Rate Contract For Carrying Out M And L Repair Works For Crvts-Frvts-Fire Water Tanks- Pipelines , Paintings Etc . , At Depots- Terminals-Afss- Rcds In Kerala State . , KERALA STATE OFFICE-Kerala

Indian Oil Corporation Limited-IOCL has published Rate Contract For Carrying Out M And L Repair Works For Crvts-Frvts-Fire Water Tanks- Pipelines , Paintings Etc . , At Depots- Terminals-Afss- Rcds In Kerala State . . Submission Date for this Tender is 13-07-2021. Pipe Laying Tenders in KERALA STATE OFFICE Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

28235478
Rate Contract For Carrying Out M And L Repair Works For Crvts-Frvts-Fire Water Tanks- Pipelines , Paintings Etc . , At Depots- Terminals-Afss- Rcds In Kerala State .
Open Tender
Indian
Kerala
KERALA STATE OFFICE
13-07-2021

Tender Details

Rate Contract For Carrying Out M And L Repair Works For Crvts-Frvts-Fire Water Tanks- Pipelines , Paintings Etc . , At Depots- Terminals-Afss- Rcds In Kerala State .

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 14.16 Crore /-

BOQ Items

Name of Work : RATE CONTRACT FOR CARRYING OUT M&I REPAIR WORKS FOR CRVTS/FRVTS /FIRE WATER TANKS/PIPELINES ETC., AT DEPOTs/TERMINALs/ AFSs/ RCDs IN KERALA STATE
Sl. No. Item Description Item Code / Make Quantity Units
1 1 DISMANTLING WORKS BI01010001010000000000000515BI0100001113
2 2 Dismantling of pipelines (product/ FH) including mechanical/ gas cutting of the pipe lines and removal include dismantling of all above ground & underground pipelines/draining of water etc., complete. BI01010001010000000000000515BI0100001114
3 3 Note: a) Necessary earthwork excavation, if required, shall be part of dismantling works. b) The dismantled pipes, valves & flanges shall be handed over to the safe custody of the Corporation. BI01010001010000000000000515BI0100001115
4 4 25 mm dia to 65mm dia BI01010001010000000000000515BI0100001116 1 M
5 5 80 mm dia to 150mm dia BI01010001010000000000000515BI0100001117 1 M
6 6 200 mm dia to 300mm dia BI01010001010000000000000515BI0100001118 1 M
7 7 350 mm dia to 450mm dia BI01010001010000000000000515BI0100001119 1 M
8 8 Dismantling and removing the existing CS GATE/ ROSOV/ DBBV/ MOV/ GOV/ NRV/ BALL/ BUTTERFLY/ AUDCO valves of the followings sizes without any damage including removing cable termination wherever required, removing the bolts/nuts/washers, providing proper supports to adjacent pipeline, stacking the same, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001120
9 9 50 mm dia BI01010001010000000000000515BI0100001121 1 EA
10 10 80 mm dia BI01010001010000000000000515BI0100001122 1 EA
11 11 100 mm dia BI01010001010000000000000515BI0100001123 1 EA
12 12 150 mm dia BI01010001010000000000000515BI0100001124 1 EA
13 13 200 mm dia BI01010001010000000000000515BI0100001125 1 EA
14 14 250 mm dia BI01010001010000000000000515BI0100001126 1 EA
15 15 300 mm dia BI01010001010000000000000515BI0100001127 1 EA
16 16 350 mm dia BI01010001010000000000000515BI0100001128 1 EA
17 17 400 mm dia BI01010001010000000000000515BI0100001129 1 EA
18 18 450 mm dia BI01010001010000000000000515BI0100001130 1 EA
19 19 Dismantling and removing the shell nozzles without any damage to shell plate including cutting, gouging, grinding, stacking the same, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001131
20 20 50 mm to 100 mm dia BI01010001010000000000000515BI0100001132 1 EA
21 21 150 mm to 300 mm dia BI01010001010000000000000515BI0100001133 1 EA
22 22 350 mm to 450 mm dia BI01010001010000000000000515BI0100001134 1 EA
23 23 Supplying & welding necessary Dummy reinforcement plate for closing the shell nozzle hole as per standards including cutting, gouging, grinding, welding the plate, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001135
24 24 50 mm to 100 mm dia (with 8mm thk to 14mm thk new MS plates) BI01010001010000000000000515BI0100001136 1 EA
25 25 150 mm to 300 mm dia (with 8mm thk to 14mm thk new MS plates) BI01010001010000000000000515BI0100001137 1 EA
26 26 350 mm to 450 mm dia (with 8mm thk to 14mm thk new MS plates) BI01010001010000000000000515BI0100001138 1 EA
27 27 Dismantling the MS rolling ladder including disconnecting the same from platform, cutting, gouging, grinding & removing the same with suitable capacity crane without any damage to shell plate/deck and stacking the same safely, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001139
28 28 8 M dia x 7 M high - FRVTs BI01010001010000000000000515BI0100001140 1 LS
29 29 10 M dia x 9 M high - FRVTs BI01010001010000000000000515BI0100001141 1 LS
30 30 12 M dia x 9 M high - FRVTs BI01010001010000000000000515BI0100001142 1 LS
31 31 16 M dia x 14 M high - FRVTs BI01010001010000000000000515BI0100001143 1 LS
32 32 32 M dia x 15 M high - FRVTs BI01010001010000000000000515BI0100001144 1 LS
33 33 32 M dia x 9.80 M high - FRVTs BI01010001010000000000000515BI0100001145 1 LS
34 34 32 M dia x 15 M high - FRVTs BI01010001010000000000000515BI0100001146 1 LS
35 35 40 M dia x 9.60 M high - FRVTs BI01010001010000000000000515BI0100001147 1 LS
36 36 Gas cutting of the shell to annular plate, bottom plate or shell butt welding joint along the seam neatly with minimum wastage and without damaging the existing shell plate. \nThe job also includes:\na) Any other weld joints- butt or fillet of max 25mm thick plate.\nb) Temporarily dismantling the 3" or 4" drain pipes inside the tank and re-installing the same after rectification of the tank.\nc) Stacking the cut plates properly as per site instructions.\nd) Cutting of shell to provide window for taking out dismantled plates or taking in new plates.\n\n BI01010001010000000000000515BI0100001148 1 M
37 37 The dismantling of damaged roof supporting structural:\nRate is inclusive of dismantling of roof truss/girders/columns including gusset plates, cleats, supports, roof structural supports, angles, railing angles, flats, curb angles, etc. The theorotical sectional weight of structurals as per IOC's standard drawing will only be considered for calculating the tonnage of dismantlled item. Weight of appurtenances will not be considered for payment purpose.\nDismantled steel structurals will be the property of the contractor and rebate towards this should be considered while quoting. Scaffolding, if required will be paid separately.\n BI01010001010000000000000515BI0100001149 1 MT
38 38 Dismantling of structurals:\nGouging / grinding and dismantling of hand rails, wind girders, corroded staircase including pad of support channels of landing platforms from all sides, support angle of staircase step from all sides to the shell plates at the affected places. Dismantled material will be property of party and is to be taken by them. Rebate towards cost of scrap to be considered while quoting for this item. Scaffolding, if required will be paid separately. BI01010001010000000000000515BI0100001150 1 MT
39 39 Dismantling the existing combined gauge well pipe (500 mm dia) including cutting, gouging, grinding & removing the same with suitable capacity crane without any damage to shell plate/deck, stacking the same safely, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001151
40 40 Upto 10 M high tanks - FRVTs BI01010001010000000000000515BI0100001152 1 LS
41 41 10 M to 15 M high tanks - FRVTs BI01010001010000000000000515BI0100001153 1 LS
42 42 Degassing & De-sludging into secondary containment like concrete or earth pit, barrels or tank truck etc and cleaning of the bottom of floating roof along with support legs, bottom, roof and shell plates upto resting position of roof in case of FR Tanks and bottom and shell plates upto 1.5 m high of CR Tanks by hydro jetting method with all tool sand tackles and explosion proof degassing unit / sludge pumps etc.\nNote : For above item, the approved sub vendor shall directly report to the Location Incharge and the entire cleaning and degasification process shall be done under supervision of Operating personnel of Terminal. Hot work shall commence only after tank is certified as degassed by the Location Incharge. Water @ 18 lpm and electricity 3 phase for this item shall be provided by IOCL. BI01010001010000000000000515BI0100001154
43 43 Vertical tanks(FR/CR) - 8 M dia to 12 M dia BI01010001010000000000000515BI0100001155 1 LS
44 44 Vertical tanks(FR/CR) - 14 M dia to 20 M dia BI01010001010000000000000515BI0100001156 1 LS
45 45 Vertical tanks(FR/CR) - 20 M dia to 30 M dia BI01010001010000000000000515BI0100001157 1 LS
46 46 Vertical tanks(FR/CR) - 40 M dia to 50 M dia BI01010001010000000000000515BI0100001158 1 LS
47 47 Dismantling the plates of CRVT/FRVT either partly or in full as directed, by gas cutting from the existing weld seams & removing the MS plates from the tank by mechanical means, with utmost precaution and neatly straightening and storing at place indicated by site engineer anywhere in IOC premises, complete, irrespective of lead and lift as directed. The rate includes the cost of labour, gases, providing necessary temporary supports, safe walk ladder, safety precautions etc., all necessary equipments, all necessary structures, clamps, suitable non-combustible material wedges, etc. complete to the satisfaction of site-in-charge. Plan area and average thickness of roof plates will be considered for calculating the qty of dismantled plates, and weight of appurtenances will not be considered separately, and no extra payment for the same will be made. BI01010001010000000000000515BI0100001159
48 48 Note: Contractor has to submit the dismantling methodology clearly stating the restraining techniques to be involved so that circularity of the undamaged (to be retained) shell/ bottom/ roof plates remains undisturbed, prior to commencement of work and has to get it approved from IOCL. Plates and structures, appurtenances should be dismantled with utmost care as these are to be reutilized. BI01010001010000000000000515BI0100001160
49 49 a) CRVT/FRVT BI01010001010000000000000515BI0100001161 1 TON
50 50 Dismantling and reconnecting, if any after completion of welding, of existing catwalks connected to roof, pipelines connected to tank body etc. including isolation during welding & cutting etc. and re-connection after completion of work. BI01010001010000000000000515BI0100001162 1 EA
51 51 Dismantling of Fire/ Jockey pump including removing from the foundation, disconnecting the suction/ delivery of the pump, shifting & stacking the same without any damage, H/O to IOC etc., complete as per instructions at site. BI01010001010000000000000515BI0100001163
52 52 Fire pump with Engine set - 288/410/616 KL/HR BI01010001010000000000000515BI0100001164 1 EA
53 53 Jockey pump with its connected pipelines - all capacities BI01010001010000000000000515BI0100001165 1 EA
54 54 Air-compressors/ Fire pump fuel tank - all capacities BI01010001010000000000000515BI0100001166 1 EA
55 55 M&I REPAIR WORKS BI01010001010000000000000515BI0100001167
56 56 Replacement of necks of Manholes/ Nozzles of tanks with new necks including careful removal of welding between nozzles and shell plates/ reinforcement plate by light pencil grinding without damaging them, dismantling the manhole/nozzle, supplying & providing the following necks made out of MS plates, bending into shape, welding with radio-graphic quality to shell plates/ reinforcement plate, radiography of welded joints including rectification & re-testing of welds, DP test of weld between each nozzle and reinforcement plate/shell plate after root run and after complete welding, pneumatic test of re-inforcement plate / shell plate after welding completion at 15 PSI, touch-up painting of welded areas as per specification etc., as per IS 803 and B&R drawings and instructions at site. BI01010001010000000000000515BI0100001168
57 57 Scope of the works includes a) supplying & welding of necessary bolting flange, supplying & providing cover plate, making joints including handling, straightening, fabricating, erecting, assembling, welding, drilling holes, bolts/ nuts/ washers etc., CAF-9 (or) equivalent 3mm gasket. BI01010001010000000000000515BI0100001169
58 58 b) Surface preparation / cleaning / painting works are as per IOC painting scheme specification given in the tender. BI01010001010000000000000515BI0100001170
59 59 Neck for Shell Manhole: with MS plate conforming to IS-2062 for neck & cover plate. B&R drg. no. BR/FR/221 & BR/FR/222. BI01010001010000000000000515BI0100001171
60 60 Upto 750 mm dia , 12 mm thick BI01010001010000000000000515BI0100001172 1 EA
61 61 750 mm dia , 14 mm thick BI01010001010000000000000515BI0100001173 1 EA
62 62 750 mm dia , 16 mm thick BI01010001010000000000000515BI0100001174 1 EA
63 63 750 mm dia , 18 mm thick BI01010001010000000000000515BI0100001175 1 EA
64 64 750 mm dia , 20 mm thick BI01010001010000000000000515BI0100001176 1 EA
65 65 Neck for Shell Nozzle: with MS plate conforming to SA-106 Gr.B upto 250mm dia and IS-226/2062 for for more than 250mm dia for neck plate. SORF & Blind flanges as per Specification given in the tender. B&R drg. no. BR/CR/223, 224,225,226. BI01010001010000000000000515BI0100001177
66 66 50 mm dia 6 mm thick BI01010001010000000000000515BI0100001178 1 EA
67 67 80 mm dia 8 mm thick BI01010001010000000000000515BI0100001179 1 EA
68 68 100 mm dia 10 mm thick BI01010001010000000000000515BI0100001180 1 EA
69 69 150 mm dia 12 mm thick BI01010001010000000000000515BI0100001181 1 EA
70 70 200 mm dia 12 mm thick BI01010001010000000000000515BI0100001182 1 EA
71 71 250 mm dia 12 mm thick BI01010001010000000000000515BI0100001183 1 EA
72 72 300 mm dia 12 mm thick BI01010001010000000000000515BI0100001184 1 EA
73 73 350 mm dia 12 mm thick BI01010001010000000000000515BI0100001185 1 EA
74 74 400 mm dia 12 mm thick BI01010001010000000000000515BI0100001186 1 EA
75 75 450 mm dia 12 mm thick BI01010001010000000000000515BI0100001187 1 EA
76 76 Roof Manhole: with MS plate conforming to IS-2062 for neck & cover plate. B&R drg. no. BR/FR/277. BI01010001010000000000000515BI0100001188
77 77 500mm dia BI01010001010000000000000515BI0100001189 1 EA
78 78 80mm/ 100mm dia roof nozzle with pipes as per B&R drg. BI01010001010000000000000515BI0100001190 1 EA
79 79 50mm dia roof nozzle with pipes as per B&R drg. BI01010001010000000000000515BI0100001191 1 EA
80 80 Provision of 1 no rim vent of 4" dia as per B&R drawing and providing 6"x4" reducer for one (existing) vent BI01010001010000000000000515BI0100001192 1 EA
81 81 Replacement of Centre/ Emergency Drain including dismantling the Old Centre drain and Pipe by Gouging, Cutting without Damage to the Double Deck plate, supply of Seamless 100 mm dia MS pipes (SCH-80), Structural, Plate, reinforcement plate, fabrication, welding, fixing & testing of new 100 mm dia pipe & new re-inforcement plate, necessary stiffeners, DP test etc., as per drawings and as per specifications & instructions at site. BI01010001010000000000000515BI0100001193
82 82 Central Drain - as per B&R drg no. BR/FR/295 BI01010001010000000000000515BI0100001194 1 LS
83 83 Emergency Drain - as per B&R drg no. BR/FR/267 BI01010001010000000000000515BI0100001195 1 LS
84 84 Replacement of damaged web/ flange plate of wind girder including cutting the damaged web plate, butt welding the supplied MS plates neatly without any damage to shell plate/flange plate of wind girder, tools/tackles, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001196 1 KG
85 85 Supply, Fabrication, Erection of seamless MS pipe for leg supports & air bleeder vents pipes for Existing Double Deck including supplying & providing handle, plate, holes, slot, 38mm dia hot rolled PIN, all lead & lifts, transportation etc., complete as per revised B&R drg no. BR/FR/250, BR/FR/252, BR/FR/265 & connected drgs. and as per instruction at site. Drawing shall be submitted to IOCL for approval. BI01010001010000000000000515BI0100001197
86 86 63.5 mm dia (2.5" NB SCH-80) - Leg supports for FRVT BI01010001010000000000000515BI0100001198 1 M
87 87 38.1 mm dia (1.5" NB SCH-40) - Auto bleeder vent supports for FRVT BI01010001010000000000000515BI0100001199 1 M
88 88 Supplying and Providing Sleeves for the Leg Supports in the Double Deck as per the attached drawing including supply of Seamless MS pipes, reinforcement plate, fabrication, welding, fixing, all lead & lifts, transportation etc., complete as per revised B&R drg no. BR/FR/250, BR/FR/252, BR/FR/264, BR/FR/265 and as per instruction at site. Rate is inclusive of dismantling the Old Sleeve Pipe by cutting & gouging without damage to the Double Deck plate. BI01010001010000000000000515BI0100001200
89 89 88.9 mm dia (3.5" NB SCH-80) - Sleeve for Leg support - FRVT BI01010001010000000000000515BI0100001201 1 EA
90 90 203 mm dia (8" NB SCH-40) - Sleeve for Auto bleeder vent - FRVT BI01010001010000000000000515BI0100001202 1 EA
91 91 63.5 mm dia (2.5" NB SCH-40) - Intermediate sleeve/baffle plates/cover for Auto bleeder vent BI01010001010000000000000515BI0100001203 1 SET
92 92 Supplying and Providing Neoprene Gaskets for the deck pontoon hatch cover of approved make & as per B&R drg. No. BR/FR/268 & connected drgs., all lead & lifts, transportation etc., complete and as per instruction at site. BI01010001010000000000000515BI0100001204
93 93 For 508 mm dia (20") inspection hatch of pontoon - FRVT BI01010001010000000000000515BI0100001205 1 EA
94 94 Trimming the concrete surface of shoulder of sand pad foundation including the chipping off the concrete (approx.6mm to 20mm thick) to bring down the surface to below the bottom plate level, surface finishing the undulations with CM 1:3 neatly, curing, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001206
95 95 For sand pad foundation BI01010001010000000000000515BI0100001207 1 M2
96 96 Providing sand-bitumen mix for voids between bottom plate & bitumen carpet of sand pad pad foundation including hot-mixing with required ratio, packing the same neatly into the gap for upto 50mm thick & 150mm width, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001208
97 97 For sand pad foundation BI01010001010000000000000515BI0100001209 1 M
98 98 Dismantling of existing air vents of 6 inch dia by gas cutting and stacking at designated place within terminal, supply, fabrication, handling and fixing air vents of 10 inch LRB type as per IOCL drg. Ref. S-869 and fixing as per drg. Ref. BR/CR/278 including providing new nozzle on roof of 250 mm dia, SO flanges as required etc. Dismantled air vent material will be property of party and is to be taken by them. Rebate towards cost of scrap to be considered while quoting for this item. BI01010001010000000000000515BI0100001210 1 EA
99 99 Drilling tell tale hole on reinforcement pads of manholes of specified dia without damaging the shell and plugging the same by providing threaded screw. BI01010001010000000000000515BI0100001211 1 EA
100 100 Supplying and welding 2 nos handles of 12 mm round bars bend in U shape on each pontoon inspection hatch cover. BI01010001010000000000000515BI0100001212 1 EA
101 101 Supplying, fixing of existing brass sleeve (ring in two halves) of 50mm depth x 5mm thick in the top and bottom inner circumference of gauge pipe sleeve by brazing and / or fixing to the nut/bolts of gauge well sleeve by means of strips. BI01010001010000000000000515BI0100001213 1 LS
102 102 Supplying providing 6 mm thick, 2 ply neoprene gasket as per drawing in between flanges of existing 400 mm dia gauge well housing, providing nut/bolts etc as required. BI01010001010000000000000515BI0100001214 1 EA
103 103 Welding:\nCleaning, gouging/grinding as required and carrying out welding of joints of required size wherever required/left out on the tank after surface preparation by grinding if required. Item includes testing of weld joints by DP test, chalk kerosene etc, if required. Scaffolding , if required, will be paid separately. BI01010001010000000000000515BI0100001215
104 104 Fillet Weld BI01010001010000000000000515BI0100001216
105 105 a) 5-8 mm size BI01010001010000000000000515BI0100001217 1 M
106 106 b) Above 8 to 12 mm size BI01010001010000000000000515BI0100001218 1 M
107 107 Butt weld from one side for annular plate or both side for shell plates including back gouging as required, based on thickness of shell plate/annular plate to be welded etc. Incase welding of plates of different thickness, thickness of thinner plate will be considered. This item may also be operated for closing of window cut on shell for taking out dismantled plates or taking in new plates. BI01010001010000000000000515BI0100001219
108 108 a) 5-10 mm size BI01010001010000000000000515BI0100001220 1 M
109 109 b) Above 10 -20 mm size BI01010001010000000000000515BI0100001221 1 M
110 110 c) Above 20-30 mm size BI01010001010000000000000515BI0100001222 1 M
111 111 "Supply, fabrication, installation & welding of sump on the bottom plate at lowest point. The sump shall be provided as per Drawing No. ENG/131 1/2. However the inner dia of the sump shall be 400 mm to enable insertion through shell manhole. Item includes supply of MS plates of required thickness conforming to IS 2062. The vertical weld of the sump neck is to be fully radiographed. Also the under side of the sump shall be applied with 3 coats of Shalimastic HD @ 200 Microns per coat aggregating 600 Microns after manual cleaning to SSPC SP2. BI01010001010000000000000515BI0100001223 1 LS
112 112 Supplying, fabricating, providing cover with mesh for central drain/emergency drain of FRVT as per B&R drawing BI01010001010000000000000515BI0100001224 1 EA
113 113 Providing 250mm dia free vent on roof including cutting, removing the roof plate, supplying 250mm dia MS pipes for free vent & its reinforcement plate, SS mesh as per drawing, bending/ shaping, welding, testing, clamps/nuts/bolts, as per B&R drgs. no. BR/CR/278-R1 and its connected drgs., painting as per IOC painting scheme, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001225
114 114 250mm dia free vent BI01010001010000000000000515BI0100001226 1 EA
115 115 Replacement of existing damaged mesh of free vents with new 2.5 stainless steel mesh including dismantling & removing the old mesh without any damage to the vent pipe, fixing the new mesh with necessary clamps, bolts, nuts as required etc., complete as per specification and instructions at site. BI01010001010000000000000515BI0100001227
116 116 150mm to 250nn dia free vents BI01010001010000000000000515BI0100001228 1 EA
117 117 Repainting the internal surface of roof nozzles/ manholes including removing the manhole covers and re-fixing the same without any damage to the existing structures, manual scrapping, supplying and painting etc., complete as per specification and instruction at site. BI01010001010000000000000515BI0100001229
118 118 Specification for surface preparation / cleaning / painting works; BI01010001010000000000000515BI0100001230
119 119 Clean to SSPC SP 2 hand cleaning wire brushing. BI01010001010000000000000515BI0100001231
120 120 One coat of Polyamide cured epoxy zinc phosphate primer (P2) with DFT in the range of 70-75 micron + BI01010001010000000000000515BI0100001232
121 121 Amine Adduct Cured HB epoxy liner (F3) with 2 coats of DFT in the range of 100-125 micron. BI01010001010000000000000515BI0100001233
122 122 Total DFT min 270 microns BI01010001010000000000000515BI0100001234
123 123 All roof nozzles/ manholes - Vertical Tank BI01010001010000000000000515BI0100001235 1 LS
124 124 Welding the pitted spot/surface in the bottom plate including cleaning, scrapping, welding built-up, gouging/grinding, supplying & welding patch plate without any damage to bottom plate, DP/vacuum box testing, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001236
125 125 150mm x 150mm to 300mm x 300mm size of 8mm MS plate BI01010001010000000000000515BI0100001237 1 EA
126 126 Supplying and providing patch plate on the existing bottom plate including vacuum box test, bending to required shape to fit-on to the existing sweating patch plate of bottom plate, chamfering the edges to seat properly on to the bottom plate, welding, conducting dye penetration test etc., complete as per specifications and instructions at site. BI01010001010000000000000515BI0100001238
127 127 150mm x 150mm to 300mm x 300mm - 8mm thick BI01010001010000000000000515BI0100001239 1 EA
128 128 400mm x 400mm to 600mm x 600mm - 8mm thick BI01010001010000000000000515BI0100001240 1 EA
129 129 Replacement of existing pad plate of angle cleat on pressure relief line on the shell plate on which sweating observed including gouging the pad plate, weld built & bring flush the gouged places, supplying & welding MS plate as required, as per specification and instructions at site. BI01010001010000000000000515BI0100001241
130 130 230mm x230mm x 5mm thick BI01010001010000000000000515BI0100001242 1 LS
131 131 Supplying, fabricating, laying and welding (3 runs min.) above ground pipelines including supplying IS 1239 Heavy grade MS ERW pipes, cutting, beveling and fixing the supplied specials such as elbows, bends, tees, reducers etc complete and hydro testing the pipelines at 10.5 KSC for a minimum period of 4 Hrs., supplying & providing MS structural supports as per B&R drgs, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001243
132 132 Note: Welding of pipeline should conform to Radiography quality. Any repairs to the defective welding shall be made good at no extra cost. Re radiography of repaired joint shall also be at contractor's cost. IOC painting scheme shall be followed. BI01010001010000000000000515BI0100001244
133 133 80 mm dia overflow pipeline BI01010001010000000000000515BI0100001245 1 M
134 134 Supplying & Welding the SORF flanges on the pipelines with 1 run inside and two runs outside, all leads & lifts etc., compete as per specifications and instructions at site. BI01010001010000000000000515BI0100001246
135 135 80 mm (3") dia BI01010001010000000000000515BI0100001247 1 EA
136 136 Making flanged joints for both slip on and blind flanges including supplying and fixing 3 mm thk non-metallic gaskets, studs/ nuts etc of approved make for the following sizes as per IOC specifications and site instructions. BI01010001010000000000000515BI0100001248
137 137 80 mm (3") dia BI01010001010000000000000515BI0100001249 1 EA
138 138 Supplying the following pipe fittings confirming to ASTM A 234 Gr WPB, Schedule 40, ANSI B 16.9 BI01010001010000000000000515BI0100001250
139 139 90 deg LR bend (1.5D) BI01010001010000000000000515BI0100001251
140 140 80 mm (3") dia BI01010001010000000000000515BI0100001252 1 EA
141 141 45 deg LR bend (1.5D) BI01010001010000000000000515BI0100001253
142 142 80 mm (3") dia BI01010001010000000000000515BI0100001254 1 EA
143 143 Carrying out vacuum box test for bottom plate welding including providing necessary vacuum box, tools/tackles, foam solutions etc., carrying out the test/ repeat test if required, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001255
144 144 Upto 10 M dia vertical tank BI01010001010000000000000515BI0100001256 1 SET
145 145 10 M to 16 M dia vertical tank BI01010001010000000000000515BI0100001257 1 SET
146 146 18 M to 24 M dia vertical tank BI01010001010000000000000515BI0100001258 1 SET
147 147 20 M to 32 M dia vertical tank BI01010001010000000000000515BI0100001259 1 SET
148 148 32 M to 40 M dia vertical tank BI01010001010000000000000515BI0100001260 1 SET
149 149 Carrying out Chalk-Kerosene test for the welding joint of bottom plate & shell plate including providing necessary kerosene/chalk, tools/tackles, etc., carrying out the test/ repeat test if required, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001261
150 150 Upto 10 M dia vertical tank BI01010001010000000000000515BI0100001262 1 LS
151 151 10 M to 16 M dia vertical tank BI01010001010000000000000515BI0100001263 1 SET
152 152 18 M to 24 M dia vertical tank BI01010001010000000000000515BI0100001264 1 SET
153 153 20 M to 32 M dia vertical tank BI01010001010000000000000515BI0100001265 1 SET
154 154 32 M to 40 M dia vertical tank BI01010001010000000000000515BI0100001266 1 SET
155 155 Conducting weld inspection of all weld joints on shell by wet Fluorescent Magnetic Particle with UV lamp including supervision by qualified inspector with ASNT level 2 certification. Note: Scaffolding will be paid separately. BI01010001010000000000000515BI0100001267
156 156 On shell plate of vertical tanks BI01010001010000000000000515BI0100001268 1 M
157 157 Carrying out Magnetic Flux Leakage test using Low Frequency Electromagnetic Technique (LFET) for the Bottom Plates including providing necessary equipments, tools/tackles, etc., carrying out the test/ repeat test if required, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001269
158 158 On Bottom plate of vertical tanks BI01010001010000000000000515BI0100001270 1 M2
159 159 Providing weld-deposition in the pitted spots on the bottom plate including cleaning thoroughly, building/ deposition the welding into the pitted spots, grinding smoothly without damage to the bottom plate, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001271
160 160 Per Spot (150mm x 150mm) BI01010001010000000000000515BI0100001272 1 LS
161 161 Providing 12mm dia holes (upto 10 holes) on the wind girder wherever required to drain the rain water stagnation without any damage to shell plate & web/flange plate of wind girder, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001273 1 LS
162 162 Providing 6mm dia holes (upto 3 holes per step) on the angle support of steps of spiral staircase & landing platforms to drain the rain water stagnation without any damage to shell plate & angle support, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001274 1 LS
163 163 Replacement of corroded (approx 50%) Weather Shields including dismantling, handing over, supplying & fixing new weather shield (GI) plates of same size(500X600X6) with new SS fittings etc., complete as per specification & instructions at site. BI01010001010000000000000515BI0100001275 1 M
164 164 Repairs to existing damaged roof structurals such as rafters, girders including providing temporary supports, providing derricks for dismantling, handling, lowering, cutting/dismantling of member joints, re-erection/re-connecting of the same to bring its original shape/position etc complete. Supply of additional roof structure element to replace damaged/twisted members will be paid separately. BI01010001010000000000000515BI0100001276 1 TON
165 165 Supply of roof structures such as rafters using ISMC 125x65, ISMC 150x75, ISMC175x75, Girders using ISMC 350x100, stair case, landing platform, platforms for foam pourers etc etc for replacing the damaged sections (if any) and provision of curb angle using ISA 100x100x10 including fabrication, erection, welding, painting the structures etc. complete. BI01010001010000000000000515BI0100001277 1 TON
166 166 Supplying and providing of 75mm dia Hatch on roof/gauge well of CRVT/FRVT using 80 mm dia nominal pipe welded with slip-on flange on top of it including supplying and providing reinforcing plate etc. complete as per our specifications and B&R drawing. BI01010001010000000000000515BI0100001278 1 EA
167 167 Supplying and providing of 100mm dia Hatch on roof of CRVT using 100 mm dia nominal pipe welded with slip-on flange on top of it including supplying and providing reinforcing plate etc. complete as per our specifications and B&R drawing. BI01010001010000000000000515BI0100001279 1 EA
168 168 220 MM dia gauge hatch with spark proof cover as per drg.no BR/CR/273,274,275,276 BI01010001010000000000000515BI0100001280 1 EA
169 169 gauge hatch 150 MM dia as per drg no BR/CR/273 to BR/FR/277 BI01010001010000000000000515BI0100001281 1 EA
170 170 All weld defects in Lap joints in Shell plates should be removed by fine grinding and re-welding to be carried out to ensure no further weld defects. Welding to be carried out using E6013 electrode BI01010001010000000000000515BI0100001282 1 M
171 171 Carrying out repairs of rolling ladder by welding of hinges to ladder structure at either end/or putting cotter pins, correcting alignment of rolling ladder steps by adjusting the link etc BI01010001010000000000000515BI0100001283 1 LS
172 172 Removing washer on One Side of rolling ladder wheel and fixing on other side and adjusting position of wheel so as to make it centric including providing temporary support to ladder etc as required. BI01010001010000000000000515BI0100001284 1 LS
173 173 Brass bars brazed to the rolling ladder wheels to be provided BI01010001010000000000000515BI0100001285 1 LS
174 174 Supply and providing proper copper bonding connection should be provided between the roof and rolling ladder with earthing wire cable of size 50mm SQ PVC insulated copper wire cable, including replacement of damaged lugs etc as required. BI01010001010000000000000515BI0100001286 1 M
175 175 Supply, fabrication, installation, welding, heat treatment if required including fabrication & fixing of cover plates of 6 mm thickness and 500 mm dia in roof manholes, etc. including preparation of drawings, supply of gases, electrodes and other consumables, supply and fixing of bolts, painting the same (external paiting system of tank), nuts and gaskets of approved make wherever required etc. and all labour material for completing the work as per drawings, codes / IOC specifications and site engineer's instructions (As per B&R drawing no. BR/CR/237 & 277) BI01010001010000000000000515BI0100001287
176 176 For Roof manholes BI01010001010000000000000515BI0100001288 1 EA
177 177 Supply & installation of MS Galvanized "U" clamp of size including providing M16 U-bolts with nuts suitable for the following size of pipeline; BI01010001010000000000000515BI0100001289
178 178 65mm dia BI01010001010000000000000515BI0100001290 1 EA
179 179 80mm dia BI01010001010000000000000515BI0100001291 1 EA
180 180 100mm dia BI01010001010000000000000515BI0100001292 1 EA
181 181 150mm dia BI01010001010000000000000515BI0100001293 1 EA
182 182 Supplying, providing, testing, painting 25 mm dia extension of expansion relief line for upto bottom of the tank as per drawing ref BR/CR/283 for CRVT. Item includes supplying and fixing of MS pipes (sch-80), necessary MS structural supports, pad paltes to shell as case may be for holding the pipe in position both inside the tank, providing siphon breaker (12 mm hole) on top most portion, testing the same hydrostatically at 10.5 kg/cm2, all leads & lifts etc., complete as per isntructions. BI01010001010000000000000515BI0100001294
183 183 Specification for surface preparation / cleaning / painting works; BI01010001010000000000000515BI0100001295
184 184 Clean to SSPC SP 2 hand cleaning wire brushing. BI01010001010000000000000515BI0100001296
185 185 One coat of Mastic Coating - P4 (175 µ) + BI01010001010000000000000515BI0100001297
186 186 Two coat of Acrylic Polyurethane - F1 (40-45 m each) BI01010001010000000000000515BI0100001298
187 187 Total DFT of 255 m BI01010001010000000000000515BI0100001299
188 188 25 mm dia expansion line BI01010001010000000000000515BI0100001300 1 M
189 189 Supply and installation of Pressure vacuum relief valves with pressure setting of 75 mm water column and vacuum setting of 25 mm water column including painting the same (external paiting system of valve) as per instructions. BI01010001010000000000000515BI0100001301
190 190 100 mm (4") dia BI01010001010000000000000515BI0100001302 1 EA
191 191 150 mm (4") dia BI01010001010000000000000515BI0100001303 1 EA
192 192 Only testing of PV valves BI01010001010000000000000515BI0100001304
193 193 100 mm (4") dia BI01010001010000000000000515BI0100001305 1 EA
194 194 150 mm (4") dia BI01010001010000000000000515BI0100001306 1 EA
195 195 Pontoons compartments to be tested with air pressure at 75 MM water column by sealing compartment joints on top and hatch & checking by means of soap water on all joints to ensure the pontoons are free from pinholes/ leakages/ seepage etc. before re-commissioning the tank. BI01010001010000000000000515BI0100001307
196 196 Upto 10 M dia vertical tank BI01010001010000000000000515BI0100001308 1 EA
197 197 10 M to 16 M dia vertical tank BI01010001010000000000000515BI0100001309 1 EA
198 198 18 M to 24 M dia vertical tank BI01010001010000000000000515BI0100001310 1 EA
199 199 20 M to 32 M dia vertical tank BI01010001010000000000000515BI0100001311 1 EA
200 200 32 M to 40 M dia vertical tank BI01010001010000000000000515BI0100001312 1 EA
201 201 Taking radiographs of tank weld joints (T joints/horizontal/vertical joint) using film size 4" x 8" or 3" x 12 " as required.\nRadiography inspection on tank joints of all types and thickness including providing all necessary equipment as per specifications and instruction of Site Engineer. The radiographs shall be submitted to the engineer in charge at site/ third party inspecting agency.\nRetaking of radiography due to defective welds/defective films/ defective workmanship etc. will be to contractor's account. Necessary scaffolding shall be paid extra. BI01010001010000000000000515BI0100001313 1 EA
202 202 Submission of radiographs to Third Party Inspection Agency(PDIL/BVIS/DNV/TUV) and getting evaluation report duly certified by qualified inspector(ASNT Level II) BI01010001010000000000000515BI0100001314 1 EA
203 203 Dismantling and removing the existing mechanical seal without any damage to shell plate/deck including weather shield, foam, seal cover, holding down bars, nuts/bolts, stacking the same safely, all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001315
204 204 For Floating Roof Vertical Tanks- Without Rim Seal Fire Protection System BI01010001010000000000000515BI0100001316 1 M
205 205 For Floating Roof Vertical Tanks - With Rim Seal Fire Protection System BI01010001010000000000000515BI0100001317 1 M
206 206 Re-fixing of dismantled mechanical seal without any damage to shell plate/deck safely including modification if any of the rim angle (by hot work, drilling and supply of material including rim angle, if required), all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001318
207 207 For Floating Roof Vertical Tanks- Without Rim Seal Fire Protection System BI01010001010000000000000515BI0100001319 1 M
208 208 For Floating Roof Vertical Tanks - With Rim Seal Fire Protection System BI01010001010000000000000515BI0100001320 1 M
209 209 Hydrostatic testing of MS pipeline complete as per IOC specification. Supply of sweet water will be paid separately as per item above BI01010001010000000000000515BI0100001321
210 210 a) upto 100 mm dia BI01010001010000000000000515BI0100001322 1 M
211 211 b) 150 mm dia BI01010001010000000000000515BI0100001323 1 M
212 212 c) 200 mm dia BI01010001010000000000000515BI0100001324 1 M
213 213 d) 250 mm dia BI01010001010000000000000515BI0100001325 1 M
214 214 e) 300 mm dia BI01010001010000000000000515BI0100001326 1 M
215 215 f) 350 mm dia BI01010001010000000000000515BI0100001327 1 M
216 216 g) 400 mm dia BI01010001010000000000000515BI0100001328 1 M
217 217 h) 450 mm dia BI01010001010000000000000515BI0100001329 1 M
218 218 Welding of pipeline & pipe fittings joints aboveground for manifold/TLF/pumphouse modification works BI01010001010000000000000515BI0100001330 1 Inch dia.
219 219 Conducting Dye penetration test on the new weld joints (shell to bottom plate, pad plates for roof supports, lower deck plate with leg sleeve, manhole neck, rolling ladder etc) after welding. BI01010001010000000000000515BI0100001331 1 M
220 220 Conducting pneumatic test of the nozzles/manholes by providing test arrangement including and consumable items for completion of this testing\nas per direction of IOCL. The scope of the work in this items is for single nozzles/ manholes irrespective of size. BI01010001010000000000000515BI0100001332 1 EA
221 221 Providing mud packing with clay for the pipelines while carrying out hotwork -\nfor 8" and above dia only BI01010001010000000000000515BI0100001333 1 EA
222 222 Post box type cutting, opening of the bottom most strake of tank shellfor a size of1.8 m length and width 0.2 m for taking the MS platesinside the tank. The cut plates may be used for closing the openingafter proper edge preparation including bevelling and welding withproper root gap. The work also includes 100% radiography of the weldjoints before taking water for deck floatation. NOTE: Cost inclusive o fall tools, tackles required for the job to complete to the\nentire satisfaction of Engineer in\ncharge." BI01010001010000000000000515BI0100001334 1 LS
223 223 Supply of earthing boss (MS round bar \nof 50 mm dia) and making ofinternal\nthread, fixing on tank shell and\ncarrying out continuouswelding. Work\nalso includes supply of 2 nos brass\nwashers, 1 no. 16 mmdia brass stud and\n1 no MS nut for fixing of earth strip\nto earth boss.Refer: Drg BR/FR/276A BI01010001010000000000000515BI0100001335 1 EA
224 224 Provision of lock down latch\narrangement for all the pontoon covers. \nThe work includes cutting,\nfabricating, welding of 5mm/6mm thk\nMSplates for supports, clip/cleats and\nsupply, bending, erection of 6 mmdia round steel rod and fixing, etc.\ncomplete as per the directions\nofEngineer in charge. NOTE: MS plates\nshall be supplied by IOC. Ref B&R\nDrg.BR/FR/268. BI01010001010000000000000515BI0100001336 1 EA
225 225 Cutting , removal of the \ndamaged/corroded existing curb angle\nfor about1 m on the tank and replacing \nwith new curb angle including\nsupply,rolling, fabrication of angle\nand welding, etc. complete as per\nthedirections of Engineer in charge. BI01010001010000000000000515BI0100001337 1 EA
226 226 Laying and welding (3 runs min.) above ground/ below ground pipelines from supplied MS pipes (pipes to be supplied anywhere within the depot and the contractor shall shift the same to the site of work at no extra cost with all leads and lifts) of the following sizes including cutting, beveling, positioning, setting, welding, fixing the supplied specials such as elbows, bends tees, reducers etc., complete and hydro testing the pipelines at 10.5 KSC for a minimum period of 4 Hrs. The job includes blast cleaning & painting of the outer surfaces of above ground pipeline/ fittings/ specials/ flanges/ blind flanges, all leads & lifts etc., complete as per specifications and instructions at site. BI01010001010000000000000515BI0100001338
227 227 Note: a) The primer and paint shall be as per the list of paint manufacturers enclosed. The make and quality of paint shall be decided in consultation with IOC prior to use. b) Pipeline colour coding shall be carried out as per IOC specifications at no extra cost for product piping. c) Successful tenderer shall prepare the complete pipeline routing, wherever required and get the same approved prior to execution of works. BI01010001010000000000000515BI0100001339
228 228 Above ground pipeline to be laid on concrete pedestals (which is to be constructed as per the respective item of this schedule) and painting & colour coding the pipeline as per the specifications. Welding of pipeline should conform to Radiography quality. 10% of the joints shall be radiograped and the cost of the same will be paid separately as per respective item, all leads & lifts etc., complete as per specifications and instructions at site. BI01010001010000000000000515BI0100001340
229 229 Note: a) Any repairs to the defective welding shall be made good at no extra cost. Re-radiography of repaired joint shall also be at contractor's cost. b) The rates quoted also to include colour coding of pipelines as per the standards. c) The rate shall include providing temporary / moving screen wall for local welding of running pipelines, if required. BI01010001010000000000000515BI0100001341
230 230 d) Painting scheme for MS pipeline (A/G)/ fittings/ specials/ flanges: BI01010001010000000000000515BI0100001342
231 231 Specification for surface preparation / cleaning / painting works; BI01010001010000000000000515BI0100001343
232 232 Surface Preparation : Blast clean to SA 2 1/2 BI01010001010000000000000515BI0100001344
233 233 Primer : Inorganic Zinc Ethyl Silicate (P1) with DFT in the range of 65-75 micron. BI01010001010000000000000515BI0100001345
234 234 Intermediate Coat : Polyamide cured HB Epoxy MIO (U1) with DFT in the range of 100 -125 micron. BI01010001010000000000000515BI0100001346
235 235 Finish Coat : Two Pack Acrylic Poly-urethane(PU) (F1) with DFT in the range of 40-50 micron. BI01010001010000000000000515BI0100001347
236 236 TOTAL min DFT 215 microns BI01010001010000000000000515BI0100001348
237 237 25 mm dia including cost of SCH-80 pipe BI01010001010000000000000515BI0100001349 1 M
238 238 50 mm dia including cost of SCH-80 pipe BI01010001010000000000000515BI0100001350 1 M
239 239 80 mm dia BI01010001010000000000000515BI0100001351 1 M
240 240 100 mm dia BI01010001010000000000000515BI0100001352 1 M
241 241 150 mm dia BI01010001010000000000000515BI0100001353 1 M
242 242 200 mm dia BI01010001010000000000000515BI0100001354 1 M
243 243 250 mm dia BI01010001010000000000000515BI0100001355 1 M
244 244 300 mm dia BI01010001010000000000000515BI0100001356 1 M
245 245 350 mm dia BI01010001010000000000000515BI0100001357 1 M
246 246 400 mm dia BI01010001010000000000000515BI0100001358 1 M
247 247 450 mm dia BI01010001010000000000000515BI0100001359 1 M
248 248 Provision of Saddle plates for Product & Hydrant Pipelines over pedestals including cutting and fabrication of saddle plates from supplied MS pipes and welding of the same on pipelines under pedestals with minimum 3 run of welding complete as per specifications, drawings and directions of Engineer in charge. BI01010001010000000000000515BI0100001360
249 249 450 mm dia pipe BI01010001010000000000000515BI0100001361 1 EA
250 250 400 mm dia pipe BI01010001010000000000000515BI0100001362 1 EA
251 251 350 mm dia pipe BI01010001010000000000000515BI0100001363 1 EA
252 252 300 mm dia Pipe BI01010001010000000000000515BI0100001364 1 EA
253 253 250 mm dia pipe BI01010001010000000000000515BI0100001365 1 EA
254 254 200 mm dia pipe BI01010001010000000000000515BI0100001366 1 EA
255 255 150 mm dia pipe BI01010001010000000000000515BI0100001367 1 EA
256 256 100 mm dia pipe BI01010001010000000000000515BI0100001368 1 EA
257 257 80 mm dia pipe BI01010001010000000000000515BI0100001369 1 EA
258 258 Underground pipelines to be laid at a depth as per site condition/ laying through hume pipes/ culverts of the following sizes including supplying & providing doping (wrapping & coating), all leads & lifts etc., complete as per specifications and instructions at site. BI01010001010000000000000515BI0100001370
259 259 Note : a) Welding of pipeline should be to Radiography quality. 10% of the joints shall be radiograped and the cost of the same will be paid separately as per respective item etc. b) All job as stated above for erection of under ground pipeline shall be included in the quoted rate except payment of radiography. BI01010001010000000000000515BI0100001371
260 260 b) Wrapping & coating of MS pipeline (U/G)/ fittings/ specials/ flanges with approved materials as per specifications. BI01010001010000000000000515BI0100001372
261 261 25 mm dia including cost of SCH-80 pipe BI01010001010000000000000515BI0100001373 1 M
262 262 50 mm dia including cost of SCH-80 pipe BI01010001010000000000000515BI0100001374 1 M
263 263 80 mm dia BI01010001010000000000000515BI0100001375 1 M
264 264 100 mm dia BI01010001010000000000000515BI0100001376 1 M
265 265 150 mm dia BI01010001010000000000000515BI0100001377 1 M
266 266 200 mm dia BI01010001010000000000000515BI0100001378 1 M
267 267 250 mm dia BI01010001010000000000000515BI0100001379 1 M
268 268 300 mm dia BI01010001010000000000000515BI0100001380 1 M
269 269 350 mm dia BI01010001010000000000000515BI0100001381 1 M
270 270 400 mm dia BI01010001010000000000000515BI0100001382 1 M
271 271 450 mm dia BI01010001010000000000000515BI0100001383 1 M
272 272 Radiography inspection on product pipe joints of all types and thickness of the following sizes including providing all necessary equipment required to perform the work as per our specification and of our site engineer. The radiographs shall be submitted to the the engineer in charge at site/ third party inspecting agency. BI01010001010000000000000515BI0100001384
273 273 Note: Re-taking of radiography due to defective welds/ defective films/ defective workmanship etc., will be to contractor's cost. BI01010001010000000000000515BI0100001385
274 274 50 mm dia BI01010001010000000000000515BI0100001386 1 EA
275 275 80 mm dia BI01010001010000000000000515BI0100001387 1 EA
276 276 100 mm dia BI01010001010000000000000515BI0100001388 1 EA
277 277 150 mm dia BI01010001010000000000000515BI0100001389 1 EA
278 278 200 mm dia BI01010001010000000000000515BI0100001390 1 EA
279 279 250 mm dia BI01010001010000000000000515BI0100001391 1 EA
280 280 300 mm dia BI01010001010000000000000515BI0100001392 1 EA
281 281 350 mm dia BI01010001010000000000000515BI0100001393 1 EA
282 282 400 mm dia BI01010001010000000000000515BI0100001394 1 EA
283 283 450 mm dia BI01010001010000000000000515BI0100001395 1 EA
284 284 Welding of the supplied WNRF/SORF flanges of the following sizes on the pipelines including setting, positioning, setting, welding with min. three runs outside and one run inside (SORF), all leads & lifts etc., complete as per specifications and instructions at site. BI01010001010000000000000515BI0100001396
285 285 50 mm dia BI01010001010000000000000515BI0100001397 1 EA
286 286 80 mm dia BI01010001010000000000000515BI0100001398 1 EA
287 287 100 mm dia BI01010001010000000000000515BI0100001399 1 EA
288 288 150 mm dia BI01010001010000000000000515BI0100001400 1 EA
289 289 200 mm dia BI01010001010000000000000515BI0100001401 1 EA
290 290 250 mm dia BI01010001010000000000000515BI0100001402 1 EA
291 291 300 mm dia BI01010001010000000000000515BI0100001403 1 EA
292 292 350 mm dia BI01010001010000000000000515BI0100001404 1 EA
293 293 400 mm dia BI01010001010000000000000515BI0100001405 1 EA
294 294 450 mm dia BI01010001010000000000000515BI0100001406 1 EA
295 295 Supply & welding slip on flanges conforming to IS2062 GrA, ANSI B16.5- Class # 150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg. enclosed herein. BI01010001010000000000000515BI0100001407
296 296 50 mm dia BI01010001010000000000000515BI0100001408 1 EA
297 297 80 mm dia BI01010001010000000000000515BI0100001409 1 EA
298 298 100 mm dia BI01010001010000000000000515BI0100001410 1 EA
299 299 150 mm dia BI01010001010000000000000515BI0100001411 1 EA
300 300 200 mm dia BI01010001010000000000000515BI0100001412 1 EA
301 301 250 mm dia BI01010001010000000000000515BI0100001413 1 EA
302 302 300 mm dia BI01010001010000000000000515BI0100001414 1 EA
303 303 350 mm dia BI01010001010000000000000515BI0100001415 1 EA
304 304 400 mm dia BI01010001010000000000000515BI0100001416 1 EA
305 305 450 mm dia BI01010001010000000000000515BI0100001417 1 EA
306 306 Making flanged joints between flanges slip on and blind flange including supplying and fixing 3 mm thick non metallic gaskets, nuts, bolts of approved make for the following sizes, as per IOCL specifications and site instructions. The flange joint shall also include providing and fixing multistrand copper wire/flat for bonding of product pipelines including provision of lugs.\n BI01010001010000000000000515BI0100001418
307 307 50 mm dia BI01010001010000000000000515BI0100001419 1 EA
308 308 80 mm dia BI01010001010000000000000515BI0100001420 1 EA
309 309 100 mm dia BI01010001010000000000000515BI0100001421 1 EA
310 310 150 mm dia BI01010001010000000000000515BI0100001422 1 EA
311 311 200 mm dia BI01010001010000000000000515BI0100001423 1 EA
312 312 250 mm dia BI01010001010000000000000515BI0100001424 1 EA
313 313 300 mm dia BI01010001010000000000000515BI0100001425 1 EA
314 314 350 mm dia BI01010001010000000000000515BI0100001426 1 EA
315 315 400 mm dia BI01010001010000000000000515BI0100001427 1 EA
316 316 450 mm dia BI01010001010000000000000515BI0100001428 1 EA
317 317 Making flanged joints between flanges (WNRF/SORF/BLRF) including supplying and fixing 3 mm thick SW SS gaskets with graphite fillers, studs, nuts, bolts of approved make for the following sizes, as per IOCL specifications and site instructions. The flange joint shall also include providing and fixing multistrand copper wire/flat for bonding of product pipelines including\nprovision of lugs. BI01010001010000000000000515BI0100001429
318 318 600 mm dia BI01010001010000000000000515BI0100001430 1 EA
319 319 500 mm dia BI01010001010000000000000515BI0100001431 1 EA
320 320 450 mm dia BI01010001010000000000000515BI0100001432 1 EA
321 321 400 mm dia BI01010001010000000000000515BI0100001433 1 EA
322 322 350 mm dia BI01010001010000000000000515BI0100001434 1 EA
323 323 300 mm dia BI01010001010000000000000515BI0100001435 1 EA
324 324 250 mm dia BI01010001010000000000000515BI0100001436 1 EA
325 325 200 mm dia BI01010001010000000000000515BI0100001437 1 EA
326 326 150 mm dia BI01010001010000000000000515BI0100001438 1 EA
327 327 100 mm dia BI01010001010000000000000515BI0100001439 1 EA
328 328 80 mm dia BI01010001010000000000000515BI0100001440 1 EA
329 329 Making flanged joints between flanges (WNRF/SORF/BLRF) including supplying and fixing 3 mm thk PTFE gaskets, studs/ nuts etc. of approved make for the following sizes as per IOC specifications and site instructions. The flange joints shall also include providing and fixing multistrand copper strip/flat for bonding of product pipelines , Cost of strand/ GI flat shall be paid separately as per rate in RM.\n(for Ethanol) BI01010001010000000000000515BI0100001441
330 330 300 mm dia BI01010001010000000000000515BI0100001442 1 EA
331 331 250 mm dia BI01010001010000000000000515BI0100001443 1 EA
332 332 200 mm dia BI01010001010000000000000515BI0100001444 1 EA
333 333 150 mm dia BI01010001010000000000000515BI0100001445 1 EA
334 334 100 mm dia BI01010001010000000000000515BI0100001446 1 EA
335 335 80 mm dia BI01010001010000000000000515BI0100001447 1 EA
336 336 50 mm dia BI01010001010000000000000515BI0100001448 1 EA
337 337 25 mm dia BI01010001010000000000000515BI0100001449 1 EA
338 338 Fixing the supplied CS GATE/ ROSOV/ DBBV/ MOV/ GOV/ NRV/ BALL/ BUTTERFLY/ AUDCO valves of the following sizes on the pipeline including supplying and fixing 3 mm thk non metallic gaskets, studs/nuts etc of approved make for the following sizes as per specifications, existing cable termination wherever required, all lead & lifts, transportation etc., complete and as per instructions at site. BI01010001010000000000000515BI0100001450
339 339 Note: a) Painting with approved make, colour, shade including colour coding as per specifications. BI01010001010000000000000515BI0100001451
340 340 b) Painting scheme for accessories & valves: BI01010001010000000000000515BI0100001452
341 341 Specification for surface preparation / cleaning / painting works; BI01010001010000000000000515BI0100001453
342 342 Clean to SSPC SP 2 hand cleaning wire brushing. BI01010001010000000000000515BI0100001454
343 343 Two coats of P3 (30-35 m each) + BI01010001010000000000000515BI0100001455
344 344 Two coats of F4 (25 m each) BI01010001010000000000000515BI0100001456
345 345 Total DFT of 110 m BI01010001010000000000000515BI0100001457
346 346 50 mm dia BI01010001010000000000000515BI0100001458 1 EA
347 347 80 mm dia BI01010001010000000000000515BI0100001459 1 EA
348 348 100 mm dia BI01010001010000000000000515BI0100001460 1 EA
349 349 150 mm dia BI01010001010000000000000515BI0100001461 1 EA
350 350 200 mm dia BI01010001010000000000000515BI0100001462 1 EA
351 351 250 mm dia BI01010001010000000000000515BI0100001463 1 EA
352 352 300 mm dia BI01010001010000000000000515BI0100001464 1 EA
353 353 350 mm dia BI01010001010000000000000515BI0100001465 1 EA
354 354 400 mm dia BI01010001010000000000000515BI0100001466 1 EA
355 355 450 mm dia BI01010001010000000000000515BI0100001467 1 EA
356 356 Fixing the following sized (Dia)\nsupplied spectacle dummy, with bothside\nnew gaskets, bolts, nuts etc. BI01010001010000000000000515BI0100001468
357 357 500 mm dia BI01010001010000000000000515BI0100001469 1 EA
358 358 450 mm dia BI01010001010000000000000515BI0100001470 1 EA
359 359 400 mm dia BI01010001010000000000000515BI0100001471 1 EA
360 360 350 mm dia BI01010001010000000000000515BI0100001472 1 EA
361 361 300 mm dia BI01010001010000000000000515BI0100001473 1 EA
362 362 250 mm dia BI01010001010000000000000515BI0100001474 1 EA
363 363 200 mm dia BI01010001010000000000000515BI0100001475 1 EA
364 364 150 mm dia BI01010001010000000000000515BI0100001476 1 EA
365 365 100 mm dia BI01010001010000000000000515BI0100001477 1 EA
366 366 80 mm dia BI01010001010000000000000515BI0100001478 1 EA
367 367 Cold cutting of the following sized\nunderground/ Above ground pipelines BI01010001010000000000000515BI0100001479
368 368 500 mm dia BI01010001010000000000000515BI0100001480 1 EA
369 369 450 mm dia BI01010001010000000000000515BI0100001481 1 EA
370 370 400 mm dia BI01010001010000000000000515BI0100001482 1 EA
371 371 350 mm dia BI01010001010000000000000515BI0100001483 1 EA
372 372 300 mm dia BI01010001010000000000000515BI0100001484 1 EA
373 373 250 mm dia BI01010001010000000000000515BI0100001485 1 EA
374 374 200 mm dia BI01010001010000000000000515BI0100001486 1 EA
375 375 150 mm dia BI01010001010000000000000515BI0100001487 1 EA
376 376 100 mm dia BI01010001010000000000000515BI0100001488 1 EA
377 377 80 mm dia BI01010001010000000000000515BI0100001489 1 EA
378 378 Pressure testing of Following sized\n(Dia)Valves . Both Gate & EntireValve\ncasing shall be subjected to pressure\nby providing blinding usingDummy,\nBolts/Nuts/Gaskets, tec BI01010001010000000000000515BI0100001490
379 379 500 mm dia BI01010001010000000000000515BI0100001491 1 EA
380 380 450 mm dia BI01010001010000000000000515BI0100001492 1 EA
381 381 400 mm dia BI01010001010000000000000515BI0100001493 1 EA
382 382 350 mm dia BI01010001010000000000000515BI0100001494 1 EA
383 383 300 mm dia BI01010001010000000000000515BI0100001495 1 EA
384 384 250 mm dia BI01010001010000000000000515BI0100001496 1 EA
385 385 200 mm dia BI01010001010000000000000515BI0100001497 1 EA
386 386 150 mm dia BI01010001010000000000000515BI0100001498 1 EA
387 387 100 mm dia BI01010001010000000000000515BI0100001499 1 EA
388 388 80 mm dia BI01010001010000000000000515BI0100001500 1 EA
389 389 Installing the supplied auto recirculation valves as per specifications on the product pump headers at the TLF pump house including supplying, providing and welding flanges of matching sizes.\nNote:\na. The job includes mechanical cleaning of valves and painting of the valves with 2 coats of P3 primer and 2 coats F4 finish paint of approved colour and shade as per the directions of site in charge. The job includes providing and fixing impulse as per manufacturer's recommendations.\nb. Bonding of the valves shall be done using multistrand copper wire/flat for bonding of product pipelines including provision of lugs. BI01010001010000000000000515BI0100001501
390 390 100 mm dia (suitable for 2400 - 4800 LPM - MS/ SKO/ HSD TLF\npumps) BI01010001010000000000000515BI0100001502 1 EA
391 391 80 mm dia (suitable for 900 - 1800 LPM - MS/ SKO/ HSD TLF pumps) BI01010001010000000000000515BI0100001503 1 EA
392 392 Installing the supplied bucket type (100 mesh) strainers as per specs and drawing for the product pumps for the following LPM & pipeline sizes:\nNote: The strainers shall be cleaned and painted with 2 coats of P3 primer and 2 coats of F4 finish paint of approved colour and shade etc as per the directions of the site engineer & the rates quoted should include the same. BI01010001010000000000000515BI0100001504
393 393 300 mm dia (Bucket type) BI01010001010000000000000515BI0100001505 1 EA
394 394 250 mm dia (Bucket type) BI01010001010000000000000515BI0100001506 1 EA
395 395 200 mm dia (Bucket type) BI01010001010000000000000515BI0100001507 1 EA
396 396 150 mm dia (Bucket type) BI01010001010000000000000515BI0100001508 1 EA
397 397 100 mm dia (Bucket type) BI01010001010000000000000515BI0100001509 1 EA
398 398 Installing the supplied Y type (40 mesh) strainers as per specs and drawing for the hydrant / water piping system including fire water pumps & sprinkler/foam headers for the following LPM & pipeline sizes:\nNote: The strainers shall be cleaned and painted with 2 coats of P3 primer and 2 coats of F4 finish paint of approved colour and shade etc as per the directions of the site engineer & the rates quoted should include the same. BI01010001010000000000000515BI0100001510
399 399 300 mm (Y type) & flowrate 616KL/HR BI01010001010000000000000515BI0100001511 1 EA
400 400 250 mm (Y type) & flowrate 410KL/HR BI01010001010000000000000515BI0100001512 1 EA
401 401 150 mm (Y type) & flowrate 2400 LPM BI01010001010000000000000515BI0100001513 1 EA
402 402 100 mm (Y type) & flowrate 1500 LPM BI01010001010000000000000515BI0100001514 1 EA
403 403 Installing the supplied thermal relief valves for the product pipeline and fixing the same on the pump discharge lines to TLF including painting the valves and connected piping with 2 coats of P3 primer and 2 coats of F4 finish paint of approved colour and shade as per the directions of site engineer.\nNote:\na. The 20/ 25 mm dia piping connected to the TRVs shall be measured and paid separatey under respective items.\nb. The job also includes providing and fixing 8SWG copper wire for the flange joints of the assembly. BI01010001010000000000000515BI0100001515 1 EA
404 404 Dismantling of the power driven product pumpsets installaed at IOC Premises without causing damage to pumpsets and its accessories. Item includes disconnection of pipeline, removing of electrical cables, foundation bolt, Handling & Placing at suitable place as per instrcutions.\nNote: The pumpsets shall be kept anywhere within the premises. The cost of foundation dismantling if required shall\nbe measured & paid separately under respective civil items. BI01010001010000000000000515BI0100001516
405 405 600 LPM X 30-50 M Head (Submersible Turbine Pump)\n BI01010001010000000000000515BI0100001517 1 EA
406 406 1200 LPM X 30-50 M Head (Submersible Turbine Pump)\n BI01010001010000000000000515BI0100001518 1 EA
407 407 6000 LPM X 30-60 M Head (OCF Pump) BI01010001010000000000000515BI0100001519 1 EA
408 408 4800 LPM X 30-60 M Head (OCF Pump) BI01010001010000000000000515BI0100001520 1 EA
409 409 3600 LPM X 30-60 M Head (OCF Pump) BI01010001010000000000000515BI0100001521 1 EA
410 410 2400 LPM X 30-60 M Head (OCF Pump) BI01010001010000000000000515BI0100001522 1 EA
411 411 1800 LPM X 30-40 M Head (OCF Pump) BI01010001010000000000000515BI0100001523 1 EA
412 412 1200 LPM X 20-40 M Head (OCF Pump) BI01010001010000000000000515BI0100001524 1 EA
413 413 900 LPM X 20-40 M Head (OCF Pump) BI01010001010000000000000515BI0100001525 1 EA
414 414 Mounting, installing, aligning, testing and commissioning of the power driven product pumpsets supplied by IOC without causing damage to pumpsets and its accessories. Pumpsets shall be erected and aligned as per manufacturer's drawings.\nNote: The pumpsets shall be supplied anywhere within the premises and the contractor shall undertake to lead the same to the foundations at no extra cost. The cost of foundation shall\nbe measured & paid separately under respective civil items. BI01010001010000000000000515BI0100001526
415 415 600 LPM X 30-50 M Head (Submersible Turbine Pump)\nNote: The pumpsets shall be erected with all accessories on UG tank manhole plates as per manufacturer's recommendations BI01010001010000000000000515BI0100001527 1 EA
416 416 1200 LPM X 30-50 M Head (Submersible Turbine Pump)\nNote: The pumpsets shall be erected with all accessories on UG tank manhole plates as per manufacturer's recommendations BI01010001010000000000000515BI0100001528 1 EA
417 417 6000 LPM X 30-60 M Head (OCF Pump) BI01010001010000000000000515BI0100001529 1 EA
418 418 4800 LPM X 30-60 M Head (OCF Pump) BI01010001010000000000000515BI0100001530 1 EA
419 419 3600 LPM X 30-60 M Head (OCF Pump) BI01010001010000000000000515BI0100001531 1 EA
420 420 2400 LPM X 30-60 M Head (OCF Pump) BI01010001010000000000000515BI0100001532 1 EA
421 421 1800 LPM X 30-40 M Head (OCF Pump) BI01010001010000000000000515BI0100001533 1 EA
422 422 1200 LPM X 20-40 M Head (OCF Pump) BI01010001010000000000000515BI0100001534 1 EA
423 423 900 LPM X 20-40 M Head (OCF Pump) BI01010001010000000000000515BI0100001535 1 EA
424 424 Installation of the supplied diesel engine driven fire pumpsets mounted on common base frame on foundations including grouting of supplied foundation bolts without causing damage to the pumps\n/ foundation & accessories. The pumpset (fire engines) shall be installed including supplying and providing AVM pads, grouting the foundation bolts into the the pockets provided in the foundation and aligning the pumpset etc. complete as per directions of site in charge.\nNote: a. The job includes transportation of fire engines from any location inside the Terminal / Installation / Depot premises to the Fire Water Pumphouse at no extra cost.\nb. The item rate quoted should also include cooling water piping with fittings etc complete.\nc. Civil works for foundation will be paid separately Fire Pumpset Size : 616 Cum/ Hr X 105 M head. BI01010001010000000000000515BI0100001536 1 EA
425 425 Installation of the supplied diesel engine driven fire pumpsets mounted on common base frame on foundations including grouting of supplied foundation bolts without causing damage to the pumps\n/ foundation & accessories. The pumpset (fire engines) shall be installed including supplying and providing AVM pads, grouting the foundation bolts into the the pockets provided in the foundation and aligning the pumpset etc. complete as per directions of site in charge.\nNote: a. The job includes transportation of fire engines from any location inside the Terminal / Installation / Depot premises to the Fire Water Pumphouse at no extra cost.\nb. The item rate quoted should also include cooling water piping with fittings etc complete.\nc. Civil works for foundation will be paid separately. Fire Pumpset Size : 410 Cum/ Hr X 88 M head. BI01010001010000000000000515BI0100001537 1 EA
426 426 Installation of supplied fuel tanks on MS structural supports including supplying and providing medium duty MS lines for supply and return lines to the fire pump from the fuel tank. The MS structural supports for fuel tank shall be blast cleaned to SA 2 1/2 and painting with two coats of P3 primer and two coats of F4 finish paint of approved colour & shade as per enclosed specifications and as per directions of site in charge\nNote : The item rate should include MS structural supports for the above job. Tenderers to note that fuel tanks shall be located such as to provide for gravity flow for fuel to the fire pumps. BI01010001010000000000000515BI0100001538 1 EA
427 427 Installing the supplied starter/ auto starter assembly of the fire pumps including supplying and erecting the same on ISA 65 x 6 including necessary CC support pillars, blast cleaning of the structures to SA 2 1/2 and painting the structure with two coats of P3 primer and F4 finished paint as per enclosed specification and as per directions of site in charge BI01010001010000000000000515BI0100001539 1 EA
428 428 Supplying and fixing battery stand using ISA 65 x 6 MS angle iron supports with necessary foundation including providing teak wood plank 20 mm thk for positioning 2x12 V batteries & connecting the same with starter/auto starter assembly / rechargers etc. complete Note: The structurals shall be mechanical cleaned and painted with 2 coats of P3 primer and 2 coats of F4 finish paint of approved colour and shade as per site directions. BI01010001010000000000000515BI0100001540 1 EA
429 429 Supplying, fabricating, welding, erecting with suitable supports 150 mm dia medium duty MS ERW tube as per IS 1239 for exhaust line of fire pumps including installing and erecting the supplied metalic bellows and silencer; the exhaust pipe shall be adequately supported in the fire pump house with suitable arrangements; the entire exhaust pipe shall be lagged using 12 mm dia asbestos rope and cladding the line in 22 g aluminium sheet with necessary riveting and fixing;\nThe exhaust pipe outside the fire pump house shall be taken to a minimum height of 3 mtrs. above the roof and supported by means of suitable brackets / guy wires / angle support; The exhaust shall also be provided with suitable arrangements so as to prevent water from entering the pipes. The entire work arrangement shall be completed as per specifications and directions of site in charge.\nNote: a. The asbestos rope shall be as per IS supplied by M/s.\nChampion/ M/s. Hindustan Composites. B. The\napproximate length of 150 mm dia line shall be 15 m per set c. The exhaust line after the silencer shall be painted with 2 coats of primer and two coats of heat resistant aluminium paint and the rates quoted to include the same. BI01010001010000000000000515BI0100001541 1 EA
430 430 Supplying and fixing electric pressure switches of approved make and connecting the same to the delivery headers of the Jockey pumps and Main hydrant pumps with necessary sockets welded on the headers, accessories etc complete. BI01010001010000000000000515BI0100001542 1 EA
431 431 Supplying and fixing 150 mm dia pressure gage (0-20 KSC) to the delivery lines of fire pumps, jockey pumps & hydrant network, including supplying and welding necessary sockets on the pipelines including 3 way pressure differential valve, etc. complete and as per directions of site in charge. BI01010001010000000000000515BI0100001543 1 EA
432 432 Interconnection between the starter panels of Fire pumps/ Jockey pumps/ make up water pumps/ pressure switches and Annunciation panel for auto starting of the fire pumps/ jockey pumps as per the logic defined in enclosed documents.; Entire interconnections shall be established using 2 C, 1.1 KV grade armoured copper cable of size\n1.5 sqmm;The cable shall be laid at all places including clamping etc complete as required; The job shall be complete in all respects and specifications as per the logic and requirements to put the entire system in AUTO mode as per the specifications.\nNote: Tenderers to note that all cabling to be taken underneath flooring of fire pump house shall be adequately protected by suitable sized B class GI piping. Also all cables to be laid above ground shall be neatly dressed and tagged. BI01010001010000000000000515BI0100001544 1 EA
433 433 Fixing the supplied FH line fittings on the Fire hydrant pipelines including supplying and fixing 3mm thick gaskets/ nuts/ studs and all other materials as per enclosed specifications and as directed at site.\nNote: The fittings shall be painted with two coats of F4 finish paint of approved colour and shade over 2 coats of P3 primer. The rates quoted should include the same. BI01010001010000000000000515BI0100001545
434 434 Double hydrant Points with individual control valves BI01010001010000000000000515BI0100001546 1 EA
435 435 100 mm Water / Water cum Foam Monitors BI01010001010000000000000515BI0100001547 1 EA
436 436 150 mm dia long range water cum foam monitors (500-750 GPM\nmanual HVLR) BI01010001010000000000000515BI0100001548 1 EA
437 437 Installation of IOCL supplied Remote operated High volume Long Range Water Monitors including the following :\n(a) Erection of Motors\n(b) Fixing of Proximity sensors\n(c) Erection of MOV Gate valve\n(d) Erection of Remote Control Panel\n(e) Fixing of Control & Junction Box\n(f) Laying of power cable from Control Panel to HVLR Motors\n(g) Laying of Control cable from Remote Control Panel to HVLR Signal Junction Box\n(h) Laying of Signal cable from Remote Control Panel to HVLR Signal Junction Box\n(i) Supply and Fixing of cable tray from Remote Control Panel to HVLR Junction Box\n(j) Glanding & termination of power , control & signal cables\n(k) Installation of Gaskets & stud bolts. as directed by IOCL or EIC\n(l) Making the stub connection with necessary reinforcement pad as applicable,\n(m) Suppiled foam container for HVLRM including erecting the same with necessary CC support as per specification and direction of site incharge.\n(n) Installation of suppiled Jet Ratio Control Pump(JRCP) for HVLRM including erecting the same with necessary CC support as per specification and direction of site incharge.\nNote:\na)The job also include the MS fabricated working platform wherever required without any extra cost. BI01010001010000000000000515BI0100001549 1 EA
438 438 Installation of suppiled control panel assembly with necessary canopy of the HVLRM including supply and erecting the same on ISA 65 x 6 including necessary CC support pillars, painting as per IOCL specifications and directions of site in charge. BI01010001010000000000000515BI0100001550 1 EA
439 439 Supplying and providing MS structural supports in ISA 65 X 6 for hose boxes supplied by IOC including cutting and welding and providing necessary CC 1:2:4 support pillars for the structures. The job also includes blast cleaning of the structures to SA 2 1/2 and painting with two coats of P3 primer and two coats of F4 finish paint as per specifications and as per colour and shade as directed by site in charge.\nNote : The stand shall be fixed with hose box at levels as indicated on drawings. BI01010001010000000000000515BI0100001551 1 EA
440 440 Installing, aligning testing and commissioning of the supplied jockey pump set of capacity 18.5 -100 Cum/hr x 110 m Head for fire hydrant automation; the job includes grouting foundation bolts in the pockets of the foundatoion etc complete.\nNote:\n1.The job also includes connecting the jockey pump to its control panel by a 3 C, 1.1 KV grade armoured aluminium cable of required size including necessary glanding/ gland\nearthing etc complete. (approximate length of cable not to exceed 25 m). Item rate quoted should include the same.\n2. Foundation shall be paid for separately as per the measurement under respective civil items. BI01010001010000000000000515BI0100001552 1 EA
441 441 Drain Pan arrangement for Product Pump / Fire Water Pump /\nJockey Pump BI01010001010000000000000515BI0100001553 1 EA
442 442 Installation, aligning and commissioing of make up water pump / calibration tower pump to be erected on the RCC slab of the UG water sump on suitable foundation inlcuding foundation bolts/ grouting etc.\nNote:\n1. The foundation and foundation bolts/ grouting shall be measured and paid separately under respective civil items. The pumps shall be connected to the starter to be located on gantry of calibration tower by a 3 1/2 C, 1.1 KV grade armoured Al. cable (approx. 40 m) of adequate rating including glanding/ gland earthing at both ends etc complete\n2. Suitable protection in MS angle frame work/ sheet steel for the pumps shall also be provided. The rates quoted to include the same. Capacity of Make up Water Pump (90 Cum/ Hr X 36 m head) BI01010001010000000000000515BI0100001554 1 EA
443 443 SUPPLY OF MATERIALS TO SITE BI01010001010000000000000515BI0100001555
444 444 Note: 1. All items under this section shall be quoted for supply to site including unloading. Third party inspection for the supply items shall be in tenderer's scope. Approval of TPI agency shall be obtained from IOCL on award of contract & engaged for inspection & clearance of all materials as per agreed QAP to be firmed up after placement of order by the Corporation. BI01010001010000000000000515BI0100001556
445 445 Supply of Mild Steel Plates of suitable width and length ranging in thickness from 5 mm to 28 mm as required, conforming to IS 2062 Gr. 'B' / IS 2062 E250B, Fully Killed (Un-trimmed and un-normalized condition of approved make). Rate should also include cost of inspection by IOCL approved 3rd Party inspection agency as listed elsewhere in the tender document. BI01010001010000000000000515BI0100001557 1 MT
446 446 Supply of pipes BI01010001010000000000000515BI0100001558
447 447 Sch 40, B 36.10, ASTM A106 Gr B Seamless BI01010001010000000000000515BI0100001559
448 448 25 mm dia BI01010001010000000000000515BI0100001560 1 M
449 449 50 mm dia BI01010001010000000000000515BI0100001561 1 M
450 450 65 mm dia BI01010001010000000000000515BI0100001562 1 M
451 451 80 mm dia BI01010001010000000000000515BI0100001563 1 M
452 452 100 mm dia BI01010001010000000000000515BI0100001564 1 M
453 453 150 mm dia BI01010001010000000000000515BI0100001565 1 M
454 454 200 mm dia BI01010001010000000000000515BI0100001566 1 M
455 455 250 mm dia BI01010001010000000000000515BI0100001567 1 M
456 456 300 mm dia BI01010001010000000000000515BI0100001568 1 M
457 457 350 mm dia BI01010001010000000000000515BI0100001569 1 M
458 458 400 mm dia BI01010001010000000000000515BI0100001570 1 M
459 459 450 mm dia BI01010001010000000000000515BI0100001571 1 M
460 460 Supply of following Weld neck type- WNRF as per ASTM A- 105 Class 150; ANSI B 16.5 BI01010001010000000000000515BI0100001572
461 461 25 mm dia BI01010001010000000000000515BI0100001573 1 EA
462 462 50 mm dia BI01010001010000000000000515BI0100001574 1 EA
463 463 80 mm dia BI01010001010000000000000515BI0100001575 1 EA
464 464 100 mm dia BI01010001010000000000000515BI0100001576 1 EA
465 465 150 mm dia BI01010001010000000000000515BI0100001577 1 EA
466 466 200 mm dia BI01010001010000000000000515BI0100001578 1 EA
467 467 250 mm dia BI01010001010000000000000515BI0100001579 1 EA
468 468 300 mm dia BI01010001010000000000000515BI0100001580 1 EA
469 469 350 mm dia BI01010001010000000000000515BI0100001581 1 EA
470 470 400 mm dia BI01010001010000000000000515BI0100001582 1 EA
471 471 450 mm dia BI01010001010000000000000515BI0100001583 1 EA
472 472 Supply of following SORF type- Material for SORF flanges to conform to ASTM A-105 class 150 ; ANSI B 16.5 BI01010001010000000000000515BI0100001584
473 473 25 mm dia BI01010001010000000000000515BI0100001585 1 EA
474 474 50 mm dia BI01010001010000000000000515BI0100001586 1 EA
475 475 80 mm dia BI01010001010000000000000515BI0100001587 1 EA
476 476 100 mm dia BI01010001010000000000000515BI0100001588 1 EA
477 477 150 mm dia BI01010001010000000000000515BI0100001589 1 EA
478 478 200 mm dia BI01010001010000000000000515BI0100001590 1 EA
479 479 250 mm dia BI01010001010000000000000515BI0100001591 1 EA
480 480 300 mm dia BI01010001010000000000000515BI0100001592 1 EA
481 481 350 mm dia BI01010001010000000000000515BI0100001593 1 EA
482 482 400 mm dia BI01010001010000000000000515BI0100001594 1 EA
483 483 450 mm dia BI01010001010000000000000515BI0100001595 1 EA
484 484 Supply of following BLRF flanges As per ASTM A- 105 Class 150; ANSI B 16.5 BI01010001010000000000000515BI0100001596
485 485 25 mm dia BI01010001010000000000000515BI0100001597 1 EA
486 486 50 mm dia BI01010001010000000000000515BI0100001598 1 EA
487 487 80 mm dia BI01010001010000000000000515BI0100001599 1 EA
488 488 100 mm dia BI01010001010000000000000515BI0100001600 1 EA
489 489 150 mm dia BI01010001010000000000000515BI0100001601 1 EA
490 490 200 mm dia BI01010001010000000000000515BI0100001602 1 EA
491 491 250 mm dia BI01010001010000000000000515BI0100001603 1 EA
492 492 300 mm dia BI01010001010000000000000515BI0100001604 1 EA
493 493 350 mm dia BI01010001010000000000000515BI0100001605 1 EA
494 494 400 mm dia BI01010001010000000000000515BI0100001606 1 EA
495 495 450 mm dia BI01010001010000000000000515BI0100001607 1 EA
496 496 Supply of Auto Recirculation valves as per specifications ( ASTM-A216 GR WCB) BI01010001010000000000000515BI0100001608
497 497 80 mm dia BI01010001010000000000000515BI0100001609 1 EA
498 498 100 mm dia BI01010001010000000000000515BI0100001610 1 EA
499 499 150 mm dia BI01010001010000000000000515BI0100001611 1 EA
500 500 200 mm dia BI01010001010000000000000515BI0100001612 1 EA
501 501 Supply of Thermal Relief Valves as per specifications ASTM-A216 GR WCB TRIM SS 410 BI01010001010000000000000515BI0100001613
502 502 Inlet 25 mm X Outlet 25 mm BI01010001010000000000000515BI0100001614 1 EA
503 503 Inlet 25 mm X Outlet 50 mm BI01010001010000000000000515BI0100001615 1 EA
504 504 Supply (Class-800) CS Gate Valve for pressure relief lines as per enclosed specification\nGate Vlv API 602 CL800 SWE Bltd Bonnet Handwheel Operator\nA105 Trim 8 to API 600 602 (13% Cr Hard faced Seat) OS&Y Graphite Gland Packing API 598 Solid Wedge BI01010001010000000000000515BI0100001616
505 505 20 mm dia BI01010001010000000000000515BI0100001617 1 EA
506 506 Supply (Class-150) CS Gate Valve for pneumatic piping system: Gate Vlv MSS SP- 80 CL150 FTE Thd.Bonnet Handwheel Operator B 62 Cl.C83600 Bronze trim PTFE Gland Packing I.S.R.S. API 598 Solid Wedge BI01010001010000000000000515BI0100001618
507 507 50 mm dia BI01010001010000000000000515BI0100001619 1 EA
508 508 25 mm dia BI01010001010000000000000515BI0100001620 1 EA
509 509 Supply of Y type (40 mesh) strainers as per specs and drawing for the hydrant / water piping system including fire water pumps & sprinkler/foam headers for the following LPM & pipeline sizes: BI01010001010000000000000515BI0100001621
510 510 300 mm (Y type) & flowrate 616KL/HR BI01010001010000000000000515BI0100001622 1 EA
511 511 250 mm (Y type) & flowrate 410KL/HR BI01010001010000000000000515BI0100001623 1 EA
512 512 150 mm (Y type) & flowrate 2400 LPM BI01010001010000000000000515BI0100001624 1 EA
513 513 100 mm (Y type) & flowrate 1500 LPM BI01010001010000000000000515BI0100001625 1 EA
514 514 Supplying 3 Ph, 440 V NFLP type mono block motor pumpset with base frame & required accessories including heavy duty GM foot valve for the suction side of the pump etc as per specifications. Makeup Water Pump : Capacity of pump: 90 Cum/ Hr X 36 M head. BI01010001010000000000000515BI0100001626 1 EA
515 515 PIPE FITTINGS BI01010001010000000000000515BI0100001627
516 516 Supplying the following sizes of Bend/ Tees/ Reducer made of carbon steel seamless pipes with beveled ends as per enclosed specifications for the following sizes Note: The fittings shall be as per ASTM A 234 Grade WPB schedule 40 and dimensions as per ASME B 16.9 & all fitting should be forged fitting . BI01010001010000000000000515BI0100001628
517 517 Note: The quantities given are only indicative. The actual quantities to be supplied will be based on the finalized drawing for pipeline routing, as per site requirements and to be approved by the site engineer. BI01010001010000000000000515BI0100001629
518 518 90°LR Bend (1.5D) BI01010001010000000000000515BI0100001630
519 519 25 mm dia BI01010001010000000000000515BI0100001631 1 EA
520 520 50 mm dia BI01010001010000000000000515BI0100001632 1 EA
521 521 80 mm dia BI01010001010000000000000515BI0100001633 1 EA
522 522 100mm dia BI01010001010000000000000515BI0100001634 1 EA
523 523 150 mm dia BI01010001010000000000000515BI0100001635 1 EA
524 524 200 mm dia BI01010001010000000000000515BI0100001636 1 EA
525 525 250 mm dia BI01010001010000000000000515BI0100001637 1 EA
526 526 300 mm dia BI01010001010000000000000515BI0100001638 1 EA
527 527 350 mm dia BI01010001010000000000000515BI0100001639 1 EA
528 528 400 mm dia BI01010001010000000000000515BI0100001640 1 EA
529 529 450 mm dia BI01010001010000000000000515BI0100001641 1 EA
530 530 45°LR Bend (1.5D) BI01010001010000000000000515BI0100001642
531 531 25 mm dia BI01010001010000000000000515BI0100001643 1 EA
532 532 50 mm dia BI01010001010000000000000515BI0100001644 1 EA
533 533 80 mm dia BI01010001010000000000000515BI0100001645 1 EA
534 534 100mm dia BI01010001010000000000000515BI0100001646 1 EA
535 535 150 mm dia BI01010001010000000000000515BI0100001647 1 EA
536 536 200 mm dia BI01010001010000000000000515BI0100001648 1 EA
537 537 250 mm dia BI01010001010000000000000515BI0100001649 1 EA
538 538 300 mm dia BI01010001010000000000000515BI0100001650 1 EA
539 539 350 mm dia BI01010001010000000000000515BI0100001651 1 EA
540 540 400 mm dia BI01010001010000000000000515BI0100001652 1 EA
541 541 450 mm dia BI01010001010000000000000515BI0100001653 1 EA
542 542 Equal Tee BI01010001010000000000000515BI0100001654
543 543 25 x 25 x 25 mm BI01010001010000000000000515BI0100001655 1 EA
544 544 50 x 50 X 50 mm BI01010001010000000000000515BI0100001656 1 EA
545 545 80 X 80 X 80 mm BI01010001010000000000000515BI0100001657 1 EA
546 546 100 X 100 X 100 mm BI01010001010000000000000515BI0100001658 1 EA
547 547 150 X 150 X 150 mm BI01010001010000000000000515BI0100001659 1 EA
548 548 200 X 200 X 200 mm BI01010001010000000000000515BI0100001660 1 EA
549 549 250 X 250 X 250 mm BI01010001010000000000000515BI0100001661 1 EA
550 550 300 X 300 X 300 mm BI01010001010000000000000515BI0100001662 1 EA
551 551 400 X 400 X 400 mm BI01010001010000000000000515BI0100001663 1 EA
552 552 UNEQUAL TEE BI01010001010000000000000515BI0100001664
553 553 200 x 200 x 100 mm BI01010001010000000000000515BI0100001665 1 EA
554 554 200 x 200 x 80 mm BI01010001010000000000000515BI0100001666 1 EA
555 555 150 x 150 x 100 mm BI01010001010000000000000515BI0100001667 1 EA
556 556 150 x 150 x 80 mm BI01010001010000000000000515BI0100001668 1 EA
557 557 100 x 100 x 80 mm BI01010001010000000000000515BI0100001669 1 EA
558 558 200 X 200 X150 mm BI01010001010000000000000515BI0100001670 1 EA
559 559 250 X 250 X 100 mm BI01010001010000000000000515BI0100001671 1 EA
560 560 250 X 250 X 150 mm BI01010001010000000000000515BI0100001672 1 EA
561 561 300 x 300 x 100 mm BI01010001010000000000000515BI0100001673 1 EA
562 562 300 X 300 X 150 mm BI01010001010000000000000515BI0100001674 1 EA
563 563 300 X 300 X 200 mm BI01010001010000000000000515BI0100001675 1 EA
564 564 300 X 300 X 250 mm BI01010001010000000000000515BI0100001676 1 EA
565 565 350 X 350 X 300 mm BI01010001010000000000000515BI0100001677 1 EA
566 566 400 x 400 X 300 mm BI01010001010000000000000515BI0100001678 1 EA
567 567 450 X 450 X 150 mm BI01010001010000000000000515BI0100001679 1 EA
568 568 450 X 450 X 250 mm BI01010001010000000000000515BI0100001680 1 EA
569 569 450 X 450 X 300 mm BI01010001010000000000000515BI0100001681 1 EA
570 570 Reducers (Concentric/ Eccentric) BI01010001010000000000000515BI0100001682
571 571 Reducers (Concentric) BI01010001010000000000000515BI0100001683
572 572 250 X 150 mm BI01010001010000000000000515BI0100001684 1 EA
573 573 150 X 100 mm BI01010001010000000000000515BI0100001685 1 EA
574 574 150 X 80 mm BI01010001010000000000000515BI0100001686 1 EA
575 575 100 X 80 mm BI01010001010000000000000515BI0100001687 1 EA
576 576 Reducers (Eccentric) BI01010001010000000000000515BI0100001688
577 577 350 X 250 mm BI01010001010000000000000515BI0100001689 1 EA
578 578 250 X 200 mm BI01010001010000000000000515BI0100001690 1 EA
579 579 250 X 150 mm BI01010001010000000000000515BI0100001691 1 EA
580 580 150 X 100 mm BI01010001010000000000000515BI0100001692 1 EA
581 581 150 X 100 mm BI01010001010000000000000515BI0100001693 1 EA
582 582 100 X 80 mm BI01010001010000000000000515BI0100001694 1 EA
583 583 300 X 200 mm (ECCEN) BI01010001010000000000000515BI0100001695 1 EA
584 584 250 X 200mm (CONC) BI01010001010000000000000515BI0100001696 1 EA
585 585 300 X 200 mm (CONC) BI01010001010000000000000515BI0100001697 1 EA
586 586 300 x 150mm (CONC) BI01010001010000000000000515BI0100001698 1 EA
587 587 Supplying the following sizes of CS Gate Valves (flanged) as per Specification BI01010001010000000000000515BI0100001699
588 588 20 mm dia BI01010001010000000000000515BI0100001700 1 EA
589 589 25 mm dia BI01010001010000000000000515BI0100001701 1 EA
590 590 50 mm dia BI01010001010000000000000515BI0100001702 1 EA
591 591 80 mm dia BI01010001010000000000000515BI0100001703 1 EA
592 592 100mm dia BI01010001010000000000000515BI0100001704 1 EA
593 593 150 mm dia BI01010001010000000000000515BI0100001705 1 EA
594 594 200 mm dia BI01010001010000000000000515BI0100001706 1 EA
595 595 Supplying the following sizes of Check Valves (flanged) as per Specification BI01010001010000000000000515BI0100001707
596 596 150 mm dia BI01010001010000000000000515BI0100001708 1 EA
597 597 250 mm dia BI01010001010000000000000515BI0100001709 1 EA
598 598 300 mm dia BI01010001010000000000000515BI0100001710 1 EA
599 599 Supplying the following sizes of Check\nValves (flanged) as perSpecification BI01010001010000000000000515BI0100001711
600 600 25 mm dia BI01010001010000000000000515BI0100001712 1 EA
601 601 50 mm dia BI01010001010000000000000515BI0100001713 1 EA
602 602 80 mm dia BI01010001010000000000000515BI0100001714 1 EA
603 603 Making , supply and Fixing of GI Groove\ncoupling BI01010001010000000000000515BI0100001715
604 604 100 mm Dia BI01010001010000000000000515BI0100001716 1 EA
605 605 80 mm Dia BI01010001010000000000000515BI0100001717 1 EA
606 606 65 mm Dia BI01010001010000000000000515BI0100001718 1 EA
607 607 Design, fabrication, supply to site,\nerection, testing and commissioningof\nFoam Concentrate Tank & associated\nsystem comprising of thefollowing; BI01010001010000000000000515BI0100001719
608 608 a) Foam concentrate tank in 3 mm thk, SS 304 with cover and lockingarrangement, vent pipe, fill pipe, level indicator with suitabletransparent PVC tubing and control valves (2 no, 3/4 "" SS SW valve)b) 2 nos, 20/ 25/ 32 mm dia outlets as per design for connections to beestablished to inductors at tanks along with providing and fixing 2 no SSSW valves.c) Drain line with 1 no, 20/25 mm dia valve as per design.d) Piping in SS 304 (3 mm thk) from tank to the inductor to be fitted onthe main fire hydrant line. This pipe shall be taken as 25 mm dia and total length upto 10 RM.e) MS structural staging for mounting the foam concentrate tank withsuitable approach for filling/draining the foam and for operating the tank for FF purpose.f) Shed/ cover for the entire foam concentrate tank and its fittings inMS structurals with asbestos sheet top.g) MS structural support shall be painted as per IOC painting scheme BI01010001010000000000000515BI0100001720
609 609 Note: a) All valves on the tank shall\nbe of SS 304 ball valves and offire\nsafe quality & flanged ends.b) The\ncontractor shall submit the detailed\ndesign & fabricationdrawings along with\nBill of materials (BOM) and get the\nsame approved byIOC, before procurement\nof materials and execution of the above\nwork.c) Foam concentrate solution shall\nbe supplied by IOCL. " BI01010001010000000000000515BI0100001721
610 610 Stainless Steel (SS 304) Tank - 1500 Lts BI01010001010000000000000515BI0100001722 1 EA
611 611 Stainless Steel (SS 304) Tank - 2000 Lts BI01010001010000000000000515BI0100001723 1 EA
612 612 Stainless Steel (SS 304) Tank - 3000 Lts BI01010001010000000000000515BI0100001724 1 EA
613 613 FABRICATION & ERECTION WORKS BI01010001010000000000000515BI0100001725
614 614 Providing and fixing double rows scaffolding system up to required height made with 40 mm dia NB M.S. tube, , M.S. tube challies, M.S. clamps including M.S. staircase system in the scaffolding and working platform as required etc., complete as per drawing & specification and maintaining it in a serviceable condition for the required duration and removing it there after (all materials belongs to Contractor). BI01010001010000000000000515BI0100001726
615 615 The scaffolding system shall be stiffened with bracings, runners, connection with the tank etc., wherever required for inspection of work at required locations with essential safety features for the workmen as per directions and approval of Engineering-charge. BI01010001010000000000000515BI0100001727
616 616 Note: a) Scaffolding should be retained till the completion of hydro-stat test/ calibration/ painting as per requirement. BI01010001010000000000000515BI0100001728
617 617 b) For External Scaffolding -Payments shall be made for actual area of scaffolding provided based on requirement. Area of scaffolding will be measured on the basis of actual height of scaffolding provided multiplied by actual average length/circumference of scaffolding provided. BI01010001010000000000000515BI0100001729
618 618 c) For tank Internal scaffolding- payment will be made on the basis of covered shell area & roof area of the tank. BI01010001010000000000000515BI0100001730
619 619 For vertical tanks BI01010001010000000000000515BI0100001731 1 M2
620 620 Providing and fixing Hydraulic Jacking System including positioing the same on the bottom plate without any damage, necessary supports with MS structural/ Pipes, gazzet plates etc., complete as per standards/ instructions and maintaining it in a serviceable condition for the required duration and removing it there after (all materials belongs to Contractor). BI01010001010000000000000515BI0100001732
621 621 Note: a) Hydraulic Jacking System should be retained till the replacement of shell/ bottom plates works are completed as per requirement. BI01010001010000000000000515BI0100001733
622 622 b) The payment for the Jacking System (external/ internal) will be made on the basis of perimeter of shell of the tank. BI01010001010000000000000515BI0100001734
623 623 For vertical tanks - inside BI01010001010000000000000515BI0100001735 1 M
624 624 For vertical tanks - outside the tanks with MS structural supports. BI01010001010000000000000515BI0100001736 1 M
625 625 Fabricating, erecting, welding, testing and commissioning SHELL/ BOTTOM/ ROOF plates for vertical tanks as per the approved design, specifications and B&R drawings with required steel plates supplied by IOC. All other items such as labour, equipment, power, consumables etc., shall be supplied by contractor. All leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001737
626 626 Note : a) IOCL shall supply steel plates only for bottom, shell, double deck roof, wind girders and reinforcement plates of shell appurtenances. BI01010001010000000000000515BI0100001738
627 627 b) Item rate should include shifting of steel plates within the premises and conducting various tests on tanks during fabrication as per attached TESTING PROCEDURE. Item includes Radiographic Inspection of welds as per attached RADIOGRAPHIC INSPECTION PROCEDURE. BI01010001010000000000000515BI0100001739
628 628 Shell/ bottom/ Roof/ deck plates - without jacking system BI01010001010000000000000515BI0100001740 1 TON
629 629 Shell plates - with jacking system BI01010001010000000000000515BI0100001741 1 TON
630 630 Supplying and providing steps for spiral staircase including supplying & fabricating MS gratings, pad plate, supports, handrail, testing as per as per B&R drgs. No. BR/CR/233 & BR/CR/234, painting the same (external paiting system of tank), all leads & lifts etc., complete in all respects as per instructions at site. BI01010001010000000000000515BI0100001742
631 631 MS grating steps for spiral staircase BI01010001010000000000000515BI0100001743 1 EA
632 632 Supplying and filling with water for conducting hydro test/ floatation test and checking the leaks including supply of water, conveying pipes, water pump, all the material and labour as required etc., complete as directed at site. BI01010001010000000000000515BI0100001744
633 633 Note: a) Water shall be removed after completion of hydrostatic testing of tanks & emptied from the tank including cleaning of the bottom plate & sump and boxing up of the tank before water filling and removal of manholes covers after testing with necessary supply of bolts, studs/ nuts/ gaskets etc., to ensure leak proof. BI01010001010000000000000515BI0100001745
634 634 b) Water is to be filled till full height of tank. Payment will be made for total quantity of water mathematically or arithmetically calculated, as per size of tank. BI01010001010000000000000515BI0100001746
635 635 For vertical tanks - all capacities BI01010001010000000000000515BI0100001747 1 KL
636 636 Carrying out hydro test of tanks EXCLUDING supply of water. \nWater conveying pipes, water pumps, all material and labour, as required shall be arranged by the contractor Including providing rubber gasket for hydro testing. WATER shall be provided by IOCL within terminal premises. However the vendor shall make all necessary arrangements to pump the water into tank & to drain out the water also at no extra cost to IOCL. BI01010001010000000000000515BI0100001748
637 637 For vertical tanks - all capacities BI01010001010000000000000515BI0100001749 1 KL
638 638 Calibration of tanks- Bottom calibration with actual physical measurement by water meter & tank shell by strapping periphery of different strakes above and below the horizontal weld joints (or) by using optical ranging method. Item includes cost towards statutory payment to be made to the authorities and all other incidental costs. Item includes preparation & submission of calibration charts in quadruplicate duly approved by the tank calibration authority. Water required for the calibration shall be arranged by the successful tenderer at his own cost. BI01010001010000000000000515BI0100001750
639 639 Upto 10 M dia vertical tank BI01010001010000000000000515BI0100001751 1 SET
640 640 10 M to 16 M dia vertical tank BI01010001010000000000000515BI0100001752 1 SET
641 641 18 M to 24 M dia vertical tank BI01010001010000000000000515BI0100001753 1 SET
642 642 20 M to 32 M dia vertical tank BI01010001010000000000000515BI0100001754 1 SET
643 643 32 M to 40 M dia vertical tank BI01010001010000000000000515BI0100001755 1 SET
644 644 Boxing up of the tank after completion of all works and inspection including supplying, fixing 3 mm CAF 9 gaskets of approved make as per IS 2712 - 1979 with new sets of bolts, studs & nuts confirming to IS 1363 & 1367 and washers of approved quality. Job includes for all manholes, nozzles, inlet/outlet valves. water draw off valves etc., complete to ensure leak proof as per instruction at site. BI01010001010000000000000515BI0100001756
645 645 For vertical tanks BI01010001010000000000000515BI0100001757 1 SET
646 646 Supplying and providing temporary screen wall as per site requirements using MS section frame work and GI sheets for carrying out the hot work within the licensed premises. The screen wall will be dismantled and taken out after completion of works & shall remain contractor's property. BI01010001010000000000000515BI0100001758
647 647 Note: a) The contractor shall submit the details of design & drawings of the screen wall to be erected at site & approved prior commencement of work. BI01010001010000000000000515BI0100001759
648 648 b) The screen wall shall be in position at all time, stable & strong till the completion of work in all respects. BI01010001010000000000000515BI0100001760
649 649 i) Fixed BI01010001010000000000000515BI0100001761 1 M2
650 650 ii) Mobile with wheels (or) movable BI01010001010000000000000515BI0100001762 1 M2
651 651 Supplying and providing temporary screen wall as per site requirements using the available scaffolding structure and GI sheets with required fastners for carrying out the hot work within the licensed premises. The screen wall will be dismantled and taken out after completion of works & shall remain contractor's property. BI01010001010000000000000515BI0100001763 1 M2
652 652 DRAWINGS:\nSubmission of detailed design/ fabrication drawings for the different size of tanks for approval of IOCL. Item includes submission of as built drawings (4 sets) including submission of drawings on a CD after completion of tank fabrication work as per enclosed specifications. Note: The drawings should be made in reference to the attached directional drawings and as per requirement of IS 803 & API 650. BI01010001010000000000000515BI0100001764 1 EA
653 653 RE-PAINTING WORKS BI01010001010000000000000515BI0100001765
654 654 Removal of existing internal paint including primer completely by grit blasting to SA 2 1/2. Scaffolding if required will be paid separately. BI01010001010000000000000515BI0100001766 1 M2
655 655 UNDERSIDE OF TANK BOTTOM PLATE : ZONE-A & ZONE-B : FIRST TIME PAINTING\nApplicable for NEW CR/IFR/FR PRODUCT & WATER tank\n1. Surface Preparation as per SA 2½\n2. Primer : P1-Inorganic Zinc Ethyl Silicate : Single Coat: DFT- 65-75µ\n3. Finish Coat : F3-Amine Adduct cured HB Epoxy Liner : Two coats : DFT- 100-125µ per coat\nTotal Min DFT 265µ BI01010001010000000000000515BI0100001767 1 M2
656 656 RE-PAINTING OF TANKS: (including all material/ labour) Surface preparation and painting of the following tanks as per details of painting specification given under and the Techno-Commercial bid; Note: Application for External/ Internal painting for tanks shall be carried out by means of AIRLESS SPRAY PAINTING SYSTEM only. BI01010001010000000000000515BI0100001768
657 657 Surface preparation by cleaning & painting the outside surface of tank shell upto & including curb angle, upper side surface of roof, wind girders, roof, stairs and shell appurtenances of CONE/ FLOATING ROOF tanks including all fittings and appurtenances etc., providing IOC logo with tank writing work as per enclosed specifications and drawings. BI01010001010000000000000515BI0100001769
658 658 Note : Area to be painted & type of paint shall be as per IOC Painting scheme given in the tender. Finish paint colour shall be as per requirement of white oil or black oil tanks. BI01010001010000000000000515BI0100001770
659 659 NEW CONSTRUCTION- PAINTING EXTERNAL SURFACES: (including all material/ labour); BI01010001010000000000000515BI0100001771
660 660 PRODUCT TANKS - HSD/ SKO/ ATF/ MS/ NAPHTHA/ FO/ LDO/ WATER BI01010001010000000000000515BI0100001772
661 661 For ZONE A (Corrosive Zone) - External Surface of un-insulated equipment including storage tanks (product & water services - shell & roof top), piping & structures (upto 120 deg C) BI01010001010000000000000515BI0100001773 1 M2
662 662 Surface Preparation : Blast clean to SA 2 1/2 BI01010001010000000000000515BI0100001774
663 663 Primer : Inorganic Zinc Ethyl Silicate (P1) with DFT in the range of 65-75 micron. BI01010001010000000000000515BI0100001775
664 664 Intermediate Coat : Polyamide cured HB Epoxy MIO (U1) with DFT in the range of 100 -125 micron. BI01010001010000000000000515BI0100001776
665 665 Finish Coat : Two Pack Acrylic Poly-urethane(PU) (F1) with DFT in the range of 40-50 micron. BI01010001010000000000000515BI0100001777
666 666 TOTAL min DFT 215 microns BI01010001010000000000000515BI0100001778
667 667 For ZONE B (Non-Corrosive Zone) - External Surface of un-insulated equipment including storage tanks (product & water services - shell & roof top), piping & structures (upto 120 deg C) BI01010001010000000000000515BI0100001779 1 M2
668 668 Surface Preparation : Blast clean to SA 2 1/2 BI01010001010000000000000515BI0100001780
669 669 Primer : Red Oxide Zinc Phosphate Primer (P3) with 2 coats of DFT in the range of 30-35 micron. BI01010001010000000000000515BI0100001781
670 670 Finish Coat : Aluminium Finish Paint (F2) with 2 coats of DFT in the range of 15-20 micron. BI01010001010000000000000515BI0100001782
671 671 TOTAL min DFT 90 microns BI01010001010000000000000515BI0100001783
672 672 RE-PAINTING EXTERNAL SURFACES: (including all material/ labour); BI01010001010000000000000515BI0100001784
673 673 PRODUCT TANKS - HSD/ SKO/ ATF/ MS/ NAPHTHA/ FO/ LDO/ WATER BI01010001010000000000000515BI0100001785
674 674 For ZONE A & B- External Surface of buried tanks/ piping. Underside of tank and external surface of buried vessels/ tanks / piping. BI01010001010000000000000515BI0100001786 1 M2
675 675 Surface Preparation : Blast clean to SA 2 1/2 BI01010001010000000000000515BI0100001787
676 676 Primer : Inorganic Zinc Ethyl Silicate (P1) with DFT in the range of 65-75 micron. BI01010001010000000000000515BI0100001788
677 677 Finish Coat : Amine Adduct Cured HB epoxy liner (F3) with 2 coats of DFT in the range of 100-125 micron. BI01010001010000000000000515BI0100001789
678 678 TOTAL min DFT 265 microns BI01010001010000000000000515BI0100001790
679 679 For ZONE A (Corrosive Zone) - External Surface of un-insulated equipment including storage tanks (product & water services - shell & roof top), piping & structures (upto 120 deg C) BI01010001010000000000000515BI0100001791 1 M2
680 680 Surface Preparation : i) SSPC SP2 - Hand Cleaning / Wire brush or ii) SSPC SP-3 - Power Tool Cleaning BI01010001010000000000000515BI0100001792
681 681 Primer : Self Priming HB Epoxy mastic Coating (P4) with DFT in the range of 100 -125 micron. BI01010001010000000000000515BI0100001793
682 682 Intermediate Coat : Polyamide cured HB Epoxy MIO (U1) with DFT in the range of 100 -125 micron. BI01010001010000000000000515BI0100001794
683 683 Finish Coat : Two Pack Acrylic Poly-urethane(PU) (F1) with DFT in the range of 40-50 micron. BI01010001010000000000000515BI0100001795
684 684 TOTAL min DFT 240 microns BI01010001010000000000000515BI0100001796
685 685 For ZONE B (Non Corrosive Zone) - External Surface of un-insulated equipment including storage tanks (product & water services - shell & roof top), piping & structures (upto 120 deg C) BI01010001010000000000000515BI0100001797 1 M2
686 686 Surface Preparation : i) SSPC SP2 - Hand Cleaning / Wire brush or ii) SSPC SP-3 - Power Tool Cleaning BI01010001010000000000000515BI0100001798
687 687 Primer : Red Oxide Zinc Phosphate Primer (P3) with DFT in the range of 30-35 micron. BI01010001010000000000000515BI0100001799
688 688 Finish Coat : Aluminium Finish Paint (F2) with 2 coats of DFT in the range of 15-20 micron. BI01010001010000000000000515BI0100001800
689 689 TOTAL min DFT 60 microns BI01010001010000000000000515BI0100001801
690 690 INTERNAL SURFACES: (including all material/ labour); BI01010001010000000000000515BI0100001802
691 691 PRODUCT TANKS - HSD/ SKO/ ATF/ MS/ NAPHTHA/ FO/ LDO & WATER BI01010001010000000000000515BI0100001803
692 692 For ZONE A & B-Internal Surface of tanks in Hydrocarbon service except ATF (In case of full painting/repainting) BI01010001010000000000000515BI0100001804 1 M2
693 693 Surface Preparation :Blast clean to SA 2 1/2 BI01010001010000000000000515BI0100001805
694 694 Primer : Inorganic Zinc Ethyl Silicate (P1) with DFT in the range of 65-75 micron. BI01010001010000000000000515BI0100001806
695 695 Intermediate Coat : Epoxy Zinc Phophate (P5) with DFT in the range of 35-40 micron. BI01010001010000000000000515BI0100001807
696 696 Finish Coat : Amine Adduct Cured HB epoxy liner (F3) with 2 coats of DFT in the range of 100-125 micron. BI01010001010000000000000515BI0100001808
697 697 TOTAL min DFT 300 microns BI01010001010000000000000515BI0100001809
698 698 For ZONE A & B-Internal Surface of tanks in ATF service (In case of full painting/repainting) BI01010001010000000000000515BI0100001810 1 M2
699 699 Surface Preparation :Blast clean to SA 2 1/2 BI01010001010000000000000515BI0100001811
700 700 Primer : Polyamide cured epoxy zinc phosphate primer (P2) with DFT in the range of 70-75 micron. BI01010001010000000000000515BI0100001812
701 701 Intermediate Coat : Epoxy Zinc Phophate (P5) with DFT in the range of 35-40 micron. BI01010001010000000000000515BI0100001813
702 702 Finish Coat : Amine Adduct Cured HB epoxy liner (F3) with 2 coats of DFT in the range of 100-125 micron. BI01010001010000000000000515BI0100001814
703 703 TOTAL min DFT 305 microns BI01010001010000000000000515BI0100001815
704 704 For ZONE A & B-Internal Surface of tanks in water (Fire water, Industrial water) in case of full painting/repainting. BI01010001010000000000000515BI0100001816 1 M2
705 705 Surface Preparation : Blast clean to SA 2 1/2 BI01010001010000000000000515BI0100001817
706 706 Primer : Polyamide cured epoxy zinc phosphate primer (P2) with DFT in the range of 70-75 micron. BI01010001010000000000000515BI0100001818
707 707 Finish Coat : Solvent less HB epoxy liner (F4) with 2 coats of DFT 250 micron each. BI01010001010000000000000515BI0100001819
708 708 TOTAL min DFT 575 microns BI01010001010000000000000515BI0100001820
709 709 For ZONE A & B-Internal Surface of Pontoon of floating roof tanks BI01010001010000000000000515BI0100001821 1 M2
710 710 Surface Preparation : i) SSPC SP2 - Hand Cleaning / Wire brush or ii) SSPC SP-3 - Power Tool Cleaning BI01010001010000000000000515BI0100001822
711 711 Primer : Polyamide cured epoxy zinc phosphate primer (P2) with DFT in the range of 70-75 micron. BI01010001010000000000000515BI0100001823
712 712 TOTAL min DFT 70 microns BI01010001010000000000000515BI0100001824
713 713 For ZONE A & B-Internal Surface of tanks in Hydrocarbon service including tanks on ATF service ( in case of patch / touch-up painting) BI01010001010000000000000515BI0100001825 1 M2
714 714 Surface Preparation : SSPC SP-3 - Power Tool Cleaning BI01010001010000000000000515BI0100001826
715 715 Primer : Polyamide cured epoxy zinc phosphate primer (P2) with DFT in the range of 70-75 micron. BI01010001010000000000000515BI0100001827
716 716 Finish Coat : Amine Adduct Cured HB epoxy liner (F3) with 2 coats of DFT in the range of 100-125 micron. BI01010001010000000000000515BI0100001828
717 717 TOTAL min DFT 270 microns BI01010001010000000000000515BI0100001829
718 718 For ZONE A & B-Internal Surface of tanks in water (Fire water, Industrial water) service requiring patch/ touch up painting. BI01010001010000000000000515BI0100001830 1 M2
719 719 Surface Preparation : SSPC SP-3 - Power Tool Cleaning BI01010001010000000000000515BI0100001831
720 720 Primer : Polyamide cured epoxy zinc phosphate primer (P2) with DFT in the range of 70-75 micron. BI01010001010000000000000515BI0100001832
721 721 Finish Coat : Solvent less HB epoxy liner (F4) with 2 coats of DFT 250 micron each. BI01010001010000000000000515BI0100001833
722 722 TOTAL min DFT 575 microns BI01010001010000000000000515BI0100001834
723 723 For ZONE A & B-Internal Surface of tanks in water (Fire water, Industrial water) service requiring patch/ touch up painting (In case the water tank is presently painted with Coal Tar Epoxy paint) BI01010001010000000000000515BI0100001835 1 M2
724 724 Surface Preparation : SSPC SP-3 - Power Tool Cleaning BI01010001010000000000000515BI0100001836
725 725 Finish Coat :Two coats of Coal Tar Epoxy (150 microns) BI01010001010000000000000515BI0100001837
726 726 TOTAL min DFT 300 microns BI01010001010000000000000515BI0100001838
727 727 For ZONE A & B-Internal Surface of tanks in Hydrocarbon service except ATF (In case of only blasting and application of Primer) BI01010001010000000000000515BI0100001839 1 M2
728 728 Surface Preparation :Blast clean to SA 2 1/2 BI01010001010000000000000515BI0100001840
729 729 Primer : Inorganic Zinc Ethyl Silicate (P1) with DFT in the range of 65-75 micron. BI01010001010000000000000515BI0100001841
730 730 TOTAL min DFT 65 microns BI01010001010000000000000515BI0100001842
731 731 For ZONE A & B-Internal Surface of tanks in ATF/WATER service (In case of only blasting and application of Primer) BI01010001010000000000000515BI0100001843 1 M2
732 732 Surface Preparation :Blast clean to SA 2 1/2 BI01010001010000000000000515BI0100001844
733 733 Primer : Polyamide cured epoxy zinc phosphate primer (P2) with DFT in the range of 70-75 micron. BI01010001010000000000000515BI0100001845
734 734 TOTAL min DFT 70 microns BI01010001010000000000000515BI0100001846
735 735 RE-PAINTING OF PIPELINES: BI01010001010000000000000515BI0100001847
736 736 Pipeline (AG) of all Product/ Water & its fittings including colour coding as required for Zone A locations. BI01010001010000000000000515BI0100001848
737 737 Surface Preparation : i) SSPC SP2 - Hand Cleaning / Wire brush or ii) SSPC SP-3 - Power Tool Cleaning BI01010001010000000000000515BI0100001849
738 738 Primer : Self Priming HB Epoxy mastic Coating (P4) with DFT in the range of 100 -125 micron. BI01010001010000000000000515BI0100001850
739 739 Intermediate Coat : Polyamide cured HB Epoxy MIO (U1) with DFT in the range of 100 -125 micron. BI01010001010000000000000515BI0100001851
740 740 Finish Coat : Two Pack Acrylic Poly-urethane(PU) (F1) with DFT in the range of 40-50 micron. BI01010001010000000000000515BI0100001852
741 741 TOTAL min DFT 240 microns BI01010001010000000000000515BI0100001853
742 742 50 / 65 mm dia BI01010001010000000000000515BI0100001854 1 M
743 743 80 mm dia BI01010001010000000000000515BI0100001855 1 M
744 744 100 mm dia BI01010001010000000000000515BI0100001856 1 M
745 745 150 mm dia BI01010001010000000000000515BI0100001857 1 M
746 746 200 mm dia BI01010001010000000000000515BI0100001858 1 M
747 747 250 mm dia BI01010001010000000000000515BI0100001859 1 M
748 748 300 mm dia BI01010001010000000000000515BI0100001860 1 M
749 749 350 mm dia BI01010001010000000000000515BI0100001861 1 M
750 750 400 mm dia BI01010001010000000000000515BI0100001862 1 M
751 751 450 mm dia BI01010001010000000000000515BI0100001863 1 M
752 752 500 mm dia BI01010001010000000000000515BI0100001864 1 M
753 753 550 mm dia BI01010001010000000000000515BI0100001865 1 M
754 754 600 mm dia BI01010001010000000000000515BI0100001866 1 M
755 755 650 mm dia BI01010001010000000000000515BI0100001867 1 M
756 756 700 mm dia BI01010001010000000000000515BI0100001868 1 M
757 757 Pipeline (AG) of all Product/ Water & its fittings including colour coding as required for Zone B locations. BI01010001010000000000000515BI0100001869
758 758 Surface Preparation : i) SSPC SP2 - Hand Cleaning / Wire brush or ii) SSPC SP-3 - Power Tool Cleaning BI01010001010000000000000515BI0100001870
759 759 Primer : Red Oxide Zinc Phosphate Primer (P3) with DFT in the range of 30-35 micron. BI01010001010000000000000515BI0100001871
760 760 Finish Coat : For all product piplines Aluminium Finish Paint (F2) with 2 coats of DFT in the range of 15-20 micron. For Fire lines Synthetic Enamel (F6) 2 coats of DFT in the range of 15-20 micron. BI01010001010000000000000515BI0100001872
761 761 TOTAL min DFT 60 microns BI01010001010000000000000515BI0100001873
762 762 50 / 65 mm dia BI01010001010000000000000515BI0100001874 1 M
763 763 80 mm dia BI01010001010000000000000515BI0100001875 1 M
764 764 100 mm dia BI01010001010000000000000515BI0100001876 1 M
765 765 150 mm dia BI01010001010000000000000515BI0100001877 1 M
766 766 200 mm dia BI01010001010000000000000515BI0100001878 1 M
767 767 250 mm dia BI01010001010000000000000515BI0100001879 1 M
768 768 300 mm dia BI01010001010000000000000515BI0100001880 1 M
769 769 350 mm dia BI01010001010000000000000515BI0100001881 1 M
770 770 400 mm dia BI01010001010000000000000515BI0100001882 1 M
771 771 450 mm dia BI01010001010000000000000515BI0100001883 1 M
772 772 500 mm dia BI01010001010000000000000515BI0100001884 1 M
773 773 550 mm dia BI01010001010000000000000515BI0100001885 1 M
774 774 600 mm dia BI01010001010000000000000515BI0100001886 1 M
775 775 650 mm dia BI01010001010000000000000515BI0100001887 1 M
776 776 700 mm dia BI01010001010000000000000515BI0100001888 1 M
777 777 Pipeline (UG) of all Product/ Water & its fittings BI01010001010000000000000515BI0100001889
778 778 Clean to SSPC SP 2 hand cleaning wire brushing. BI01010001010000000000000515BI0100001890
779 779 Coating/ Wrapping tape as per specification in the tender. BI01010001010000000000000515BI0100001891
780 780 80 mm dia BI01010001010000000000000515BI0100001892 1 M
781 781 100 mm dia BI01010001010000000000000515BI0100001893 1 M
782 782 150 mm dia BI01010001010000000000000515BI0100001894 1 M
783 783 200 mm dia BI01010001010000000000000515BI0100001895 1 M
784 784 250 mm dia BI01010001010000000000000515BI0100001896 1 M
785 785 300 mm dia BI01010001010000000000000515BI0100001897 1 M
786 786 350 mm dia BI01010001010000000000000515BI0100001898 1 M
787 787 400 mm dia BI01010001010000000000000515BI0100001899 1 M
788 788 450 mm dia BI01010001010000000000000515BI0100001900 1 M
789 789 500 mm dia BI01010001010000000000000515BI0100001901 1 M
790 790 Repainting of GI pipelines & its\nfittingsClean to SSPC SP 2 hand\ncleaning wire brushing.One coat of Etch\nPrimer (6 micron)One coat of Mastic Coating\n- P4 (175 micron)Two coat of Acrylic\nPolyurethane - F1 (40-45 micron each)Total\nDFT of 261 micron BI01010001010000000000000515BI0100001902
791 791 25 mm dia BI01010001010000000000000515BI0100001903 1 M
792 792 50 / 65 mm dia BI01010001010000000000000515BI0100001904 1 M
793 793 80 mm dia BI01010001010000000000000515BI0100001905 1 M
794 794 100 mm dia BI01010001010000000000000515BI0100001906 1 M
795 795 150 mm dia BI01010001010000000000000515BI0100001907 1 M
796 796 200 mm dia BI01010001010000000000000515BI0100001908 1 M
797 797 250 mm dia BI01010001010000000000000515BI0100001909 1 M
798 798 300 mm dia BI01010001010000000000000515BI0100001910 1 M
799 799 All types of Valves BI01010001010000000000000515BI0100001911
800 800 Clean to SSPC SP 2 hand cleaning wire brushing. BI01010001010000000000000515BI0100001912
801 801 One coat of Zinc Phosphate - P3 (30-35 µ each) + BI01010001010000000000000515BI0100001913
802 802 Two coat of Synthetic Enamel Paint - F4 (25 m each) BI01010001010000000000000515BI0100001914
803 803 Total DFT of 80 m BI01010001010000000000000515BI0100001915
804 804 50 / 65 mm dia BI01010001010000000000000515BI0100001916 1 EA
805 805 80 mm dia BI01010001010000000000000515BI0100001917 1 EA
806 806 100 mm dia BI01010001010000000000000515BI0100001918 1 EA
807 807 150 mm dia BI01010001010000000000000515BI0100001919 1 EA
808 808 200 mm dia BI01010001010000000000000515BI0100001920 1 EA
809 809 250 mm dia BI01010001010000000000000515BI0100001921 1 EA
810 810 300 mm dia BI01010001010000000000000515BI0100001922 1 EA
811 811 350 mm dia BI01010001010000000000000515BI0100001923 1 EA
812 812 400 mm dia BI01010001010000000000000515BI0100001924 1 EA
813 813 450 mm dia BI01010001010000000000000515BI0100001925 1 EA
814 814 500 mm dia BI01010001010000000000000515BI0100001926 1 EA
815 815 550 mm dia BI01010001010000000000000515BI0100001927 1 EA
816 816 600 mm dia BI01010001010000000000000515BI0100001928 1 EA
817 817 650 mm dia BI01010001010000000000000515BI0100001929 1 EA
818 818 700 mm dia BI01010001010000000000000515BI0100001930 1 EA
819 819 Painting of Indian Oil logo on the\nTanks as per the required dimension\nouter surface of Tanks with 2 coats of\nSynthetic Enamel Paint (min25µ for each\ncoat). Item includes supply of Paint,\nAccessories, Labouretc including making\nthe surface clean as per the\ninstruction ofEngineer-in-charge.\nScaffolding shall be paid extra. BI01010001010000000000000515BI0100001931 1 EA
820 820 SPRINKLER & FOAM POURER SYSTEM BI01010001010000000000000515BI0100001932
821 821 Supply, fabricating, welding (3 runs min.), laying and erection above ground/ under ground pipelines including supplying of IS 1239 Heavy grade MS ERW pipes of the following sizes as described below, cutting, beveling and welding the supplied fittings such as elbows, bends, tees, reducers, painting as below etc., complete and hydro testing the pipelines at 10.5 KSC for a minimum period of 4 Hrs. BI01010001010000000000000515BI0100001933
822 822 Note: a) Erection of sprinkler riser/ring shall be done only after hot dip galvanizing of the pre-fabricated section. Payment for hot dip galvanizing will be paid under separate item. BI01010001010000000000000515BI0100001934
823 823 b) Painting shall be as per IOC painting scheme. BI01010001010000000000000515BI0100001935
824 824 A/G pipeline BI01010001010000000000000515BI0100001936
825 825 50 mm dia BI01010001010000000000000515BI0100001937 1 M
826 826 65 mm dia BI01010001010000000000000515BI0100001938 1 M
827 827 80 mm dia BI01010001010000000000000515BI0100001939 1 M
828 828 100 mm dia BI01010001010000000000000515BI0100001940 1 M
829 829 150 mm dia BI01010001010000000000000515BI0100001941 1 M
830 830 200 mm dia BI01010001010000000000000515BI0100001942 1 M
831 831 U/G pipeline with doping as per specification BI01010001010000000000000515BI0100001943
832 832 80 mm dia BI01010001010000000000000515BI0100001944 1 M
833 833 100 mm dia BI01010001010000000000000515BI0100001945 1 M
834 834 150 mm dia BI01010001010000000000000515BI0100001946 1 M
835 835 200 mm dia BI01010001010000000000000515BI0100001947 1 M
836 836 Supply, installation & painting of following # 150 ANSI B 16.5 flanged CS Gate Valves/ Butterfly valves/ CS Ball Valves/ SS ball vales of approved make & of the following sizes on including supplying & fixing 3 mm thk non metallic gaskets, studs/nuts, painting as per specification etc of approved make as per specifications enclosed & site instructions. BI01010001010000000000000515BI0100001948
837 837 Note: Painting shall be as per IOC painting scheme. BI01010001010000000000000515BI0100001949
838 838 CS Flanged type Butterfly valves BI01010001010000000000000515BI0100001950
839 839 150 mm dia BI01010001010000000000000515BI0100001951 1 EA
840 840 CS Flanged type Ball valves BI01010001010000000000000515BI0100001952
841 841 25 mm dia BI01010001010000000000000515BI0100001953 1 EA
842 842 50 mm dia BI01010001010000000000000515BI0100001954 1 EA
843 843 80 mm dia BI01010001010000000000000515BI0100001955 1 EA
844 844 100 mm dia BI01010001010000000000000515BI0100001956 1 EA
845 845 150 mm dia BI01010001010000000000000515BI0100001957 1 EA
846 846 200 mm dia BI01010001010000000000000515BI0100001958 1 EA
847 847 CS Flanged type Knife Edge Valve BI01010001010000000000000515BI0100001959
848 848 100 mm dia BI01010001010000000000000515BI0100001960 1 EA
849 849 150 mm dia BI01010001010000000000000515BI0100001961 1 EA
850 850 200 mm dia BI01010001010000000000000515BI0100001962 1 EA
851 851 Supply of #100 wafer type butterfly valve of approved make to suit SORF/WNRF flanges on pipelines.\nANSI 150 class API 609 AWWA-C504 BS 5155 BI01010001010000000000000515BI0100001963
852 852 80mm dia BI01010001010000000000000515BI0100001964 1 EA
853 853 100mm dia BI01010001010000000000000515BI0100001965 1 EA
854 854 150mm dia BI01010001010000000000000515BI0100001966 1 EA
855 855 200mm dia BI01010001010000000000000515BI0100001967 1 EA
856 856 250mm dia BI01010001010000000000000515BI0100001968 1 EA
857 857 Supply & installation of basket type strainer with body IS 3589 ERW with end flanges having # 150 rating & as per ANSI B 16.5 including supplying & fixing 3 mm thk non metallic gaskets, studs/nuts etc of approved make . Strainer shall have filter with SS 304 wire mesh (100 mesh)/perforated sheet & with 1/2" screwed ball valve at the bottom for drain provision. Strainer shall be tested hydro-statically to 15 kg/sqcm. Allowable pressure drop: 0.5 kg/sqcm under clean condition & 0.8 kg/sqcm under clogged condition. Capacity & size to be as per latest OISD 117, design to be submitted for approval from IOCL. BI01010001010000000000000515BI0100001969
858 858 Note: Painting shall be as per IOC painting scheme. BI01010001010000000000000515BI0100001970
859 859 65 mm dia BI01010001010000000000000515BI0100001971 1 EA
860 860 80 mm dia BI01010001010000000000000515BI0100001972 1 EA
861 861 100 mm dia BI01010001010000000000000515BI0100001973 1 EA
862 862 150 mm dia BI01010001010000000000000515BI0100001974 1 EA
863 863 200 mm dia BI01010001010000000000000515BI0100001975 1 EA
864 864 250 mm dia BI01010001010000000000000515BI0100001976 1 EA
865 865 Supply & installation of following UL/FM listed accessories for fixed water spray & foam pourer system on tanks & FH line of approved make & of the following sizes on including supplying & fixing 3 mm thk non metallic gaskets, studs/nuts, painting as per specification etc of approved make as per specifications enclosed & site instructions. BI01010001010000000000000515BI0100001977
866 866 Note: a) Size, capacity, K factor etc of the accessories shall be as per design confirming to latest OISD 117, design to be submitted for approval by IOCL. BI01010001010000000000000515BI0100001978
867 867 b) Painting shall be as per IOC painting scheme. BI01010001010000000000000515BI0100001979
868 868 In-line foam inductor BI01010001010000000000000515BI0100001980
869 869 65 mm dia BI01010001010000000000000515BI0100001981 1 EA
870 870 80 mm dia BI01010001010000000000000515BI0100001982 1 EA
871 871 100 mm dia BI01010001010000000000000515BI0100001983 1 EA
872 872 150 mm dia BI01010001010000000000000515BI0100001984 1 EA
873 873 Foam Maker - FRVT BI01010001010000000000000515BI0100001985
874 874 50mm dia BI01010001010000000000000515BI0100001986 1 EA
875 875 65mm dia BI01010001010000000000000515BI0100001987 1 EA
876 876 80mm dia BI01010001010000000000000515BI0100001988 1 EA
877 877 Foam Pourer - FRVT BI01010001010000000000000515BI0100001989
878 878 80mm dia BI01010001010000000000000515BI0100001990 1 EA
879 879 100mm dia BI01010001010000000000000515BI0100001991 1 EA
880 880 Foam Chamber - CRVT BI01010001010000000000000515BI0100001992
881 881 50mm dia BI01010001010000000000000515BI0100001993 1 EA
882 882 65mm dia BI01010001010000000000000515BI0100001994 1 EA
883 883 80mm dia BI01010001010000000000000515BI0100001995 1 EA
884 884 100mm dia BI01010001010000000000000515BI0100001996 1 EA
885 885 150mm dia BI01010001010000000000000515BI0100001997 1 EA
886 886 Foam Deflector - CRVT BI01010001010000000000000515BI0100001998
887 887 80mm dia BI01010001010000000000000515BI0100001999 1 EA
888 888 100mm dia BI01010001010000000000000515BI0100002000 1 EA
889 889 150mm dia BI01010001010000000000000515BI0100002001 1 EA
890 890 200mm dia BI01010001010000000000000515BI0100002002 1 EA
891 891 250mm dia BI01010001010000000000000515BI0100002003 1 EA
892 892 MV SS Spray nozzles BI01010001010000000000000515BI0100002004
893 893 K-Factors - K18 BI01010001010000000000000515BI0100002005 1 EA
894 894 K-Factors - K22 to K-53 BI01010001010000000000000515BI0100002006 1 EA
895 895 K-Factors - K54 to K-102 BI01010001010000000000000515BI0100002007 1 EA
896 896 Installation of IOC supplied Spray Nozzles: Handling, erection, testing & commissioning of Medium Velocity Water Spray Nozzle of 1/2" BSPT male thread including all necessary consumables complete in all respect as per instructions. BI01010001010000000000000515BI0100002008
897 897 All type of spray nozzle BI01010001010000000000000515BI0100002009 1 EA
898 898 Supply & welding of SORF Flanges as per ASTM A 105 # Class 150 & as per ANSI B 16.5 (3 runs outside & 1 run inside) of following sizes. BI01010001010000000000000515BI0100002010
899 899 50 mm dia BI01010001010000000000000515BI0100002011 1 EA
900 900 65 mm dia BI01010001010000000000000515BI0100002012 1 EA
901 901 80 mm dia BI01010001010000000000000515BI0100002013 1 EA
902 902 100 mm dia BI01010001010000000000000515BI0100002014 1 EA
903 903 150 mm dia BI01010001010000000000000515BI0100002015 1 EA
904 904 Making flanged joints for both slip on and blind flanges including supplying and fixing 3 mm thk non-metallic gaskets, studs, nuts washers etc., of approved make for the following sizes as per IOC specifications and site instructions. BI01010001010000000000000515BI0100002016
905 905 65 mm dia BI01010001010000000000000515BI0100002017 1 EA
906 906 80 mm dia BI01010001010000000000000515BI0100002018 1 EA
907 907 100 mm dia BI01010001010000000000000515BI0100002019 1 EA
908 908 150 mm dia BI01010001010000000000000515BI0100002020 1 EA
909 909 Supplying the following pipe fittings confirming to ASTM A 234 Gr WPB, Schedule 40, ANSI B 16.9 BI01010001010000000000000515BI0100002021
910 910 90 deg LR bend (1.5D) BI01010001010000000000000515BI0100002022
911 911 65 mm dia BI01010001010000000000000515BI0100002023 1 EA
912 912 80 mm dia BI01010001010000000000000515BI0100002024 1 EA
913 913 100 mm dia BI01010001010000000000000515BI0100002025 1 EA
914 914 150 mm dia BI01010001010000000000000515BI0100002026 1 EA
915 915 45 deg LR bend (1.5D) BI01010001010000000000000515BI0100002027
916 916 65 mm dia BI01010001010000000000000515BI0100002028 1 EA
917 917 80 mm dia BI01010001010000000000000515BI0100002029 1 EA
918 918 100 mm dia BI01010001010000000000000515BI0100002030 1 EA
919 919 150 mm dia BI01010001010000000000000515BI0100002031 1 EA
920 920 Forged/ Fabricated Tee BI01010001010000000000000515BI0100002032
921 921 150 x 150 x 150 mm BI01010001010000000000000515BI0100002033 1 EA
922 922 150 x 150 x 80 mm BI01010001010000000000000515BI0100002034 1 EA
923 923 80 x 80 x 50 mm BI01010001010000000000000515BI0100002035 1 EA
924 924 150 x 150 x 100 x 100 mm - 4 way fabricated plus BI01010001010000000000000515BI0100002036 1 EA
925 925 150 x 150 x 65 x 65 mm - 4 way fabricated plus BI01010001010000000000000515BI0100002037 1 EA
926 926 Supplying following BLRF Flanges as per ASTM A 105 # Class 150 & as per ANSI B 16.5 BI01010001010000000000000515BI0100002038
927 927 80 mm dia BI01010001010000000000000515BI0100002039 1 EA
928 928 100 mm dia BI01010001010000000000000515BI0100002040 1 EA
929 929 150 mm dia BI01010001010000000000000515BI0100002041 1 EA
930 930 Supply & welding of 1/2" NPT one side threaded MS sockets for fixing of sprinkler nozzles on to sprinkler rings BI01010001010000000000000515BI0100002042 1 EA
931 931 Supplying & fixing of 1/2" GI Pipe for fixing spray nozzles at a distance of 600mm from the main header pipe. BI01010001010000000000000515BI0100002043 1 M
932 932 Providing hot dip galvanizing to the following items with minimum 360 gm/sqm as per IS 4736 which include fabricated pipes with flanges, fittings forming part of sprinkler header, raiser & rings inside the tank dyke. BI01010001010000000000000515BI0100002044
933 933 65 mm dia BI01010001010000000000000515BI0100002045 1 M
934 934 80 mm dia BI01010001010000000000000515BI0100002046 1 M
935 935 100 mm dia BI01010001010000000000000515BI0100002047 1 M
936 936 150 mm dia BI01010001010000000000000515BI0100002048 1 M
937 937 200 mm dia BI01010001010000000000000515BI0100002049 1 M
938 938 Supplying and fixing 100 mm dial pressure gauges on the foam/ sprinkler headers including supplying and welding suitable sockets, provision of 3 way gauge cock, necessary tubing etc complete in all respects and as per directions at site. BI01010001010000000000000515BI0100002050 1 EA
939 939 Supplying and fixing 150 mm dial pressure gauges on the foam/ sprinkler headers including supplying and welding suitable sockets, provision of 3 way gauge cock, necessary tubing etc complete in all respects and as per directions at site. BI01010001010000000000000515BI0100002051 1 EA
940 940 MECHANICAL SHOE SEAL (PRIMARY & SECONDARY) BI01010001010000000000000515BI0100002052
941 941 Design, supply and provision of sealing system comprising of Primary Seal of Mechanical Shoe Seal hanger type and Secondary Seal of Rim Mount Viper Type for sealing the rim gap alround the double deck roof of the floating roof vertical tank including supplying & fixing the mechanical shoe seal, providing necessary fixing arrangements, all stud bolts, nuts, fasteners, washers, testing & commissioning for its smooth operation as per manufacturer recommendations, all leads & lifts etc., complete as per specifications and drawings in all respects as per instructions at site. BI01010001010000000000000515BI0100002053
942 942 Note: a) Successful tenderer shall submit detailed drawing from the seal manufacturer including obtaining approval from IOC listed TPI agency as per specifications, BOM for the seal to be installed. BI01010001010000000000000515BI0100002054
943 943 b) Guarantee/ warrantee certificates for the sealing system shall be supplied by the manufacturer directly to IOC as part of the above work. BI01010001010000000000000515BI0100002055
944 944 c) Rate include dismantling of existing foam seal safely without any damage to seal/ tank/ double deck and handing over & stacking the same anywhere in the depot. BI01010001010000000000000515BI0100002056
945 945 For FRVT BI01010001010000000000000515BI0100002057 1 M
946 946 Supply, handling, erection, testing & commissioning of Cast Carbon Steel ASTM - A 216, Gr. WCB Double Flanged Gate Valve as per BS : 1414 ; API-600 , Class # 150, with stainless steel rising spindle & internal working parts, flange drilled as per ANSI B 16.5 Cl # 150,raised face and hand wheel including supply & welding of companion SORF flanges, ANSI B 16.5, Cl # 150, nuts, bolts, gaskets etc., complete in all respect as per instructions. BI01010001010000000000000515BI0100002058
947 947 65 mm dia BI01010001010000000000000515BI0100002059 1 EA
948 948 80 mm dia BI01010001010000000000000515BI0100002060 1 EA
949 949 100 mm dia BI01010001010000000000000515BI0100002061 1 EA
950 950 150 mm dia BI01010001010000000000000515BI0100002062 1 EA
951 951 200 mm dia BI01010001010000000000000515BI0100002063 1 EA
952 952 250 mm dia BI01010001010000000000000515BI0100002064 1 EA
953 953 Supply, handling, cutting, edge preparation, fabrication, welding, erection (under or above ground), supporting, testing & commissioning of S.S. Pipe IS:316 marked, schedule-40, including supply & welding of all necessary S.S. fittings such as elbow, reducer, tee, nipple , socket etc., and S.S. Flanges with S.S.nuts & bolts, gaskets & washers, U-bolts etc., complete in all respect as per the instructions. BI01010001010000000000000515BI0100002065
954 954 25 mm dia BI01010001010000000000000515BI0100002066 1 M
955 955 32 mm dia BI01010001010000000000000515BI0100002067 1 M
956 956 50 mm dia BI01010001010000000000000515BI0100002068 1 M
957 957 65 mm dia BI01010001010000000000000515BI0100002069 1 M
958 958 80 mm dia BI01010001010000000000000515BI0100002070 1 M
959 959 Supply, handling, cutting, edge preparation, fabrication, welding(3 runs minimum), erection (under or above ground), supporting, testing & commissioning of SS pipes of following sizes conforming to ASTM A312 TP 304, Material SS-304 Grade, Sch-40/80 S Seamless with Plain/Bevel end conforming to dimesions ASME B36.19.Including supply & welding of all necessary S.S. fittings such as elbow, reducer, tee, nipple , socket etc., and S.S. Flanges with S.S.nuts & bolts, gaskets & washers, U-bolts etc., complete in all respect as per the instructions. BI01010001010000000000000515BI0100002071
960 960 40 mm NB (SCH 40S Bevel End) BI01010001010000000000000515BI0100002072 1 M
961 961 65 mm NB (SCH 40S Bevel End) BI01010001010000000000000515BI0100002073 1 M
962 962 80 mm NB (SCH 40S Bevel End) BI01010001010000000000000515BI0100002074 1 M
963 963 100 mm NB (SCH 40S Bevel End) BI01010001010000000000000515BI0100002075 1 M
964 964 40 mm NB (SCH 80S Bevel End) BI01010001010000000000000515BI0100002076 1 M
965 965 65 mm NB (SCH 80S Bevel End) BI01010001010000000000000515BI0100002077 1 M
966 966 80 mm NB (SCH 80S Bevel End) BI01010001010000000000000515BI0100002078 1 M
967 967 100 mm NB (SCH 80S Bevel End) BI01010001010000000000000515BI0100002079 1 M
968 968 Supply, handling, erection, testing & commissioning of Female Screwed (BSPT) lever operated Stainless Steel Ball Valve suitable for handling corrosive liquid. The valve should have S.S.body-ASTM A 351 CF 8M,Ball & stem AISI 316,seat test pressure 10kg/sq.cm.The job includes the supply & fittings of all necessary S.S. fittings required etc., complete in all respect as per the instructions. BI01010001010000000000000515BI0100002080
969 969 25 mm dia BI01010001010000000000000515BI0100002081 1 EA
970 970 32 mm dia BI01010001010000000000000515BI0100002082 1 EA
971 971 50 mm dia BI01010001010000000000000515BI0100002083 1 EA
972 972 65 mm dia BI01010001010000000000000515BI0100002084 1 EA
973 973 80 mm dia BI01010001010000000000000515BI0100002085 1 EA
974 974 Supply, handling, erection, testing & commissioning of Class 150 Flanged type Stainless Steel Ball Valve suitable for handling corrosive liquid. The valve should have S.S.body-ASTM A 351 CF 8M,Ball & stem AISI 316,seat test pressure 10kg/sq.cm.The job includes the supply & fittings of all necessary S.S. fittings required etc., complete in all respect as per the instructions. BI01010001010000000000000515BI0100002086
975 975 25 mm dia BI01010001010000000000000515BI0100002087 1 EA
976 976 32 mm dia BI01010001010000000000000515BI0100002088 1 EA
977 977 50 mm dia BI01010001010000000000000515BI0100002089 1 EA
978 978 65 mm dia BI01010001010000000000000515BI0100002090 1 EA
979 979 80 mm dia BI01010001010000000000000515BI0100002091 1 EA
980 980 100 mm dia BI01010001010000000000000515BI0100002092 1 EA
981 981 Supply, handling, erection,testing & commissioning of Stainless Steel Female Screwed (BSPT) horizontal type Non-Return Valve/Check Valve with all S.S.internals ,seat test pressure 10kg/sq.cm. The job includes the supply & fittings of all necessary S.S. fittings required etc., complete in all respect as per the instructions. BI01010001010000000000000515BI0100002093
982 982 25 mm dia BI01010001010000000000000515BI0100002094 1 EA
983 983 32 mm dia BI01010001010000000000000515BI0100002095 1 EA
984 984 50 mm dia BI01010001010000000000000515BI0100002096 1 EA
985 985 65 mm dia BI01010001010000000000000515BI0100002097 1 EA
986 986 80 mm dia BI01010001010000000000000515BI0100002098 1 EA
987 987 Supply, handling, erection,testing & commissioning of Class 150 Flanged type Stainless Steel Non-Return Valve/Check Valve with all S.S.internals ,seat test pressure 10kg/sq.cm. The job includes the supply & fittings of all necessary S.S. fittings required etc., complete in all respect as per the instructions. BI01010001010000000000000515BI0100002099
988 988 25 mm dia BI01010001010000000000000515BI0100002100 1 EA
989 989 32 mm dia BI01010001010000000000000515BI0100002101 1 EA
990 990 50 mm dia BI01010001010000000000000515BI0100002102 1 EA
991 991 65 mm dia BI01010001010000000000000515BI0100002103 1 EA
992 992 80 mm dia BI01010001010000000000000515BI0100002104 1 EA
993 993 100 mm dia BI01010001010000000000000515BI0100002105 1 EA
994 994 OTHER WORKS BI01010001010000000000000515BI0100002106
995 995 Supplying & Providing cathodic protection sacrificial Anode of the bottom plate including design, supply, fixing of the same as per requirement and instruction at site. BI01010001010000000000000515BI0100002107
996 996 For vertical tanks BI01010001010000000000000515BI0100002108 1 EA
997 997 Supply of Standard Reference Electrodes \n(Cu-CuSO4 half cell or CalomelReference\nCell or Silver-Silver Chloride Cell or\nZinc Reference Cell)with insulated \ncopper wires & appropriate mounting\narrangements in MSstructural frame/\nclamps etc BI01010001010000000000000515BI0100002109 1 SET
998 998 Supply of Terminal Box powder coated\nwith IP 67 enclosure, ISI MarkedDigital\nmeter with a sensitivity of (+/-)\nVolts inlcuding pushbutton with\nmultiway selector switch including\nnecessary mountingarrangement in MS\nstructural frame/ clamps etc BI01010001010000000000000515BI0100002110 1 SET
999 999 Installation of supplied Standard \nReference Electrodes at the top of\nthetank by welding the mounting\narrangement etc BI01010001010000000000000515BI0100002111 1 SET
1000 1000 Installation of supplied Terminal box by welding/ clamping at top of thetank BI01010001010000000000000515BI0100002112 1 SET
1001 1001 Providing detailed engineering documentation comprisng of the following drawings & documentation in 3 sets:\na. Water conductivity test report inclduing temperature variations\nb. Design basis & calculations including surface area, current demand, current drain as applicable\nc. Minimum net mass of Anode\nd. Anode resistance calculations\ne. Current output calculations\nf. Anode installation design & arrangement\ng. Provision for electrical continuity checking\nh. Any other required documentation BI01010001010000000000000515BI0100002113 1 LS
1002 1002 Arranging for visit from OEM of\nSacrifical Anode system\nduringcommissioning of water tanks for\nconducting testing inlcuding\nelectricalcontinuity, current output/\ndrain, anode resistance,\ncathodicpolarization. Charges shall\ninclude boarding, lodging,\nair/rail/roadtransportation, insurance,\nlocal conveyance, communication,\nstationery& all other incidentals\nrequired for performance of the testing\n&submission of reports to IOCL. Item is\nbased on visit of 1 no Enigneerfrom OEM\nfor a day BI01010001010000000000000515BI0100002114 1 LS
1003 1003 Supply & Installation, testing, commissioning & customization of Fall arrestor system with Safety harness, complete. For ensuring correct\ninstallation, horizontal life line shall be proof loaded at site to a static force of 6 KN by the vendor.\nTank Lorry Filling (TLF) bays, Tank Truck (TT) sealing gantry, TT surprise check gantry: THE WORK INCLUDES SUPPLY & INSTALLATION of horizontal\nlifeline with accessories for Fall arrestor system including 1 no. Shock absorber (SS 304 to limit impact force in event of fall to less than 6.5 KN),\nUpto 10 m Steel wire rope (minimum 8 mm dia of SS 316), 2 no. Retractable fall arrestor (with SS wire rope of 4.5 mm dia & length as required at\nsite), 2 no. Carriage body (SS 316 with friction free movement), 1 no. Tensioner (SS 304 with swageless termination of end wire), 2 no. Extremity\nplates, 1 no. Cable extremity (if required), 2 no. Anti static Full body adjustable harness & any other material to complete the job. Fall arrestor\nsystem shall be provided in TLF bays, TT calibration area, and Surprise Checking Platform, as required at the location & as mentioned in the\ntender. Items shall be provided in line with the material specifications as mentioned in attached 'Data Sheet'. The above requirement is typical\nand vendor shall provide the site specific quantities and any additional items required for efficient working of the system at no extra cost. ITEM\nALSO INCLUDES Customisation and installation of horizontal life line system on the gantry BI01010001010000000000000515BI0100002115 1 EA
1004 1004 Design, Supply,Installation,Testing & Commissioning of Retractable stairs for Tank Wagon Decanting Gantry at Railway siding as per IOCL technical specification and drawings. The item includes packing/forwarding, freight with transit Insurance and TPI charges BI01010001010000000000000515BI0100002116 1 EA
1005 1005 Design, Supply,Installation,Testing & Commissioning of Retractable stairs for Tank Lorry Filling Gantry at TLF shed, TT calibration facility, TT checking facility etc. as per IOCL technical specification and drawings. The item includes packing/forwarding, freight with transit Insurance and TPI charges BI01010001010000000000000515BI0100002117 1 EA
1006 1006 Cuting and removing the roof eye bolts and re-placeing the same as per the drawing after welding of patch plate on the roof. The job include supply of 20 mm dia eye bolts etc complete as per instruction at site engineer. BI01010001010000000000000515BI0100002118
1007 1007 NOTE : Care should be taken not to damage any part of the tank while dismantling. Welding of patch plate will be paid as per the respective items in this workorder. BI01010001010000000000000515BI0100002119
1008 1008 For vertical tanks BI01010001010000000000000515BI0100002120 1 EA
1009 1009 Fabricating, erecting, welding of 5 mm thk MS patch plate on roof of Cone Roof Vertical Tank as per the specifications with required steel plates supplied by IOC any where within the premises. All other items such as labour, equipment, power, consumables etc., shall be supplied by the Contractor. BI01010001010000000000000515BI0100002121
1010 1010 For vertical tanks - upto 300mmx300mm size BI01010001010000000000000515BI0100002122 1 EA
1011 1011 Transportation of materials like MS plates/ MS Pipes/ Valves including arranging truck, manpower, equipments, all leads & lifts, taking necessary insurance for materials, co-ordination, loading & unloading, stacking etc., complete as per instructions. BI01010001010000000000000515BI0100002123
1012 1012 Between 0 to 100 KMs BI01010001010000000000000515BI0100002124
1013 1013 MS Plates/ MS Pipes - all thickness/ all dia BI01010001010000000000000515BI0100002125 1 TON
1014 1014 All types of Valves - 150mm to 600mm size BI01010001010000000000000515BI0100002126 1 EA
1015 1015 Every additional KM above 100 KMs BI01010001010000000000000515BI0100002127
1016 1016 MS Plates/ MS Pipes - all thickness/ all dia BI01010001010000000000000515BI0100002128 1 KM
1017 1017 All types of Valves - 150mm to 600mm size BI01010001010000000000000515BI0100002129 1 KM
1018 1018 Transportation of materials like MS plates/ MS Pipes including arranging trailor, manpower, equipments, all leads & lifts, taking necessary insurance for materials, co-ordination, loading & unloading, stacking etc., complete as per instructions. BI01010001010000000000000515BI0100002130
1019 1019 Between 0 to 100 KMs BI01010001010000000000000515BI0100002131
1020 1020 MS Plates/ MS Pipes - all thickness/ all dia BI01010001010000000000000515BI0100002132 1 TON
1021 1021 Every additional KM above 100 KMs BI01010001010000000000000515BI0100002133
1022 1022 MS Plates/ MS Pipes - all thickness/ all dia BI01010001010000000000000515BI0100002134 1 KM
1023 1023 Providing 8 guage copper wire bonding for the flange joints BI01010001010000000000000515BI0100002135 1 EA
1024 1024 Dismantling and re-fixing the existing MS structural catwalk with grating without any damage including cutting, welding, stacking the same safely, re-fixing the same wherever required, necessary grouting, all leads & lifts etc., complete in all respects as per instructions. BI01010001010000000000000515BI0100002136
1025 1025 Old Catwalk with gratings BI01010001010000000000000515BI0100002137 1 M2
1026 1026 Supplying and providing stand post on the exisitng Fire Hydrant line including suppy of MS pipe, reinforcement plate, cutting, welding, SORF flange, all leads & lifts etc., complete as per specification & instructions. BI01010001010000000000000515BI0100002138
1027 1027 80mm dia BI01010001010000000000000515BI0100002139 1 EA
1028 1028 100mm dia BI01010001010000000000000515BI0100002140 1 EA
1029 1029 Pipeline Identification and marking using suitable Pipeline Locator, measuring distances, GPS tracking, Conducting CIPS and DCVG Survey. Collection of data and compiling with respect to pipeline / ROW features / references, calculation of %IR Loss, bell hole inspection and repair, identification of coating holidays and prioritization for coating refurbishment - for all dia of pipelines. BI01010001010000000000000515BI0100002141
1030 1030 DCVG Survey as per procedure outlined in the tender document including installation of temporary CP for the purpose, if required - survey for every 1 M interval. BI01010001010000000000000515BI0100002142 1 KM
1031 1031 CIPS Survey as per procedure outlined in the tender document for cathodically protected pipelines only - survey for every 1 M interval. BI01010001010000000000000515BI0100002143 1 KM
1032 1032 Verification of defect spots by Bell Hole inspection as per procedure outlined in the tender document . BI01010001010000000000000515BI0100002144 1 EA
1033 1033 Repair of defect spot exposed through bell hole inspection using vendor supplied Cold Applied Tape as per procedure outlined in the tender document . BI01010001010000000000000515BI0100002145 1 EA
1034 1034 Carrying out ultrasonic thickness survey for the pipelines for various dia (Spot shall have 4 readings i.e. 12 O'Clock, 3 O'Clock, 6 O'Clock & 9 O'Clock) with necessary ultrasonic thickness gauge, man power, tools & tackles, transportaion etc., leasd & lifts wherever required including submission of reports as per requirements and instructions. BI01010001010000000000000515BI0100002146
1035 1035 Above ground pipelines of all dia. BI01010001010000000000000515BI0100002147 1 EA
1036 1036 Under ground pipeline of all dia upto 2M depth - including earth work excavation & back filling. BI01010001010000000000000515BI0100002148 1 EA
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail