Supply Installation And Commissioning Of Flow Meter Alongwith Rtu At 5 . 5 Mld Stp Jhajjar At Kosli Road Upgradation Of Existing 5 . 5 Mld And 5 Mld Stps ( Mbbr Tech . ) Followed By Tt And Chlorination Alongwith Balance Pipe Line Of Jhajjar Town Supply, Jhajjar-Haryana

Public Health Engineering Department-PHED has published Supply Installation And Commissioning Of Flow Meter Alongwith Rtu At 5 . 5 Mld Stp Jhajjar At Kosli Road Upgradation Of Existing 5 . 5 Mld And 5 Mld Stps ( Mbbr Tech . ) Followed By Tt And Chlorination Alongwith Balance Pipe Line Of Jhajjar Town Supply. Submission Date for this Tender is 23-06-2021. Pipe Laying Tenders in Jhajjar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

28192038
Corrigendum : Supply Installation And Commissioning Of Flow Meter Alongwith Rtu At 5 . 5 Mld Stp Jhajjar At Kosli Road Upgradation Of Existing 5 . 5 Mld And 5 Mld Stps ( Mbbr Tech . ) Followed By Tt And Chlorination Alongwith Balance Pipe Line Of Jhajjar Town Supply
Open Tender
Indian
Haryana
Jhajjar
23-06-2021

Tender Details

Supply Installation And Commissioning Of Flow Meter Alongwith Rtu At 5 . 5 Mld Stp Jhajjar At Kosli Road Upgradation Of Existing 5 . 5 Mld And 5 Mld Stps ( Mbbr Tech . ) Followed By Tt And Chlorination Alongwith Balance Pipe Line Of Jhajjar Town Supply Installation And Commissioning Of Flow Meter Alongwith Rtu At 5 . 5 Mld Stp Jhajjar At Kosli Road And All

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Jun-2021 Revised item Technical Bid 23-06-2021

Key Value

Document Fees
INR 1000 /-
EMD
INR 13960.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Upgradation of existing 5.5 MLD and 5 MLD STPs (MBBR Tech.) followed by TT and chlorination alongwith balance pipe line of Jhajjar Town.” Supply, Installation and commissioning of flow meter alongwith RTU at 5.5 MLD STP Jhajjar at Kosli Road and all other works contingent thereto.”
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply of Electromagnetic Flow Meter Model No. 151 MFM W R 4220 N 4503 D1361428P W: Accuracy Class & Display:± 0.5% of measured flow; 2 Line LCD R: Indicator Converter Type: Remote, field mounted 4: Power Supply: Universal Power Supply 85 to 265VAC@45 to 65 Hz or 24 VDC 2: Outpur: 4 to 20mA 2: Communication Interface: RS 485 (MODBUS RTU) 0: Data Logger: Not Applicable N: Cable Entry: 1/2"NPT 0450: Sensor Size (mm) : 450 mm 3: Pressure Rating (Kg/cm²): 16 Kg/cm² D: Design off the Measuring Sensor: Flanged DIN 1: Flange Material: CS 3: Sensor Lining: HD 6: Electrode Material: SS316 1: Earthing ring: None, With built-inearthing electrode, 4: Measuring Tube: SS304 2: Coil Housing: CS 8: Protection Class for Sensor: IP68 P: Approval: Non Hazardous area Cable L= 20 mtrs. Make - Siemens, SBEM, Rosemount, Honywel (As per Analysis) BI01010001010000000000000515BI0100001113 1 No.
2 2 Supply of Ultrasonic Type Open Channel Flow meter to be installed on open channel with display, Input Power Supply 24VDC, 2 Wire Transmitter, HART Protocol, Output: 4-20mA, Process connection: 1 ½" BSP Threaded, Simens, SBEM, Rosemount, Honywel. BI01010001010000000000000515BI0100001114 1 No.
3 3 Supply, Fixing, Testting & Commissioning of Remote Terminal Unit with power analyzer having inbuilt GSM/GPRS modem. iRTU configguration is 6 Digital inputs, 2 Digital Outputs & 2 Anolog Inputs. iRTU installation inside a panel having isolattion transformer, RTU suitable for multi parameter ffor transferring data to MCS complete in all respect. Make Siemens, CIMCON, Rosemount, Honywel. (As perr Analysis) BI01010001010000000000000515BI0100001115 2 Nos.
4 4 Installation & accessories like Cabing as per site requirements, Panel Box etc. Commissioning Charges of Flow Meter, Configurations s per sitte requirements & making connection witth the existing SCADA software, Head Office, HSPCB & CPCB to the satisfaction of Engineer-In-Charge, including one year maintenance charges. (As per Analysis) BI01010001010000000000000515BI0100001116 2 Nos.
5 5 Commissioning Charges of Open Channel Flow Meter & accessories required for installation of Open Channel Flow Meter, Customization and programming of flow meter as per channel dimensions, Configuration as per sitte requirements & making connection with the existing SCADA software/Head Office, to the stisfacton of Enggineering-In-Charge, including one year maintenance charges. BI01010001010000000000000515BI0100001117 1 No.
6 6 Supply, Fixing, Testingg & Commissioning of DI fitting required for installation of full bore electomagnetic flow meter complette in all respect to make the flow meter leakage proof. The DI fitting should be duly ISI marked as per IS: 9523-2000 (K-12) (PN-10) (Size 450mm) 1. Flanged socket including the cost of nut bolt rubber ring etc. 2. Flange SPIGOT (Tail Pcs) including the cost of nut bolt rubberr ring etc. BI01010001010000000000000515BI0100001118 2 Nos