Construction Of Awc At Pc Kumar House Under Moulani Gp Within Mal Development Block For The Year 2020-21, Awc No -57, Fund - Ridf-Xxvi, Aap Sl -351., MOULANI GP-West Bengal

Zilla Parishad-ZP has published Construction Of Awc At Pc Kumar House Under Moulani Gp Within Mal Development Block For The Year 2020-21, Awc No -57, Fund - Ridf-Xxvi, Aap Sl -351.. Submission Date for this Tender is 06-08-2021. Building Work Tenders in MOULANI GP West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

28662574
Construction Of Awc At Pc Kumar House Under Moulani Gp Within Mal Development Block For The Year 2020-21, Awc No -57, Fund - Ridf-Xxvi, Aap Sl -351.
Open Tender
Indian
West Bengal
MOULANI GP
06-08-2021

Tender Details

Construction Of Awc At Pc Kumar House Under Moulani Gp Within Mal Development Block For The Year 2020-21, Awc No -57, Fund - Ridf-Xxvi, Aap Sl -351.

Key Value

Document Fees
Refer document
EMD
INR 21129.0 /-
Tender Value
INR 10.56 Lakhs /-

BOQ Items

Name of Work : CONSTRUCTION OF AWC AT PC KUMAR HOUSE UNDER MOULANI GP WITHIN MAL DEVELOPMENT BLOCK FOR THE YEAR 2020-21, AWC NO -57, FUND - RIDF-XXVI, AAP SL-351.
Sl. No. Item Description
1(Item No.- 2(a); Page No.- 1 of PWD Bldg. Schedule) Earth work in excavation in foundation trenches in all sorts of soil (including mixed soil but excluding late rite and sand stone) including removing spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling dressing and ramming the bottom, bailing out water as required complete.
2(Item No.-10(a); Page No.- 5 of PWD Bldg. Schedule) Pre-Constructional Anti-termite measures: (a) Anti termite treatment to bottom surface ( in case of masonry foundation and basements) and the sides (upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 6.2.1. of code IS- 6313 (part -II) 1981. (Mode of measurment will be the plan area of foundation treated.)
3(Item No.-1; Page No.- 14 of PWD Bldg. Schedule)(3rd Corrigenda) Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
4(Item No.- 22(II/a); Page No.- 35 of PWD Bldg. Schedule)(3rd Corrigenda) (II) Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety, In ground floor (a) 1:3:6 proportion
5(Item No.- 8(a); Page No.- 15 of PWD Bldg. Schedule)(3rd Corrigenda) Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
6(Item No.- 3(a); Page No.- 1 of PWD Bldg. Schedule) Earth work in filling in foundation trenches or plinth with earth. in layer not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (payment to be on basis of measurement of finished quantity of work.) (a) with earth obtainedfrom excavation of foundation
7(Item No.-4(A); Page No.- 2 of PWD Bldg. Schedule) (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
8(Item No.-10(ii); Page No.- 26 of PWD Bldg. Schedule)(3rd Corrigenda) Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (ii ) River Bazree
9(Item No.-8(b); Page No.- 15 of PWD Bldg. Schedule)(3rd Corrigenda) Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor
10(Item No.-16; Page No.- 16 of PWD Bldg. Schedule)(3rd Corrigendam) 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
11(Item No.-36; Page No.- 42 of PWD Bldg. Schedule) Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation
12(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
13(Item No.- 40; Page No.- 44 of PWD Bldg. Schedule)(10th Corrigendam) Reinforcement for Reinforced Concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. Including supplies of rods , initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m. (i) Tor Steel/Mild SteelIn Ground Floor II. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL
14(Item No.- 1; Page No.- 189of PWD Bldg. Schedule)(3rd Corrigendam) Plaster (to wall, floor, celling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar, (b) 20 mm thick plaster (Internal Wall)
15(ii) With 1:4 cement mortar, (b) 15 mm thick plaster (External Wall)
16(ii) With 1:4 cement mortar, (c) 10 mm thick plaster (External Wall)
17(Item No.- 1; Page No.- 192of PWD Bldg. Schedule) Labour for Chipping of concrete surface before taking up Plastering work.
18(Item No.- 6; Page No.- 48of PWD Bldg. Schedule)(3rd Corrigendam) Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. (ii) 25 mm. thick
19(Item No.- 8; Page No.- 166 of PWD Bldg. Schedule) Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
20(Item No.- 1; Page No.- 114 of PWD Bldg. Schedule) Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (d) Sal : Local.
21(Item No.- 1; Page No.- 117 of PWD Bldg. Schedule) Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) (iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.
22(Item No.- 5; Page No.- 116 of PWD Bldg. Schedule) Supplying, Fitting & Fixing Factory made prelaminated P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm Prelaminated PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15 mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer?s specification and direction of Engineer-in-Charge.
23(Item No.- 16; Page No.- 126 of PWD Bldg. Schedule) Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge.
24(Item No.- 13; Page No.- 104 of PWD Bldg. Schedule)(3rd Corrigenda) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
25(Item No.- 4; Page No.- 140 of PWD Bldg. Schedule) Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 250mm Length
26(Item No.- 5; Page No.- 140 of PWD Bldg. Schedule) Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. viii) 100mm. X 75mm. X 3.50mm.
27(Item No.- 26; Page No.- 144 of PWD Bldg. Schedule) Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (vi) 200mm long x 10mm dia. bolt.
28(iv) 150mm long x 10mm dia. bolt.
29(Item No.- 28; Page No.- 145 of PWD Bldg. Schedule) Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (i) 250mm x 16mm dia bolt.
30(Item No.- 30; Page No.- 145 of PWD Bldg. Schedule) Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (vi) 150 mm grip x 10 mm dia rod.
31(Item No.- 30; Page No.- 145 of PWD Bldg. Schedule) Renewing 125mm long wooden buffer block i) With Sal : Siliguri.
32(Item No.- 21; Page No.- 212 of PWD Bldg. Schedule) Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.
33B) UPVC Fittings: c) Bend 87.5 degree (ii) 110 mm. Dia.
34B) UPVC Fittings: d) Shoe (ii) 110 mm. Dia.
35(Item No.- 1; Page No.- 200 of PWD Bldg. Schedule) (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
36a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
37(Item No.- 2; Page No.- 200 of PWD Bldg. Schedule) (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
38(b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
39(Item No.- 1; Page No.- 194 of PWD Bldg. Schedule) White washing including cleaning and smoothening surface thoroughly. All floors : (c) Three coats (on new works only).
40(Item No.- 15; Page No.- 197 of PWD Bldg. Schedule) Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer"s specification. In Ground floor: (iii) Two coats.
41(Item No.- 35; Page No.- 64 of PWD Bldg. Schedule)(3rd Corrigenda) Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white
42(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white
43(Item No.- 46; Page No.- 74 of PWD Bldg. Schedule)(3rd Corrigenda) Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety (i) 25 mm. thick
44P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 88 Item No. 3 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. (i) For 10 users ii) With Bazree (N.B Varity) (JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL) (N.B. Variety)
45P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 89 Item No. 4 Page No. B-(iv) Item -4 /Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. ii) With Bazree (N.B Varity) (JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL)
46P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 87 Item No. 1 Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. ii) With Bazree (N.B Varity) (JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL)
47P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 37 Item No. 6(a) Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (a) 500 litre capacity
48P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 37 Item No. 10 Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity a) Upto 1st story from G.L.
49P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 38 Item No. 13 Labour for punching hole in plastic water storage tank upto 50 mm dia.
50P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 6 Item No. 7 Supplying, fitting and fixing bib cock or stop cock. F (ii) Polythene Bib Cock / Stop Cock with plastic inlet (EMCO / ATLAS or equivalent) 15 mm
51P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 12 Item No. 19(I) Supplying, fitting and fixing PVC pipes of approved make of (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket,reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories,specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes (Dia)15mm
52(Dia)25mm
53(Dia)32mm
54P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 79 Item No. 4 Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding "P" or "S" trap (excluding cost of concrete for fixing) .(ii) 530 mm X 410 mm
55(Item No.- 24; Page No.- 74 of PWD Sanitary & Plumbing Schedule) Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials.(A) Above ground (i) 75 mm dia.
56P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 65 Item No. 14 Supplying,fitting and fixing cast iron "P" or "S" trap conformimg to I.S. 3989 / 1970 and 1729 / 1964 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately).(A) "P" Trap (i) 100 mm
57P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 53 Item No. 1 Supplying fitting fixing check valve ( Vertical) G. M. tested to 21 kg / sqm. (V) 40 mm
58P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 42 Item No. 6 Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (i) 530 mm X 430 mm x 180 mm
59P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 41 Item No. 1 Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets. (i) 450 mm X 300 mm size
60P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 5 Item No. 5 Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).(i) 40 mm dia
61P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 49 Item No. 1(a/i) Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (a) For depth upto 150 metre. (i) 40 mm dia. boring etc.
62P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 102 Item No. 1 Supply of G. I. pipes of TATA make including necessary sockets (e) 40 mm dia. (ii) Medium quality
63P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 12 Item No. 19(I) Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes (Dia) 40 mm
64P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 52 Item No. 6 Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (i) 40 mm dia.
65P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 53 Item No. 10 Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. (i) 40 mm
66P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 53 Item No. 9 Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. (i) 40 mm dia.
67P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 55 Item No. 23 Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
68P.W.D .rates of schedule (Sanitary & Plumbing) w.e.f. 1.11.2017 vide page no. 54 Item No. 14 Supplying, fitting and fixing popular Maya pump no-6 or similar. (i) For 40 mm dia. tube well
69(Item No.- 8(a); Page No.-15 of PWD Bldg. Schedule)(3rd Corrigenda) Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
70(Item No.-1; Page No.- 14 of PWD Bldg. Schedule)(3rd Corrigenda) Single Brick Flat Soling of picked jhama bricks including ramming and dressing bedto proper level and filling joints with local sand
71(Item No.-22 ( ii ); Page No.- 34 ofPWD Bldg. Schedule)(3rd Corrigenda) Cement concrete with 30 mm dn shingles(excluding shuttering) In ground floor(B) With N.B. Variety stone metal. (a) 1:3:6 proportion
72(Item No.- 6; Page No.-48 of PWD Bldg. Schedule)(3rd Corrigenda) Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labourIn ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (i) 25 mm. thick. In Ground Floor
73Supply, fitting & fixing Buster Pump / 0.50 HP Centrifugal pump for up-lifting water from hand tube well to over head storage tank
74Add:- GST @ 12%
75Add:- Cess @ 1%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail