Urban Improvement Trust-UIT has published Construction Of Shops At Various Places In Rampura And Sabjimandi Area , Kota . Civil Work. Submission Date for this Tender is 24-06-2021. Building Work Tenders in Kota Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work: Construction of Shops at Various Places in Rampura and Sabjimandi Area, Kota. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils | 983.8 | Cum | |
2 | 2 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix\n1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). | 97.85 | Cum | |
3 | 3 | Supplying and Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand | 66.15 | Cum | |
4 | 4 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). | 202.5 | Cum | |
5 | 5 | Flyash Flyash Brick work with flyash Flyash Bricks of class designation 75 in superstructure above plinth level upto floor Three Level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) | 323.44 | Cum | |
6 | 6 | Centering and Shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. | 211.5 | Sqm | |
7 | 7 | Centering & shuttering with plywood or steel Plate including strutting, propping bracing both ways with steel props and removal of formwork for upto floor Three level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. | 438.75 | Sqm | |
8 | 8 | Centering & shuttering with plywood or steel Plate including strutting, propping bracing both ways with steel props and removal of formwork for upto floor Three level for : Columns, pillars, posts and struts etc. | 612 | Sqm | |
9 | 9 | Centering & shuttering with plywood or steel Plate including strutting, propping bracing both ways with steel props and removal of formwork for upto floor Three level for : Walls (any thickness) including attached pilasters, buttresses plinth and string course. | 480 | Sqm | |
10 | 10 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix | 126.49 | Cum | |
11 | 11 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor Three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix | 46.58 | Cum | |
12 | 12 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor Three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix\n | 54.84 | Cum | |
13 | 13 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor Three level. Hot rolled deformed bars (IS : 1139). | 17890.6 | Kg. | |
14 | 14 | Random rubble dry stone Kharanja under floor. | 179.06 | Cum | |
15 | 15 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joints etc. complete fine finish : 12 mm thick | 1406.25 | Sqm | |
16 | 16 | 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) | 438.75 | Sqm | |
17 | 17 | Ornamental cement plaster in cement sand mortar 1 : 4 making Kangooras etc. as per Jaipur Practice. | 100 | Sqm | |
18 | 18 | Polished Blue Kota stone flooring skirting, laid over 20 mm thick base of C.M. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete : 25 mm thick slab. | 337.5 | Sqm | |
19 | 19 | Polished Blue Kota Stone slab in steps, walls, pillars having fine machine cut edges laid on 12 mm (Av.) thick cement mortar 1 : 3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete : 25 mm thick slab area 901 to 2000 Sq.Cm. | 56.25 | Sqm | |
20 | 20 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. | 325 | Cum | |
21 | 21 | Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work / Kota Stone Full Edge moulding | 100 | Rmt. | |
22 | 22 | Providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. | 1250 | Kg | |
23 | 23 | Lime concrete terracing on roofs average thickness 100 mm laid to slope with 25 mm nominal size brick aggregate and 50% lime mortar 1 : 2 (1-lime putty : 2-surkhi/sand) rammed and finished with Gur and Belgira treatment including rounding of junction with parapet wall complete. | 438.75 | Sqm | |
24 | 24 | Providing gola (batta) in lime concrete using 50% lime surkhi / sand mortar 1 : 2 with grit along joint of walls and terrace finished with lime mortar 1 : 2 plaster with Gur, Gugal, Methi etc. in concave shape of size : 100 mm x 100 mm | 420 | RM | |
25 | 25 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete | 1125 | Sqm | |
26 | 26 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. | 1125 | Sqm | |
27 | 27 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect. New Work | 1000 | Sqm | |
28 | 28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | 530 | Sqm | |
29 | 29 | Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment). | 375 | Sqm | |
30 | 30 | Providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with : Stone slab 40 to 50 mm thick average. | 200 | Sqm | |
31 | 31 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia | 175 | Rmt | |
32 | 32 | Printing New Letter and Figures of any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade Hindi ( Matras commas and the like not to be measured and paid for Half letter shall be counted as half ) | 1000 | per cm height per letter | |
33 | 33 | Transportation of excavated earth from site including loading – unloading etc. complete with all lead and lift.(For 5 Km lead) | 983.8 | Cum | |
34 | 34 | Demolishing brick work manually/ by mechanical means including stacking of serviceable MATERIAL and disposal of unserviceable MATERIAL within 50 metres lead as per direction of Engineer-in-charge. : In cement mortar. | 100 | Cum | |
35 | 35 | Demolishing cement concrete manually/ by mechanical means including disposal of MATERIAL within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix. | 50 | Cum | |
36 | 36 | S & FCC 1:2:4 (M15) Precast kerb on dand upto 60 cm length over 20 mm thick base of cement mortar 1:6 including jointing, earthwork, painting and jointing with cement mortar 1:4 of size. | 200 | Rmt | |
37 | 37 | Provinding and laying of paver block as per IS 15658 : 2006 (Indian standerd for Precast concrete block for Paving -specification) and IRC :SP:63-2004(guidelines for the use of interlocking concrete blockPavement) (from BIS approved manufactrers M-40,80mm thick to be used in medium-traffic (Medium trafficis defind as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight , or an equivalent of 0.5 to 2.0 MSA for a design life of 20years) like city streets, small and medium market roads, low volume roads ,ytility cuts on arterial roads, etc.Category 'B' denated only two side like I,Z,T shape etc. as per IRC SP 63:2004 | 160 | Sqm | |
38 | 38 | Wiring of twin control light /fan / call bell point with 1.5 sq. mm nominal size FR PVC insulated unshethed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size FR PVC insulated unslated unsheathed flexible copper earth conductor 1.1 kv grade (IS:694) of approved make in surface / recessed ISI marked MMS (IS:9537 P - III) PVC conduit & it's accessories, round tles, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point, 6 A two way switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. Short point (up to 3 mtr.) | |||
39 | 38.1 | (A) Short Point (up to 3mtr) | 25 | Each | |
40 | 38.2 | (B) Medium Point (up to 6mtr) | 25 | Each | |
41 | 38.3 | ( C ) Long Point (up to 10mtr) | 25 | Each | |
42 | 39 | Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kg grade (IS:694) of approved make in surface/ recessed ISI marked medium duty PVC conduit & it's accessories, Hot Dipped Galvanized M.S Modular box with earth terminal, screwless cage connectors for neutral looping in switch board , 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required. On board | 25 | P Point | |
43 | 40 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. | |||
44 | 40.1 | 2 x 2.5 sq. mm + 1x1.5 sqmm | 150 | Mtr. | |
45 | 40.2 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. | 150 | Mtr. | |
46 | 41 | Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175 x 100 x 60 mm. no surface or in recessed with suitable size phenolic laminated sheet cover inlcuidng cost of 6 pin 16 amp. Switch and socket outet, making connection, testing, etc. as required. | 25 | Each | |
47 | 42 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828(1996)/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required. single pole mcb | |||
48 | 42.1 | 6A to 32A rating | 25 | Each | |
49 | 43 | P&F 240/415 v isolator conforming to IS:13947-III/IEC 60947-3 on existing board / sheet including making connections with lugs testing etc. as required. Triple pole isolator 30 A / 40 A rating63 A rating | 5 | Each | |
50 | 44 | P&F Recessed/Surface mounting heavy duty horizontal type sheet Distribution board phophatised/powder painted complete with suitale rating insulated copper bus bar, shorting link, neutral link, earth link and din bar, masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs, testing etc. as requried. Single door (single phase) 12 Way | 3 | Each | |
51 | 45 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 kv grade with aluminium conductor of IS:1554 P-I / IS:7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx 75cm size trench, 25 cm thick under under laying of sand, IInd class bricks covering, refiling earth, compaction of earth, making necessary connection, testing etc. as required of size. | |||
52 | 45.1 | 4.0 Sq. mm 4 core | 40 | Mtr. | |
53 | 46 | Plate Earting as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 class waterin pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Frame of size 300 mm x 300 mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. | 3 | Set | |
54 | 47 | P & F 18 swg M.S. Recessed fan box, hexagonal/round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side. | 25 | Each | |
55 | 48 | P & F following sizes (dia) of ISI marked medium duty PVC coduit along with accessories in surface/ recessed using sadles, clamps, fastener, as required including cutting the wall and making good the same as required. Group II, 25 mm dia | 400 | Rmt | |
56 | 49 | P & F double ball bearing capacitor start, aluminium body & blade ceiling fan with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 1200 mm sweep | 25 | Each | |
57 | 50 | P & F industrial fluorescent tube fitting with reflector fabricated from CRCA sheet and finished with powder coating / vitreous enamelled complete with accessories (Low Loss Copper Choke, starter, starter seat) / Electronic Choke with terminal block duly prewired with copper conductor including making connection, testing etc. as required.( without tube) With vitreous enamelled reflector 1 X 36 Watts with OCCB | 25 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail