Repair Maintenance Of Internal Electrification Fitting Fixtures At Sangli , Lodhi Camp And New Echs Polyclinic Area Under Ge New Delhi, NEW DELHI-Delhi

Military Engineer Services-MES has published Repair Maintenance Of Internal Electrification Fitting Fixtures At Sangli , Lodhi Camp And New Echs Polyclinic Area Under Ge New Delhi. Submission Date for this Tender is 20-07-2021. Electrification Work Tenders in NEW DELHI Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

28276246
Corrigendum : Repair Maintenance Of Internal Electrification Fitting Fixtures At Sangli , Lodhi Camp And New Echs Polyclinic Area Under Ge New Delhi
Open Tender
Indian
Delhi
NEW DELHI
20-07-2021

Tender Details

Repair Maintenance Of Internal Electrification Fitting Fixtures At Sangli , Lodhi Camp And New Echs Polyclinic Area Under Ge New Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-07-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION FITTING/FIXTURES AT SANGLI, LODHI CAMP AND NEW ECHS POLYCLINIC AREA UNDER GE NEW DELHI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down copper/aluminium point wiring (fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, Light fitting, etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. 635 Per Point
2 2 M&L for point wiring with PVC FRLS insulated unsheathed multi-stranded copper conductor of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi-stranded copper conductor of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in conduits and its all accessories, including replacement of factory made steel boxes suitable for modular switch/sockets including modular plates of suitable size as per site requirement for the following items as mentioned in item no. 2.01 to 2.04 here-in-after.\nNote:Cutting & chasing, if required, shall be measured/paid under relevant items.\n
3 2.01 One light/ceiling fan/exhaust fan point controlled by one number one way switch 5 amps. 130 Per Point
4 2.02 One bell / buzzer point controlled by one bell push 10 Per Point
5 2.03 One 3 pin 5 Amps socket outlet point controlled by one number one way switch on independent board. 90 Per Point
6 2.04 One 3 pin 5 Amps socket outlet point controlled by one number one way switch on same board. 70 Per Point
7 3 All as per item No 2.00 here-in-before but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board as specified and directed by Engineer-in-Charge. 75 Per Point
8 4 M&L for point wiring with PVC insulated unsheathed multi-stranded copper conductor of size 1.5 Sqmm 1100 Volt grade including one run of PVC insulated unsheathed multi-stranded copper conductor of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC conduit of suitable sizes of medium grade ISI marked for surface wiring and its accessories, including MS sunken box and hylem sheet of suitable size, ISI marked for housing the switches and sockets for the following items as mentioned in item no. 4.01 to 4.03 here-in-after.\nNote:Cutting & chasing, if required, shall be measured/paid under relevant items and making good surface for disturbed area.\nNote:- On ceiling wiring shall be done in existing conduit.
9 4.01 One light/fan/exhaust fan point controlled by one no., 5 Amp one way switch. 120 Per Point
10 4.02 One three pin 5 Amp socket outlet point controlled by one no., one way switch on independent board 50 Per Point
11 4.03 One three pin 5 Amp socket outlet point controlled by one no., one way switch on same board 40 Per Point
12 5 All as per item No. 4.00 here-in-before but with 2.5 sqmm (for phase, neutral) and 2.5 sqmm (for continuous earth wire) cable for one 15/16 amp socket outlet point on independent board. 50 Per Point
13 6 M&L in cutting, making of hole in any type of wall, suitable for fixing in exhaust fan size upto 250mm including making of good surfaces to wall and disturbed area compete all as directed by Engr-in-Charge. 56 Each Job
14 7 Taking down of submain wiring including taking out conduit pipe of any description and of any size complete all as specified and directed by Engineer-in-charge 2400 RM
15 8 S&F submain wiring alongwith earth wire with 2 run of 4 Sqmm (Main Cable and neutral) and one run of 4 Sqmm as earth wire of FRLS PVC insulated copper conductor, single core cable drawn through and including rigid PVC conduit of 20 mm dia bore with all fittings accessories complete all as specified and directed by Engineer-in-charge.\nNote : 2 run of main cable, one run of earth wire and one run length of PVC conduit of suitable bore shall be considered as one run all as specified. 900 RM
16 9 S&F submain wiring alongwith earth wire with 2 run of 6 Sqmm (Main Cable and neutral) and one run of 6 Sqmm as earth wire of FRLS PVC insulated copper conductor, single core cable drawn through and including rigid PVC conduit of 20 mm bore with all fittings accessories complete all as specified and directed by Engineer-in-charge.\nNote : 2 run of main cable, one run of earth wire and one run length of PVC conduit of suitable bore shall be considered as one run all as specified. 850 RM
17 10 S&F submain wiring alongwith earth wire with 2 run of 10 Sqmm (Main Cable and neutral) and one run of 10 Sqmm as earth wire of FRLS PVC insulated copper conductor, single core cable drawn through and including rigid PVC conduit of 20 mm bore with all fittings accessories complete all as specified and directed by Engineer-in-charge.\nNote : 2 run of main cable, one run of earth wire and one run length of PVC conduit of suitable bore shall be considered as one run all as specified. 650 RM
18 11 S&F Modular switch 6 amps 250 V AC one way with ISI mark including 6 amps switch frame all as specified and directed by Engr - in - Charge 150 Each
19 12 S&F modular switch 16 A SP one way 240 volts with ISI mark all as specified and directed by Engr - in - Charge 75 Each
20 13 S&F modular socket 6 A Multi socket for 2 pin and 3 pin 240 volts with ISI mark all as specified and directed by Engr - in - Charge 100 Each
21 14 S&F modular socket outlet 16 A-2/3 pin combined 240 volts with ISI mark all as specified and directed by Engr - in - Charge 80 Each
22 15 S&F modular bell push 6A with Neon 1 module 240 volts with ISI mark all as specified and directed by Engr - in - Charge 10 Each
23 16 S&F switch piano flush button single pole one way 6 amps all as specified and directed by Engr - in - Charge 300 Each
24 17 S&F switch piano flush type 15 amps single pole one way all as specified and directed by Engr - in - Charge 80 Each
25 18 S&F socket outlet 5/6 amps 2 in 1, 3 pin flush type all as specified and directed by Engr - in - Charge 70 Each
26 19 S&F socket outlet 2 in 1, 3 pin 5 and 15 amp, flush type all as specified and directed by Engr - in - Charge 60 Each
27 20 S&F in replacement ceiling rose, 3 phase/ PVC/ polycarbonate isolated body all as specified and directed by Engr - in - Charge 150 Each
28 21 S&F in replacement electronic fan regulator modular type 120 Watt step type Double Modular as per existing all as specified. 50 Each
29 22 S&F in replacement DIMMER/ STEP type electronic fan regulator flush type 230 volts all as specified. 100 Each
30 23 S&Fin replacement electric bell Ding-Dong AC 230 Volt complete all as specified and directed by Engr - in - Charge all as specified. 40 Each
31 24 Taking down DB of SPN 4/8/12 way type removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. 23 Each
32 25 S&F sheet metal enclosures for DBs when MCB to be used,SPN double door 240 volt, 12 way with 200 amps rated bus bar. all as specified. 8 Each
33 26 S&F sheet metal enclosures for DBs when MCB to be used, SPN double door 240 volt, 8 way with 200 amps rated bus bar. all as specified. 7 Each
34 27 S&F sheet metal enclosures for DBs when MCB to be used, SPN double door 240 volt, 4 way with 200 amps rated bus bar all as specified and directed by Engr - in - Charge all as specified. 8 Each
35 28 Taking down MCCB/MCB type removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc. 312 Each
36 29 S&F MCB TPN 40 to 63 Amps, 415 V complete all as specified and directed by Engineer-in-charge 18 Each
37 30 S&F MCB SPN 40 to 63 Amp 240 volt 10 KA all as specified. 40 Each
38 31 S&F MCB SPN 32 Amp 240 volt 10 KA all as specified. 30 Each
39 32 S&F MCB SP 40 Amp to 63 Amp 10 KA.240 volts all as specified. 110 Each
40 33 S&F MCB SP 6 Amp to 32 Amp 10 KA.240 volts all as specified. 100 Each
41 34 S&F in replacement Metal clad enclosure with one MCB single pole, 20 Amps 240 volts all as specified. 40 Each
42 35 S&F in replacement Metal clad enclosure with one MCB single pole, 32 Amps 240 volts all as specified. 25 Each
43 36 S&F in replacement Modular plug & Sockets Distribution Board with one MCB single pole, 32 Amps 240 volts. all as specified. 45 Each
44 37 Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge. 120 Each
45 38 Supply and fixing in replacement LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge. 100 Each
46 39 Supply and fix in replacement only decorative laminated sheet 3mm thick of size 8'' X 12'' including necessary cutting of sheet for fixing switch / socket complete as specified and directed. 10 Each
47 40 Supply and fix in replacement only decorative laminated sheet 3mm thick of size 8'' X 5'' including necessary cutting of sheet for fixing switch / socket complete as specified and directed. 10 Each
48 41 Supply and fix in replacement only decorative laminated sheet 3mm thick of size 7'' X 4'' including necessary cutting of sheet for fixing switch / socket complete as specified and directed. 10 Each
49 42 Supply and fix only fan capacitor of the following capacity:-
50 42.01 1.5 Mfd 60 Each
51 42.02 2.5 Mfd 100 Each
52 42.03 3.15 Mfd 50 Each
53 43 Supply and fix in replacement only non metallic rigid PVC conduit medium grade 20 mm dia, ISI Mark complete all as specified and directed. 65 RM
54 44 Taking down of ceiling fan/ exhaust fan dismantling of blades, transportation to workshop and carrying out for rewinding, transportation to site, reinstallation and testing complete. 320 Each
55 45 M&L for Rewinding of ceiling fan 1200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provision of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required complete all as specified and directed by Engineer-in-charge. 200 Each job
56 46 All as per item No 45.00 here-in-before but exhaust fan 230/300 mm sweep 100 Each
57 47 All as per item No 45.00 here-in-before but exhaust fan 400 mm sweep 20 Each
58 48 S&F ceiling fan Ball bearing of suitable size & model (as per sample). 200 Each
59 49 M&L for replacing 'U' clamps with rubber reel, bolts, nuts, washers and safety pin ceiling fan of any size 50 Each
60 50 M&L for Down rod of 1' height fabricated out of MS pipe 12mm dia heavy duty duly painted with one coat of white paint complete. 50 Each
61 51 S&F of Canopy of Ceiling fans of 1200/1400mm swipe size heavy duty duly painted with one coat of white paint complete. 25 Each
62 52 M&L for spray painting (white colour) with synthetic enamel paint to Ceiling fans/Exhaust fan of any capacity to reach upto satisfied finish of painting after cleaning and preparation of surface and marking MES No with black paint complete all as specified and directed by Engineer-in-charge. 98 Each
63 53 Taking down carefully Geysers 25/50 Ltr capacity, opening for inspection, cleaning, descaling, reassembling and refixing in position after carrying out repairs like soldering/ brazing etc including replacement of pressed rubber gasket, Nuts, bolts, neon indicator lamp 1 Amp etc.\nNote -U/S items to be paid separately under relevant items. 65 Each job
64 54 M&L for spray painting (white colour) with synthetic enamel paint to Geysers 25/50 Liters capacity to reach upto satisfied finish of painting after cleaning and preparation of surface and marking MES No. with black paint complete all as specified and directed by Engineer-in-charge. 25 Each
65 55 M&L for heating element of 2.0 kW (Circular) as required at site including rubber washers (ISI marked) etc complete all as specified and directed (As per sample). 20 Each
66 56 M&L for heating element of 2.0 KW (Rectangle) as required at site including rubber washers (ISI marked) etc complete all as specified and directed. 50 Each
67 57 S&F in repairs storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) for 50 litre capacity geysers with collar complete duly tested at required pressure as per IT I of 1986 of steel storage tank. 15 Each
68 58 S&F in repairs storage tank made out of copper sheet of appropriate thickness and confirming to IS 208 (1974) for 25 litre capacity geysers with collar complete duly tested at required pressure as per IT I of 1986 of steel storage tank. 20 Each
69 59 M&L for replacement of insulating material (Glass wool) for 25/ 50 litre capacity Geysers all as directed by Engineer -in - charge. 25 Each
70 60 S&F in repair base plate assembly 20 SWG heavy duty suitable for 50 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample). 10 Each
71 61 S&F in repairs base plate assembly 20 SWG heavy duty suitable for 25 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample). 20 Each
72 62 M&L in replacement for chromium plated copper connection pipe 600mm long with two brass adopters washers and connecting up complete all as specified and directed. 60 Each
73 63 M&L in replacement for PVC connection pipe 450mm long with two brass adopters washers and connecting up complete ISI mark all as specified and directed by Engr-in Charge 40 Each
74 64 M&L in replacement safety nut for high pressure release (As per sample). 20 Each
75 65 S&F in replacement non return valves 15mm dia and connecting up complete (ISI marked) as per sample 20 Each
76 66 M&L in replacement top cover for geysers of 25/50 ltrs capacity as required at site duly painted with two coats of Synthetic enamel spray paint (first quality) all as directed. 20 Each
77 67 S&F in replacement bottom cover for geysers of 25/50 ltr required at site duly painted with synthetic enamel spray paint (first quality) with inspection plate in two pieces all as specified and directed. 20 Each
78 68 S&F in replacement of outer cover for geyser made out of MS sheet suitable for 50 ltrs capacity geyser vertical/horizontal type all as specified and directed. 10 Each
79 69 S&F in replacement of outer cover for geyser made out of MS sheet suitable for 25 ltrs capacity geyser vertical/horizontal type all as specified and directed. 15 Each
80 70 S&F in replacement thermostat (ISI Marked) for 25/50 Liters capacity Geyser. 85 Each
81 71 S&F in replacement indicator lamp (Red & Green) 230 volts suitable for Geyser (as per sample) 40 Each
82 72 Supply and fix in replacement mild steel hole fastener 10mm dia, 100mm long including nut and washer. 50 Each
83 73 Supply and Fix in replacement gun metal gate valve 15 mm bore, ISI marked with iron wheel head, screwed both ends for GI pipe complete. 45 Each
84 74 S&F in replacement 9 watt LED Bulb suitable for thread type holder/ B-22 type holder complete all as specified and directed by Engineer-in-charge. 25 Each
85 75 S&F in replacement 15 watt LED Bulb suitable for thread type holder/ B-22 type holder complete all as specified and directed by Engineer-in-charge. 25 Each
86 76 S&F in replacement Ceiling fan blade suitable for 1200mm sweep as per site requirement complete all as specified and directed by Engineer-in-charge. 50 Set of Three
87 77 S&F in replacement Exhaust fan blade suitable for 300mm/450mm sweep as per site requirement complete all as specified and directed by Engineer-in-charge. 30 Set of Four
88 78 Supply & Fixing in replacement light freedom building security light compressing pressure, die cast housing for better aesthetics and thermal management, comprises of extruded aluminium housing with pre-wired gear tray with LEDs & drive, heat resistant flat glass suitable gasketed for IP65 protection, high grade power coating and fitted with toughened glass with high power LEDs of 40 watt and pipe mounting arrangement for end mounting on bracket made out of 50mm dia GI pipe light grade, 1.2m long bent to shape with two sets of clamps made out of flat iron 50 x 6mm, bolts, nuts and washers and applying two coats of aluminium paint over on coat of red oxide zinc chrome primer connecting electrically with PVC multi-stranded copper cable of suitable size complete including taking down existing 40 watt SV/MH lamp fittings all as specified and directed \nMake - CG freedom+ Cat pt no - LSTS-40-CDL or equivalent in Havells, philips.\n 15 Each
89 79 Supply & Fixing in replacement light freedom building security light compressing pressure, die cast housing for better aesthetics and thermal management. Comprises of extruded aluminium housing with pre-wired gear tray with LED’s & drive, heat resistant flat glass suitable gasketed for IP65 protection, high grade power coating and fitted with toughened glass with high power LED’s of 30 watt and pipe mounting arrangement for end mounting on bracket made out of 50mm dia GI pipe light grade, 1.2m long bent to shape with two sets of clamps made out of flat iron 50 x 6mm, bolts, nuts and washers and applying two coats of aluminium paint over on coat of red oxide zinc chrome primer connecting electrically with PVC multi-stranded copper cable of suitable size complete including taking down existing 30 watt SV/MH lamp fittings all as specified and directed.\nMake - CG freedom+ Cat pt no - LSTS-30-CDL or equivalent in Havells, philips.\n 10 Each
90 80 Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 80 Each
91 81 S&F MCCB DB VTPN Vertical load line 4 way double door IP 54 "IK 09 cat no 507750 of Legrand or equivalent Make of L&T or C&S 4 Each
92 82 Supply and fixing MCCB, 4 pole, 415 volt of capacity 63 Amp, breaking capacity 25 KA , Icu=100% Ics thermal magnetic type adjustable type 80 to 100 % confirming to IEC-60947-II, IS-13947-II , including thimbles, nuts, bolts ,washers etc and connections, etc. all as specified and directed by Engr-in-Charge Make : Legrand/Schnieder/L&T cat part No 420053 10 Each
93 83 M&L in replacement for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to galvanised iron strip 25x4mm as earthing lead lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 5 of SSR Pt-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete \n(NOTE:-GI earth strip 7.5m will be measured and paid separately) 6 Each
94 84 M&L in replacement For fixing earth continuity conductor or main earth lead fixed to wall or buried in ground or drawn in GI pipe with 25x4mm galvanised iron wire complete all as specified and directed. 90 RM
95 85 Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge.\nProduct Code LCCLB24-CDL of crompton Cute linea or equivalent in Havells/Philips 100 Each
96 86 S&F inverter LED Tube light batten of 5700K to 6500K , 10W ,rated voltage 230 V AC 50 Hz having high power high brightness LM 80 certified LED with PC /Aluminium extrusion Milky diffuser front cover ,lumen maintenance of 50000 hours @ L70 li ion BIS certified battery of 3.7V 10W at battery operation ,back up will be 3-4 hrs, protection will be IP 20,overcharging, deep discharging, thermal compensation, marked with standard IS 10322, LM79 complete all as specified. 100 Each
97 87 S&F in replacement LED Tube light batten of 5700K to 6500K , 18W ,rated voltage 230 V AC 50 Hz having high power high brightness LM 80 certified LED with PC /Aluminium extrusion Milky diffuser front cover ,lumen maintenance of 50000 hours @ L70 li ion BIS certified battery of 3.7V 10W at battery operation ,back up will be 3-4 hrs, protection will be IP 20,overcharging ,deep discharging ,thermal compensation, marked with standard IS 10322,LM79 complete all as specified.\nMake : CG cat part no LCTL18-CDL or equivalent in philips/Havells 250 Each
98 88 S&F aesthetically designed surface mounted circular shaped decorative wall/ceiling LED light of 12 W fixture with opal diffuser to give glare free light including suitable LED lamp of 12 W having dimenstion dia of 300mm. AND height 92 mm \nMake: CG cat No-LCSR-12-CDL or equivalent of Phillips/Havells 15 Each
99 89 S&F bronze coloured floral brown glass metal aesthetically designed Wall mounted decorative wall LED light of 8/9 W fixture with opal diffuser to give glare free light including suitable LED inverter lamp of 8/9 W having Lamp base E27/B22 (colour-Natural white/cool day/Warm White).\nMake: Philips cat No-37934/06 or equivalent in CG/Halonix 56 Each
100 90 Supply and fix Wall Mounted indoor type factory made load line DBs double door made out of CRCA mild steel sheet with insulating material like polyester powder coated surface mounted 12 way VTPN 415 volts IP 43 protection with suitable bus bar neutral link and earth link suitable for 4 pole MCCB of 250 A (with display electronic release microprocessor based having short circuit and overload protection) 36KA as incomer & MCB SP 40 A 6-nos and 63 A 6-nos as outgoing complete all as specified.\nNote: The rate of MCCB and MCB should be included in the quoted rate.\n 3 Each
101 91 S&F aesthetically designed Wall mounted decorative LED bed light of 4 W fixture with opal diffuser to give glare free light including suitable LED lamp of 4 W having Lamp base E27.\nMake: Philips cat No-56240/31 or Equivalent in CG/Havells 25 Each
102 92 S&F of inverter security light fitting 60W with aluminium pdc top maintainable clear toughened glass suitable high efficient secondary lense LM80 certified LED with 50000 hr @ L70 along with isolated electronic CC driver RTC enable with insulated copper wire covered with SS & MS zing plated and passivated. The light should be IP66 ingress protection and IK05 impact resistance li-ion BIS certified battery of 3.7V 10W at battery operation ,back up will be 3-4 hrs, protection will be IP 20,overcharging ,deep discharging ,thermal compensation, marked with standard IS 10322,LM79 complete all as specified. 20 Each
103 93 Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified.\nMake:CG cat no-LCTLSN-36-CDL or Equivalent in philips/Havells 30 Each
104 94 S&F in replacement inverter bulk head light of 5700K to 6500K , 10W ,rated voltage 230 V AC 50 Hz having high power high brightness LM 80 certified LED with PC /Aluminium extrusion Milky diffuser front cover ,lumen maintenance of 50000 hours @ L70 li ion BIS certified battery of 3.7V 10W at battery operation ,back up will be 3-4 hrs, protection will be IP 20,overcharging ,deep discharging, thermal compensation, marked with standard IS 10322,LM79 complete all as specified. 30 Each