Water Supply And Sanitation Department-WSSD has published Providing Laying Jointing Testing Pvc Pipe, Specials For Distribution System, Sluice Valve, Chamber, House Connection For Existing Pipe Line & New Pipe Line, Repair/Replacement Of Pumping Machinery, Control Panel, Repair Of Pump Chamber, Repair Of Ohsr & . Submission Date for this Tender is 30-12-2021. Control Panel Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 23-Jul-2021 | Corrigendum No. 6792-6822 Dated 22.07.2021 | Date | 02-08-2021 |
2 | 03-Aug-2021 | Corrigendum No. 7179-7209 Dated 02.08.2021 | Date | 11-08-2021 |
3 | 12-Aug-2021 | Corrigendum No. 7411-41 Dated 12-08-2021 | Date | 23-08-2021 |
4 | 24-Aug-2021 | Corrigendum No. 7876-7906 Dated 24.08.2021 | Date | 02-09-2021 |
5 | 03-Sep-2021 | Corrigendum No. 8394-8424 Dated 03.09.2021 | Date | 13-09-2021 |
6 | 14-Sep-2021 | Corrigendum No. 8568-98 Dated 14.09.2021 | Date | 27-09-2021 |
7 | 28-Sep-2021 | Corrigendum No. 9004-34 Dated 28.09.2021 | Date | 13-10-2021 |
8 | 14-Oct-2021 | Corrigendum No. 9468-98 Dated 13.10.2021 | Date | 27-10-2021 |
9 | 28-Oct-2021 | Corrigendum No. 9910-9940 Dated 27.10.2021 | Date | 08-11-2021 |
10 | 09-Nov-2021 | Corrigendum No. 14310-40 Dated 08.11.2021 | Date | 16-11-2021 |
11 | 17-Nov-2021 | Corrigendum No. 14846-76 Dated 17.11.2021 | Date | 01-12-2021 |
12 | 02-Dec-2021 | Corrigendum No. 15256-86 Dated 01.12.2021 | Date | 13-12-2021 |
13 | 14-Dec-2021 | Corrigendum No. 15698-15728 Dated 13.12.2021 | Date | 21-12-2021 |
14 | 22-Dec-2021 | Corrigendum No. 17266-96 Dated 22.12.2021 | Date | 30-12-2021 |
Name of Work: Providing Laying jointing testing PVC pipe, specials for Distribution System, Sluice valve, Chamber, House Connection for existing pipe line & new Pipe Line, Repair/Replacement of Pumping Machinery, Control Panel, Repair of Pump Chamber, Repair of OHSR & Development of water works etc. & All other works Contigent there to Complete in all respect at Water Supply Scheme Village Sheron Bagha & Sharon Nigah, Block Rayya, Distt Amritsar. (Under PRWSSIP 2a(i)/JJM) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.\n(Manual excavation and Including specials) | BI01010001010000000000000515BI0100001115 | ||
2 | 2 | 63mm o/d pipe of 6 Kgf. / sqcm | BI01010001010000000000000515BI0100001116 | 50 | mtr |
3 | 3 | 90mm o/d pipe of 6 Kgf. / sqcm | BI01010001010000000000000515BI0100001117 | 100 | mtr |
4 | 4 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).\nClass PN-1 as per ISI | BI01010001010000000000000515BI0100001118 | ||
5 | 5 | 80mm i/d Sluice Valves flanged | BI01010001010000000000000515BI0100001119 | 2 | No. |
6 | 6 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. | BI01010001010000000000000515BI0100001120 | ||
7 | 7 | Size 0.9 m. x 0.9 m. | BI01010001010000000000000515BI0100001121 | 2 | No. |
8 | 8 | Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position | BI01010001010000000000000515BI0100001122 | ||
9 | 9 | 63 mm o/d | BI01010001010000000000000515BI0100001123 | 50 | mtr |
10 | 10 | 90 mm o/d | BI01010001010000000000000515BI0100001124 | 100 | mtr |
11 | 11 | Providing proposed water connection to house hold up to wall with providing, laying jointing testing MDPE pipe lines 15 mm i/d with specials 2.00 mtr (Below GL) and ISI Marked G.I. pipe 15 mm i/d GM ferrule (As per IS:1239) B Class approved make2.50 mtr. (Above GL) including cost of special such as tees, bends, sockets, elbow, etc. cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with C.I bib cock, 15 mm i/d as per IS: 210 with stainless steel spindle of approved make as per CSR 30.65 (b) complete in all respects.\n(Connection at Existing pipe line) 309\n(Connection at New pipe line) 50 | BI01010001010000000000000515BI0100001125 | 359 | No. |
12 | 12 | Cost of Replacement of Machinery Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 330 LPM against a head of 70 mtr (reputed make) complete in all respects as per standard Specifications including Cable as per standard Specifications. . | BI01010001010000000000000515BI0100001126 | 1 | Job |
13 | 13 | Cost of Replacement of control panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. (reputed make) complete in all respects as per standard Specifications. | BI01010001010000000000000515BI0100001127 | 1 | Job |
14 | 14 | Repair of Pump Chamber | BI01010001010000000000000515BI0100001128 | ||
15 | 15 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. (Grills in windows, Grills in ventilator, R.S. Joint on roof, Door, Ventilator,Windows .etc) | BI01010001010000000000000515BI0100001129 | 23.85 | Sqm |
16 | 16 | White washing 3 coats inside of pump chamber. | BI01010001010000000000000515BI0100001130 | 13.08 | Sqm |
17 | 17 | Finishing walls with exterior water soluble paint cement based such as snowecem, robbiacem etc. on old work one coat to give an even shade. | BI01010001010000000000000515BI0100001131 | 73.31 | Sqm |
18 | 18 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.\nGlass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area | BI01010001010000000000000515BI0100001132 | 6.9 | Sqm |
19 | 19 | RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- | BI01010001010000000000000515BI0100001133 | ||
20 | 20 | Wiring fan point (Without fan box) | BI01010001010000000000000515BI0100001134 | 1 | No. |
21 | 21 | Wiring light point | BI01010001010000000000000515BI0100001135 | 3 | No. |
22 | 22 | Wiring 6Amp. Plug control comprising wall socket point | BI01010001010000000000000515BI0100001136 | 2 | No. |
23 | 23 | Wiring 16/20Amp. power plug control point | BI01010001010000000000000515BI0100001137 | 1 | No. |
24 | 24 | Providing and fixing of ceiling fan of reputed make such as Crompton or equivalent | BI01010001010000000000000515BI0100001138 | 1 | No. |
25 | 25 | Repair of OHSR | BI01010001010000000000000515BI0100001139 | ||
26 | 26 | Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects. | BI01010001010000000000000515BI0100001140 | 1 | Job |
27 | 27 | Repair of 6" Expansion joint Complete in all respects. | BI01010001010000000000000515BI0100001141 | 3 | No. |
28 | 28 | OHSR Plinth Protection | BI01010001010000000000000515BI0100001142 | ||
29 | 29 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. | BI01010001010000000000000515BI0100001143 | 4.9 | Cum |
30 | 30 | Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type | BI01010001010000000000000515BI0100001144 | 1.6 | Cum |
31 | 31 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth | BI01010001010000000000000515BI0100001145 | 3.63 | Cum |
32 | 32 | 12.5 mm thick cement plaster 1:4 | BI01010001010000000000000515BI0100001146 | 12.28 | Sqm |
33 | 33 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres | BI01010001010000000000000515BI0100001147 | 11.85 | Cum |
34 | 34 | Stone (building or pitching) Sand, Earth, Fly Ash, Bajri, Shingle, Spalls, Brick bats, Brick ballast and Stone metal. | BI01010001010000000000000515BI0100001148 | 6.95 | Cum |
35 | 35 | Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type | BI01010001010000000000000515BI0100001149 | 4.01 | Cum |
36 | 36 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material | BI01010001010000000000000515BI0100001150 | 45.38 | Sqm |
37 | 37 | Finishing wall with cement based water soluble exterior paint such as snowcem robbiacem etc. on new work in two coats to give even shade. | BI01010001010000000000000515BI0100001151 | 7.35 | Sqm |
38 | 38 | Development of water works | BI01010001010000000000000515BI0100001152 | ||
39 | 39 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing. | BI01010001010000000000000515BI0100001153 | 670 | mtr |
40 | 40 | Providing & Fixing D hook complete with MS bolt size 300 mm x18 mm as per standard drawing D-7 & Analysis of Rates A-9 complete in all respects. | BI01010001010000000000000515BI0100001154 | 24 | Nos. |
41 | 41 | Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects including carriage. | BI01010001010000000000000515BI0100001155 | 45 | Nos. |
42 | 42 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3. | BI01010001010000000000000515BI0100001156 | 4 | No. |
43 | 43 | Construction of foot paths with masonry toe wall& earth filling & concrete topping; inside water works as per standard drawing D-10 & Analysis of Rates A-11 complete in all respects. | BI01010001010000000000000515BI0100001157 | 52 | mtr |
44 | 44 | Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-4 complete in all respects | BI01010001010000000000000515BI0100001158 | 1 | No. |
45 | 45 | Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing D-20 | BI01010001010000000000000515BI0100001159 | 1 | No. |
46 | 46 | Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications. | BI01010001010000000000000515BI0100001160 | 1 | Job |
47 | 47 | Extra Carriage of Sand (Fine Aggregate) | BI01010001010000000000000515BI0100001161 | 17.91 | Cum |
48 | 48 | Extra Carriage of Bajri (Course Agrregate) | BI01010001010000000000000515BI0100001162 | 23.42 | Cum |