one way 6 Amp, 240 Voltsincluding taking out the old unserviceable one complete all as specified and directed. Make:HAVELLS/PLAZA/SSK/CG
10M & L for rewinding of exhaust/kitfan of desert cooler with super enameled copper winding wire of same size/gauge as per existing one and also including replacement of wornout nut, bolt, washers, split pin etc., re assembling and testing on completion complete all as specified and directed.
11Supply and fixingTop plug6 amps 3 pin , 240 Volts complete with connecting PVC 3 core flexible copper wire of maximum 2 m length of suitable capacityincluding taking out the old unserviceable one complete all as specified and directed Make:ANCHOR/HAVELLS/PLAZA
12Material and labour for disconnect electric connection, taking down the air conditioner (Split/Window), Water Cooler and Refrigerator including stabilizer of any make and capacity. Servicing complete by cleaning inside, cleaning of filter, remove dust from body, tightening of loose nut bolt, washer, rubber gas kit and tightening of loose wiring, loose connection, replacement of wornout, nutbolt, washers, gaskits etc and necessary cutting, welding/ soldering works and replacement of rusted body with new MS/GI Sheets of existing specification and madethe equipment fully functionaland re-installation in position and testing complete all as specified and directed by Engineer-in-charge. Note: spare parts will be measured and paid separately under the respective items.
13Material and labour for detection and rectification of leakages in gas lineof 1.5 Ton/2.0 Ton window / split type AC of any model and make by necessary brazing and ensuring the complete systems leak proof including checking the system and replacement of required spare parts and charging with appropriate quantity of refrigerant gas R-134 A, testing for smooth functioning of AC complete all as specified and directed.Note: Spare parts, if required will be measured and paid separately under the supply of respective items.
14Material and labour for taking down thewindow /Split type AC taking out the unserviceable/wornhermetically sealed unit compressorfrom window /Split type AC and replacement with new one compressor (company packed) suitable for existingmodel/make of capacity 1.5 TRsplit/window type AC including brazing with suction and discharge line, checking the system for leak proof andcharging appropriate qty of refrigerant gas R-134 A after makingvacume complete systemand testing the AC for proper functioning all as specified and directed.Make:Kirloskar/ Techumesh/ Carrier / Blue Star/LG/Sri-ram
15All as per item 14here-in-before above but of Capacity2.0 TRwindow / split type AC
16Supply and fixing the following spare parts required in repairs of equipments taken down for servicing videitem No 10 here in above including dismantling, opening the equipments, assembling and testingcomplete all as specified and directed by Engineer-in-charge.Note : All the repairs shallbe carried out at AGE E/M store yardAGE(E/M) DBG including transportation of equipment from site to yard and vice- versa and re-fixing at the same location at site. (a) Cooling coil complete with fins made of copper suitable for 2Ton/1.5 Ton capacity Window/Splittype AC.ofr existing size and specification. Make : LG/Voltas.
17(b) Condensing coil complete with fins made of copper suitable for 2Ton/1.5 Ton capacity Window/Splittype AC.of existing size and specification all as directed.. Make : LG/Voltas.
18(c) Fan motor for AC upto 2 ton. Make: Voltas/LG
19(d) Fan mortor for water cooler upto 120 Ltr capacity. Make:- CG/Kirloskar
20(e) Fan blade for AC"s blower/ water cooler motor and all as per sample approved by Engineer-in-charge..
21(e) Copper condensing coil suitable for water cooler upto 120 Ltr capacity all as directed . Make : Voltas/Blue Star.
22(f) Copper cooling coil suitable for water cooler upto 120 Ltr capacity all as directed. Make : Voltas/Blue Star.
23(g)Brass chromium plated water outlet tap for water cooler upto 120 Ltr capacity all as directed. Make : Voltas/Blue Star.
24(h) Front grillfor windowfor 2Ton/1.5 Ton capacity AC all as directed.
25(i) copper valve for Liquid line for ACs upto 2Ton capacity all as directed.
26(j) Copper valve for refrigerant line for ACs upto 2Ton capacity all as directed.
27(k)Insulation foam heavy duty for ACs refrigerant line all as directed..
28(l) Capilary tube for water cooler/ refrigerator/AC of exiting specification and size all as directed.
29(m)Vegitable tray upto 320 Ltr capacity refrigerator of existing specifications and size all as directed.
30Taking down unsv Voltage stabilizer of 3-5 KVA single phase and servove stb 5 kva repairing including servicing all as directed by Engineer-in-Charge. (a)Relay timer 24 Volt, 5 Amp. (b)Volt meter 0-300 Volt. (c)Connector. (d)Capacitor existing capacity. (e)Auto cut kit. (f)Indicator lamp.
31Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron strip 32X6mm , (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle completeall as specified & directed by Engineer-in-Charge. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
32Material and labour for taking down of ceiling fan/ exhaust fan from ceiling/wall any type and make and replacement of wornout, steel split pin, rubber reel, washer, screws, nut bolts etc. Greesing/ oiling of the fan including rectifying the defective wiring, cleaning complete and made functional the same, refixing in position and testingcomplete all as specified and directed by Engineer-in-charge. Note : Item required repairs shall be measured and paid separately under respective items.
33Supply and fixing the following items incoporated in repairs above item No 20 abovecomplete all as specified and directed by Engineer-in-charge. (a) Fan clamp made of SS.
34(b) Fan capacitor 2.5MFD Make: Philips/Bajaj
35(c)Fan capacitor 4/3.15MFD. Make: Philips/Bajaj
36(d)MS down made of GI 15mm dia, 1Ft long.
37(e) Aluminium fan blade 1200/1400mm sheet. Make : Orient/USHA
38(f)MS mounting clamps for Exhaust fan with frame suitable upto 300mm/450 mm sweep.
39(g)Exhaust fan blade made of SS upto 300mm/450 mm sweep.
40Material and labour for dismantling/ opening complete fan obtain from item No 15 above, assembling and testing complete after the following repairs : (a) Supply and fixing fan bearings Make : SKF and all as per existing.
41(b) Supply and fixing gun metal from bushes all as per sample.
42Material and labour for dismantling, opening complete Fan obtain from item No 20 and rewinding the same with super enamel copper conductor of suitable size and meet to original specifications & speed etc. Using proper insulation and varnish, sleeves etc asssembling and 8hrs continous testing before refixing at site complete all as specified for the following sizes : (a)Ceiling Fan 1200/1400mm sweep. Note : (i) Rewinding/ repairs of fans shall be ensured to be carried out at AGE E/M store yard including transporation charges to and from. Note : (ii) Item required for repairs shall be measured and paid separately from above item No 20 (a) to (e).
43(b)Exhaust Fan 450mm/300 mm sweep
44(c) Wall mounted/ Padestern Fan 450mm sweep
45Material and labour for replacement of the following items required for repairs of electric water heater taken down videitems No 42 here-in-before complete all as specified and directed by Engineer-in-charge. (a)Electric water heater element 2/1.5KW of existing size and specification and make all as directed.
46(b) Apparatus (Syphon assembly) plate of existing size and specification and make all as directed.
47©Thermostate switch 30-70ºC ranging.of existing size and specification and make all as directed.
48(d)Copper vessal (inner tank) of weighting 3.5kg suitable for water heat 25 ltr capacity of existing specifications and make complete all as directed..
49(e) SS vessal (inner tank) suitable for 25ltrs capacity water heater of existing specifications and make comlete all as directed.
50(f) Copper vesal (inner tank) of weighting 4.5kg suitable for 50ltrs capacity water heater of existing specifications and make complete all as specified and directed.
51(g) S vessal (inner tank) heavy duty suitable for 50ltrs capacity water heater.
52(h) Indicator lamp neon type 230w of existing specifications and make complete all as specified and directed.
53Supply and fixing running capacitor 80/100 mfd + / - 400 V AC, Suitable for1.5/2.0 TR window / split type AC including taking down unserviceableone complete all as directed. Make : Asian /Bhel / GE / Crompton Greaves.
54Supply and fixing starting capacitor 40/60mfd +/-5% 400 V AC Suitable for1.5/2.0TR window /split type AC including taking down unserviceable one complete all as directed.Make : Asian /Bhel / GE / Crompton Greaves..
55Supply and fixing over load relay including taking down unserviceable one coplete all as directed,Make: - Indofoss/Shri-ram/Usha
56Supply and fixing thermostat switch ( DT 50-1052), suitable for 1.5 Ton/2 Ton split /window type AC. including taking down unserviceable one complete all as directed. Make: - Indofoss/Shri-ram/Usha
57Supply andfixing blower/Propeller fan motor single Phase 230 V AC, 50 Hz of existing capacity, specification for indoor unit including taking down unserviceable one complete all as directed.Make: Universal / Compton Greaves/Air Fresh.
58Suppy and fixing blower/Propeller fan motor single Phase 230 V AC, 50 Hzof existing capacity,specifications for outdoor unit including taking down unserviceable one complete all as directed.Make: Universal / Compton Greaves/Air Fresh.
59Supply and fixingcopper stainer/filter suitable for window type 1.5/2.0 TR capacity AC of existing specification and make including taking out the unserviceable one complete all as directed.
60Supply and fixing electroniccircuit plate (PCB) for Split/Window A/C1.5 TR/2 TR capacity including taking down unserviceable one complete all as directed. Make- LG/Carrier/Samsung.
61Taking out the unserviceable sealed compressor unit from water cooler of 40/80ltrs cacacity and providing the new one of same specifications and make( Sealed compressor unit shall be purchased from company and should be sealed packing) duly tested and checking the complete system for leak proof and charging with appropriate quantity of refrigerant gas R-134 A and testing for smooth functioning complete all as directed.
62Material & labourfor detection and rectification of leakage in gas line by necessary brazing /solderingin water cooler of any capacity ,any type and any make and ensuring the system leak proofand replacement of required spare parts Includingcharging of refrigerant R-134 A in appropriate quantityin the system and testing for smooth functioning of W/C complete all as directed.
63Supply and fixing running capacitor 25/30 mfd ± 5%,400 voltfor Water Cooler having capacity 40/80/150 ltr iincluding taking down unserviceable one complete all as directed.Make : Usha/voltas/Asian
64Supply and fixing over load relay for water cooler having capacity 40/80/150 ltr including taking down unserviceable one complete all as directed. Make : Usha/voltas/Asian
65Supply and fixing float valve 15mm dia non-metallic for water cooler having capacity 40/80/150 ltr including taking down unserviceable one complete all as directed. Make : prayag /shakti
66Supply and fixing PVC connection of size 15mm dia for water cooler having capacity 40/80 /150 ltrs ncluding taking down unserviceable one complete all as directed. Make : prayag /shakti
67Supply and fixing PVC waste pipe of size25 mm dia for Water Cooler having capacity 40/80 and 150 ltrs including taking down unserviceable one complete all as directed.Make : prayag /shakti
68Material and labour for detection and rectification of leakage in gas line of refrigerator300/310Ltr capacityof any model andmakeby necessary brazing and ensuring the complete systems leak proof including chargingwith appropriate quantity of refrigerant gas R-134 Aincluding testing for smooth functioningand replacement of required spare parts complete all as specified and directed. Note:Spare parts like filter, capillary tube, cooling coiled, condensing coil if required will be measured and paid separately
69Material and labour for replacement of relay, suitable for 300/310 Ltr refrigerator of any make/modelincluding taking down unserviceable one complete all as directed.Make: Sri-ram/Usha /Renutrol /Indofos)
70Supply and fixing sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthedstranded copper conductor cable 4.0 sqmmas current carrying conductor and one run of 4.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and wall thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directedincluding taking down unserviceable one Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
71S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthedstranded copper conductor cable 6.0 sqmmas current carrying conductor and one run of 6.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and wall thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 4 sqmm all as specified and directedincluding taking down old one Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
72Supply and fixing MCB’s single pole 6 Amp to 30 Amp, 240 Volts,repurting capacity 10 K A complete all as specified and directed. Make:Sheineder/Legrand /L& /C&S
73Supply and fixing MCB’s single pole and neutal 32 Amp to 40 Amp, 240 Volts,repurting capacity 10 K A complete all as specified and directed. Make:Sheineder/Legrand /L&T/C&S
74Supplyi and fixing sheet metalenclosure with socket plug top and MCBs single pole with a two pin and earth plug andsocket complete with one singlle pole MCB of"C" series of capacity 16-32 Ampincluding taking out the unserviceable one all as specified and directed Make - Legrand / C&S/ Havells/L&Tr
75Supply and fixing non return valves cast copper alloy ISI marked 15 mm diaincluding taking out the unserviceable one complete all as specified and directed.Make : Theta/DassPass/Racold
76Supply and fixing pressure release valve of brass, inner threaded 15 mm diaincluding taking out the unserviceable one complete all as directed.Make : Theta/Dass Pass/Racold
77Supply and fixing pressure release valve of brass outer threaded of 15 mm dia including taking out the unserviceable one complete all as directed.Make : Theta/Dass Pass/Racold
78Supply and fixing heavy duty steel bedded PVC polythene connection with 15mm dia 450mm long with CP brass nuts and leads PVC washer 02 Nos on each endsfor Hot waterincluding taking out the old one complete all as specified and directed make : Prayag or Poly tuff or equivalent.
79Supply and fixing heavy duty steel bedded PVC polythene connection 15mm dia 450mm long with CP brass nuts and PVC washer completefor cold water completeincluding taking out the unserviceable one all as specified and directed make : Prayag/ Poly tuff.
80Supply and fixing metal clad Industrial plug top ISI marked 2 pin with earth 240 Voltsincluding taking down unserviceable one complete as specified and directed. Make – Havels/ Legrand /L&T
81Supply and fixing metal clad Industrial socketISI marked with earth 240 Voltsincluding taking down unserviceable one complete as specified and directed. Make – Havels/ Legrand/L&T
82Supply and fixing PVC insulated copper cable 3 core 40/ 0.0076,AC 1100/660 volt including taking down unserviceable one complete as specified and directed. Make-RR cables/ Havells / Plaza)
83Supply and fixing metallicc fastener screw 75mm long 6mm dia with bolt for hanging Geyser complete all as specified and directed.
84Material and labour for prepration of external surface storage type geyser of capacity 25 to 50 litres by comlete removal existing damage paint and applying two coats of synthetic enameled paintover a coat of red oxide primer including writing MES No with black paint complete all as specified and directed.
85Material and labour for Galvanised tubing 15 mm bore medium gradeISI Marked fixed to walls and ceiling or laid in trenches/floorwith all fitting andaccessoriescomplete all as specified and directed.Make : Jindal/Tata/Bansal/Nidhi
86Supply and fixing cast copper alloy multifunction safety valve 15 mm dia ISI marked including taking out the unserviceable one ne complete all as specified and directed,Make : Theta/Dass Pass/Racold
87S&Ffor socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked including taking down old one. Make: ANCHOR/PLAZA/KINJAL
88S&Fswitch sockst combination 2 in 1, 6 pin 5 & 15 Amps flush type universal , 240 Voltsincluding taking down the unserviceable one ne complete all as specified and directeddMake: ANCHOR/KINJAL
89Supply and replacement of Rubber Gasket flange as per site requirement for 25/50 ltr geyserincluding taking out the old one
90S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete of 15 mm dia including taking out old UNSV all as specified and as directed.(Make : Theta/Dass Pass/Racold)
91S&F Top plug15 amps 3 pin , 240 Voltsincluding taking out the old one complete all as specified and directed . Make:ANCHOR/HAVELLS/PLAZA
92S & F MCB TPN 63 Amp 415 V 16 KA ,connectionwith copper lugs complete all as directed. Make: LEGRAND Cat Pat No. 408702 or equivelent make and model of L&T/SHEINEDER