}

Group- C- Ac Interference Survey For Snmpl ( Sonepat-Meerut ) , As per tender document.-Haryana

Indian Oil Corporation Limited-IOCL has published Group- C- Ac Interference Survey For Snmpl ( Sonepat-Meerut ) . Submission Date for this Tender is 19-07-2021. Survey Works Tenders in As per tender document. Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

28256100
Corrigendum : Group- C- Ac Interference Survey For Snmpl ( Sonepat-Meerut )
Open Tender
Indian
Haryana
As per tender document.
19-07-2021

Tender Details

Group- C- Ac Interference Survey For Snmpl ( Sonepat-Meerut )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Jul-2021 Corrigendum-1 Date 19-07-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Group C: AC interference survey for SnMPL (Sonepat-Meerut)
Sl. No. Item Description Item Code / Make Quantity Units
1 2 Group C: AC interference survey for SnMPL (Sonepat-Meerut) 1
2 60 Group C UP state SnMPL AC interference 2
3 60.1 "Conducting AC interference survey, to detect presence of any AC voltage(induced owing to proximity of any HT transmission line cros sing or running parallel within a distance of 20 M from the pipeline alignment as per approved procedure. The work shall be complet ed in all respects including survey recommending mitigation measures & post mitigation survey. The work includes all tools, tackles, consumables etc. all complete, required for survey / test as deemed necessary and as per the directions of the site engineer / Engi neer-in-Charge. Note : AC interference survey shall be done at respective TLP by connecting data logger to maintain record for minimum 24 hours. The data to be submitted for each such TLP alongwith coloured graph and recommendations." 3 46 KM
4 60.2 Supply and installation of Corrosion coupon with 1 sq. cm bare metal with 2 lead wire of 5 m each 4 5 EA
5 60.3 Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet (Thickness : 3 mm top/ side/rear/front & 5 mm : Bottom plates) with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated term inal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standar d AFC drawing (9200-99900-404-603-03 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination o f cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repair ing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powd er coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like K M location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plat e shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tool s, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge. 5 4 EA
6 70 Group C HR state SnMPL AC interference 6
7 70.1 "Conducting AC interference survey, to detect presence of any AC voltage(induced owing to proximity of any HT transmission line cros sing or running parallel within a distance of 20 M from the pipeline alignment as per approved procedure. The work shall be complet ed in all respects including survey recommending mitigation measures & post mitigation survey. The work includes all tools, tackles, consumables etc. all complete, required for survey / test as deemed necessary and as per the directions of the site engineer / Engi neer-in-Charge. Note : AC interference survey shall be done at respective TLP by connecting data logger to maintain record for minimum 24 hours. The data to be submitted for each such TLP alongwith coloured graph and recommendations." 7 24 KM
8 70.2 Supply and installation of Corrosion coupon with 1 sq. cm bare metal with 2 lead wire of 5 m each 8 3 EA
9 70.3 Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet (Thickness : 3 mm top/ side/rear/front & 5 mm : Bottom plates) with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated term inal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standar d AFC drawing (9200-99900-404-603-03 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination o f cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repair ing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powd er coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like K M location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plat e shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tool s, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge. 13 2 EA
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail