Delhi Development Authority-DDA has published Maintenance Of Complete Schemes Under Flyover Civil ( Fod-1 And 3 ) Elect . ( Eld-3 And 10 ) Horticulture . Running Operation And Maintenance Of 11 Kv/433V Substation , 1250 And 320 Kva Dg Set , Tunnel And High Mast Lighting , Dewatering Pump Se. Submission Date for this Tender is 30-06-2021. Diesel Generators Tenders in As Per Tender Document Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

28197597
Corrigendum : Maintenance Of Complete Schemes Under Flyover Civil ( Fod-1 And 3 ) Elect . ( Eld-3 And 10 ) Horticulture . Running Operation And Maintenance Of 11 Kv/433V Substation , 1250 And 320 Kva Dg Set , Tunnel And High Mast Lighting , Dewatering Pump Se
Open Tender
Indian
Delhi
As Per Tender Document
30-06-2021

Tender Details

Maintenance Of Complete Schemes Under Flyover Civil ( Fod-1 And 3 ) Elect . ( Eld-3 And 10 ) Horticulture . Running Operation And Maintenance Of 11 Kv / 433V Substation , 1250 And 320 Kva Dg Set , Tunnel And High Mast Lighting , Dewatering Pump Sets And Ei And Fans Of Substation And Office Building ( F . O . D . -4 ) At Sarita Vihar Underpass .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Jun-2021 Corrigendum for rescheduling of Pre-bid meeting and bid submission end date Date 30-06-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: : M/o complete schemes under flyover civil (FOD-1 & 3) Elect (ELD-3 & 10) Horticulture. Sub Head :: Running operation & maintenance of 11 KV/433V Sub station,1250/320 KVA DG Set, Tunnel/ High Mast Lighting, Dewatering pump sets and EI & fans of sub station and office building (F.O.D.-4) at Sarita Vihar underpass.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Running maintenance and operation i/c routine & preventive maintenance of all water pump sets installed at site by deploying 3 nos skilled & trained pump operators for 9 Months (1 no. in each shift for total 3 shifts i.e. 6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM) and 9 Nos skilled & trained pump oprators for 3 months ( 3 no. in each shift for total 3 shifts i.e. 6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM) . One no wireman having competency certificate at least Class 2 & trained in maintenance of pumping installations once in a week (general shift 9 AM to 5 PM) & One no fitter trained in maintenance of pumping installations once in a week (general shift 9 AM to 5 PM) as per additional conditions, special conditions & inventory attached as per Annexure-'C' etc as required.\nNote: Daily, weekly, fortnightly, monthly & other periodical checks as per CPWD Schedule of maintenance shall be carried as routine / preventive maintenance. \n\n 1 12 Month
2 2 Running maintenance and operation i/c routine & preventive maintenance of substation equipments and Diesel generating set by deploying 3 nos skilled & trained electricians ,1 no. in each shift (total 3 shifts i.e. 6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM), one no Khallasi for once in a week (general shift 9 AM to 5 PM), one no foreman (Electrical /Mechanical) once in month ( i.e. one M/o substation in 1st month and M/o DG set in 2nd month and so on), (general shift 9 AM to 5 PM) as per additional conditions, special conditions & inventory attached as per Annexure-'C' etc as required.\nNote: Daily, weekly, fortnightly, monthly & other periodical checks as per CPWD Schedule of maintenance shall be carried as routine / preventive maintenance including periodical testing of transformer oil, dehydration (Once in a year) & testing / calibration once in year etc. For DG set;- Daily, weekly, fortnightly, monthly & other periodical checks as per CPWD Schedule of maintenance shall be carried as routine / preventive maintenance including servicing, topping up of mobile oil/ water etc.\n 2 12 Month
3 3 Running maintenance and operation including routine & preventive maintenance of high mast lighting and tunnel lighting system by deploying 1 nos wireman having at least competency certificate class 2 and trained in maintenance of high mast lighting once in a week (general shift 9 AM to 5 PM) and 1 no mechanic trained in maintenance of high mast lighting once in a week (general shift 9 AM to 5 PM )as per additional conditions, special conditions & inventory attached as per Annexure-'C' etc as required.\nNote: Daily, weekly, fortnightly, monthly & other periodical checks as per CPWD Schedule of maintenance shall be carried as routine / preventive maintenance.\n 3 12 Month
4 4 Running maintenance including routine / preventive maintenance of IEI and fans i/c repairing and supplying replacement of defective parts i.e copper ballast, lamps, T-5 rod etc of sub-station i/c UPS and office bulding of FOD-4 by deploying 1 nos wireman having atleast competancy certificate class 2 once in a week (general shift 9 AM to 5 PM) and 1 no Khallasi once in a week (general shift 9 AM to 5 PM ) as per additional conditions, special conditions & inventory attached as per Annexure-'C' & 'D' etc as required.\nNote: Daily, weekly, fortnightly, monthly & other periodical checks as per CPWD Schedule of maintenance shall be carried as routine / preventive maintenance. \n 4 12 Month
5 5 Comprehensive material for maintenace of following system as per detailed inventory attached, as per Annexure 'C', including repair / replacement of any part of parts to the original finish & performance required for fully functional system for original system requiremnet etc. as required. \nStorm and sewage water pumps 5 12 Month
6 5.01 Substation equipment 6 12 Month
7 5.02 High Mast Lighting 7 12 Month
8 5.03 Tunnel Lights 8 12 Month
9 6 Providing supervisor for (having minimum graduate qualified) daily monitoring & supervision and ensure logging of operation / maintenance staff, attending routine, preventive & breakdown maintenance. \nNote: The supervisor must be minimum graduate qualified.\n 9 12 Month
10 7 B' check Servicing of 1250 KVA capacity D.G. set (cummins make) including replacement of following material, connection, testing etc. as required. \nELEMENT LUB OIL FILTER 10 4 Each
11 7.01 KIT FUEL FILTER AND RING 11 2 Each
12 7.02 KIT SUPER BYP.FILTER ELEM 12 2 Each
13 7.03 "SEAL,O RING" 13 2 Each
14 7.04 INHIBITOR,CORROSION 10 LITERS 14 1 Each
15 7.05 STRIP TEST 15 1 Each
16 7.06 KIT AIR CLEANER ELEMENTS (K, QSK, V SERIES) 16 2 Each
17 7.07 VALVOLINE PREMIUM BLUE 7800 PLUS 1/210 LTR 17 1 Each
18 8 B' check Servicing of 320 KVA capacity D.G. set (Kirloskar make) including replacement of following material, connection, testing etc. as required. \nFUEL FILTER CATRIGE 18 2 Each
19 8.02 SOINON ASSEMBL KIT 19 1 Each
20 8.03 LUB OIL FILTER 20 1 Each
21 8.04 LUB OIL FILTER - WITH KIRLOSKAR 21 1 Each
22 8.05 KOEL CARE\nGenuine Oil Premium 20 Litres Can\n 22 2 Each
23 9 Supplying of following size XLPE insulated PVC sheathed Aluminum Conductor Armoured power Cable (including rebate for old/replaced cable) of 1.1 KV grade including testing etc. complete as required. \n3 1/2 X 185 sq. mm 23 200 Meter
24 9.01 3 1/2 X 120 sq. mm 24 400 Meter
25 9.02 4 x 25 sq mm 25 400 Meter
26 10 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but\nexcluding sand cushioning and protective covering.\nAbove 95 sq. mm and upto 185 sq. mm .\n 26 600 Meter
27 10.01 Upto 35 sq. mm 27 400 Meter
28 11 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.\n3½ X 120 sq. mm 28 4 Each
29 11.01 3½ X 185 sq. m 29 4 Each
30 11.02 4 X 25 Sq mm 30 4 Each