Water Supply And Sanitation Department-WSSD has published Augmentation Of Water Supply Scheme Village Sukhani, Block Kapurthala, Distt. Kapurthala. (Under Prwssip 1A(Iii)/ Jjm)Providing And Installing Deep Tubewell 150Mm I/D Straight 80Mtr Deep With 10Mtr Stainless Strainer With Hand Boring, Pumping Machinery, . Submission Date for this Tender is 01-07-2021. Tanks and Cylinders Tenders in Water Supply and Sanitation Division, Kapurthala Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Jun-2021 | Date extend 01.07.2021 | Date | 01-07-2021 |
Name of Work: Augmentation of Water Supply Scheme Village Sukhani, Block Kapurthala, Distt. Kapurthala. (UNDER PRWSSIP 1a(iii)/ JJM) "Providing and Installing deep tubewell 150mm i/d straight 80mtr deep with 10mtr Stainless strainer with Hand Boring, Pumping Machinery, Disinfection Unit Electronically actuated Type, Const. of Pump Chamber 2.20 x 2.20m, Construction of 1 No. OHSR 15KL capacity having height of 15.00m upto FSL including the cost of inlet, outlet, overflow & scour & vertical pipes, DI duck foot bends, expansion joints, puddle collar, lightening conductor, earthing, MS steel ladder of tank portion stair case with G.I pipe railing on both sides Ventilation Aluminium Ladder inside OHSR, Scour/overflow Sluice valves and making connections with rising main and distribution pipe line. All Civil Works, Supplying and laying of PVC pipes, Sluice valves and specials for Rising Main and Distribution System etc. Household connection with water meter and Solar Panel Energy System complete in all respects." Operation and Maintenance water supply system including machinery , Pump Operator cum- Chowkidar, Sodium Hypo Chloride solution with storage tank of sufficient disinfection for 3 months after completion and environment management at water work site. | |||||
---|---|---|---|---|---|
Sl. No. | Description of item (with brief specification and reference to book of specification) | Item Code / Make | Quantity | Units | |
1 | 1 | Hand Boring Tubewell | t1 | ||
2 | 2 | Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. | t2 | ||
3 | 3 | Boring with 200mm id Housing pipe upto 150m depth BGL | t3 | 80 | mtr |
4 | 4 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. | t4 | ||
5 | 5 | 150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness. | t5 | 66 | mtr |
6 | 6 | Supplying, fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked, duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore. | t6 | ||
7 | 7 | 150mm Steel Strainer (slot size 0.20mm) 5.00 mm thickness | t7 | 10 | mtr |
8 | 8 | Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest ISI marked duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore complete in all respect. | t8 | ||
9 | 9 | 150mm Internal diameter | t9 | 6 | Each |
10 | 10 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. | t10 | ||
11 | 11 | 150mm internal diameter | t11 | 4 | Each |
12 | 12 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. | t12 | 1 | Each |
13 | 13 | Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. | t13 | 1 | Each |
14 | 14 | Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect. | t14 | ||
15 | 15 | 150mm internal diameter (weight 21.6 kg per metre) 5.4 mm thickness | t15 | 4 | mtr |
16 | 16 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. | t16 | ||
17 | 17 | 150mm internal diameter | t17 | 1 | Each |
18 | 18 | Development and Stabilizing of the tubwell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. | t18 | ||
19 | 19 | Capacity of Air compressor 300 cfm at 250 PSI | t19 | 10 | hours |
20 | 20 | Development and Stabilizing of the tubwell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. | t20 | 8 | Hours |
21 | 21 | Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) | t21 | 3 | Each |
22 | 22 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) | t22 | 1 | Each |
23 | 23 | Provision for Sanitary clay seal (as per BIS Code IS 2800:2019) including sterilization of tubewell. | t23 | 1 | Job |
24 | 24 | OHSR | t24 | ||
25 | 25 | Constructing one No. of 15 KL (15000 litres) Capacity with sill level not less than 13.00m height upto FSL 15.00 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing C.I D/F expansion joints or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and C.I D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow C.I double flanged pressure pipes horizontally as per IS:7181/1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including overflow scower haudi complete in all respects including Supplying, fixing and testing at site automatic Electronic Water Level indication system with gun metal float sensor and electrical cable suitable for three phase pump submerisble/ monoblock to be fixed on existing panel for OHSRs complete in all respects including Construction of plinth protection around OHSR with masonry toe wall & inside earth filling 40mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 complete in all respects. | t25 | 1 | Each |
26 | 26 | Rising Main | t26 | ||
27 | 27 | Providing, Laying, fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenhes to correct alignment and gradients, cutting, jointing and testing complete as per specifications.\nFor more than 3 mtr street width For Mechanically Excavation including specials | t27 | ||
28 | 28 | 90mm o/d pipe of 10 kgf. / sqcm | t28 | 15 | Mtr |
29 | 29 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) | t29 | ||
30 | 30 | Class PN-1 as per ISI | t30 | ||
31 | 31 | Note:- 1 No S.V. for Pumping main and 4 No S.V. for distribution system | t31 | ||
32 | 32 | 80mm i/d Sluice Valves flanged | t32 | 5 | Each |
33 | 33 | Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department | t33 | ||
34 | 34 | Note:- 1 No S.V. Chamber for Pumping main and 4 No S.V. Chamber for distribution system | t34 | ||
35 | 35 | Size 0.6m. X 0.6m. | t35 | 5 | Each |
36 | 36 | Distribution System | t36 | ||
37 | 37 | Providing, Laying, fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenhes to correct alignment and gradients, cutting, jointing and testing complete as per specifications for more than 3 mtr street width 6kg/cm2. For Mechanically Excavation including specials | t37 | ||
38 | 38 | 63mm o/d pipe of 6 kg. / sqcm | t38 | 1747 | Mtr |
39 | 39 | 90mm o/d pipe of 6 kg. / sqcm | t39 | 303 | Mtr |
40 | 40 | Providing, Laying, fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenhes to correct alignment and gradients, cutting, jointing and testing complete as per specifications.\nFor Less than 3 mtr street width Manual Excavation including specials | t40 | ||
41 | 41 | 63mm o/d pipe of 6 kg. / sqcm | t41 | 159 | Mtr |
42 | 42 | 90mm o/d pipe of 6 kg. / sqcm | t42 | 64 | Mtr |
43 | 43 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. | t43 | ||
44 | 44 | For CC Flooring | t44 | ||
45 | 45 | G.I Pipe 20mm i/d | t45 | 27 | Mtr |
46 | 46 | G.I Pipe 25mm i/d | t46 | 474 | Mtr |
47 | 47 | Connection with New PVC Pipe to GI Pipe complete in all respect. | t47 | 4 | Each |
48 | 48 | Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position | t48 | ||
49 | 49 | 63mm o/d pipe of 6 kgf. / sqcm | t49 | 1146 | Mtr |
50 | 50 | 90mm o/d pipe of 6 kgf. / sqcm | t50 | 86 | Mtr |
51 | 51 | Dismantling of interlock tile 80mm thick cement concrete interlocking paver block as per analysis attached including Refixing of interlock tile 80mm thick cement concrete interlocking paver block of M-40 grade machine made rubber moulded smooth finish by strong vibratory process or with vibro-hydraulic compaction machine and of approved size and design/ shape laid in ordinary grey color and pattern over including 40mm thick | t51 | ||
52 | 52 | 63mm o/d PVC pipe | t52 | 122 | Mtr |
53 | 53 | 90mm o/d PVC pipe | t53 | 94 | Mtr |
54 | 54 | House Hold Connections for PVC Pipe with Water Meter | t54 | ||
55 | 55 | Providing proposed water connection with multijet water meter to house hold up to wall with providing, laying, jointing, testing GI pipe lines 15mm i/d = 2.50 mtr (B-Class), (above GL), Providing & fixing MDPE pipe 15mm i/d with speicals 2.00 mtr (Below GL), including cost of specials such as tees, bend, socket, elbow, peet valve, union, Nipple and hook etc. cutting and threading testing in trenches in the ground and ISI 15mm i/d GM furrule as per IS:2692 and 3 inches i/d clamp with C.I. bib cock, 15mm i/d as per IS:210 with stainless steel spindle of approved make. | t55 | 83 | Each |
56 | 56 | Disinfection Unit | t56 | ||
57 | 57 | Disinfection Unit Providing Installing, testing & commissioning one no. Electronically actuated, Diaphragm operated, Metering System, Chemical Dosing, Chlorinator, Suitable for delivering 0.5 to 6 Litres fo Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg. cm2 and suction lift not less than 1.5 m, as per DWSS standard specifications | t57 | 1 | Each |
58 | 58 | Solar Panel Energy System | t58 | ||
59 | 59 | Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects. | t59 | 0.98 | KW |
60 | 60 | Pump Chamber | t60 | ||
61 | 61 | Construction of Pump Chamber size 2.2 m x 2.2 m including cost of & electric wiring complete in all respect. | t61 | 1 | Job |
62 | 62 | Pumping Machinery | t62 | ||
63 | 63 | Providing & installing, testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 69LPM against a head of 54mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps, Kit-Kat etc., including GI column Pipe 40mm i/d of IS: 1239-2004 medium class suitable size 35mtr(in 3mtr lengths each with flanges, screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable 85 mtr 2.50mm2 IS694-1990 reaffirmed 2000 complete in all respects and as per standard specifications. | t63 | ||
64 | 64 | (Motor with Pump) 69LPM, 54mtr Head | t64 | 1 | Each |
65 | 65 | Panel Board | t65 | 1 | Each |
66 | 66 | Cable (Size/Cost) 2.50mm2 | t66 | 85 | mtr |
67 | 67 | Column Pipe (G.I) ( Size/Length) 40mm i/d | t67 | 35 | mtr |
68 | 68 | D.I Fitting Inside Pump Chamber | t68 | ||
69 | 69 | Providing and installing 80mm dia delivery main (From Tube well to Duck Foot bend including cost of D.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as D.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects. | t69 | 1 | Job |
70 | 70 | Development of Head Works | t70 | ||
71 | 71 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing | t71 | 399 | mtr |
72 | 72 | Providing and fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI makred) wire 4mm dia fencing pole size at bottom 4" x 4", size top 3" x 4", length 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respect | t72 | 54 | Each |
73 | 73 | Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing | t73 | 30 | Each |
74 | 74 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material as per standard Drawing complete in all respects . | t74 | 4 | Each |
75 | 75 | Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing complete in all respects. | t75 | 1 | Each |
76 | 76 | Construction of Cement Concrete Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing complete in all respect. | t76 | 20 | mtr |
77 | 77 | Providing & fixing MS Sign Board as per standard size of DWSS as per standard Drawing | t77 | 1 | Each |
78 | 78 | Operation & Maintenance Cost | t78 | ||
79 | 79 | Operation and Maintenance water supply system for 3 Months including operating of machinery, repair of leakages (if any), supplying of full time Pump Operator cum- Chowkidar, supply of Sodium HypoChloride solution for disinfection for 3 months after completion. | t79 | 1 | Job |
80 | 80 | Environment Management | t80 | ||
81 | 81 | Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil. | t81 | 90 | Sqm |
82 | 82 | Supplying and planting permanent trees in prepared pits and watering | t82 | 3 | Each |
83 | 83 | Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row. | t83 | 3 | Sqm |
84 | 84 | Planting seasonal flower in beds | t84 | ||
85 | 85 | Planting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row. | t85 | 3 | Sqm |
86 | 86 | Provision for one way stand post with khura complete in all respects. | t86 | 1 | Job |
87 | 87 | Carriage of Material such as bajri and sand upto lead 126 km complete in all respect | t87 | 1 | Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail