}

Supply Of U54, Ac Voltage Transducer, Make:Southern Transducers, Model:8061, Single Output, Nominal Input Voltage:110V, Output 4-20Ma, Aux.Power Supply:240V +/- 20%, 1-Ph, 50Hz, Ac, Accuracy +/- 0.5%, Insulation Level: 2Kv Rms For 1 Min, Maximum Continu-Tamil Nadu

Neyveli Lignite Corporation Limited has published Supply Of U54, Ac Voltage Transducer, Make:Southern Transducers, Model:8061, Single Output, Nominal Input Voltage:110V, Output 4-20Ma, Aux.Power Supply:240V +/- 20%, 1-Ph, 50Hz, Ac, Accuracy +/- 0.5%, Insulation Level: 2Kv Rms For 1 Min, Maximum Continu. Submission Date for this Tender is 21-08-2021. Lead Supply Tenders in Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

28670215
Supply Of U54, Ac Voltage Transducer, Make:Southern Transducers, Model:8061, Single Output, Nominal Input Voltage:110V, Output 4-20Ma, Aux.Power Supply:240V +/- 20%, 1-Ph, 50Hz, Ac, Accuracy +/- 0.5%, Insulation Level: 2Kv Rms For 1 Min, Maximum Continu
Open Tender
Indian
Tamil Nadu
21-08-2021

Tender Details

Supply Of U54, Ac Voltage Transducer, Make:Southern Transducers, Model:8061, Single Output, Nominal Input Voltage:110V, Output 4-20Ma, Aux.Power Supply:240V +/- 20%, 1-Ph, 50Hz, Ac, Accuracy +/- 0.5%, Insulation Level: 2Kv Rms For 1 Min, Maximum Continuous Input Voltage: 137.5V, Short Time Input Voltage:165V For 10 Sec. Transducer To Be Calibrated To 14.67Ma For 110V Ac Input Voltage, Mounting: Projection Type. U55, Ac Current Transducer, Make:Southern Transducers, Model:8066, Single Output, Nominal Input:1A Ac, Output 4-20Ma, Aux.Power Supply:240V +/- 20%, 1-Ph, 50Hz, Ac, Accuracy +/- 0.5%, Insulation Level: 2Kv Rms For 1 Min, Maximum Continuous Input: 2A Ac, Short Time Input: 15A For 10 Sec. Transducer To Be Calibrated To 12Ma For 1A Ac Input Current, Mounting: Projection Type. DC Voltage Transducer with Dual Output, Make:Southern Transducers, Model: 8020, Input: 0 to 60 milli Volts DC, Output 4-20mA, Isolated Aux.Power Supply:240V AC, Test Voltage: 4KV, 50Hz for 1 minute, Accuracy:0.5% or better. Note: Application is measurement of field current through a shunt of 0-60 milli volts DC. DC Voltage Transducer, Make:Southern Transducers, Model: 8020, Input: 0 to 300V DC, Dual Output 4-20mA, Isolated Aux.Power Supply:240V AC, Test Voltage: 4KV, 50Hz for 1 minute, Accuracy:0.5% or better DC Voltage Transducer(Isolated), Make:Southern Transducers, Model:8020, Range: -15V -0- +15V, Calibration Input: (-) 15V -0- (+) 15V, Output 4-20mA(Dual Output), Aux.Power Supply:240V AC, Insulation Test Voltage: 2KV RMS for 1 Min,Output shall be galvonically isolated. Type No.of Southern:8020/221/009/17/0/0/0 Transducer Reactive Power, Make:Southern Transducers, Model:8085, 3 Phase 3 Wire Unbalanced, Rated Input Voltage:110V AC, Rated Input Current:1A, Output 4-12mA-20mA equivalent to 190.52 MVAR Lead ... 0...190.52MVAR Lag, Aux.Power Supply:240V +/- 20%, 1-Ph, 50Hz, AC, Frequency:50Hz, Accuracy +/- 0.2%, Maximum Continuous Input Voltage (Overload Capacity): 137.5V, Short Time Input Voltage:165V for 10 sec. Maximum Continuous Input Current (Overload Capacity): 2A. Short Time Input Current:15A for 10 sec. Transducer Output is to be calibrated to 14.67mA for 110V AC Input Voltage, Mounting: Projection Type. Transducer Active Power, Make:Southern Transducers, Model:8075, 3 Phase 3 Wire Unbalanced, Rated Input Voltage:110V AC, Rated Input Current:1A, Output 4-20mA, Aux.Power Supply:240V +/- 20%, 1-Ph, 50Hz, AC, Frequency:50Hz, Accuracy +/- 0.2%, No Damping, Maximum Continuous Input Voltage (Overload Capacity): 137.5V, Short Time Input Voltage:165V for 10 sec. Maximum Continuous Input Current (Overload Capacity): 2A. Short Time Input Current:15A for 10 sec. Transducer Output is to be calibrated to 14.67mA for 110V AC Input Voltage, Mounting: Projection Type. PF Transducer Unipolar, Make:Southern Transducers, Model:8095, 3 Phase Single Output, Rated Input Voltage:110V AC, Rated Input Current:1A, PF Range:0.5 lead - 1 - 0.5 lag, Output 4-12mA-20mA, Aux.Power Supply:240V +/- 20%, 1-Ph, 50Hz, AC, Frequency:50Hz, Accuracy +/- 0.5%, Insulation Level: 2KV RMS for 1 Min, Maximum Continuous Input Voltage (Overload Capacity): 137.5V, Short Time Input Voltage:165V for 10 sec. Maximum Continuous Input Current (Overload Capacity): 2A. Short Time Input Current:15A for 10 sec. Transducer Output is to be calibrated to 14.67mA for 110V AC Input Voltage, Mounting: Projection Type.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail