Installation Of 8 Member Capacity Elevetor (Lift) In Taluk Panchayath Office At Mini Vidhana Soudha, Ramanagara Town & Dist. (Design, Supply & Installation Of 1 No. Lift Of 8 Passenger Capacity For B+G+2 Floors, Including All Civil And Electrical Works -Karnataka

Rural Development Panchayath Raj Engineering Department-RDPRED has published Installation Of 8 Member Capacity Elevetor (Lift) In Taluk Panchayath Office At Mini Vidhana Soudha, Ramanagara Town & Dist. (Design, Supply & Installation Of 1 No. Lift Of 8 Passenger Capacity For B+G+2 Floors, Including All Civil And Electrical Works . Submission Date for this Tender is 05-07-2021. Coats and Jackets Tenders in Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

28248547
Installation Of 8 Member Capacity Elevetor (Lift) In Taluk Panchayath Office At Mini Vidhana Soudha, Ramanagara Town & Dist. (Design, Supply & Installation Of 1 No. Lift Of 8 Passenger Capacity For B+G+2 Floors, Including All Civil And Electrical Works
Open Tender
Indian
Karnataka
05-07-2021

Tender Details

Installation Of 8 Member Capacity Elevetor (Lift) In Taluk Panchayath Office At Mini Vidhana Soudha, Ramanagara Town & Dist. (Design, Supply & Installation Of 1 No. Lift Of 8 Passenger Capacity For B+G+2 Floors, Including All Civil And Electrical Works On Turnkey Basis And Comprehensive Annual Maintenance Including All Kinds Of Routine Preventive & Corrective (Breakdown) Maintenance For One Year) 1. Supplying And Wiring Adopting Loop System In Existing Pvc Conduit /Casing Capping Using 2X1.5Sqmm (Phase & Neutral) & 1X1.0 Sqmm (Earth Wire) Frls Multi Strand Pvc Insulated Copper Wire (Confirming To Is-694: And Latest Amendments) With A 6Amps Flush Type Sp Control Switch Shall Be Fixed On The Existing Plastic Sheet/ Gang Box, The Other End Of The Wires Shall Be Terminated With Sufficient Loose Length In A Wood/Pvc Round Block. Complete For Each Outlet. Medium Point Above 3Mtr Upto 6Mtr From Tapping Point To Out Let Via Switch, 2. Wiring For Lighting/Power Circuit Using One Of Frls Pvc Insulated 1100V Grade, Multistrand Copper Wire With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:Confirming To Latest Amendments. 1.5 Sqmm., 3. 2.5 Sqmm., 4. Supplying And Flush Mounting Powder Coated / Galvanized Metal Box Suitable For Mounting Modular Switch Plates. The Box Should Be Firmly Flush Mounted After Due Groove Cutting In Brick/Stone/C.C Wall. 6Way, 5. Supplying And Fixing Superior Quality Modular Switch Mounting Polycarbonate Plate With Necessary Supporting Back Plate With Required Nos. Of Machine Screws, Bolts Nuts Etc., Complete On The Existing Metal/Pvc Box. 6 Module, 6. Supplying And Fixing Of Modular Switch & Connected Accessories On Existing Modular Switch Plate. 6Amps One Way Switch, 7. 6Amps 3Way Socket, 8. Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On/Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming.50-63Amps Tpn, 9. Supplying, Fixing And Wiring Earth Leakage Miniature Circuit Breaker (Elmcb) 240/450V Up To 300Ma Sensitivity On Existing Wood/Panel Board.63 Amps 4 Pole, 10. Supply And Installation / Fixing / Provision Of Outdoor Type Thermoplastic Modular Panel Enclosure With Transparent Polycarbonate Lid, Shock Proof, Ip65 (Weather Proof), Rust Proof, Dust Proof, Water Proof, Corrosion Proof Having Internally Embedded Gasket On Both Lid And Flap Suitable To Fix Single Phase / Three Phase Energy Meter In Suitable Base Plate And Having A Provision For Fuse / Mcb Cutout With Suitable Transparent Hinged Flap Opening For Operating Mcb Along With Complete Tamper Proof Sealing Facility.600Mmx600mmx170mm, 11. Supplying Fixing And Wiring Earth Electrode For Grounding Of Lifts, Transformers, Dg Sets Etc. Using 40Mm Dia 2.9Mm Thick 2.5 Mtr Long Gi Pipe With Gi Funnel With Mesh And Suitable Size Reducer Fixed On The Top Of The Earth Electrode. The Funnel Should Be Enclosed In A Cc Chamber Of 400X400x400mm With A Cast Iron Cover. The Earth Electrode Shall Have Staggered Holes Of 12Mm Dia And The Electrode Should Be Covered 150Mm All-Round With Alternate Layers Of Salt And Charcoal From The Bottom Of The Cc Chamber. The Connection From The Electrode Is To Be Established Through Gi Strip Using Gi Bolts And Nuts.Electrode, 12. Supplying And Running Of Gi/Copper Strips For Grounding Connections, Using Necessary Fixing Materials As Required.25X3mm Gi Strip, 13. 25X3mm Copper Strip, 14. 600X600x3mm Copper Plate, 15. Supplying Of 1.1 Kv Lt Ug Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 (Part-1) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms/Kms.3.5 Core 25 Sqmm, 16. 3.5 Core 35 Sqmm, 17. Supplying And Running Gi/Copper Conductor For Grounding And (Along With Other Wires In Conduit System Of Wiring) Using Necessary Suitable Size Clamps, Nails, Guttas/Spacers. 8 Swg Copper Wire., 18. Supplying Of ......Feet - Pvc Batten With Integrated Led Tube .....W With High Quality Diffuser With Life Of 25000 Burning Hours & 70% Lumen Maintenance With Cri > 80. Power Input: 220-240V @ 50/60Hz & Power Factor >0.9 Along With Ce Approved. 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition. Led Light Fighting 1 X4- 20/22 W, 19. Supplying & Fixing Of Retrofit Type - Led Bulb.......W With Opal Acrylic Diffuser Comprising Of Led Source With Cct 6500 Degree K, Cri> 70%. Efficacy >80 Lumen Per Watt, Life> 25000 Burning Hours And Compliance To Is 10322/Iec 60598, Lm 79 & Lm 80. The Led Are Driven By Hf Electronic Driver Integrated In The System, With Pf > 0.95, Power Loss Should < 5% Of Lamp Wattage., Short Circuit & Open Circuit Protection To Be Integrated In The Circuit, Thd Less Than 20%, Life As Per Lm 79. The Operating Input Voltage Should Be Between 130 To 275 Volts. Bis Approved And Tested By Nabl/Cpri Accredited Laboratory With 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition..12W, 6500K, 20. Supplying And Fixing Of Round Or Oblong Type Bulk Head Fitting Glass Cover., 21. Design, Supplying, Erecting Testing And Commissioning Of -Passenger/ Bed-Cum-Passenger Hospital Lift With Speed Of 1Mtr Per Second, Variable Voltage Variable Frequency Drive, With Or Without Machine Room For The Available Well Size, Operating At 415 V 3 Phase 50 Cycles Ac Supply, Powder Coated / Stainless Steel Car Entrance Doors Enclosures With Suitable Colour Vinyl Flooring, Led Car Illumination, Emergency Light, Intercom And Fan As Desired By The User, Central Opening / Side Opening Door With Or Without Attendant Operation, 7 Segment Display Buttons, Call Register Indicator, Fireman Drive, Ss Handrails Inside Car, Full Length Infrared Curtain In Car Door, Automatic Rescue Device With Batteries, Voice Announcing In Regional / International Languages, Braille Buttons With One Year Warranty And Maintenance With Necessary Scaffolding And Minor Civil Works Like Fixing Of Guide Rail, Counter Weight Etc., 8-Passenger,4-Stops, 22. Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&P And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts Complete As Per Specifications. C. Prestressed / Reinforced Cement Concrete Grade M-20 & Above. Morth Specification.Wall 3*2.00*0.45*0.90 = 2.43 Cum,

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
INR 13.36 Lakhs /-

BOQ Items

Sl No Item Code Item Name Item Description Unit Quantity
1
01 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch LiftInstallation:
Point
2
2
02 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm. LiftInstallation:
Mtr
30
3
03 2.5 sqmm. LiftInstallation:
Mtr
20
4
04 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6Way LiftInstallation:
Each
1
5
05 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module LiftInstallation:
Each
1
6
06 Supplying and fixing of modular switch & connected accessories on existing modular switch plate. 6Amps one way Switch LiftInstallation:
Each
10
7
07 6Amps 3way socket LiftInstallation:
Each
6
8
08 Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and \C\ Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming.50-63Amps TPN LiftInstallation:
Each
1
9
09 Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.63 Amps 4 pole LiftInstallation:
Each
1
10
10 Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm LiftInstallation:
Each
1
11
11 Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Electrode LiftInstallation:
Nos
2
12
12 Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI strip LiftInstallation:
Nos
2
13
13 25x3mm Copper strip LiftInstallation:
Nos
2
14
14 600x600x3mm Copper plate LiftInstallation:
Nos
2
15
15 Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms.3.5 core 25 sqmm LiftInstallation:
Mtr
2
16
16 3.5 core 35 sqmm LiftInstallation:
Mtr
2
17
17 Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers. 8 SWG Copper wire. LiftInstallation:
Mtr
105
18
18 Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4\- 20/22 w LiftInstallation:
Each
2
19
19 Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition..12W, 6500K LiftInstallation:
Each
5
20
20 Supplying and fixing of round or oblong type bulk head fitting glass cover. LiftInstallation:
Nos
5
21
21 "Design, supplying, erecting testing and commissioning of -passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc., 8-Passenger,4-Stops" LiftInstallation:
Each
1
22
22 Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. C. Prestressed / Reinforced cement concrete grade M-20 & above. MORTH Specification.Wall 3*2.00*0.45*0.90 = 2.43 cum LiftInstallation:
Cum
2.43
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy