Construction Of Satpediya Talab To Ghahar Musara Indaraha Approach Road, Rewa-Madhya Pradesh

Public Works Department-PWD has published Construction Of Satpediya Talab To Ghahar Musara Indaraha Approach Road. Submission Date for this Tender is 05-08-2021. Road Work Tenders in Rewa Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28604283
Construction Of Satpediya Talab To Ghahar Musara Indaraha Approach Road
Open Tender
Indian
Madhya Pradesh
Rewa
05-08-2021

Tender Details

Construction Of Satpediya Talab To Ghahar Musara Indaraha Approach Road

Key Value

Document Fees
INR 15000 /-
EMD
INR 311960.0 /-
Tender Value
INR 3.11 Crore /-

BOQ Items

Name of Work:CONSTRUCTION OF SATPEDIYA TALAB TO GHAHAR MUSARA INDARAHA APPROACH ROAD
Sl. No. Item Description
1Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.
2Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately
3Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead up to 1000m as per relevant clauses of section-300 of specification.
4Construction of embankment with approved materials CBR>7 deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-1, 300-2 and as per relevant clauses of section-300.
5Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300.
6Construction of unlined surface drains of average cross sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions to the requirement of clause 301 and 309. Excavated material to be used in embankment within a lead of 50 metres as per relevent clauses of section-300
7Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98- 1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings
8Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications. For 37.5 mm maximum size
9Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13and as per clause of section 406 of specifications.
10Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.75 kg/sqm using mechanical means as per clause 502 of specifications.
11Providing and applying tack coat with catonic bitumen emulsion (RS-1) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications. 0.30 kg per sqm (dry & hungry bituminous surfaces /granular surfaces treated with primer)
12Open - Graded Premix Surfacing Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades all complete as per clause 510 of specification Case - I: Mechanical method using Penetration grade Bitumen and HMP of appropriate capacity not less than 75 tonnes/hour.
13Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats all complete as per clause 511 of specification. Case - II : Type B (Providing and laying of premix sand seal coat with HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping (aggregate shall pass 2.36mm seal and retained to 180 micron sieve) and penetration bitumen of suitable grade all complete as per clause 511 of specification.
14Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100 kN static weight to meet requirement as per relevant clause of 400
15Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc 5th kilometre stone (precast)
16Ordinary Kilometer stone (Precast)
17Hectometer stone (Precast)
18Providing and fixing guard stones 220x220x1000mm made of hammer dressed stones and fixed 400mm into the ground in moorum and broken aggregates block of size 500x500x500 mm and given two coats of paints with white and black bands i/c excavation etc. complete. On curves or at any other places ad directed by engineer incharge
19Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2010 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide clause 801.3.3 fixed over Aluminium composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminium with overall thickness of 4mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to Table 800-1 of specification and High Intensity Micro Prismatck Grade Sheeting shall conform to Table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to ground by means of properly designed foundation with M15 grade concrete 450x450x600mm The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. 90cm equilateral triangle
2060cm equilateral triangle
2160cm circular
2280x60mm rectangular
2360x45cm rectangular
2460x60cm squre
2590cm high octagon
26with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retroreflectorised sign asper IRC:67 made of high intensity Micro- Prismatic Grade Sheeting (Type XI) vide clause 801.3.3 fixed over Aluminium composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminium with overall thickness of 4mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to Table 800-1 of specification and High Intensity Micro Prismatck Grade Sheeting shall conform to Table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on composite sign post of size 75mmx33.55mmx34.99 mm (5mm thick) made of Aluminium composite material in accordance to IRC 67-2010 fixed to ground by means of properly designed foundation with M15 grade concrete 450x450x600mm. The ACM sheet shall be fixed to the post with minimum two number breakaway bolts.
27Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811.
28Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. as per relevant clauses of section 300 & 2100 in upto 3 m depth
29Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.
30Provdiing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with . PCC Grade M15
31Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 in RCC Grade M20
32Supplying, fitting and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications and as per relevant clause of section 1600.
33Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600.
34PCC M-15 in Foundation Plain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409.
35Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900.
36Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.
37Laying Reinforced Cement Concrete Pipe NP 4 /prestrssed concrete pipe on first class bedding in double row. Providing and Laying Reinforced cement concrete pipe NP4 /prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.
38Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification
39Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications PCC Grade M-20
40Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications RCC Grade M-25
41Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 in RCC Grade M25
42Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications..
43Supplying, fitting and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications as per relevant clauses of section 1600
44Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix 6 of IRC-78.
45Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
46Providing and fixing in position bituminous paper bearing for slabs as per approved drawing and confirming to IS:1398.
47Providing weep holes in Brickasonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC/PVC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce.omplete as per drawing and Technical specifications
48Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications and as per relevant clauses of sections 1500, 1600, 1700 and clause 2703 of specifications (as per MoST specification drawing SD/201 or SD/304)
Disclaimer :