}

Providing And Fixing Of Electrification Facility To Imamai Hall At Pandrathan , Sriangar Providing And Fixing Of Electrification Facility To Imamai Hall At Pandrathan , Sriangar . , Srinagar-Jammu And Kashmir

Tourism Department has published Providing And Fixing Of Electrification Facility To Imamai Hall At Pandrathan , Sriangar Providing And Fixing Of Electrification Facility To Imamai Hall At Pandrathan , Sriangar . . Submission Date for this Tender is 26-07-2021. Electrification Work Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

28504994
Providing And Fixing Of Electrification Facility To Imamai Hall At Pandrathan , Sriangar Providing And Fixing Of Electrification Facility To Imamai Hall At Pandrathan , Sriangar .
Open Tender
Indian
Jammu And Kashmir
Srinagar
26-07-2021

Tender Details

Providing And Fixing Of Electrification Facility To Imamai Hall At Pandrathan , Sriangar Providing And Fixing Of Electrification Facility To Imamai Hall At Pandrathan , Sriangar .

Key Value

Document Fees
INR 200 /-
EMD
INR 1.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Providing and fixing of Electrification facility to Imamai Hall at Pandrathan, Sriangar
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Anchor/ Eq. make) single core cable in surface / recessed medium class PVC conduit ( Anchor/ Alba make), with modular switch ( Anchor roma urban/ Eq. make), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. BI01010001010000000000000515BI0100001114 58 Point
2 2 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor ( Havell/Anchor/ Eq. make) single core cable in surface/recessed medium class PVC conduit ( Anchor/ Alba make), alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 120 Meter
3 3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Anchor/ Eq. make), single core cable in surface/ recessed medium class PVC conduit as required.
4 4 (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 85 Meter
5 5 ( C ) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 70 Meter
6 6 Supplying and fixing of following sizes of medium class PVC conduit ( Anchor/ Alba/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
7 7 25mm 50 Metre
8 8 Supply and fixing of 6/16 amp/230 V AC 6 pin sockets with cover plate Anchor Roma urban/SSK NV/ Eq. make. 5 No
9 9 Supply and fixing of 16/20 amp/230 V AC one way switch with cover plate Anchor Roma urban/SSK NV/ Eq. make. 5 No
10 10 Supply and fixing of 6 amp/230 V AC 5 pin sockets with cover plate Anchor Roma urban/SSK NV/ Eq. make. 5 No
11 11 Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma urban/SSK NV/ Eq. make. 10 No
12 12 Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends. 15 No
13 13 S/F testing and comm. Of recessed/ surface mounted ceiling 15 Watt LED down lighters ( commercial series of approved make) philips / Havell/ Bajaj/ Crompton make of eq. standard. 35 No
14 14 S/F testing and comm. Of surface mounted LED Batten 4 ft. Philips make / Havell/ Bajaj/ Crompton make of eq. standard. 3 No
15 15 S/F testing and comm. Of MCB's of the below mentioned capacities in sub main controls legrand C curve Series.
16 16 b) 6-32 Amp SP MCB 12 No
17 17 c) 40-63amp DP MCB 6 No
18 18 Supply installation testing and comm. of distribution Board 16 way double door Horizontal Distribution Board Legrand/ Eq. make. 1 No
19 19 Supply installtion testing and comm .of 9" sweep exhaust fan heavy duty of Havell/Bajaj/Crompton make. 6 No
20 20 Supply installation testing and comm. Of 1200 mm ceiling fan Model oyster Metallic Havell make/ Bajaj/Crompton(Flavia) of eq. standard ( strictly as per approved sample) 10 No
21 21 Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block. 10 No
22 22 Supply, laying partly overhead partly underground, testing and comm. Of 16mm 2 core 650/1100 V grade unarmoured Aluminium cable Havell/Eq. standard make. 60 Meter
23 23 Providing and fixing of Al.thimble 10-35mm sq. 15 No
24 24 Supply installation testing and comm.of invertor battery 180 AH/12 V Exide invatubular/ Su-kam /Luminous make. 2 No
25 25 Supply installation testing and comm.of inverter along with trolly of following rating Microtek/Sukam/Luminous make. ( strictly as per approved sample)
26 26 a)1400 VA 1 No
27 27 Supply installation testing and comm. of die cast aluminium IP66 flood light 50 W with high power LED's as light source Street lighting luminaire Philips/ Havell ( JETA IRIS)/Eq. Standard make 3 No
28 28 Supply installation testing and comm. Of 2'x1'.6"x1' control pannel outdoor type sheet steel 16SWG powder coated phosphatised having angle iron stand fitted with following accessories to be grouted in the cement concrete, complete job
29 29 a) 200 amp 4 strip bus 1 No.
30 30 b) A/V meters set/indicators
31 31 c) space for 12 way MCB's
32 32 d) 100 DP MCB Legrand make 1 job
33 33 Providing of earthing using G.I plate earthing and G.I strip risers along with associated material as per I.S standards 2 No
34 34 S/I testing and comm. Of single phase 7 KVA 50HZ oil cooled(Transformer oil is to be provided with stabilizer conforming to IS 335,IEC296)) servo voltage stabilizer(Electricfield / Alba/ Cosco make) having an input line voltage ranging from 90V to 270 V ( phase voltage) and balanced output voltage of 220V, +/- 1%. ( Test certificate to be provided by the manufacturer) The unit incorporate
35 35 a) 0-500V moving iron type voltmeter with selector switch, indicating lights, adjustment of auto/mannual selector switch.
36 36 e) Single phase Preventer , time delay of 10 Secs, low cut and high cut.
37 37 h) 20 % over load bearing capacity for one hour. 1 No
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail