Military Engineer Services-MES has published Repair Replacement To Corroded Gi Pipeline In Officers Map Qtrs Incl Repair Maint Of Certain Em Works Of Stp At Gms Under Ge I Gos. Submission Date for this Tender is 08-07-2021. Pipe Laying Tenders in GOPALPUR ON SEA Odisha. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 22-Jun-2021 | REVISED BOQ | BOQ | 08-07-2021 |
Name of Work: REPAIR / REPLACEMENT TO CORRODED GI PIPELINE IN OFFICERS MAP QTRS INCL REPAIR/MAINT OF CERTAIN EM WORKS OF STP AT GMS UNDER GE I GOS. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of brick work or stone/ boulder masonary built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed. | 7 | Cum | |
2 | 2 | M&L Brick work with Fly Ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. | 7 | Cum | |
3 | 3 | M&L 15 mm thick Rendering on fair faces of brick work or concrete surfaces of wall in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed. | 70 | Sqm | |
4 | 4 | M&L for Pre-cast reinforced cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed. | 8 | Cum | |
5 | 5 | S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speified and directed. | 450 | Kg | |
6 | 6 | S&F in repairs ball valves for 20 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. | 100 | Each | |
7 | 7 | S&F in repairs ball valves for 25 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. | 50 | Each | |
8 | 8 | S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed | 100 | Each | |
9 | 9 | S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed | 25 | Each | |
10 | 10 | S&F in repair PP-R globe or gate valves screwed both ends for PPR Pipes of 20 mm bore of pipe complete all as specified and directed. | 50 | Each | |
11 | 11 | S&F in repair PP-R globe or gate valves screwed both ends for PPR Pipes of 25 mm bore of pipe complete all as specified and directed. | 15 | Each | |
12 | 12 | S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed | 60 | Each | |
13 | 13 | S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed. | 20 | Each | |
14 | 14 | S&F ball valves for 20 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. | 60 | Each | |
15 | 15 | S&F ball valves for 25 mm bore of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. | 20 | Each | |
16 | 16 | Taking up or down 15 mm bore steel tubing and connections including cleaning if refixing required complete all as specified and directed. | 140 | RM | |
17 | 17 | Taking up or down 20 mm bore steel tubing and connections including cleaning if refixing required complete all as specified and directed. | 1284 | RM | |
18 | 18 | Taking up or down 25 mm bore steel tubing and connections including cleaning if refixing required complete all as specified and directed. | 272 | RM | |
19 | 19 | M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,\nsunshades, shelves, lintels, etc.; and cutting chases for concealed water\ntubing or concealed conduit wiring, etc., and making good, cutting not\nexc 10 cm girth in Bricks/ stone Masonary wall complete all as specified and directed. | 200 | RM | |
20 | 20 | S&F GI 15 mm bore tubes medium grade (ISI marked) with all fittings fixed complete to walls, ceilings or laid in floors complete all as specified and directed. | 20 | RM | |
21 | 21 | S&F 20 mm bore GI tubes medium grade (ISI marked) with all fittings fixed complete to walls, ceilings or laid in floors complete all as specified and directed. | 50 | RM | |
22 | 22 | S&F25 mm bore GI tubes medium grade (ISI marked) with all fittings fixed complete to walls, ceilings or laid in floors complete all as specified and directed. | 12 | RM | |
23 | 23 | S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed. | 100 | RM | |
24 | 24 | S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed. | 1200 | RM | |
25 | 25 | S & F 25 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed. | 250 | RM | |
26 | 26 | Making connection of PPR distrubtion bracnch with PPR main of following outer dia of pipe 16 to 40mm size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. | 200 | Each | |
27 | 27 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed. | 20 | RM | |
28 | 28 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed. | 34 | RM | |
29 | 29 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 25 mm bore of pipe complete all as specified and directed. | 10 | RM | |
30 | 30 | S&F in repair bib taps 15 mm bore, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed | 130 | Each | |
31 | 31 | Supply, installing, testing and commissioning in replacement of out door type LT feeder panel, outdoor type , floor mounted, factory made , rust proof, Vermin Proof of double door made out of box 3 mm thick sheet , 3 phase, 4 wire, 440 volt, AC, 50HZ, suitable aluminium bus bar of capacity 100 Amps, with colour code sleeves,complete housing the following switch gears/ accessories and suitable foundation/ platform complete all asdirected,.Following are reqire as :-\n(1.) Bus Bar 04 Nos. of 100 Amps capacity (01 Set).\n(2) LED Indicating lamps R,Y,B -01 Set.\n(3) MCCB 63A, 4 Pole- 415 Volts, 36KA , 50 HZ 1 No ( Incoming), MCB SPN 32 Amps, 10 KA - 02 Nos (O/G).\n(4) 63 Amp 4 pole change over switch, 415 Volt -01 Nos.\n(5)0 to 500 Volt meter ( with selected switch & CT coil )-01 Nos.\n(6) 0 to 100 Amper meter ( with selector switch & CT coil -01 Nos.\n(7) 3 phase DOL Starter, 415 Volts 9-16 Amps cantrolled by one MCB TP 32 Amps 415 Volt with single along with Single phase preventor, over load relay & under volt protection complete with On/Off push Button control and indication lamps including wiring complete as specified and directed. - 07 Nos.\n( For Air Blower 1 & 2 (2.2 KW), FAB FEED PUMP- 1 & 2 (0.75 KW), FILTER FEED PUMP 1 & 2 (0.75 KW) & EQUILIZATION TANK.).\n\n\n\n\n | 3 | Each Job | |
32 | 32 | Supply & Fixing Name Board for Sewage Treatment Plant, (09 Nos ) as making good GI seet, size 1200x600x180 mm, 3 mm thickness of the GI sheet to fix the LED Light 10 W,- 02 Nos wiring with copper, 1.5 mm, Iron angle for fixing the Name Board - 02 Nos angle of length 2.5 mtr + 2.5 mtr for two sides fix in the ground, make a foundation for angle and all connecting items complete all as specified and directed. | 9 | Each Job | |
33 | 33 | M&L in replacement of earthing complete with galvanised iron strip 32mm x 6mm and galvanised iron earth plate electrode 600x600x6mm thick, burried directly in ground(earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 2.25 meters below normal ground level, connected to galvanised earth lead wire 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel and GI pipe 'L' grade of 40mm dia for protection of earth lead and 20mm dia GI pipe 'M' grade for watering with wire wash funnel etc as shown in electrical plate No. 5 of SSR part - I (2009) connected to earthing test point all as specified or indicated including testing on completion as per IE rule. | 22 | Each | |
34 | 34 | Supply, laying and testing in replacement XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve for cable of size 50 sqmm 3.5 core with lugs complete all as specified and directed. - Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items Make:- Havells / polycab / cci / nicco / Gloster or equivalent | 80 | RM | |
35 | 35 | All as per item No 34 above but 50 sqmm 3.5 core complete all as specified and as directed | 80 | RM | |
36 | 36 | All as per item No 34 above but 35 sqmm 3.5 core complete all as specified and as directed | 80 | RM | |
37 | 37 | All as per item No 34 above but 25 sqmm 4 core complete all as specified and as directed | 80 | RM | |
38 | 38 | Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5M deep for foundation/cable trench, not exceeding 10 Sqmm on plan and getting out in soft/loose soil complete all as specified and as directed. | 96 | Cum | |
39 | 39 | Returning filling including spreading, levellingand well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed. | 57 | Cum | |
40 | 40 | Removal of surplus soil to a distance not exceeding 50M and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified and directed.. | 77 | Cum | |
41 | 41 | Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. | 65 | Cum | |
42 | 42 | Supply and laying flyash building bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and directed. | 14 | per 1000 Nos | |
43 | 43 | S & F on load change over switch 100Amp 4 pole, 415 Volts, AC cubical type complete all as specified and directed. Make: Havells/L&T/GEPC or equivalent | 5 | Each | |
44 | 44 | Supply and Fix in repair submersiable non clog motor of capacity of 5 HP/3.5 KW of model No. 3700CW with delivery size with 55mm dia complete all as specified and directed. Make:- KIRLOSKAR or equivalent. | 3 | Each | |
45 | 45 | S & F 1 DOL startor pump motor of capacity 13-22A, 360 V (50x50x50) Dark Grey complete all as specified and directed. Make:- L & T or equivalent. | 3 | Each | |
46 | 46 | Supply and replacement thermal over load relay of range 6.5 to 10 Amps complete all as specified and directed Make- CG/L&T/ BCH/C&S or equivalent. | 10 | Each | |
47 | 47 | Supply and replacement CT Coil 60/5 Amps Make : : L&T/AE/C&S/L&T/AE/C&S or equivalent. | 10 | Each | |
48 | 48 | S & F Galvanised corrugated mild steel sheeting of size 0.63mm with two corrugated side lap, fixed with J type hook and washers in roofs, walls etc with grade of zink coating 125 complete all as specified and directed. | 30 | Per SQM | |
49 | 49 | M & L, cement concrete 1 : 3 : 6 type C-2 using (40 mm graded stone aggregate) as in fdn, filling and mass concrete, complete all as specified and directed. | 9 | Cum | |
50 | 50 | Supply and replacement of MCB 63 Amp TPN AC, 415 volts, 25 KA s complete all as specified and directed. Make – CG/HAVELL’S/ L&T/C&S or equivalent.. | 10 | Each | |
51 | 51 | Supply and replacement of MCB 40 Amp TPN AC, 415 volts, 25 KA s complete all as specified and directed. Make – CG/HAVELL’S/ L&T/C&S or equivalent. | 10 | Each | |
52 | 52 | Supply and replacement of MCB 32 Amp TPN AC, 415 volts, 25 KA s complete all as specified and directed. Make – CG/HAVELL’S/ L&T/C&S or equivalent. | 10 | Each | |
53 | 53 | Supply and fixing in replacement of MCCB 4 pole 415 volts of capacity 100 amps 50 HZ, with rupturing capacity 35 KA complete all as specified and directed.. Make Standard/ Havells/ L & T / MDS/Legrand/HPL or equivalent. | 2 | Each | |
54 | 54 | Supply and fixing in replacement of MCCB 4 pole 415 volts of capacity 63 amps 50 HZ, with rupturing capacity 35 KA complete all as specified and directed.. Make Standard/ Havells/ L & T / MDS/Legrand/HPL or equivalent. | 2 | Each | |
55 | 55 | S&F 110 mm OD PPR Pipe 3 layer SDR 7.4 & SDR 11 UV stabilized and antimicrobical welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded PPR Fittings fixed complete to walls ,celling or in floors etc complete all as specified and directed. Make- SFMC or equivalent of higher cost. | 50 | RM | |
56 | 56 | S&F 63 mm OD PPR Pipe 3 layer SDR 7.4 & SDR 11 UV stabilized and antimicrobical welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded PPR Fittings fixed complete to walls ,celling or in floors etc complete all as specified and directed. Make- SFMC or equivalent of higher cost.. | 50 | RM | |
57 | 57 | S&F 50 mm OD PPR Pipe 3 layer SDR 7.4 & SDR 11 UV stabilized and antimicrobical welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded PPR Fittings fixed complete to walls ,celling or in floors etc complete all as specified and directed. Make- SFMC or equivalent of higher cost. | 60 | RM | |
58 | 58 | S&F 40 mm OD PPR Pipe 3 layer SDR 7.4 & SDR 11 UV stabilized and antimicrobical welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded PPR Fittings fixed complete to walls ,celling or in floors etc complete all as specified and directed. Make- SFMC or equivalent of higher cost. | 70 | RM | |
59 | 59 | S&F 32 mm OD PPR Pipe 3 layer SDR 7.4 & SDR 11 UV stabilized and antimicrobical welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded PPR Fittings fixed complete to walls ,celling or in floors etc complete all as specified and directed. Make- SFMC or equivalent of higher cost. | 80 | RM | |
60 | 60 | S&F 110 mm OD PPR gate valve (brass insert) complete all as specified and direcdted. Make- SFMC or equivalent of higher cost. | 5 | Each | |
61 | 61 | S&F 63mm OD PPR gate valve (brass insert) complete all as specified and direcdted. Make- SFMC or equivalent of higher cost. | 6 | Each | |
62 | 62 | S&F 50 mm OD PPR gate valve (brass insert) complete all as specified and direcdted. Make- SFMC or equivalent of higher cost. | 5 | Each | |
63 | 63 | S&F 40mm OD PPR gate valve (brass insert) complete all as specified and direcdted. Make- SFMC or equivelent of higher cost. | 5 | Each | |
64 | 64 | S&F 32mm OD PPR gate valve (brass insert) complete all as specified and direcdted. Make- SFMC or equivalent of higher cost. | 5 | Each | |
65 | 65 | Supply and Fix Battery, 12 volt, 50 Hz, 80 Ah, complete all as specified and direcdted. Make :-Exide Car Battery or equivalent. | 10 | Each | |
66 | 66 | Supply and replacement CT Coil 60/5 Amps Make : : L&T/AE/C&S/L&T/AE/C&S or equivalent. | 5 | Each | |
67 | 67 | S&F in repalcement of 3.7 KW DOL motor fan for feed pump complete all as specified and directed, Make- CG/L&T/C&S/Seimens/BCH or equivalent. | 4 | Each | |
68 | 68 | S&F in repalacement contactor NO+NC 16 Amps capacity 240 volts, 50 HZ, DP complete all as specified and directed . Make- CG/L&T/Seimens or equivalent. | 6 | Each | |
69 | 69 | S & F in replacement of Dosing Pump of capacity 0-6 Liters/Hrs and working pressure capacity of 04 kg incl all necessary fittings complete all as specified and directed. | 7 | Each | |
70 | 70 | S & F in replacement of Dosing Tank of capacity 200 Liters, material ofconstruction LDPE/HDPEincluding all necessary connecting materials complete all as specified and directed. | 4 | Each | |
71 | 71 | S & F in replacement of Dosing Tank of capacity 100 Liters, material ofconstruction LDPE/HDPEincluding all necessary connecting materials complete all as specified and directed. | 3 | Each | |
72 | 72 | S&F in replacement contactor NO+NC 9 Amps capacity 230 volts, 50 Hz, DP complete all as specified and directed, Make- CG/L&T/C&S/Seimens or equivalent. | 5 | Each | |
73 | 73 | M&L for preparation of old surface by scraping and smoothing the surface with water emery paper and painting with approved colour of two coat synthetic enemelled paint over a coat of red oxide primer and writing letters/numbers and DATE OF CLEANING of sewage treatment plants of capacities:- ( 30 KLD PH, 30 KLD, JCOS Mess, 60 KLD, 360 KLD , 80 KLD, 70 KLD & 100 KLD) Moving Bed Bio Reactor 1 & 2 CUM/Day complete all as specified and direcdted. | 1 | Each Job | |
74 | 74 | All as per item No 73 above but dual Media filter | 1 | Each Job | |
75 | 75 | All as per item No 73 above but Activated carbon filter | 1 | Each Job | |
76 | 76 | All as per item No 73 above but Exposed water pipe lines. | 1 | Each Job | |
77 | 77 | All as per item No 73 above but filter feed pump | 1 | Each Job | |
78 | 78 | All as per item No 73 above but filter backwash pump | 1 | Each Job | |
79 | 79 | All as per item No 73 above but distribution panel board | 1 | Each Job | |
80 | 80 | All as per item No 73 above but Tube settler tank | 1 | Each Job | |
81 | 81 | All as per item No 73 above but Air Blower with compressor 1 & 2 | 1 | Each Job | |
82 | 82 | Checking and inspecting of the LT outdoor type panel board system throughly, including removing of the unserviceable damaged control wiring and rewiring of the same with suitable size and length of copper conductor FRLS , checking of instruments , welding of panels,cleaning with bakelite and carried out of necessary painting matching with existing colour including tightining for all the loose contacts, reconnecting back and testing complete all as specified and directed .\n | 5 | Each |