Repair And Cleaning To Sewage Line, Manholes, Septic Tanks And Repair To Area Drainage, Hardstanding, Interlocking Tiles, Boundary Wall, Fencing At Af Station Jamnagar No.1 Repair And Cleaning To Sewage Line, Manholes, Septic Tanks And Rep, JAMNAGAR-Gujarat

Military Engineer Services-MES has published Repair And Cleaning To Sewage Line, Manholes, Septic Tanks And Repair To Area Drainage, Hardstanding, Interlocking Tiles, Boundary Wall, Fencing At Af Station Jamnagar No.1 Repair And Cleaning To Sewage Line, Manholes, Septic Tanks And Rep. Submission Date for this Tender is 10-08-2021. Paver Blocking Tenders in JAMNAGAR Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

28543565
Corrigendum : Repair And Cleaning To Sewage Line, Manholes, Septic Tanks And Repair To Area Drainage, Hardstanding, Interlocking Tiles, Boundary Wall, Fencing At Af Station Jamnagar No.1 Repair And Cleaning To Sewage Line, Manholes, Septic Tanks And Rep
Open Tender
Indian
Gujarat
JAMNAGAR
10-08-2021

Tender Details

Repair And Cleaning To Sewage Line, Manholes, Septic Tanks And Repair To Area Drainage, Hardstanding, Interlocking Tiles, Boundary Wall, Fencing At Af Station Jamnagar No.1 Repair And Cleaning To Sewage Line, Manholes, Septic Tanks And Repair To Area Drainage, Hardstanding, Interlocking Tiles, Boundary Wall, Fencing At Af Station Jamnagar No.1

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Jul-2021 Corrigendum No 01 Date 10-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 97000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR AND CLEANING TO SEWAGE LINE, MANHOLES, SEPTIC TANKS AND REPAIR TO AREA DRAINAGE, HARDSTANDING, INTERLOCKING TILES, BOUNDARY WALL, FENCING AT AF STATION JAMNAGAR
Sl. No. Item Description
1Demolition of concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal of debris to a distance exc 1.5 km but n.exc 2 km
2Demolition of brickwork or stone/ boulder masonry / PCC block masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
3Dismantling fencing wire mesh, any type
4Dismantling wrought iron or mild steel work of any description not otherwise provided for
5M&L for cement concrete Type C2 (1:3:6) (40mm graded aggregate) in foundations filling and mass concrete
6M&L for cement concrete Type C2 (1:3:6) (40mm graded aggregate) in surface channels and drains
7M&L for providing, cement concrete Type B1 1:2:4 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
8M&L for providing, cement concrete Type B1 (1:2:4) (20mm graded aggregate) in kerbs or haunchings, rounded or chamfered on edges
9M&L for pre-cast cement concrete block masonry 1:5:8 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete
10S&F rolled mild steel Fe 410-W (Gde-E-250) quality-B in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated)
11S&F in repairsgalvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with andprovision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
12S&F mild steel galvanised chain linkfencing of wire3.5mm dia, galvanisedclass 3 as in fencing mesh including staining and fixing to concrete or steel posts end/or to straining bolts including securing with and provision of galvanised iron tying with, galvanised iron stapples or steel pins, etccomplete all as and as directed by Engr-in-Charge
13Taking down of galvanised existing concertina coilof size 750 mmand re-fixing of same position with using GI hooks fixed in PCC proper line/alignmentetc complete all as specified and directed
14S&F in repairs galvanized concertina coil of 750mm dia made of 0.5mm thick, 19mm wide strip & 2.59 mm dia high tensile wire, 125 Nos of clips, having 56 Nos of circles and covering 8 to 10 running mtrand "S" clips per spiral using a central core of high tensile wire around which a tape of razor sharp barbs is machine crimped etc all as specified.
15Demolition of concrete (reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal of debris to a distance exc 1.5 km but n.exc 2 km
16M&L for providing precast cement concrete Type B1 1:2:4 (20mm graded aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces Set in cement mortar 1:6 Note:- reinforcement steel will be measured and paid seperately
17M&L for TMT bars 6 to 8 mm dia, cut to length, bent to shape required including bedding and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Eng-in-Charge.
18M&L for 75 mm thick cement concrete type D- 2, 1:4:8 (40mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc
19M&L for machine pressed precast concrete interlocking paver block of approved shape and size of 80mm thickness, with minimum compressive strength of 40N/sqm (M-40 ), withoutcorrection factor for chamfering, made in rubber moulds with 0.50mm thick scratch proof lacquer coating on top surface, with white cement and pigment laid over and including 20mm thick sand screed bed complete
20M&L for rubber moulded chequered cement concrete tile with grey cement and pigment (of approved tint) of size 300 mm x 300 mm x 25 mm thick over and including 15mm thick screed bed in CM 1:6, set jointed and pointed in neat cement slurry complete
21M&L for 75 mm thick cement concrete type B- 2, 1:2:4 (40mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc
22M&L for dry lean concrete (DLC) corresponding to strength equivalent to M-15 grade as per IS-456 with minimum cement content 240 Kg per Cum using crushed stone aggregate as in sub base all as specified and directed. Note :Actual quantity of cement shall as per design mix or 240 Kg / Cum which ever is more, no extra payment shall be made if cement quantity as per design mix arrives more than 240 Kg / Cum
23M&L for 10 mm thick dry river sand as in cushioning including punning down of sand in layer all as specified and directed by Engg-in-Charge. NOTE:- Punned thickness of sand will be measured and paid.
24M&L for polythene film black 150 micron confirming to IS - 2508 laid inover sand cushioning all as specified and as directed by Engr-in-Charge..
25M&L for PQC as in pavement / hard standing, not exceeding 200 mm thick offlexural strength 35 Kg / Sqcm with cement content 350 Kg / cum or as per design mix which ever is higher including necessary steel formwork complete all as specified and as directed by Engr-in-Charge. Notes :- (i)Construction joints, dummy (contraction joints) and expansion joints shall be measured and paid separately under respective items of this schedule. (ii)Deduction shall be made in computing concrete quantity for expansion joints. (iii)The actual requirement of cement shall be as per the design mix and the tests specified. However if quantity of cement from the mix design found more than 350 kg / Cum, them same shall be provided with no extra cost to the Govt. In case cement content found to be less than 350 kg / Cum as per mix design as specified shall be adjusted @ rate of Rs 7.05 (Rupees seven & paisa five only) per kg of cement. The quantity of cement 350 Kg / Cum mentioned is exclusive of any wastage and no wastage shall be taken into account for the purpose of above adjustment
26Supply only non circular synthetic fibers with circumcircle diameter 30-35 micron design for melting point 240-260 degree celcius and having specific gravity of 1.34 to 1.4
27Finishing surface of concrete roads pavement by floater, plate vibrator when the concrete is green all as specified and directed by Engr-in-Charge.
28M&L for Forming 12 mm thick expansion joint for 200 mm thick concrete slab filled with preformed bituminous filler board and top 30 mm primed and sealed with sealing compound grade "B"all as specified and as directed.
29M&L for Forming constructionjoints in concrete pavement, 30 mm deep x 10 mm wide, priming & filled with sealing compound Grade "B" all as specified and as directed.
30M&L for Forming contractionjoints (Dummy) in concrete pavement, 30 mm deep x 10 mm wide priming & filled with sealing compound Grade "B" all as specified and as directed.
31Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. including removal of debris to a distance exc 1.5 km but n.exc 2 km
32M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement
33M&L for preparation of new plastered surfaces of walls and applying 2 coats of weather proof exterior emulsion paint in camouflage pattern by diluting with water (as per manufacturer direction).A gap of 24 hours should be given between two coats, over a coat of primer on plastered surface. The surface should be allowed to cure completely for atleast four hours after applying one coat of exterior wall primer (X2) by thinning a litre of primer with onelitre of water complete all as specified and directed.
34M&L for preparation of old plastered wall surfaces including pilaster/cornices etc and applying one coat of acrylic emulsion (exterior weather coat) paint of any tint as approved all as specified and directed
35M&L for preparation of old decorated steel Surfaces of any description, over 10cm in width or girth,not otherwise described and applying one coat of synthetic enamel paint
36M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer
37Desludging & cleaning of manholes depth not exc 1.0m of any size & shape by removing all sludge/waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge/waste etc outside MOD land (complaint slip collect from complaint cell in daily)
38Desludging & cleaning of manholes depth exc 1 mtr and n.exc 2 mtr of any size & shape by removing all sludge/waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge/waste etc outside MOD land (complaint slip collect from complaint cell in daily)
39Cleaning & desludging of septic tanks of capacity 10 to 25users by pumping out sewage & sludge & disposing all waste including liquidin covered tanks outside MOD land and finally cleaning & washing with fresh water complete all as specified & directed by Eng-in-Charge.
40Cleaning & desludging of sockage wellof capacity 2.5m dia and 3m depth by pumping out sewage & sludge & disposing all waste including liquidin covered tanks outside MOD land and finally cleaning & washing with fresh water complete all as specified & directed by Eng-in-Charge.
41Cleaning of gully traps, WHB,Floor trap, nahani trapsetc any type of floor position by removing all sludge/waste etc including cleaning of connected pipe upto gully trap to remove blockage, and finally washing with clean water including disposing of all sludge/waste etc outside MOD land.
42Cleaning of blockage from WC/EWC/Urinal at any type of floor by removing all sludge/waste etc including cleaning of connected pipe upto first manhole to remove blockage, and finally washing with clean water including disposing of all sludge/waste etc outside MOD land.
43Cleaning of sewage lines 100/150/200 mm dia from manhole to manhole by manual/mechanical rodding, removing all sludge/waste and making the line functional incl disposing of all sludge/waste etc outside MOD land.
44Demolition and breaking up 150/200 mm dia (salt glazed ware, AC or Reinforced concrete) set in cement mortar, including PCC packing under haunching against the sides of bed and complete PCC of bed all complete all as specified & directed by Eng-in-Charge.
45Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil
46All as per item No 45 above but depth exc 1.5 m and n.exc 3.00 m
47Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exc 25 cm.
48Removing excavated material (soil) exc. 1.50 km but n exc. 5 km and depositing where directed
49S&F 150 mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars
50S&F 200 mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars
51M&Lfor PCC 1:4:8 type D2 (using 40mmgraded aggregate) in packing under and haunching against the sides of pipes 150mm dia bore after they are laid and tested
52M&Lfor PCC 1:4:8 type D2 (using 40mmgraded aggregate) in packing under and haunching against the sides of pipes 200mm dia bore after they are laid and tested
53M&L for 75 mm thick cement concrete type C- 2, 1:3:6 (40mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc
54S&F in repairs PVC (SWR) bend 110 mm bore any radius
55S&F in repairs PVC (SWR) bend 75 mm bore any radius
56S&F in repairs PVC(SWR) branch pieces 110 mm bore single (single Y) equal or unequal
57S&F in repairs PVC(SWR) vent cowl 110 mm bore
58M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement motar 1:4
59M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement including mixing only liquid water proofing compoundas per manufacturers" instructions Note:- WPC will be measured & Paid separately
60Supply only liquid water proofing compound
61M&L for 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement
62S&F in repairs PVC (SWR) 125 / 110 mm bore"P" trap
63S&F in repairs vitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts & P or S trap) and finishing with white cement
64S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding
65Cleaning of PCC drain not exceeding 1.5 metre deep by removing of deposited soft / loose soil and other foreign materials not exc 30 cm deep and average 15 cm deep and removal of excavated material to a distance exc 1 km but n.exc 2 km complete all as specified and directed by Engineer-in-charge Note:- width of bottom of drain multiplied by the length of drain cleaned shall be measured for payment.
66Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning of HDPE/PVC water tank of capacity upto & including 500 ltr by flushing out water, cleaning & removing of sludge, scale mud etc from wall & floor by rubbing with brushes, cleaning with caustic soda etc complete & finally washing with fresh water including writing date of cleaning with white synthetic enamel paint and after cleaning the tank,refixing of outlet and inlet of water pipe line complete all as specified & directed by Eng-in-Charge.
67All as per Item No 66 above but capacity of tank exc 500 ltr but not exc 1000 ltr
68S&F PVC (SWR) pipes 110 mm bore, single socketed in any length with rubber ring joints fixed to walls including taking down old pipe
69S&F PVC (SWR) pipes 75 mm bore, single socketed in any length with rubber ring joints fixed to walls including taking down old pipe
70Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required
71S&Fin repairs white vitreous china wash hand basin (Flat back) of size 580x450mm fixed on and including new brackets complete including 15mm size pillar tap, cast copper alloy, chromium plated with capstan head, screwed down high pressure, with or without lettered "Hot" or "Cold"with long screwed shank and fly nuts, screwed for iron pipe, 32mm size brass chromium plated waste coupling, 750mm long PVC waste pipe, PVC connection pipe, 15mm size and 450mm long with PTMT nuts and washer at both end etc complete all as specified and directed.
72S&F in repairs white vitreous china urinal, Half stall type, (excluding flushing cistern) with 32mm size brass CP waste coupling & discharge pipe providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and incl 60mm long brass scrwed , pointing around urinal back in cement, including cast copper alloy chromium plated urinal spreader complete all as specified and directed
73S&F in repairs 50mm dia high density polyethylene pipe (HDPE) of pressure rating 6kgf/sqcm fixed to complete to walls/ceiling /floorsetc complete all as specified and directed
74S&F in repairs plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device
75Supplying and laying of 20 mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including taking down old pipes.
76S&F in repairs gun-metal, globe or gate valves 15 mm bore dia of pipe, with iron wheel head, screwed both ends for iron pipe and fixed
77S&F in repairs gun-metal, globe or gate valves 20 mm bore dia of pipe, with iron wheel head, screwed both ends for iron pipe and fixed
78S&F in repairs stop valves 15 mm bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated with long shank and cup (concealed type)
79S&F in repairs 15mm size angular cock, cast copper alloy, CP fancy type with capstan head, screwed down, screwed both end for iron pipes complete
80S&F in repairs 15 mm size fancy type, chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
81S&F in repairs 15mm dia size PVC Bib tap fixed to iron pipes complete all as directed
82S&F in repairs Pillar taps 15 mm size , cast copper alloy,with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
83S&F in repairs 15 mm size swan neck pillar tap cast copper alloy, chromium plated, with capstan head, screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shank and fly nuts, screwed for iron pipe, complete
84S&F in repairs 15 mm size, brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed
85S&F in repairs brass CP, hand faucet with one meter long flexible pipe fixed to EWC complete all as specified and directed
86S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers
87Supply and fix in repair 500 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete.
88Supply and fix in repair 1000 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete.
89S&F in repair PVC cover for HDPE water tank of capacity 500 / 1000 litres including necessary fixture etc complete all as specified.
90S&F in repair waste coupling of 40 mm size brass chromium plated for glazed ware sink basins, etc with long screwed shanks and fly nuts flanges end bedded in red lead cement and other end fixed.
91S&F in repair waste coupling of 32mm size brass CP for glazed ware basins / urinal etc with long screwed shanks and fly nuts flanges end bedded in red lead cement and other end fixed.
92S&F in repair PVC waste water pipe for sink / basins / urinals of size 40 mm dia and 1 m long.
93S&F in repair PVC waste water pipe for sink / basins / urinals of size 32 mm dia and 1 m long.
94S&F in repair stainless steel grating round 150mm size with waste hole complete all as specified and directed
95S&F in repairs 15mm size PVC connection with brass nuts of length 450mm complete all as specified and directed
96S&F in repairs 15mm size PVC connection with brass nuts of length 600mm complete all as specified and directed
97S&F in repairs 10 litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including bracket and connections to pipes and fixing of chain and pull, or lever.
98S&F in repairs 15 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight -142gms)
99S&F in repairs 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight -210gms)
100S&F in repairs 25 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight -455gms)
101S&F in repairs stainless steelsingle towel rail of size 600 mm long
102Demolition of floor, hearth or wall tiling or stone slab laid , bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debris to a distance exc 1.5 km but n.exc 2 km complete
103M&L for Non - skid joint free coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including screed bed or bedding layer of cement mortar 1:6, 15 mm thick
104M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, over and including 10mm thick backing coat in cement mortar 1:4
105S&F brass chromium plated bottle trap with internal partition 32 mm size with 250 mm & 190 mm long wall connection pipes & wall flanges including fixing to wash basin, urinals etc. complete all as specified and directed.
106S&F in repairs shower arm casted 190 mm long light body round shape for wall mounted showers with flange including fixing complete all as specified. Make: Jaquar Cat Part No.SHA-477 or equivalent of make mentioned in Appendix "B"
107S&F in repairs shelf of PTMT fixed with and including Chromium plated brass screws and wooden / plastic cleats (Minimum weight 300gms)
108S&F in repairs urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)
109S&F in repairs toilet paper holder, brass, chromium plated fixed to walls with chromium plated (CP) brass screws
110Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
111S&F in repair health faucet with 1 meter long easy flex tube in chrome finish & wall hook, complete all as specified Make:- Jaquar-ALD-CHR-565 or equivalent of make mentioned in Appendix "B"
112S&F in repair Vitreous china wash down water closet pan (pedestal pattern) wall hung EWC size 575 mm x 360 mm x 360 mm including UF seat cover, hinges, accessories set and all fittings complete all as specified and directed. Make:- Jaquar-ARS-WHT-39951 or equivalent of make mentioned in Appendix "B"
113S&F in repair corner glass shelf including fixing arrangement complete all as specified and directed Make:- Jaquar-ACN-1173 or equivalent of make mentioned in Appendix "B
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy