}

Supply Of Consumables/Non-Consumables For The Department Of Surgical Oncology-Puducherry

Jawaharlal Institute Of Post Graduate Medical Education And Research-JIPMER has published Supply Of Consumables/Non-Consumables For The Department Of Surgical Oncology. Submission Date for this Tender is 17-07-2021. Coats and Jackets Tenders in Puducherry. Bidders can get complete Tender details and download the document.




Tender Notice

28265299
Supply Of Consumables/Non-Consumables For The Department Of Surgical Oncology
Open Tender
Indian
Puducherry
17-07-2021

Tender Details

Supply Of Consumables/Non-Consumables For The Department Of Surgical Oncology 1 Consumable Items 1.001 Endo cutter with Articulating shaft, length 34cm to accommodate 60mm, 45mm & 30mm reloads 1.002 Reload 60mm blue articulating (1.5mm) compatible with above stapler (item no 1) 1.003 Reload 60mm green articulating (2.0mm) compatible with above stapler (item no 1) 1.004 Reload 45mm Green articulating (2.0mm) compatible with above stapler (item no 1) 1.005 Reload 45mm blue articulating (1.5mm) compatible with above stapler (item no 1) 1.006 Reload 45mm white articulating (1.0mm) compatible with above stapler (item no 1) 1.007 Curved tip 30mm articulating vascular reload (1.0mm) compatible with above stapler (Item no 1) 1.008 35mm Standard Articulating Endoscopic Linear Cutter,* 320mm WITH BATTERY 1.009 White reload (1 mm) intended for use in vascular/thin tissue above stapler (item no 8 ) 1.01 Curved Linear Cutter (contour) 1.011 Green reload compatible with above curved linear stapler (Item no 10 ) 1.012 Battery operated circular stapler having disposable battery pack with Gripping Surface technology an 3D Stapling technology detachable anvil and adjustable closed staple height of 1.5 - 2.2 mm and open leg length of 5.2mm having staple housing outer diameter 31mm and two staple rows 1.013 Battery operated circular stapler having disposable battery pack with Gripping Surface technology an 3D Stapling technology detachable anvil and adjustable closed staple height of 1.5 - 2.2 mm and open leg length of 5.2mm having staple housing outer diameter 25mm and two staple rows 1.014 Circular Stapler 31mm with three staggered rows and Tri-Staple Technology Purple. Staple height 3.0mm, 3.5mm, 4.0mm 1.015 Stapler 3.5mm, 25mm for Trans oral anvil device 1.016 Trans oral anvil device, 25mm compatible with above stapler (Item No 15) 1.017 Blue Reload compatible with reusable linear cutter 60 mm with in build new knife blade and adjustable firing knob compatible with reusable stapler 1.018 Green Reload compatible with reusable linear cutter 60 mm with in build new knife blade and adjustable firing knob compatible with reusable stapler 1.019 Blue Reload compatible with reusable linear cutter 80 mm with in build new knife blade and adjustable firing knob compatible with reusable stapler 1.02 Green Reload compatible with reusable linear cutter 80 mm with in build new knife blade and adjustable firing knob compatible with reusable stapler 1.021 Twin Disposable Neutral Plate compatible with Alsa Excel MCD 350 series Electrosurgical Unit 1.022 Twin Disposable Neutral Plate compatible with Valley lab Electrosurgical Unit 1.023 Disposable monopolar electro surgery pencils compatible with Alsa Excel MCD 350 series Electrosurgical unit 1.024 Disposable cautery pencils (PTFE coated electrosurgical electrode) with blade tip & hand control - twin switch for cutting & coagulation mode controls compatible to all diathermy machines, or universal connector with shaft diameter preferably less than 2.5 mm. 1.025 Bipolar cable compatible with Alsa Excel MCD 350 series Electrosurgical unit 1.026 Bipolar cable compatible with Valley lab Electrosurgical unit 1.027 Electrocautery ball tip (2mm) with insulated shaft 12 -15cm 1.028 Electrocautery extension flap tip insulated 12 - 15 cm 1.029 Disposable Extended EDGE coated electrode with a length 16.51cm and active component 2.54cm compatible with any Electrosurgical Energy System Model 1.03 Disposable Extended EDGE coated electrode with a length 10.16cm and active component 2.54cm compatible with any Electrosurgical Energy System Model 1.031 Disposable Extended EDGE coated electrode with a length 7.63cm and active component 2.8cm compatible with any Electrosurgical Energy System Model 1.032 Thunderbeat shears 5mm, 35cm with pistol grip 1.033 Thunderbeat shear 5mm, 20cm with front actuated grip 1.034 Disposable Vessel sealing device Maryland tip 5 mm laparoscopic sealer/divider 37cm, cut length 18.3mm, seal length 20mm, compatible with Electrosurgical Energy System Model: LS10 1.035 Disposable Vessel sealing device Maryland tip 5 mm open sealer/divider 23cm, cut length 18.3mm, seal length 20mm, compatible with Electrosurgical Energy System Model: LS10 1.036 Disposable Vessel sealing device open sealer/divider 18 cm cut length 15.3mm, seal length 17.3mm, compatible with Electrosurgical Energy System Model: LS10 1.037 Vessel sealing hand instrument for open surgery with a total length of 21cm (8.1 inch’) with jaw angle of 40’ degree and seal plate length 20.6mm, cut length 19.8mm, distal seal width 2.03mm,proximal seal width 4.06mm and compatible to work with Covidien Advance energy platform Ls10 & Ft10 1.038 Disposable ultrasonic dissector with a shaft length of 13 -14 cm compatible with cordless ultrasonic dissection system. It should be hand activated with a dual energy button. 1.039 Disposable ultrasonic dissector with a shaft length of 24-26 cm compatible with cordless ultrasonic dissection system. It should be hand activated with a dual energy button. 1.04 Disposable ultrasonic dissector with a shaft length of 36 -39 cm compatible with cordless ultrasonic dissection system. It should be hand activated with a dual energy button. 1.041 Peripheral introduced central venous catheter Double Lumen 5-6 F with a minimum of 50 cm length 1.042 Titanium Single Lumen Port, Intermediate Tray with Attachable Distally Valved 8.0 - 9.6 Fr Catheter. Utilizes Percutaneous Introducer System 1.043 Indwelling Tracheo esophageal voice prosthesis with valve and introducer kit (pharyngeal protector and stylet) - 8mm diameter 1.044 Catheter drainage percutaneous pigtail type set, 14 FR with IP needle, connector and dilator set 1.045 Pigtail radiopaque soft polyurethane nephrostomy catheter 20cm long (excluding the length of coil) 10F disposable and presterilized carrying an international authentication of quality like CE, BIS or FDA approval 1.046 One piece colostomy bag 15-55mm 1.047 One piece urostomy bag with a base plate of 15-55mm and with a tap 1.048 Silicone Surgical Vessel Loop 36cm long 2.5x1.02 mm thick (red) 1.049 Silicone Surgical Vessel Loop 36cm long 2.5x1.02 mm thick (Blue) 1.05 Silicone Surgical Vessel Loop 36cm long 2.5x1.02 mm thick (yellow) 1.051 Elastomeric pump (5 day pump) Infusional Chemotherapy, Ambulatory Design – No Cords, Outlets, Batteries or IV Poles, Single-use disposable, Latex-Free, No programming required, eliminates rate manipulation. Flow rate should be adjustable. 1.052 Catheter Mount Standard size 1.053 Sterile Transparent film dressing 10x11.5 cm 1.054 Thromboembolic stockings with a graded pressure fit thigh length. Size - Medium 1.055 Thromboembolic stockings with a graded pressure fit thigh length. Size - Larger 1.056 Thigh length sleeve for sequential compressive device compatible with Kendall make - Size small 1.057 Thigh length sleeve for sequential compressive device compatible with Kendall make - Size medium 1.058 Knee length sleeve for sequential compressive device compatible with Kendall make - Size medium 1.059 Drape laparotomy, sterile, disposable - consists of re-inforced mayo stand cover 120cm/140cm, utility drape four pieces 75/50 cm, transverse drape 200/150 cm, head end curtain 200/150 cm, hole sheet 300/150 cm. 1.06 Ioban 30x30cm(polythene, transparent, beta dine coated) 1.061 Radio opaque, abdominal pad unsterile, size-15 cms x 15 cms (price to be quoted per pad) 1.062 Radio opaque, gauze, unsterile, size-10 cms x 10 cms (price to quoted per gauze) 1.063 Bulb for OT light compatible with Dr Lite model 2060-76 serial number K047-GC - (24v & 150W) 1.064 Bulb holders for OT light compatible with Dr Lite model 2060-76 serial number K047-GC - (24v & 150W) 1.065 Reusable Sleeves for OT handle compatible with Dr Lite model 2066-76 1.066 Disposable tubing set with heat exchanger compatible with HIPEC system. The tubing and connectors should be of medical grade, latex free, non toxic, pyrogen free, leak proof and disposable in nature. Should withhold a temperature of 60 degree centigrade. Flow rate should be a minimum of 3lit per minute. There should be inbuilt temperature sensors for inflow and outflow. The HIPEC machine should be provided by the manufacturers to use the consumables at no additional cost. The Cost should be quoted per patient (If two kits are required per patient then the price to be quoted together). 1.067 Skin marking pen with ruler in a sterile Each Piece 1.068 Stainless steel Gigli saw wires 1.069 Sterile Skin graft Blades 1.07 Titanium mesh 30 x 30 cm 1.071 Titanium mesh 15 x 15 cm 1.072 Stretch vascular graft PTFE of internal diameter 7mm and length 10cm 1.073 Stretch vascular graft PTFE of internal diameter 8mm and length 10cm 1.074 Stretch vascular graft PTFE of internal diameter 12mm and length 20cm 1.075 Stretch vascular graft PTFE of internal diameter 16mm and length 20cm 1.076 Stretch vascular graft PTFE of internal diameter 22mm and length 20cm 1.077 Indocyanine green dye for fluorescence angiography 1.078 Single use flexible bronchoscope - It should be Light Weight. It should have an Outer Diameter of 5.0mm and a working channel of 2.2mm. It should be compatible with a minimum ET tube size of 6mm. It should be compatible with a minimum DLT size of 41Fr. It should have a Bending Section of 150° Up & 130° Down. It should have a working length of approximately 600mm.It should consist of LED illumination and Camera at the Tip. It should have an Oxygen and Drug Delivery port at the control body. It should have a dedicated Suction Port. 1.079 Single use flexible bronchoscope - It should be Light Weight. It should have an Outer Diameter of 3.8mm and a working channel of 1.2mm. It should be compatible with a minimum ET tube size of 5mm. It should be compatible with a minimum DLT size of 37Fr. It should have a Bending Section of 130° Up & 130° Down. It should have a working length of approximately 600mm.It should consist of LED illumination and Camera at the Tip. It should have an Oxygen and Drug Delivery port at the control body. It should have a dedicated Suction Port. 1.08 Endobronchial blocker for one lung ventilation. The cuff be low pressure and high volume. The blocker should have a multiport, CPAP and a suction adapter and should be 9Fr with a length of 75 cm and above. Should be for sue with a endotracheal tube size of 7mm 1.081 Suction valve compatible with Richard Wolf fibber optic bronchoscope 1.082 Membrane for suction valves compatible with Richard Wolf fibber optic bronchoscope 1.083 Reciprocating saw blades - precision thin with a thickness of minimum .38mm and cutting edge of 22.5mm that fits the existing saw system (Stryker core u drill) in the department. The comparison shall be made only after demonstration of the product 1.084 Reciprocating saw blades - Thick blade with a thickness of minimum .63mm and cutting edge of 27mm that fits the existing saw system (Stryker core u drill) in the department. The comparison shall be made only after demonstration of the product 1.085 Reciprocating blades for core sagittal saw - Aggressive thin with a cutting depth of 39mm and cutting edge of 13mm. Should be 0.38 thick and be compatible with existing saw system (Stryker core u drill) in the department. The comparison shall be made only after demonstration of the product 1.086 Reciprocating blades for core oscillating saw - Aggressive thin with a cutting depth of 39mm and cutting edge of 13mm. Should be 0.38 thick and be compatible with existing saw system (Stryker core u drill) in the department. The comparison shall be made only after demonstration of the product 1.087 1.5 mm drill bit for core drill - The drill bit should be compatible with the existing saw system (Stryker core u drill) in the department. The comparison shall be made only after demonstration of the product 1.088 2 mm drill bit for core drill - The drill bit should be compatible with the existing saw system (Stryker core u drill) in the department. The comparison shall be made only after demonstration of the product 1.089 Specimen retrieval pouch bag, sterile and disposable, laparoscopic impervious, sizes-10mm, 4inchx6inch 1.09 Specimen retrieval pouch bag, sterile and disposable, laparoscopic impervious, sizes-15mm, 5inchx9inch 1.091 Wound protector small incision size 2-6.6cm 1.092 Wound protector medium incision Size 5-9cm 1.093 Wound protector Large incision Size 9-14cm 1.094 Trocar for obese Patients, Size 11 mm, color code: green-red, consisting of: 31103 P Trocar only, with pyramidal tip 31103 H1 Cannula without Valve, with insufflation stop-cock, length 15 cm 30103 M1 Multifunctional Valve, Size 11 mm 1.095 5mm bladeless disposable laparoscopic trocars 1.096 10mm bladeless disposable laparoscopic trocars 1.097 12 mm bladeless laparoscopic optical trocar 1.098 Sleeves for light cable & Camera cable 1.099 Titanium Liga Clips Large 6 Clips per Cartridge 1.1 Titanium Liga Clips Medium 6 Clips per Cartridge 1.101 Titanium Liga Clips small 6 Clips per Cartridge 1.102 Jackson Pratt Drainage set 1.103 Feeding bag for enteral feeds with roller control. 1.2 L capacity. Should be PVC free. 1.104 Dry Suction water seal chest drain kit. Should have water seal technology with air leak monitor for patient air leak testing. Negative suction should be adjustable between -10 to 40 cm of H2O 1.105 Titanium alloy 2.0 mm self tapping screws 6mm 1.106 Titanium alloy 2.0 mm self tapping screws 8mm 1.107 Titanium alloy 2.0 mm self tapping screws 10mm 1.108 Titanium alloy 2.3 mm self tapping Screw 8mm 1.109 Titanium alloy 2.3 mm self tapping Screw 10mm 1.11 Titanium alloy 2.3 mm self tapping Screw 12mm 1.111 Titanium Alloy 24 hole straight plate 2.0mm 1.112 Titanium Alloy 24 hole straight plate 2.3mm 1.113 Titanium alloy left side angled 24 hole plate 2.0 mm 1.114 Enteral nutritional feed (Should contain high quality and high quantity whey protein 42 g/100g, with 5% dietary fibre, Sugar free and low sodium content of 230mg/100g. Should provide a minimum of 360 Kcal/100g and contains essential vitamins and minerals in adequate quantity. Container should be 400gm or 500gm 1.115 Surgical Instruments maintenance oil in the form of spray 1.116 Lubricant solution for maintenance of electrical operated saw system. This should be documented for above use. 1.117 Long flange adjustable endotracheal tube - Size 7.0 1.118 Cassettes for computerized ambulatory drug delivery devices. Should be small lightweight and patient mobility. Should be durable and High impact & Tamper resistant. Extension set used in conjunction with medication cassettes reservoirs. Should have medication and administration sets with anti-siphon valve and anti-siphon filter 1.119 Skin stapler removal should be made of stainless steel 1.12 Oxidised regenerated cellulose in powder form with pre-filled applicator device 1.121 Covers for plasma sterilization - 500mm x 70mm 1.122 Transducer cable compatible with GEN 11 ultrasonic dissector for open shears 1.123 Scratch pads - for use to clean disposable electrocautery pencils. Should have a surface to stick to the Operating drapes 1.124 Reusable Cordless Generator generates ultrasonic vibration at 55500hz, and it should be cordless, should be directly connected to dissector, should have Integrated LED that provides device feedback, It should be autoclavable 1.125 Reusable Cordless Battery The battery pack should be used up to 200 times,It should be cordless and should be inserted into dissector ,It should be made of Lithium-ion. 1.126 Laparoscopic nebulizer of high-pressure drugs (CAPNOPEN type) for pressurized intraperitoneal aerosol chemotherapy (PIPAC) 2 Non Consumables Items 2.127 Video Laryngoscope - Specifications 1.Must consist of a Monitor with 4 blades (3 Channelled Blades and 1 Non- Channelled Blade). 2. Computerized power management systems with auto Shut Off and auto White balancing. 3. Video Aspect ratio – 4:3,Video Port – RCA Connection to monitor with Cable, Video Resolution – 320 x 240,Video Screen –LCD Display, Video Screen Size – 6.1cm/2.4” diagonal, Material – Polycarbonate / ABS anti- reflective coating on display window. • Power Source – 3 AAA Batteries, Battery Life – 90 minutes (approximate), Battery Status Indicator – Flashes red when batteries need to be changed 2.128 Reusable capacitive-coupling return electrode which does not directly conduct hence providing highest level of safety to the patient by completely eliminating pad site burns to suit all ADULT Patients, made of Akton polymer. 2.129 Kochers Forceps Straight 230mm made of high quality surgical grade stainless steel 2.13 Debakey Vascular forceps - Should be 7.5 - 8 with 1.5 mm tips and have flat handles 2.131 Debakey Vascular forceps - Should be 5-6 with 1.5 mm tips and have flat handles 2.132 Potts smith Scissors - Should be minimum of 180 cm and the blades should be 45° and length of 20mm 2.133 Jacobson needle holder - Should have tungsten carbide coated jaws with round/ flat handles. The tip should be 1.2 - 1.4 mm and the lock should be a low profile lock. Should be delicate for use for 5.0 and 6.0 sutures 2.134 Intercostal Tube Occlusion clamp 2.135 Heiss artery forceps curved 8 inches long made of high quality surgical grade stainless steel 2.136 Babcocks tissue Forceps with a jaw width of 11.3mm and length of 270mm or above 2.137 Crile-wood needle holder, tungsten carbide coated. The needle holder should have a minimum of 4000 teeth per square inch for use with 4-0/5-0 sutures. Should have a length of 30cm or more and a jaw length of 18.5mm 2.138 Pulse Oximeter finger probes compatible with the L& T Star plus Monitor 2.139 Pulse Oximeter finger probes compatible with the Comen Monitor 2.14 Pulse Oximeter finger probes compatible with the Neclife Monitor 2.141 Pulse Oximeter finger probes compatible with the Carescape B450 Monitor 2.142 Blood pressure cuff for adults compatible with the Neclife Monitor 2.143 Blood pressure cuff for adults compatible with the Carescape B450 Monitor 2.144 Blood pressure cuff for adults compatible with the Comen Monitor 2.145 Sternal needle holder and wire twister carbide coated. Should have 1800 teeth per square inch for use with 1.0 & 2.0 suture 2.146 Mixter forceps with partial horizontal serrations. Should be minimum length of 230cm 2.147 Mixter forceps with horizontal serrations. Should be minimum length of 170cm 2.148 Cushings needle and tissue forceps carbide coated. Should be straight with semi-sharp dissecting edges and 7 long 2.149 Mayo Harrington Scissors, Supercut. Should be 11 minimum and curved tip 2.15 Kilner skin hook- should be minimum 6 length with 2.5mm tip 2.151 Wiener skin hook with 5 length and 4.5 mm fine tip 2.152 Cushings vein retractor 12 x 15mm and 24 - 25 cm long 2.153 Cushings vein retractor 18mm and 24cm long 2.154 Allison Lung spatula. should be minimum of 12 2.155 Intermittent pneumatic compression device paired for calf with controller equipment with two pairs of leg sleeves and two pairs of leg and thigh sleeves 2.156 Enteral feeding pump - Should have inbuilt power supply and operating on direct 230v. Should have alarm function for AC fail, occlusion, low battery, bubbles and empty bag. Should be dual mode and be switchable for IV mode. Should also have a color display indicating feed and IV mode. 2.157 Spirometry - PC based. Should be able to measure FVC: FVC, FEV0.5, FEV1.0, FEV1.0/FVC, FEF25–75%, FEF75–85%, PEF, MEF75%, MEF50%, MEF25%, FIVC, FIV1.0, FIV1.0/FIVC,SVC: SVC, ERV, IRV, TV. Should also have an integrated soft ware for pre & post comparison. 2.158 Multiparameter monitor for monitoring Pulse, SPO2, BP, RR and ECG (two leads). The equipment should be provided with all necessary accessories. It should a TFT display with a provision to record data. The equipment should have a warranty for a period of two years from the date of installation. 2.159 Bandage/plastic cutting scissors 2.16 Laparoscopic Suction irrigation - should be 5mm and have a length of 42cm and above 2.161 Laparoscopic Bulldog applier - should be 10mm 2.162 Fergusson Mouth gag - Should have serrated tooth plates to fit against the tooth and ratcheted mechanism for self retaining retractions

Key Value

Document Fees
INR 590 /-
EMD
Refer document
Tender Value
INR 1 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail