Augmentation Of Providing Water Supply Scheme Village Abadi Channa Ghoga, Ghoga (Mh-Fc) Block Chogawan Distt Amritsar (Under Punjab Rural Water & Sanitation Sector Improvement Project (1A-Iii/Hp)Part - A Drilling Installation And Commissioning Of 150Mm I/, Amritsar-Punjab

Water Supply And Sanitation Department-WSSD has published Augmentation Of Providing Water Supply Scheme Village Abadi Channa Ghoga, Ghoga (Mh-Fc) Block Chogawan Distt Amritsar (Under Punjab Rural Water & Sanitation Sector Improvement Project (1A-Iii/Hp)Part - A Drilling Installation And Commissioning Of 150Mm I/. Submission Date for this Tender is 26-09-2022. Pumping Machiney Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

28504266
Corrigendum : Augmentation Of Providing Water Supply Scheme Village Abadi Channa Ghoga, Ghoga (Mh-Fc) Block Chogawan Distt Amritsar (Under Punjab Rural Water & Sanitation Sector Improvement Project (1A-Iii/Hp)Part - A Drilling Installation And Commissioning Of 150Mm I/
Open Tender
Indian
Punjab
Amritsar
26-09-2022

Tender Details

Augmentation of Providing Water Supply Scheme Village ABADI CHANNA GHOGA, GHOGA (MH-FC) Block Chogawan Distt Amritsar (Under Punjab Rural Water & Sanitation Sector Improvement Project (1A-III/HP)Part - A Drilling Installation and commissioning of 150mm i/d T/well & 120 mtr depth, Construction of Pump Chamber 2.20 x 2.20mtr , Construction of one No. RCC OHSR 25000 ltrs capacity having height 17.20m up to FSL and 15.50m upto top of bed level, Plinth Protection around OHSR, providing and fixing double flanged pipes, valves and specials, automatic water level control device etc, Providing & fixing Pumping Machinery, Rising Main, Development of Water works and Distribution system and all other works contingents there to. PART - BOperation & Maintenance of entire water supply scheme including Pump oprator cum-chowkidar,, lawns with fine grassing & ornamental plants with manure & watering etc for three month aftercompletion at water work site. Sodium Hypochlroide Solution for Disinfecting (cost for 3 months)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Jul-2021 Corrigendum No. 3661 Dated 29-07-2021 Date 05-08-2021
2 05-Aug-2021 corrigendum no. 3777 dated 05-08-2021 Date 12-08-2021
3 12-Aug-2021 Corrigendum No. 3861 Dated 12-08-2021 Date 19-08-2021
4 19-Aug-2021 Corrigendum No. 3934 Dated 19-08-2021 Date 26-08-2021
5 27-Aug-2021 Corrigendum No. 4120 Date 02-09-2021
6 03-Sep-2021 Corrigendum no. 4220 dated 02-09-2021 Date 09-09-2021
7 09-Sep-2021 COrrigendum No. 4267 Dated 09-09-2021 Date 16-09-2021
8 16-Sep-2021 Corrigendum No. 4461 Dated 16-09-2021 Date 23-09-2021
9 24-Sep-2021 COrrigendum No. 4527 Dated 23-09-2021 Date 30-09-2021
10 01-Oct-2021 Corrigendum No. 4657 Dated 01-10-2021 Date 11-10-2021
11 11-Oct-2021 Corrigendum No. Spl-1 Dated 11-10-2021 Date 18-10-2021
12 18-Oct-2021 Corrigendum No. Spl-1 Dated 18-10-2021 Date 25-10-2021
13 25-Oct-2021 Corrigendum No. Spl-17 Dated 25-10-2021 Date 01-11-2021
14 02-Nov-2021 Corrigendum No. Spl-02 Dated 02-11-2021 Date 08-11-2021
15 08-Nov-2021 Corrigendum No. 4870 Dated 08-11-2021 Date 15-11-2021
16 15-Nov-2021 Corrigendum No. 5108 Dated 15-11-2021 Date 22-11-2021
17 23-Nov-2021 Corrigendum No. 5156 dated. 22-11-2021 Date 29-11-2021
18 29-Nov-2021 Corrigendum No. 5275 Dated 29-11-2021 Date 06-12-2021
19 07-Dec-2021 corrigendumno.6178 dated07-12-2021 Date 13-12-2021
20 13-Dec-2021 Corrigendum No. 6268 Dated 13-12-2021 Date 20-12-2021
21 20-Dec-2021 Corrigendum No. 6720 Dated 20-12-2021 Date 27-12-2021
22 27-Dec-2021 Corrigendum No. Spl-5 Dated 27-12-2021 Date 03-01-2022
23 03-Jan-2022 Corrigendum No 6836 Dated 03-01-22 Date 17-01-2022
24 17-Jan-2022 Corrigendum No. 224 Dated 17-01-2022 Date 31-01-2022
25 31-Jan-2022 Corrigendum No. 390 Dated 31-01-2022 Date 14-02-2022
26 14-Feb-2022 Corrigendum No. 747 Dated 14-02-2022 Date 22-02-2022
27 22-Feb-2022 Corrigendum No. 853 Dated 22-02-2022 Date 02-03-2022
28 02-Mar-2022 Corrigendum No. 1011 Dated 02-03-2022 Date 09-03-2022
29 09-Mar-2022 Corrigendum No. 1227 Dated 09-03-2022 Date 16-03-2022
30 17-Mar-2022 Corrigendum NO. 1451 dated 17-03-2022 Date 28-03-2022
31 28-Mar-2022 Corrigendum No. 1740 Dated 28-03-2022 Date 04-04-2022
32 05-Apr-2022 Corrigendum No. 3012 Dated 05-04-2022 Date 11-04-2022
33 11-Apr-2022 Corrigendum No. 2348 Dated 11-04-2022 Date 18-04-2022
34 18-Apr-2022 Corrigendum No. 2451 Dated 18-04-2022 Date 21-04-2022
35 22-Apr-2022 Corrigendum No. 2572 Dated 21-04-2022 Date 28-04-2022
36 28-Apr-2022 Corrigendum No. 2927 Dated 28-04-2022 Date 05-05-2022
37 06-May-2022 Corrigendum No. 3067 Dated 05-05-2022 Date 12-05-2022
38 13-May-2022 Corrigendum NO. 3337 Dated 13-05-2022 Date 19-05-2022
39 20-May-2022 Corrigendum No. 3522 Dated 19-05-2022 Date 26-05-2022
40 27-May-2022 Corrigendum No. 3688 Dated 27-05-2022 Date 01-06-2022
41 01-Jun-2022 Corrigendum No. 3832 Dated 01-06-2022 Date 08-06-2022
42 08-Jun-2022 Corrigendum No. 3893 Dated 08-06-2022 Date 15-06-2022
43 15-Jun-2022 Corrigendum No. 3934 Dated 15-06-2022 Date 22-06-2022
44 22-Jun-2022 Corrigendum No. 4059 Dated 22-06-2022 Date 29-06-2022
45 30-Jun-2022 Corrigendum No. 4151 Dated 29-06-2022 Date 06-07-2022
46 07-Jul-2022 Corrigendum No. 4299 Dated 06-07-2022 Date 13-07-2022
47 13-Jul-2022 Corrigendum No. 4405 Dated 13-07-2022 Date 25-07-2022
48 25-Jul-2022 Corrigendum No. 4622 Dated 25-07-2022 Date 01-08-2022
49 02-Aug-2022 Corrigendum No. 4739 Dated 02-08-2022 Date 08-08-2022
50 09-Aug-2022 Corrigendum No. 4888 Dated 08-08-2022 Date 16-08-2022
51 16-Aug-2022 Corrigendum No. 5005 Dated 16-08-2022 Date 23-08-2022
52 23-Aug-2022 Corrigendum No. 5041 Dated 23-08-2022 Date 30-08-2022
53 31-Aug-2022 Corrigendum No. 5066 Dated 30-08-2022 Date 06-09-2022
54 06-Sep-2022 Corrigendum No. 5278 Dated 06-09-2022 Date 15-09-2022
55 16-Sep-2022 Corrigendum no. 5414 dated 15-09-2022 Date 26-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 77500.0 /-
Tender Value
INR 38.59 Lakhs /-

BOQ Items

Name of Work:- Augmentation of Providing Water Supply Scheme Village ABADI CHANNA GHOGA, GHOGA (MH-FC) Block Chogawan Distt Amritsar (Under Punjab Rural Water & Sanitation Sector Improvement Project (1A-III/HP) Part - A Drilling Installation and commissioning of 150mm i/d T/well & 120 mtr depth, Construction of Pump Chamber 2.20 x 2.20mtr , Construction of one No. RCC OHSR 25000 ltrs capacity having height 17.20m up to FSL and 15.50m upto top of bed level, Plinth Protection around OHSR, providing and fixing double flanged pipes, valves and specials, automatic water level control device etc, Providing & fixing Pumping Machinery, Rising Main, Development of Water works and Distribution system and all other works contingents there to". PART - BOperation & Maintenance of entire water supply scheme including Pump oprator cum-chowkidar,, lawns with fine grassing & ornamental plants with manure & watering etc for three month aftercompletion at water work site. Sodium Hypochlroide Solution for Disinfecting (cost for 3 months)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory,transportation to site and vice versa etc. complete in all respect.\nBoring with 200mm I/d Housing Pipe\n0 to 120m iteam1 120 Mtr
2 2 Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.\n150mm nominal diameter (weight 21.6 kg per meter) 5.4mm thickness iteam2 106 Mtr
3 3 Supplying, fixing & lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest ISI Marked, Duly welded with suitable grade S.S welding electrode to lower the strainer into tube well bore.\n150mm steel strainer (slot size 0.15/0.20 mm) 5.00 mm thickness iteam3 10 Mtr
4 4 Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest, ISI Marked duly welded with suitable grade SS Welding electrode to lower the strainer into tubewell bore complete in all respect\n150mm internal diameter iteam4 3 Each
5 5 Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect.\n150 mm internal diameter iteam5 4 Each
6 6 Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. iteam6 1 Each
7 7 Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect iteam7 1 Each
8 8 Supplying & fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect.\n150mm internal diameter (weight 21.6 kg per meter) 5.4 mm thickness iteam8 4 Mtr
9 9 Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect \n150 mm internal diameter iteam9 1 Each
10 10 Development of stabilizing of the tube well with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. \nCapacity of Air compressor 300 cfm at 250 PSI iteam10 10 Hrs
11 11 Development of stabilizing of the tube well with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. iteam11 4 Hr
12 12 Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) iteam12 3 Each
13 13 Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) iteam13 1 Each
14 14 Provision for Sanitary Clay Seal (as per BIS Code IS 2800: 2019) including Sterlization of Tubewell iteam14 1 L.S.
15 15 Construction of one No. RCC OHSR having capacity 25 KL (25,000 ltrs) height 17.20 mtr. up to FSL & 15.50 mtr. up to sill level from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single man hole cover lightening conductor, aluminium ladder inside tank portion etc. complete as decribed in schedule No. 3. Providing & fixing DI/D/F expansion joint conforming to IS -1536-1989 or latest and bail mouth and D/F puddle collars as per DWSS design, Duck foot bends conforming to ISI-13382 and CI/DF sluice Valve duly ISI marked ( IS 14846-2000 or latest) one each with inlet, outlet and scour pipes including providing and installing intel, outlet, scour pipes and overflow DI double flanged pressure pipes horizontally cast in sand moudls as per IS 8329-2000 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel and painting of all complete shall be included in cost complete in all respect as per specifications. . \n\n(The specification & drawing are based on safe bearing capacity of soil of 8.75 tones per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per sqm. the contractor shall submit his own design for foundation portion based on actual safe bearing standard capacity as per DWSS specifications. The difference in quantites from the standard drawing based on 8.75 tone per sqm. to the safe bearing capacity will be paid as per CSR+prevalling celling premium). It also includs, providing & fixing automatic Electronic water level control device and construction of Plinth protection around OHSR with masonary toe wall with 40mm thick CC 1:2:4 on top over 100mm thick CC 1:8:16 & inside earth filling including overflow haudi complete in all respects. iteam15 1 OHT
16 16 Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 155 LPM against a head of 53 mtr along with electric panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. including G.I. Column Pipe of suitable size 50 mm =31 mtr (in 3 mtr lengths each with flanges , screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable (reputed make) complete in all respects as per standard Specifications. iteam16
17 16.01 Cost of pumping set iteam17 1 No.
18 16.02 Cost of lowering (with length) Size 50mm iteam18 31 Mtr.
19 16.03 Cost of submersible Cable (with Length) Size 2.50mm iteam19 35 Mtr.
20 16.04 Cost of Panel Board iteam20 1 Job
21 17 Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Annexure A12 – 2 & Drawings D-12 & D-17. iteam21 1 Each
22 18 Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (Manually) (6kgf/cm2) (excavation & including specials) iteam22
23 18.01 PVC pipe 63mm o/d (6kgf/cm2) iteam23 327 Mtr.
24 18.02 PVC pipe 90mm o/d (6kgf/cm2) iteam24 36 Mtr.
25 19 Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (Mechnically) (6kgf/cm2) (excavation & including specials) iteam25
26 19.01 PVC pipe 63mm o/d (6kgf/cm2) iteam26 2656 Mtr.
27 19.02 PVC pipe 90mm o/d (6kgf/cm2) iteam27 801 Mtr.
28 20 Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. iteam28
29 20.01 PVC pipe 63mm o/d iteam29 1103 Mtr.
30 20.02 PVC pipe 90mm o/d iteam30 289 Mtr.
31 21 Dismantling of cement concrete road and restoration in original condition iteam31 315 Mtr.
32 22 Hand boring Horizontly for crossing of pipe under road or any other obstacle by Auger/Bocki method. Including excavation, stringing and jointing of pipe upto 160mm complete. iteam32 12 Mtr.
33 23 Providing, fixing and jointing ISI Marked Gun-Metal peet valves (Heavy pattern) as per IS 778 with hand wheels, on GI Pipe lines laid in the ground or inside buildings including all carriages complete\n50MM i/d Gun Metal peet valve heavy pattern iteam33 8 Each
34 24 Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)\nClass PN-1 as per ISI\n80mm I/d iteam34 2 Each
35 25 Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete \n1 kg I.e (2 x1 = 2kg) iteam35 2 Kg.
36 26 Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department with each of Size 0.6m x 0.6m iteam36 2 Each
37 27 Providing proposed water Connection to household up to wall with providing ,laying, jointing, fixing, testing MDPE pipe line 15 mm i/d = 2.00 mtr(Below GL) and ISI Marked G.I. Pipe 15 mm i/d (As per IS 1239) B-Class approved make = 2.50 mtr (Above GL) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM Ferrule as per IS:2692 and 3" i/d clamp with CI Bib Cock 15 mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete in all respects. iteam37 135 Nos.
38 28 Providing & Fixing proposed (Brass Ball Valve 15mm i/d, GI Nipples 15mmx150mm 15mmx100mm, GI Elbow, GI Union, GI Hooks & GI Filter Including ISI Marked Water Meter Complete in all respects all respects. iteam38 135 Nos.
39 29 Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications. iteam39 1 Job
40 30 Construction of Pump Chamber Below OHSR Size2.20x2.20m including electric wiring as per analysis, Complete in all respects. iteam40 1 Job
41 31 Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8. iteam41 282 mtr
42 32 Providing & Fixing PCC Fencing Poles With 6' height, 3" x 3" Top & 4" x 3" Base provided with 3 nos. hooks complete in all respects iteam42 39 Each
43 33 Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7. iteam43 30 Each
44 34 Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3. iteam44 4 Each
45 35 Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-4 complete in all respects iteam45 1 Each
46 36 Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-7. iteam46 20 mtr
47 37 Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing D-20 iteam47 1 Each
48 38 Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (Mechnically) (10kgf/sqcm) (excavation & including specials) \n(iii) 110mm o/d pipe of 10 Kgf/sqcm iteam48 30 mtr
49 39 Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)\n100mm o/d iteam49 2 Each
50 40 Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (2 no. each of size 0.9m x 0.9m iteam50 2 Each
51 41 Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capacity as per guidelines issued by PEDA complete in all respects.\n(Solar Panel Energy System Deduct 1 km produced 4 units per day) iteam51 3 K.W.
52 42 Operation & Maintenance of entire water supply scheme including Pump oprator cum-chowkidar, consumables, lawns with fine grassing & ornamental plants with manure & watering etc for three month aftercompletion at water work site. Sodium Hypochlroide Solution for Disinfecting (cost for 3 months) iteam52 1 Job
53 43 Rough grassing including uprooting rank vegetation and weeds by digging the area to a depth of 15 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, mixing fertilizer, levelling and dressing for planting new grass, including disposal of all rubbish with all leads and lifts, planting doob grass in rows 15 cm apart in both directions, watering and maintenance till first mowing. iteam53 77 sqm
54 44 Digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control iteam54 3 cum
55 45 Supplying and planting permanent trees in prepared pits and watering iteam55 3 Each
56 46 Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row. iteam56 4 sqm
57 47 Planting bulbous flower beds including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 30cm distance from plant to plant and row to row. iteam57 2 sqm
58 48 Provision for one way stand post with khura complete in all respect. iteam58 1 Job
59 49 Carriage of Bajri (Course Agrregate) iteam59 58.84 cum
60 50 Carriage of Sand (Fine Aggregate) iteam60 35.64 cum
61 51 CONDITIONS :- iteam61
62 51.01 Item for which no rate or price has been entered in will not be paid for the Employer when execut6ed and shall be deemed covered by the other rates and prices in the Bill of Quantities. iteam62
63 51.02 Unit rates and prices shall be quated by the bidder in indian ruppees. iteam63
64 51.03 Where there is a discrepancy between the rate in figures and words, the rates in words will govern. iteam64
65 51.04 Where there is a discrepancy between the rate and the line total resulting from muluplying the unit rate by quantity the unit rate quoted shall govern. iteam65
66 51.05 Any item of work not included in the above contract schedule of rates and got done at the site of work; the same will be paid according to CSR-2010 subject to the premium or discount tendered by the contractor. In the case of non-schedule items, the decision of the Engineer-in-charge will be final and binding upon the contractor. In case any item which is a part of lump-sum rate is be deducted @CSR rates + Ceiling premium prevailing on the date of tender iteam66
67 51.06 The work will be carried out in accordance with PWD Book of specifications - 1963 edition with upto date amendments. iteam67
68 51.07 Approximate quantities are given in the contract schedule of rates and these can vary at the time of execution of the work. The payment will be made according to the actual work done by the contractor. iteam68
69 51.08 All amendments issued on the common schedule of rates 2010. up to the date of opening of tenders will be applicable on the contract schedule of rates. iteam69
70 51.09 Contractor should clearly quote his rates in figures & words. Conditional tender will be rejected. iteam70
71 51.1 All items and rates provided in the DNIT are subject to the footnotes give in CSR-2010 iteam71
72 51.11 The Engineer-in-charge will have full powers to change the layout of the work covered in this contract if considered necessary. iteam72
73 51.12 No claim will be entertained form the contractor in case, any mistake in description rates or unit occurs in any item taken in this schedule while preparing this DNIT or on account of typing or comparison or over writing. The same will be rectified at any time as per common schedule of rates 2010 along with upto date amendments. iteam73
74 51.13 The arrangements of bricks at site of work would be done by the contractor at his own level from his own source. iteam74
75 51.14 For any other non-schedule items, the contractor will submit through Engineer-in-charge, the analysis of rates in triplicate based on purchased vouchers. A margin of 10% shall be allowed for material components and 21.5% on labour components and contractor shall produce photo stat copies of the purchase vouchers in support of his claim. The decision of the Engineer-in-charge/Competent authority in the matter shall be final and binding on the contractor. iteam75
76 51.15 All the extra items will be got approved from the competent authority and no premium will be allowed on non schedule item iteam76
77 51.16 Pavement for the carriage of material shall be paid as per the rates quoted by the tenderer. iteam77
78 51.17 Time period allowed for completion of work in 12 months. Including 3 months O & M iteam78
79 51.18 If contractor allowed for completion of work within 7 days from the date of allotment, DWSS reserve the right to impose penalty or withdraw the work and propose action for debarring in future tendering or both; decision of Chief Engineer (North) shall be binding. iteam79
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail