}

Hst / 1P-442 / 95 / 2019 / 77 / Group Vii E Tender For Procurement Of Different Types Of Pacemakers For The Two Years From The Date Of Award Of Contract ( Aoc ) , Cardiac Resynchronisation Therapy ( Crt-P ) Biventricular Pacemaker, Biventricular Pa, KOLKATA-West Bengal

Health And Family Welfare Department has published Hst / 1P-442 / 95 / 2019 / 77 / Group Vii E Tender For Procurement Of Different Types Of Pacemakers For The Two Years From The Date Of Award Of Contract ( Aoc ) , Cardiac Resynchronisation Therapy ( Crt-P ) Biventricular Pacemaker, Biventricular Pa. Submission Date for this Tender is 25-10-2021. Industrial Process Machinery and Equipments Tenders in KOLKATA West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

28575121
Hst / 1P-442 / 95 / 2019 / 77 / Group Vii E Tender For Procurement Of Different Types Of Pacemakers For The Two Years From The Date Of Award Of Contract ( Aoc ) , Cardiac Resynchronisation Therapy ( Crt-P ) Biventricular Pacemaker, Biventricular Pa
Open Tender
Indian
West Bengal
KOLKATA
25-10-2021

Tender Details

Hst / 1P-442 / 95 / 2019 / 77 / Group Vii E Tender For Procurement Of Different Types Of Pacemakers For The Two Years From The Date Of Award Of Contract ( Aoc ) , Cardiac Resynchronisation Therapy ( Crt-P ) Biventricular Pacemaker, Biventricular Pacemaker With Atrial, Rv, Coronary Sinus ( Lv ) Leads And All Accessories Required During Implantation Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less. The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration. Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. Must Have Ra, Rv And Lv Capture Management. Must Have Remote Patient Management Capability. , Pulse Generator [ For Cardiac Resynchronisation Therapy ( Crt-P ) Biventricular Pacemaker , Biventricular Pacemaker With Atrial, Rv, Coronary Sinus ( Lv ) Leads And All Accessories Required During Implantation Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less. The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration. Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. Must Have Ra, Rv And Lv Capture Management. Must Have Remote Patient Management Capability. ] , Accessory [ For Cardiac Resynchronisation Therapy ( Crt-P ) Biventricular Pacemaker , Biventricular Pacemaker With Atrial, Rv, Coronary Sinus ( Lv ) Leads And All Accessories Required During Implantation Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less. The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration. Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. Must Have Ra, Rv And Lv Capture Management. Must Have Remote Patient Management Capability. ] , Pli [ For Cardiac Resynchronisation Therapy ( Crt-P ) Biventricular Pacemaker, Biventricular Pacemaker With Atrial, Rv, Coronary Sinus ( Lv ) Leads And All Accessories Required During Implantation Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less. The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration. Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. Must Have Ra, Rv And Lv Capture Management. Must Have Remote Patient Management Capability. ] , Lead [ For Cardiac Resynchronisation Therapy ( Crt-P ) Biventricular Pacemaker, Biventricular Pacemaker With Atrial, Rv, Coronary Sinus ( Lv ) Leads And All Accessories Required During Implantation Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less. The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration. Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. Must Have Ra, Rv And Lv Capture Management. Must Have Remote Patient Management Capability. ] , Slitter [ For Cardiac Resynchronisation Therapy ( Crt-P ) Biventricular Pacemaker, Biventricular Pacemaker With Atrial, Rv, Coronary Sinus ( Lv ) Leads And All Accessories Required During Implantation Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less. The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration. Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. Must Have Ra, Rv And Lv Capture Management. Must Have Remote Patient Management Capability. ] , Lead [ For Cardiac Resynchronisation Therapy ( Crt-P ) Biventricularpacemaker, Biventricular Pacemaker With Atrial, Rv, Coronary Sinus ( Lv ) Leads And All Accessories Required During Implantation Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less. The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration. Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. Must Have Ra, Rv And Lv Capture Management. Must Have Remote Patient Management Capability. ] , Lead [ For Cardiac Resynchronisation Therapy ( Crt-P ) Biventricular Pacemaker, Biventricular Pacemaker With Atrial, Rv, Coronary Sinus ( Lv ) Leads And All Accessories Required During Implantation Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less. The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration. Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. Must Have Ra, Rv And Lv Capture Management. Must Have Remote Patient Management Capability. ]

Key Value

Document Fees
Refer document
EMD
INR 200000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail