Mussoorie Dehradun Development Authority has published Construction Of Community Hall At Inderapuram First Floor. Submission Date for this Tender is 02-07-2021. Building Work Tenders in DEHRADUN Uttarakhand. Bidders can get complete Tender details and download the document.
Name of Work: CONSTRUCTION OF COMMUNITY HALL AT INDERAPURAM FIRST FLOOR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 733.70 | BI01010001010000000000000515BI0100001113 | 120.6 | Sqm |
2 | 2 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and\ncantilevers sqm 552.05 | BI01010001010000000000000515BI0100001114 | 215.7 | Sqm |
3 | 3 | 5.9.3 Suspended floors, roofs, landings, balconies and access platform sqm 693.05 | BI01010001010000000000000515BI0100001115 | 246.62 | Sqm |
4 | 4 | 5.33 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).5.33.2 All works above plinth level upto floor V level cum 9400.85 | BI01010001010000000000000515BI0100001116 | 89.31 | Cum |
5 | 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars | BI01010001010000000000000515BI0100001117 | 16124.9 | KG |
6 | 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001118 | 30.24 | Cum |
7 | 7 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved\nsteel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001119 | 2175.6 | KG |
8 | 8 | 7029 Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm sqm 250.00 | BI01010001010000000000000515BI0100001120 | 26.25 | Sqm |
9 | 9 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) -decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws | BI01010001010000000000000515BI0100001121 | 1.89 | Sqm |
10 | 10 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes\n10.30.1 | BI01010001010000000000000515BI0100001122 | 26.25 | SQm |
11 | 11 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) | BI01010001010000000000000515BI0100001123 | 160.26 | Sqm |
12 | 12 | 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) | BI01010001010000000000000515BI0100001124 | 128.4 | Sqm |
13 | 13 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) | BI01010001010000000000000515BI0100001125 | 228 | Sqm |
14 | 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | BI01010001010000000000000515BI0100001126 | 416.4 | Sqm |
15 | 15 | Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm | BI01010001010000000000000515BI0100001127 | 416.4 | Sqm |
16 | 16 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm | BI01010001010000000000000515BI0100001128 | 128.4 | Sqm |
17 | 17 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture | BI01010001010000000000000515BI0100001129 | 28.14 | Sqm |
18 | 18 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture | BI01010001010000000000000515BI0100001130 | 1.89 | Sqm |
19 | 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades,\nlaid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | BI01010001010000000000000515BI0100001131 | 234.3 | Sqm |
20 | 20 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.\n(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.\n(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge.\n(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm\nsquare 3 mm deep.\n(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum\nthickness at khurra as 65 mm. sqm 1398.50 | BI01010001010000000000000515BI0100001132 | 228 | Sqm |
21 | 21 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,12.41.2 110 mm diameter metre 305.05 | BI01010001010000000000000515BI0100001133 | 28 | rmt |
22 | 22 | 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler12.42.1.2 110 mm each 117.80 | BI01010001010000000000000515BI0100001134 | 4 | each |
23 | 23 | Shoe (Plain) 12.42.6.2 110 mm Shoe each 113.80 | BI01010001010000000000000515BI0100001135 | 4 | each |
24 | 24 | 12.38 Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :12.38.2 150 mm diameter each 307.50 | BI01010001010000000000000515BI0100001136 | 20 | each |
25 | 25 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete | BI01010001010000000000000515BI0100001137 | 1 | nos |
26 | 26 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm\n9.66.1 | BI01010001010000000000000515BI0100001138 | 68 | nos |
27 | 27 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.63.1 250x10 mm | BI01010001010000000000000515BI0100001139 | 134 | nos |
28 | 28 | Providing and fixing ISI marked, IS : 1341, M.S. heavy weight butt hinges with necessary screws etc. complete : 125x90x4.00 mm | BI01010001010000000000000515BI0100001140 | 135 | nos |
29 | 29 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. | BI01010001010000000000000515BI0100001141 | 2 | nos |
30 | 30 | ELECTRIFICATION WORK Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required Group C | BI01010001010000000000000515BI0100001143 | 113 | POINT |
31 | 31 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium.class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | BI01010001010000000000000515BI0100001144 | 70 | MTR |
32 | 32 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | BI01010001010000000000000515BI0100001145 | 30 | MTR |
33 | 33 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | BI01010001010000000000000515BI0100001146 | 110 | MTR |
34 | 34 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | BI01010001010000000000000515BI0100001147 | 32 | nos |
35 | 35 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required 180 mm X 100 mm X 60 mm deep | BI01010001010000000000000515BI0100001148 | 2 | EACH |
36 | 36 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | BI01010001010000000000000515BI0100001149 | 10 | EACH |
37 | 37 | 3 pin 5/6 amps Socket | BI01010001010000000000000515BI0100001150 | 10 | EACH |
38 | 38 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required | BI01010001010000000000000515BI0100001151 | 20 | EACH |
39 | 39 | Supplying and flxing modular blanking plate on the existing modular plate & switch box excluding modular plate as required | BI01010001010000000000000515BI0100001152 | 17 | EACH |
40 | 40 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | BI01010001010000000000000515BI0100001153 | 10 | EACH |
41 | 41 | Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required | BI01010001010000000000000515BI0100001154 | 3 | EACH |
42 | 42 | Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required | BI01010001010000000000000515BI0100001155 | 13 | EACH |
43 | 43 | Supplying and flxing brass batten/angle holder including connection etc. as required. | BI01010001010000000000000515BI0100001156 | 10 | EACH |
44 | 44 | Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required. | BI01010001010000000000000515BI0100001157 | 65 | EACH |
45 | 45 | Installation, testing and commissioning of pre-wired,fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | BI01010001010000000000000515BI0100001158 | 10 | EACH |
46 | 46 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required | BI01010001010000000000000515BI0100001159 | 25 | EACH |
47 | 47 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10cm and 5 cm or less shall be ignored) | BI01010001010000000000000515BI0100001160 | 25 | EACH |
48 | 48 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep | BI01010001010000000000000515BI0100001161 | 10 | EACH |
49 | 49 | Extra for fixing louvers/shutters complete with frame for a exhaust fan of all sizes. | BI01010001010000000000000515BI0100001162 | 10 | EACH |
50 | 50 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door | BI01010001010000000000000515BI0100001163 | 1 | EACH |
51 | 51 | Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'c' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole | BI01010001010000000000000515BI0100001164 | 10 | EACH |
52 | 52 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A | BI01010001010000000000000515BI0100001165 | 1 | EACH |
53 | 53 | Supply and fixing of LED lamp 7 w , 230/250 Volts, 50 Hz etc. complete . required. | BI01010001010000000000000515BI0100001166 | 10 | EACH |
54 | 54 | Supply of Ceiling fan 1200mm sweep, 240V, ball bearing and 5 star rating as approved by Engineer in charge complete in all respect. | BI01010001010000000000000515BI0100001167 | 25 | EACH |
55 | 55 | Supply of Exhaust fan 300mm , 240V, as approved by Engineer in charge complete in all respect. | BI01010001010000000000000515BI0100001168 | 10 | EACH |
56 | 56 | Supply of LED Tube Light with batten suitable for up to 1 X 20 watt LED tube light fitting including tube on Surface complete in all respect. | BI01010001010000000000000515BI0100001169 | 10 | EACH |
57 | 57 | Supply of Aesthetically designed, decorative recess mounted 5 W, LED (Round) spot lighte complete in all respect. | BI01010001010000000000000515BI0100001170 | 65 | EACH |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy