Providing 50Kwp Roof-Top Hybrid Solar Power Plant At District Hospital, Sonapur, Kamrup ( Metro ) , Sonapur-Assam

Public Works Department-PWD has published Providing 50Kwp Roof-Top Hybrid Solar Power Plant At District Hospital, Sonapur, Kamrup ( Metro ) . Submission Date for this Tender is 22-06-2021. Solar Power Plants Tenders in Sonapur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28207566
Providing 50Kwp Roof-Top Hybrid Solar Power Plant At District Hospital, Sonapur, Kamrup ( Metro )
Open Tender
Indian
Assam
Sonapur
22-06-2021

Tender Details

Providing 50Kwp Roof-Top Hybrid Solar Power Plant At District Hospital, Sonapur, Kamrup ( Metro )

Key Value

Document Fees
INR 3700 /-
EMD
INR 246100.0 /-
Tender Value
INR 1.23 Crore /-

BOQ Items

Name of Work:Providing 50KWP roof-top hybrid solar power plant at District Hospital, Sonapur, Kamrup (Metro).
Sl. No. Item Description
1Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedPVCconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.). With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
2Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
3Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
4Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
5Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
6Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake) 12 way SPN double door
7Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hagermake) 4way TPN (4+12)double door
8Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. "C Series (Schneider MG, legrand, Hagermake)" 6-32A
9Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4PRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. " 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hagermake)" 40A
10Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4PRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. " 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hagermake)" 63A
11Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DPRCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. " 30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hagermake)" 40A
12Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch,through medium duty G.I. pipe(Tata/ Nezonemake or equivalent as approved by the Deptt)bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 & 1/2 A2XWY A2XFY 70.00 Sq.mm 3&1/2 Core U.G. cable in50mm dia medium duty G.I. pipe
13Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.35M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 6nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 1. 20mm X 3mm4 strip copper Bus-Bar 0.6 M length each 2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no 3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 no 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 5. Voltmeter & Ammeter Selector Switch- 2 no 6. 2 A Slide fuse unit - 3nos (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
14Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hagermake) 63A
15Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. "25 KA 415V 50 Hz 3P MCCB (Schneider, legrand, Siemensmake)" 125A
16Supply installtion testing and comissioning of 50KW solar Hybrid Rooftop power plant with required no. of batteries and civil structures. *(Supply of solar materials including testing and commissioning of the plant).
17Supply installtion testing and comissioning of 50KW solar Hybrid Rooftop power plant with required no. of batteries and civil structures. *( Civil structural works).