Supply Of Supply, Installation & Commissioning Of Different Types Of Smps Based Ips.Block Diagram Of Ips Attached.Supply, Installation & Commissioning Of Different Types Of Smps Based Ips.Block Diagram Of Ips Attached.,Supply, Installation & Commissioni-Uttar Pradesh

East Central Railway-ECR has published Supply Of Supply, Installation & Commissioning Of Different Types Of Smps Based Ips.Block Diagram Of Ips Attached.Supply, Installation & Commissioning Of Different Types Of Smps Based Ips.Block Diagram Of Ips Attached.,Supply, Installation & Commissioni. Submission Date for this Tender is 23-08-2021. Chemical Supply Tenders in Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28537863
Supply Of Supply, Installation & Commissioning Of Different Types Of Smps Based Ips.Block Diagram Of Ips Attached.Supply, Installation & Commissioning Of Different Types Of Smps Based Ips.Block Diagram Of Ips Attached.,Supply, Installation & Commissioni
Open Tender
Indian
Uttar Pradesh
23-08-2021

Tender Details

Supply Of Supply, Installation & Commissioning Of Different Types Of Smps Based Ips.Block Diagram Of Ips Attached.Supply, Installation & Commissioning Of Different Types Of Smps Based Ips.Block Diagram Of Ips Attached.,Supply, Installation & Commissioning Of Smps Based Ips For Interlocked Lc Gate In Re/Non-ReArea Confirming To Rdso Specification No. Rdso/Spn/165/2012 (Ver.3.0) Or Latest Amdt. And Sketch No.Sdo/Ips/Lc/007 Along With 200 Ah Low Maint. Lead Acid Battery. Technical Specification: A. Specification No. :-Rdso/Spn/165/2012 (Ver 3.0) B. Applicable Sketch No. Sdo/Ips/Lc/007. C. Type Of Battery:200Ah Lmla OrVrla. D. Dc-Dc Converter For Ssi/Data Logger:-Not Required. E. Dc-Dc Converter For Axle Counter- NotRequired. F. Dc-Dc Converter For Block Working Not Required. G. Type Of External & Internal Relays;24 V, Q TypeRelays. H. Dc-Dc Converter [3-6V/0.1A] 04 Nos. [For Block Telephone Mt] I. Distance Between Ips Room ToAsm Panel [In Meter] : 50 Meter -100 Metres J. Distance Between Ips Rack & Battery [In Meter] :20-30 Meters.K. Whether Installation Is To Be Done By Oem-Yes. L. Supply Of Spares As Per List Given Below: Sn Sub SystemSpares Components Qty. (1 ) Smps: Charger Module Module (As Cold Standby) 01 Module. (2) Inverter ModuleModule (As Cold Standby) 01 Module. (3) Dc-Dc Converter Dc-Dc Converter For Relay Internal Relay External AndBlock Line Or As Required By The Purchaser. 01 Module Each. (4) Ferro-Resonant Automatic Voltage- Regulator(Avr) Ac Capacitor 01 Set. (5) Fuses All Type Of Fuses Used In Ips Sub-System 01 Set. (6) Transformer Modular(As Cold Standby) 02 Module. (7) Inverter/Smr Dc Fan 02 Nos. (8) Cells 2V Cells 05 Nos Note : Block Diagram(Ecr Sketch) Of Ips Attached.Sse/Sig/1/Mgs Uttar Pradesh 1.00 Numbers , Supply, Installation, Testing & Commissioning Of Smps Based Ips Confirming To RdsoSpecification No. Rdso/Spn/165/ 2012 Ver3.0 Or Latest Amdt.And Sketch No. Sdo/Ips/Pi- 6L/Re/004 For Ips UpTo 6 Lines Without Aftc Re Area Along With 200 Ah Low Maint. Lead Acid Battery. Technical Specification: A.Specification No. :- Rdso/Spn/165/2012 (Ver 3.0) B. Applicable Sketch No. Sdo/Ips/Pi-6L/Re/004 C. Type OfBattery:200Ah Lmla Or Vrla. D. Dc-Dc Converter For Ssi/Data Logger:-Yes, All Optional Items Are Required E.Dc-Dc Converter For Axle Counter-Yes, Required F. Dc-Dc Converter For Block Working :[12-40V, 1 Amp],Or [40-100V, 1 Amp], Or [24-32V, 5A] To Be Decided At The Time Of Loa G. Type Of External & Internal Relays;24 V, QType Relays. H. Dc-Dc Converter [3-6V/0.1A] 04 Nos. [For Block Telephone Mt] I. Distance Between Ips RoomTo Asm Panel [In Meter] ; 50-100 Meter J. Distance Between Ips Rack & Battery [In Meter] ; 20-30 Meter. K.Whether Installation Is To Be Done By Oem-Yes. L. Supply Of Spares Required As Per List Given Below: Sn SubSystem Spares Components Qty. (1) Smps: Charger Module Module (As Cold Standby) 01 Module. (2) InverterModule Module (As Cold Standby) 01 Module. (3) Dc-Dc Converter Dc-Dc Converter For Relay Internal RelayExternal And Block Line Or As Required By The Purchaser 01 Module Each. (4) Ferro-Resonant Automatic Voltage-Regulator (Avr) Ac Capacitor 01 Set. (5) Fuses All Type Of Fuses Used In Ips Sub-System 01 Set. (6)Transformer Modular (As Cold Standby) 02 Module. (7) Inverter/Smr Dc Fan 02 Nos. (8) Cells 2V Cells 05 Nos.Block Diagram (Ecr Sketch) Of Ips Attached.C.S.I./Store/Dhn Jharkhand 1.00 Numbers , Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No.Rdso/Spn/165/2012 (Ver.3.0) Or Latest Amdt. And Sketch No. Sdo/Ips/Pi-4L/Nre/ 001 For Ips Up To 4 LinesWithout Aftc Non-Re Area Along With 300 Ah Low Maint. Lead Acid Battery. Technical Specification: A.Specification No. :- Rdso/Spn/165/2012 (Ver 3.0) B. Applicable Sketch No. Sdo/Ips/Pi/4L/Nre/001 C. Type OfBattery:300Ah Lmla Or Vrla. D. Dc-Dc Converter For Ssi/Data Logger:-Yes , All Optional Items Are Required.E. Dc-Dc Converter For Axle Counter-Yes, Required F. Dc-Dc Converter For Block Working :[12-40V, 1 Amp],Or[40-100V, 1 Amp], Or [24- 32V, 5A] To Be Decided At The Time Of Loa. G. Type Of External & Internal Relays;24 V, QSeries Relays H. Dc-Dc Converter [03-6V/.1A] 04 Nos. For Block Telephone /Mt I. Distance Between Ips RoomTo Asm Panel [In Meter] ; 50-100 Meter J.Distance Between Ips Rack & Battery [In Meter] 20-30 Meter. K.Whether Installation Is To Be Done By Oem-Yes. L. Supply Of Spares Required As Per List Given Below: Sn SubSystem Spares Components Qty. (1) Smps: Charger Module Module (As Cold Standby) 01 Module. (2) InverterModule Module (As Cold Standby) 01 Module. (3) Dc-Dc Converter Dc-Dc Converter For Relay Internal RelayExternal And Block Line Or As Required By The Purchaser 01 Module Each. (4) Ferro-Resonant Automatic Voltage-Regulator (Avr)Ac Capacitor 01 Set. (5) Fuses All Type Of Fuses Used In Ips Sub-System 01 Set. (6 )TransformerModular (As Cold Standby) 02 Module. (7) Inverter/Smr Dc Fan 02 Nos. (8 ) Cells 2V Cells 05 Nos. BlockDiagram (Ecr Sketch) Of Ips Attached. , Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No.Rdso/Spn/165/ 2012 (Ver3.0) Or Latest Amdt. And Sketch No. Sdo/Ips/Pi- 4L/Re/002 For Ips Up To 4 LinesWithout Aftc Re Area Along With 200 Ah Low Maint. Lead Acid Battery. Technical Specification: A. SpecificationNo. :- Rdso/Spn/165/2012 (Ver 3.0) B. Applicable Sketch No. Sdo/Ips/Pi-4L/Re/002 C. Type OfBattery:200Ah Lmla Or Vrla D. Dc-Dc Converter For Ssi/Data Logger:-Yes, All Optional Items Are Required. E.Dc-Dc Converter For Axle Counter-Yes, Required F. Dc-Dc Converter For Block Working :[12-40V, 1 Amp],Or [40-100V, 1 Amp], Or [24-32V, 5A] To Be Decided At The Time Of Loa G. Type Of External & Internal Relays;24 V, QType Relays. H. Dc-Dc Converter [3-6V/0.1A] 04 Nos.[For Block Telephone /Mt] I. Distance Between Ips RoomTo Asm Panel [In Meter] ; 50-100 Meter J.Distance Between Ips Rack & Battery [In Meter] 20-30 Meter. K.Whether Installation Is To Be Done By Oem-Yes. L. Supply Of Spares Required As Per List Given Below: Sn SubSystem Spares Components Qty. (1) Smps: Charger Module Module (As Cold Standby) 01 Module (2) InverterModule Module (As Cold Standby) 01 Module (3) Dc-Dc Converter Dc-Dc Converter For Relay Internal RelayExternal And Block Line Or As Required By The Purchaser 01 Module Each. (4) Ferro-Resonant Automatic Voltage-Regulator (Avr) Ac Capacitor 01 Set (5) Fuses All Type Of Fuses Used In Ips Sub-System 01 Set (6) TransformerModular (As Cold Standby) 02 Module (7) Inverter/Smr Dc Fan 02 Nos. (8) Cells 2V Cells 05 Nos Block Diagram(Ecr Sketch) Of Ips Attached.Sse/S/W/Dhn Jharkhand 9.00 Numbers

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Sl. No. Item Description
1Supply, installation & Commissioning of different types of SMPS based IPS. Block diagram of IPS attached.
2Supply, installation & Commissioning of SMPS based IPS for Interlocked LC gate in RE/Non-RE Area Confirming to RDSO specification No. RDSO/SPN/165/2012 (Ver.3.0) or latest amdt. and Sketch No. SDO/IPS/LC/007 along with 200 AH Low Maint. Lead Acid Battery. Technical Specification: A. Specification No. :- RDSO/SPN/165/2012 (Ver 3.0) B. Applicable Sketch No. SDO/IPS/LC/007. C. Type of Battery:200AH LMLA or VRLA. D. DC-DC Converter for SSI/Data Logger:-Not required. E. DC-DC Converter for Axle Counter- Not required. F. DC-DC Converter for block working Not required. G. Type of external & Internal relays;24 V, Q Type Relays. H. DC-DC Converter [3-6V/0.1A] 04 Nos. [for Block Telephone MT] I. Distance between IPS Room to ASM Panel [in Meter] : 50 Meter -100 Metres J. Distance between IPS Rack & Battery [in meter] :20-30 Meters. K. Whether installation is to be done by OEM-Yes. L. Supply of spares as per list given below: SN Sub system Spares components Qty. (1 ) SMPS: Charger Module Module (as cold standby) 01 Module. (2) Inverter Module Module (as cold standby) 01 Module. (3) DC-DC Converter DC-DC Converter for relay internal relay external and block line or as required by the purchaser. 01 Module each. (4) Ferro-resonant Automatic Voltage- Regulator (AVR) AC Capacitor 01 set. (5) Fuses All type of fuses used in IPS sub-system 01 set. (6) Transformer Modular (as cold standby) 02 Module. (7) Inverter/SMR DC Fan 02 Nos. (8) Cells 2V Cells 05 Nos Note : Block diagram (ECR Sketch) of IPS attached. SSE/SIG/1/MGS Uttar Pradesh 1.00 Numbers
3 Supply, installation, Testing & Commissioning of SMPS based IPS Confirming to RDSO specification No. RDSO/SPN/165/ 2012 Ver3.0 or latest amdt.and Sketch No. SDO/IPS/PI- 6L/RE/004 for IPS up to 6 lines without AFTC RE area along with 200 AH Low Maint. Lead Acid Battery. Technical Specification: A. Specification No. :- RDSO/SPN/165/2012 (Ver 3.0) B. Applicable Sketch No. SDO/IPS/PI-6L/RE/004 C. Type of Battery:200AH LMLA or VRLA. D. DC-DC Converter for SSI/Data Logger:-Yes, All optional items are required E. DC-DC Converter for Axle Counter-yes, required F. DC-DC Converter for block working :[12-40V, 1 Amp],or [40- 100V, 1 Amp], or [24-32V, 5A] to be decided at the time of LOA G. Type of external & Internal relays;24 V, Q Type Relays. H. DC-DC Converter [3-6V/0.1A] 04 Nos. [for Block Telephone MT] I. Distance between IPS Room to ASM Panel [in Meter] ; 50-100 Meter J. Distance between IPS Rack & Battery [in meter] ; 20-30 meter. K. Whether installation is to be done by OEM-Yes. L. Supply of spares required as per list given below: SN Sub system Spares components Qty. (1) SMPS: Charger Module Module (as cold standby) 01 Module. (2) Inverter Module Module (as cold standby) 01 Module. (3) DC-DC Converter Dc-DC Converter for relay internal relay external and block line or as required by the purchaser 01 Module each. (4) Ferro-resonant Automatic Voltage- Regulator (AVR) AC Capacitor 01 set. (5) Fuses All type of fuses used in IPS sub-system 01 set. (6) Transformer Modular (as cold standby) 02 Module. (7) Inverter/SMR DC Fan 02 Nos. (8) Cells 2V Cells 05 Nos. Block diagram (ECR Sketch) of IPS attached. C.S.I./STORE/DHN Jharkhand 1.00 Numbers
4 Supply, installation & Commissioning of SMPS based IPS Confirming to RDSO specification No. RDSO/SPN/165/2012 (Ver.3.0) or latest Amdt. and Sketch No. SDO/IPS/PI-4L/NRE/ 001 for IPS up to 4 lines without AFTC Non-RE area along with 300 AH Low Maint. Lead Acid Battery. Technical Specification: A. Specification No. :- RDSO/SPN/165/2012 (Ver 3.0) B. Applicable Sketch No. SDO/IPS/PI/4L/NRE/001 C. Type of Battery:300AH LMLA or VRLA. D. DC-DC Converter for SSI/Data Logger:-Yes , All optional items are required. E. DC-DC Converter for Axle Counter-yes, required F. DC-DC Converter for block working :[12-40V, 1 Amp],or [40-100V, 1 Amp], or [24- 32V, 5A] to be decided at the time of LOA. G. Type of external & Internal relays;24 V, Q series relays H. DC-DC Converter [03-6V/.1A] 04 Nos. for Block Telephone /MT I. Distance between IPS Room to ASM Panel [in Meter] ; 50-100 Meter J.Distance between IPS Rack & Battery [in meter] 20-30 meter. K. Whether installation is to be done by OEM-Yes. L. Supply of Spares required as per list given below: SN Sub system Spares components Qty. (1) SMPS: Charger Module Module (as cold standby) 01 Module. (2) Inverter Module Module (as cold standby) 01 Module. (3) DC-DC Converter DC-DC Converter for relay internal relay external and block line or as required by the purchaser 01 Module each. (4) Ferro-resonant Automatic Voltage- Regulator (AVR)AC Capacitor 01 set. (5) Fuses All type of fuses used in IPS sub-system 01 set. (6 )Transformer Modular (as cold standby) 02 Module. (7) Inverter/SMR DC Fan 02 Nos. (8 ) Cells 2V Cells 05 Nos. Block diagram (ECR Sketch) of IPS attached.
5 Supply, installation & Commissioning of SMPS based IPS Confirming to RDSO specification No. RDSO/SPN/165/ 2012 (Ver3.0) or latest Amdt. and Sketch No. SDO/IPS/PI- 4L/RE/002 for IPS up to 4 lines without AFTC RE area along with 200 AH Low Maint. Lead Acid Battery. Technical Specification: A. Specification No. :- RDSO/SPN/165/2012 (Ver 3.0) B. Applicable Sketch No. SDO/IPS/PI-4L/RE/002 C. Type of Battery:200AH LMLA or VRLA D. DC-DC Converter for SSI/Data Logger:-Yes, All optional items are required. E. DC-DC Converter for Axle Counter-yes, required F. DC-DC Converter for block working :[12-40V, 1 Amp],or [40- 100V, 1 Amp], or [24-32V, 5A] to be decided at the time of LOA G. Type of external & Internal relays;24 V, Q Type Relays. H. DC-DC Converter [3-6V/0.1A] 04 Nos.[for Block Telephone /MT] I. Distance between IPS Room to ASM Panel [in Meter] ; 50-100 Meter J.Distance between IPS Rack & Battery [in meter] 20-30 meter. K. Whether installation is to be done by OEM-Yes. L. Supply of spares required as per list given below: SN Sub system Spares components Qty. (1) SMPS: Charger Module Module (as cold standby) 01 Module (2) Inverter Module Module (as cold standby) 01 Module (3) DC-DC Converter DC-DC Converter for relay internal relay external and block line or as required by the purchaser 01 Module each. (4) Ferro-resonant Automatic Voltage- Regulator (AVR) AC Capacitor 01 set (5) Fuses All type of fuses used in IPS sub-system 01 set (6) Transformer Modular (as cold standby) 02 Module (7) Inverter/SMR DC Fan 02 Nos. (8) Cells 2V Cells 05 Nos Block Diagram (ECR Sketch) of IPS attached. SSE/S/W/DHN Jharkhand 9.00 Numbers