Electrification Work Of Construction Of Rcc 3 Storied Ps At Dispur P.S. In Kamrup ( M ) District Under Moitri Scheme, Dispur P.S. in Kamrup(M) District-Assam

Assam Police Housing Corporation Ltd has published Electrification Work Of Construction Of Rcc 3 Storied Ps At Dispur P.S. In Kamrup ( M ) District Under Moitri Scheme. Submission Date for this Tender is 26-07-2021. Electrification Work Tenders in Dispur P.S. in Kamrup(M) District Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28336448
Corrigendum : Electrification Work Of Construction Of Rcc 3 Storied Ps At Dispur P.S. In Kamrup ( M ) District Under Moitri Scheme
Open Tender
Indian
Assam
Dispur P.S. in Kamrup(M) District
26-07-2021

Tender Details

Electrification Work Of Construction Of Rcc 3 Storied Ps At Dispur P.S. In Kamrup ( M ) District Under Moitri Scheme

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Jul-2021 Corrigendum Notice Technical Bid 16-07-2021
2 15-Jul-2021 Date Corrigendum Notice Date 26-07-2021

Key Value

Document Fees
INR 7000 /-
EMD
INR 156388.0 /-
Tender Value
INR 78.19 Lakhs /-

BOQ Items

Name of Work : Electrification Works of Construction ofRCC 3-storied Police Station Building (including accommodation of DCP and Traffic Branch) with provision of Reception & Conference Hall with Cyber Room & Work Station & Women Cell & Counseling Room for Drug ADICT & JUVENILE & Boundary Wall, Gate, Approach Road, Deep Tube Well etc. in existing Police Station at Dispur P.S. in Kamrup(M) District under MOITRI Scheme.
Sl. No. Item Description
1Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete. Short point up to 3.00 metre. length.
2Medium point up to 6.00 metre. Length.
3Long point up to 10.00 metre. Length.
4Wiring for 5 pin 6 amp plug with 1.5 sq mmP.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socketas required on the switch board in surface/ recessedP.V.C. conduit wiring system. When fitted on same board of light and fan.
5Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedPVCconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
6Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
7With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
8With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cablein 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
9Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedPVC20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 6 sq. mm. + earth continuity with 2X4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
10With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
11Supplying and fitting fixing of Electric storage water heater [Geyser] ofBajaj/Crompton/Racold/V. Guard or equivalent make including necessary connection cable,as approved by the Deptt.)etc. as required complete and as directed by the Department. (I 15.00 litres. Capacity(5 Star Model)(Crompton/Racold/V. Guard or equivalent make)
12Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.ABB, Schneider MG, legrand, Hagermake) 6 way TPN (4+18)double door
13Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 6 way SPN double door
148 way SPN double door
1512 way SPN double door
16Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hagermake) 6 to 32A
17Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hagermake) 6 to 32A
18Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hagermake)40A
19Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure)of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemensmake)160A
20Supplying with fitting and fixing Four Pole 415V Front handle operated open execution On Load Change over switchfitted on the existing cubical panel of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider, legrand, L&Tmake) 125 A
21Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 1.35M X 1.50MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and35mm X 35mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:1. 20mm X 3mm 4 strip copper Bus-Bar 1.0 M length each 2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no 3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 no 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 5. Voltmeter & Ammeter Selector Switch- 2 no 6. 2 A Slide fuse unit - 3nos (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
22Supply, installation & testing of Copper Plate earth station with600 mmx600 mmx3 mm copper earth plate withnecessary 40 mm dia. G.I. medium duty watering pipewith G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
23Supply, installation & testing of G.I. Plate earth station with600 mmx600 mmx6 mm heavy duty G.I. earth plate withnecessary 40 mm dia. G.I. watering pipewith G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mmhinged cover C.I. cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
24Extra for using salt (5 Kand Charcoal (96 Kin G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
25Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
26Supplying & laying of32*6 mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
27Supplying & laying offollowingsize 25*4 mm Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply ofBrass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
28Supply with installation & commissioning of readymade maintenance free CPRI approved chemical earthing system with 50 mm dia. 3.00 Metres length corrosion free dual pipetechnology G.I.CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 Kand Advance Earth Pit cover (PVincluding excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
29Supply with fitting, fixing ofLED Tube Light 20 Watt (Bajaj/ Polycab/ Philips)
30Supply with fitting, fixing of Edge LED Street Light luminaries 45 Watt LED (Bajaj/ Syska/ Crompton)
31Supply with fitting, fixing of Slim compact, aluminium die cast edge lit panel recessed mounted round fixture with opal diffuser and separate electronic driver 12 W LED (Havells/ Jaquar/ Philips)
32Suppliying and fixing of Jaquar or equivalent Philips/Wipro LED spot light fittings complete with Shade,back plate including connection cable,as approved by the Deptt.s etc. as required. LED Square front spot light,3W
33Supplying including fitting fixing of followingA.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator].Premium model1200 mm Sweep (ORIENT PSPOmake) / Premium model 1050 /1200 mm Sweep SS-390 Deco Havellsmake)
34Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
35Supplying including fitting fixing of followingA.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. (CROMPTON /ORIENT/Havells/USHA or equivalentmake) Swing platinawith plastic blade, 400 mm sweep
36Supply with fitting and fixing of 120 Watt electronic modular STEP speed control 2-modue type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE),MK (BLENZE), SCHINEDER (ZENSELO), CRABTREE (MURANO) including making necessary connections as per direction of deptt. 120 Watt electronic modular step speed control 2-module type BLK
37Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Power Flow225 mm sweep (ORIENTmake)
38Supplying with installation testing and commissioning of Hi -- wall 3 STAR rating non ducted split typeair conditioner of the following capacity with cordless remote complete withindoor and outdoor unit, copper pipeand electrical connection up to 5 m between the room unit and out door unit as approved by the Deptt.) and as directed by the department.1.5 Ton Capacity Voltasmake) Model silver 3S
392 Ton Capacity Voltasmake) Model silver 3S
40Supplying with fitting and fixing of Angle iron framing made 50 mmx50 mmx5 mm size angle iron for accommodation of 1.00 Ton to 2.00 Ton Window/split type A.C. Machine
41Copper pipeincluding cable fitting ( 1/4,1/2,5/8)
42Supplying with fitting & fixing of 25 Amp modular motor starter 2 Amp MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connectionss as per direction of deptt.
43Supplying with fitting and fixingVoltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUSmake) 4.0 KVA Automatic Input 90-280 V Out put 200-240 V
445.0 KVA Automatic Input 90-280 V Out put 200-240 V
45Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 armoured U.G. cableU.G. cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 95.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
46120.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
471.Call bellwith indicator(Legrand/ C&S or equivalent as approved by the Deptt.)make)
48Supplying including installtion of socket outlet 10/16 Amps 3/5 pin combine shuttered complete, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connections as per direction of deptt.
49Supply with fitting and fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connections as per direction of deptt.
50Supply with fitting and fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connections as per direction of deptt.
51Supply including installation of socket outlet 6/10/13 Amps International Socket, Model Range Legrand (Arteor), Achor (Ave), MK (Blenze), Schneider (Zenselo), Crabtree (Murano) including making necessary connection as per direction of department
52Supply with fitting and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) in surface/recessed system complete as per direction of deptt. 1-2 module type Metal
533 module type Metal
544 module type Metal
556 module type Metal
5612 module type Metal
5718 module type Metal
58Supplying including fitting & fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) front plate of suitable color as per direction of deptt. 2 module
59Supplying including fitting & fixing of TV SOCKETMODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connectionss as per direction of deptt.
60Supply and laying of following size gas injected physical polyethylene foam insulation with laminated Al tape and Al braid, jelly flooded PVC black jacketed industrial co-axial cable armoured cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .RG 11 armoured
61Supply and fixing of 19 mm dia 1.50mm to 2.00mm average wall thicknessheavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface systemincluding painting etc as required:
62Supply and fixing of 25 mm dia 1.50mm to 2.00mm average wall thicknessheavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface systemincluding painting etc as required:
63Supplying with fitting & fixing of CAT 6 RJ-45 computerjack in one module, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connectionss as per direction of deptt.
64Supply with fitting, fixing of8 port LAN Switch (D-Link)
65Supply with fitting, fixing of4U rack with accessories (HCL/D-Link)
66Supply, fitting & fixingof Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
67Supplying with fitting and fixing Surge protector of max operating voltage 350V at 400V network for maximum discharge current 40KA, with operator indicator and draw out cartridge of Schneider or equivalentmake), of the following ways complete with making necessary connection as approved, specified and directed by the deptt. Surge protection Max operating voltage 350Vintegrated type3P + N
68Supplying with fitting & fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connectionss as per direction of deptt.
69Supplying with fitting & fixing of 6 Amp one way modular clip in bell push MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/PLUS), ABB (CHEIRON), KOLORS (KRESP), SCHNEIDER (VIVACE), CRABTREE including making necessary connectionss as per direction of deptt.
70Supplying with fitting & fixing of following moulded PVC boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/PLUS), ABB (CHEIRON), KOLORS (KRESP), SCHNEIDER (VIVACE), CRABTREE in surface system complete as per direction of deptt. 1-3 module surface moulded PVC boxex
718 module surface moulded PVC boxex
7212 module horizantal surface moulded PVC boxex
73Supply, installation, testing & commissioning of Distributaion box 20 pairs with Krones (SIEMENS or equivalent s approved by the deptt.)
74Supply, installation, testing & commissioning ofUROSET 2005 Analog Hand set (SIEMENS or equivalent s approved by the deptt.)
75Supply, installation, testing & commissioning of 2 pair Unarmoured Telephone cable through existing conduit in surface/recess system.
76Supplying ,installation, testing & commissioning of 20 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system.
77Supplying with fitting & fixing of RJ-11 Telephone jack, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connectionss as per direction of deptt.
78Supplying and fitting fixing of Hi-Path 1150M Digital Communication System equipped with the following: 2 P&T Ports - 10 Extension Ports (upgradeable up to 34 extensions)Auto Call Back, Built-in FAX/DID Built in Voice Guided Direct inward Dialling 3 party Conference In-built Caller ID 100% Non- Block( SIEMENSor equivalent as approved by the Deptt.)
79Supplying ,installation, testing & commissioning of Dedicated EPABX Earthing for trouble free operation( SIEMENSor equivalent as approved by the Deptt.)
80Supply, installation, testing and commissioning of SITC of Network TDN IR Indoor Dome Camera 2 Mega Pixel 3.6mm Fixed Lens, Inbuilt audio, 24 IR LED"s for Night Vision, PoE, H.265 (Honeywell/ Panasonic)
81Supply, installation, testing and commissioning of SITC of Network TDN IR Outdoor Bullet Camera 2 Mega Pixel 3.6mm to 12 mm very focal Lens, IR LEDs for 30mtrs. Night Vision, PoE, H.265(Honeywell/ Panasonic)
82Supply, installation, testing and commissioning of 16 Channel Network Video Recorder, 2 SATA HDD Slot(Max 8TB), Real Time recording Resolution, Real time Local Playback , Multiplex operation, H.264 High profile, BNC/VGA/HDMI output, Main Profile baseline, HDD redundancy, Free DDNS, Network backup, USB HDD, USB Writer, SATA Writer, 1 RS485, support 18 kinds of PTZ protocols, ONVIF 2.0
83Supply with Fitting and fixing of SAITC of 6TB Surveillance Hard Disc Drive (SEGATE/ WD)
84Supply with fitting, fixing of SITC 8 port Gigabit Power Over Ethernet 8* RJ45 Switch 10/100M (D-Link/ Hikvision)
85Supplying installation testing and commissioning of 22" LCD TFT Screen (SAMSUNG / ball / LG / MITASHImake)
86Supplying installation testing and commissioning of UPS 1 KVA for Back Up (ball / ELNOVA / APCmake)
87Supplying installation testing of UTP CAT6 without PVC conduit
88Supplying including installation, testing and commissioning ofAir/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f.(la mounted on a1)M.S. Fabricated base frame.,2)M.S. fuel tank of required capacity.,3)Residual Silencer.,4) Standard Control Panel.5)Suitable batteries with lead.,5) First fill of lubeoil.,6)Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KVA) Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer alternator. KVA- PHASE- Approx size- Approx Wt-COOLING 62.5 3 3980x1240x1680 1920 Kg A/C
89Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 armoured U.G. cableU.G. cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 2 Core A2XWaY A2XFaY 6.00 Sq.mm 2 Core armoured U.G. cable
90Supplying and fixing 50 mm dia ISI marked hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) on surface including painting etc. as required:
91Supplying including installation, testing and commissioning of Solar power plant as per following specification and as directed by the Department. 5.12 KWp STANDALONE SOLAR POWER PLANT Load: 4000 Watts for 4 Hrs/Day Back up Or, Load: 2000 Watts for 8 Hrs/Day Back upCrystalline Solar PV Module - TBP1280M/ TBP1280 with RDSO Part-I Approval (as per IRS S: 84/92 or latest Amdt.) & IEC: 61215 Certification. 64 nos3 4 Module mounting structure with theft proof frame 16 nos4 Array Junction Box (AJ 2 nos 5 Main Junction Box (MJ 1 no 6 Power Conditioning Unit (PCU) – 96V DC- 5KVA- 230V AC, 50Hz 1 no 7 Battery Bank- Tubular Plate LMLA Battery Bank of 96V, 400Ah @ C10 1 set8 2C X 2.5 Sq.mm. P.V.C Cu.cable 300 metres 9 2C X 6.0 Sq.mm. P.V.C Cu.cable 100 metres10 2C X 10 Sq.mm. P.V.C Cu.cable 30 metres11 1C X 25 Sq.mm. P.V.C Cu.cable 30 metres 12 1C X50 Sq.mm. P.V.C Cu.cable 15 metres 13 Earthing kit 6 nos14 Installation kit 1 set Note: All cable lengths are estimated. Extra cables, if any, shall be charged extra at actual. All cable Lengths are calculated from the Solar Array to input of the Power Conditioning Unit (PCU). Loads &Load cables are not included in the Bill of Materials. SUGGESTED UNIT PRICEUnit Cost Without Installation & Commissioning)
92Installation & Commissioning Charges
93Supplying including installation, testing and commissioning of Solar Street light as per following specification and as directed by the Department.15 W LED SOLAR STREET LIGHT [Confirming RDSO Specification No: RDSO/PE/SPEC/PS/0093-2008(Rev 0)] SYSTEM SPECIFICATION 15 W LED based luminaries/fixture (1500 Lumens –typical) LED Type: White High Powered LED’s 5500-6500 K temperature. Automatic Dusk to Dawn Operate ion. Independent standalone Solar Street Lighting System. Powered by a 12V, 80 Wp Solar PV Module confirming RDSO Part-I Approval & IEC: 61215 Certification. (Model: TBP 1280/ 1280M). (make: TATA BP SOLAR or equivalent) 12V, 75Ah @ C10, Tubular Plate Lead Acid Low Maintenance Battery with PP Container (make: TATA BP SOLAR or equivalent). Battery Box made of M.S fabricated with corrosion resistance paint. 6m height MS Pole with corrosion resistance paint. Manufacturers Criteria: Must have ISO: 9001 & ISO: 14001 Certification. (As per Annexure A: Clause no: b, Page 10) Must have integrated production capacity of Solar PV Cell & Module. (As per Annexure A: Clause no: d, Page: 10) SUGGESTED UNIT PRICE
94Installation & Commissioning Charges
95Supplying and erection PSC pole 9.75 metre long, the pole is to be erection in 1:3:6 plain cement concrete foundation of size 1.50 m x 0.45 m x 0.45m having P.C.C base foundation 15 cm x 60 cm x 60cm including edge brick soiling and plastering above G.L. portion (0.30 metrecomplete with excavation of earth, handling of Surplus Soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department.
96Supplying and fitting fixing pole clamp complete as required and as directed by the department.
97Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular polemanufacturing out from electrically welded in 3 (threesection having a base plate including providing all required building materials as directed and specified by the deptt. (BANSAL/SRP / Valmont / PARUTHI ENGRmake) 410 SP 66 Length of pole = 12.00 metre., Length of sections,Bottom = 5.80 M, Middle = 3.10 M, Top = 3.10 M, Out side dia. & Thickness Bottom = 219.10 x 5.60 mm, Middle =193.7 x 4.85 mm, Top =165.10 x 4.50 mm
98Supplying and string up AAAC Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department.
99Supplying and fitting fixing of 11 KV T Cross arm complete with clamps ,blots, nuts etc. as required andas directed by the department.
100Supplying installation testing and commissioning of the following rating copper wound indoor/out door type transformer complete including the payment to be made to power supply authority for supervision charge,labour charge,cost of L.T/H.T. metering etc.(excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the deptt. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 Star,above 200 KVA as per CEA guidelines for losses along with LV enclosure.100 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
101Supplying and fitting fixing of Galvanised channel of 100mm X 65mm x 2200mm Long complete with clamps,blots,nuts etc as required and as directed by the dep"t.
102Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories completee as required and as directed by the dep"t.
103Supplying and fixing of 11 KV 5 KA Lighting arrestor(Poly) set completee as required and as directed by the dep"t.
104Supplying and fixing of 11 KV150 AD.O. fuse set completee as required and as directed by the dep"t.
105Supplying and erection of 11 KV Pin insulator (Poly)with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
106Supplying and erection of H.T. stay set complete (Galvanized) with 19 mm dia x 1.8 m long stay rod, anchor plate of size 30 cm x 30 cm x 6.4 mm thimble sty clamps tube buckle (19 mm x 60 cm)7/3.15mm dia G.I. stayand strain insulation etc. in cement concrete 1:3:6 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the deptt.
107Supplying including installation of 4" dia C.I. earth pipe complete as required and as directed by the dep"t.
108Extra for using salt (5 Kand Charcoal (64 Kin pipeEarth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
109Supplying including installation of 11 KV Ct/Pt combine metering system complete asrequired and as directed by the dep"t.
110Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the dep"t.
1113 Phase 4 4ire ICS DLMS complaint HT Trivector energy meter (category-A)
112LT XLPE cable 50 sq mm (1 core armour)
113SUPPLYING FITTING AND FIXING OF(DOWELLS/ COMETmake) ALUMINIUM tube terminal. ALUMINIUM tube terminal. Size: 70
114Steel Metering Cabinate
115L.T.C.T. 100/5 Amp
116Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 laid in air or through existing cable trench/duct/ cable tray/ HDPE pipeincluding fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .Core - 1, A2XWY 4x35 Sq.mm single core armoured cable
117DTR Fencing as per REC standard specification complete with material and labour
118Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured, extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1)1988, laid in air or through existing cable trench/duct/ cable tray/ HDPE pipeincluding fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . CONTROL cable Unarmoured 2XY2.5 sq mm 12 core Unarmoured
119Civil Work- Construction of Generator Shed
120Electric Load Security, Meter Security, Court agreement fees, inspection fees etc for all the necessary proceddings for comissioning of the Substation
121Maintenance Lagacy for 3 (three) Years1st Year Free2nd Year Ground Floor :
1221st Floor :
1233rd Year Ground Floor :
1243rd Year1st Floor :
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail