Providing Lwss To Pc Habitations In Gp Bhargaon Kotli Dhanyara Uperli Surari Khalanoo Tehsil Sadar Distt Mandi Hp Providing Lwss Under Gp Nagdhar Navlay Deori Gharan Shiva Maihani Phase Ist Phase 2Nd Tehsil Sadar Distt Mandi Drilling Lowering Of Bore Wel, Mandi-Himachal Pradesh

Irrigation And Public Health Department has published Providing Lwss To Pc Habitations In Gp Bhargaon Kotli Dhanyara Uperli Surari Khalanoo Tehsil Sadar Distt Mandi Hp Providing Lwss Under Gp Nagdhar Navlay Deori Gharan Shiva Maihani Phase Ist Phase 2Nd Tehsil Sadar Distt Mandi Drilling Lowering Of Bore Wel. Submission Date for this Tender is 28-06-2021. Manhole Construction Tenders in Mandi Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28184865
Providing Lwss To Pc Habitations In Gp Bhargaon Kotli Dhanyara Uperli Surari Khalanoo Tehsil Sadar Distt Mandi Hp Providing Lwss Under Gp Nagdhar Navlay Deori Gharan Shiva Maihani Phase Ist Phase 2Nd Tehsil Sadar Distt Mandi Drilling Lowering Of Bore Wel
Open Tender
Indian
Himachal Pradesh
Mandi
28-06-2021

Tender Details

Providing Lwss To Pc Habitations In Gp Bhargaon Kotli Dhanyara Uperli Surari Khalanoo Tehsil Sadar Distt Mandi Hp Providing Lwss Under Gp Nagdhar Navlay Deori Gharan Shiva Maihani Phase Ist Phase 2Nd Tehsil Sadar Distt Mandi Drilling Lowering Of Bore Well 50 M Deep C/O Rail Cum Trolly System With Winch Room C/O Source Intake Chambers C/O 0 . 72 Mld Water Treatment Plants C/O Sedimentation Tanks Slow Sand Filter Beds C/O Pump Houses Providing Laying Jointing And Testing

Key Value

Document Fees
INR 2500 /-
EMD
INR 1735500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:- Providing LWSS to PC Habitations in G.P. Bhargaon, Kotli, Dhanyara, Uperli Surari & Khalanoo Tehsil Sadar Distt. Mandi (H.P.), Providing LWSS under G.P. Nagdhar, Navlay, Deori, Gharan, Shiva & Maihani Phase Ist & Phase 2nd Tehsil Sadar Distt. Mandi (HP), Providing FHTC to the Balance Households of various villages in GP Kotadhar, Pali, Farsh, Kathyari, Bandhi, Kot Dhalyas, Bhatwari, Aut, Nau and Kigas Tehsil Aut Distt. Mandi (HP), Providing FHTC to the Balance Households of LWSS Kathwari and LWSS Dhanyari and its adjoining villages in GP Bir, Kasan, Sadoh, Tarnoh, Bari Gumanu & Sadyana Tehsil Sadar Distt. Mandi (HP), Providing FHTC to the Balance Households in GP Baggi Tungal, Sai, Nichla lot, Kasan, Kot, Kotli and sehli Tehsil Sadar Distt. Mandi (HP), Providing FHTC to the Balance Households of various villages of GP Bizan, Tung and Nasloh Tehsil Sadar Distt Mandi (HP), Providing FHTC to the Balance Households of various villages in GP Dudar Bharoun, Majhwar, Dhar, Pandoh, Seyogi and Jagar Tehsil Sadar Distt Mandi (HP) and Providing LWSS to PC Habitation in Census Village DPF Sarain, Kanoj & Ropain GP Chaihtigarh Tehsil Aut Distt Mandi (HP) (Under JJM)(SH:- Drilling & Lowering of Bore Well 50 M Deep, C/O Rail cum Trolly System with Winch Room, C/O Source Intake Chambers, C/O 0.72 MLD Water Treatment Plants, C/O Sedimentation Tanks, Slow sand Filter Beds, C/O Pump Houses, Providing, Laying, Jointing and Testing of Rising Mains, Gravity Mains and Distribution System, S/E of Pumping Machinery, C/O RCC Circular Ground Water Storage Tanks, C/O WC & Toilet attach with Pump Houses, Wiring to Pump Houses and Thrust Anchor Blocks)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 (A) Providing LWSS to PC Habitations in G.P. Bhargaon, Kotli, Dhanyara, Uperli Surari & Khalanoo Tehsil Sadar Distt. Mandi (H.P.)Excavation in foundations trenches etc. ( for pipes and pits ) upto all depths in all kinds of soil such as pick work, jumper work, blasting and chiselling soft/hard rocks where blasting is prohibited in all leads and lifts including trimming and dressing of sides levelling of bed to correct excavation and returning the stacked soil after laying jointing and testing of G.I.Pipes in trenches in 15 cm. layers including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting/timbering and dewatering where ever required including restoration of un-metalled/metalled paved surface of its original conditions including cost of diversion for traffic night signals Fixing caution boards and fencing etc.complete in all respects. BI01010001010000000000000515BI0100001113 1884.96 Cum
2 2 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 crushed stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads & lifts. BI01010001010000000000000515BI0100001114 2.29 Cum
3 3 Providing and laying cement concrete 1:4:8 (1 cement : 4 sand : 8 crushed stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all leads and lifts. BI01010001010000000000000515BI0100001115 7.88 Cum
4 4 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 crushed stone aggreagte 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all leads and lifts. BI01010001010000000000000515BI0100001116 67.25 Cum
5 5 Providing and laying cement concrete 1:6:12 (1 cement : 6 sand : 12 crushed stone aggreagte 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all leads and lifts. BI01010001010000000000000515BI0100001117 3.17 Cum
6 6 Random rubble masonry /polygonal rubble masonry (uncoursed brought to courses ) with hard stone of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 (1cement:6 sand:12 crushed stone aggregate 20 mm nominal size) at plinth level in cement mortar 1:6 (1 cement : 6 sand) in all leads and lifts. BI01010001010000000000000515BI0100001118 14.15 Cum
7 7 Providing and Fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jump lock jamb,beed and if required angle threshold of mild steel angle of section 50x25mm or base ties of 1.25 mm pressed mild steel welded or rigidly fixed together by mechanical means,adjustable lugs with split and tails to each jamb including steel butt things 2.5 mm thick with guards lock strike plate and shock as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001119 26.85 Rmt
8 8 Brick work using common burnt clay building bricks in foundation and plinth in cement mortar 1:6 (1cement : 6 sand ) in all leads and lifts. 2nd class bricks. BI01010001010000000000000515BI0100001120 7.29 Cum
9 9 Providing form work with steel plates 3.15 mm thick welded with angle iron in frames 30x30x5 mm, so as to give a fair finish including centering ,shuttering, propping etc.with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in:-Vertical surface such as walls(any thickness) partitions and the like including attached pillasters, butteresses, plinth and string courses and the like in all leads & lifts. BI01010001010000000000000515BI0100001121 2.91 Sqm
10 9.01 Flat surfaces such as soffits of suspended floors, roofs landings and the like: floors etc. up to 200 mm in thickness in all leads & lifts. BI01010001010000000000000515BI0100001122 26.12 Sqm
11 9.02 Edges of slab and breaks in floors and walls under 20 cm wide in all leads and lifts. BI01010001010000000000000515BI0100001123 15.84 Rmt
12 10 Providing and laying cement concrete 1:2:4 ( 1 cement : 2 sand : 4 crushed stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Foundation footings bases of columns and the like and mass concrete in all leads and lifts. BI01010001010000000000000515BI0100001124 7.5 Cum
13 10.01 Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001125 3.48 Cum
14 11 Providing and laying Tor Steel reinforcement for reinforcement cement concrete work including bending, binding and placing in position includig the cost of binding wire and cutting in all leads and lifts as per the directions of the Enginerer-in-Charge. BI01010001010000000000000515BI0100001126 650.7 Kg
15 12 Providing and Fixing of Carb winch room of 3 MT capacity with lift of 20 meters with 16 mm wide rope in all leads and lifts. BI01010001010000000000000515BI0100001127 1 No.
16 13 Providing and Fixing of Carb winch of 10 MT capacity with lift of 20 meters with 25 mm wire rope in all leads and lifts. BI01010001010000000000000515BI0100001128 1 No.
17 14 Providing and Fixing of moveable trolly of 10 MT capacity to mount the pumping machinery etc.and attached to the winch on rail track of 750 mm complete in all leads and lifts. BI01010001010000000000000515BI0100001129 1 No.
18 15 Providing and Fixing of moveable trolly of 10 MT capacity of carriage of matirial etc.and attached to the winch room on rail track of 750 mm complete in all leads and lifts. BI01010001010000000000000515BI0100001130 1 No.
19 16 Providing and Fixing of flat footed rail type 50 R for N.G.track i/c rail fixtures and fastners etc. complete in all leads and lifts. BI01010001010000000000000515BI0100001131 2332 Kg
20 17 Providing and Fixing 300X300X10mm insert plate @ 90 cm C/C complete in all leads and lifts. BI01010001010000000000000515BI0100001132 706 Kg
21 18 Providing and Fixing Lugs 10mm dia 20 cm long complete in all leads and lifts. BI01010001010000000000000515BI0100001133 49.6 Kg
22 19 Boulder filling under floor complete in all leads and lifts. BI01010001010000000000000515BI0100001134 2.14 Cum
23 20 6 mm cement plaster to ceiling in cement mortor 1:3 (1 cement : 3 Sand) complete in all leads and lifts. BI01010001010000000000000515BI0100001135 28.73 Sqm
24 21 15mm thick cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering upto floor two level brick/concrete/stone walls for interior plastering upto floor two levels including arrises internal rounded angles chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smoothing cement mortar 1:6 (1cement:6 sand) in all leads and lifts. BI01010001010000000000000515BI0100001136 78.97 Sqm
25 22 15mm thick cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering upto floor two level brick/concrete/stone walls for interior plastering upto floor two levels including arrises internal rounded angles chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smoothing cement mortar 1:3 (1cement:3 sand) in all leads and lifts. BI01010001010000000000000515BI0100001137 26.5 Sqm
26 23 Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 crushed stone aggregate 20 mm nominal size) laid in one layer finished with a floating coat of neat cement 40 mm thick in all leads and lifts. BI01010001010000000000000515BI0100001138 12.18 Sqm
27 24 Providing and Fixing panneled glazed or panelled and glazed shutters for doors, windows and clerestory windows,including black enamelled iron butt hinges with necessary screws. 40 mm thick. 2nd class deodar wood in all leads and lifts. BI01010001010000000000000515BI0100001139 7.38 Sqm
28 25 Providing and Fixing anodized MS sliding door bolts with bolts and nuts screws etc.complete. 300 x 16 mm in all leads and lifts. BI01010001010000000000000515BI0100001140 1 No.
29 26 Providing and Fixing anodized MS tower bolts(barrel type)with screws etc.complete in all leads and lifts.250X10 mm BI01010001010000000000000515BI0100001141 2 Nos.
30 26.01 150X10 mm BI01010001010000000000000515BI0100001142 18 Nos.
31 27 Providing and Fixing anodized MS Handles with necessary screws etc.complete 125 mm in all leads and lifts.. BI01010001010000000000000515BI0100001143 11 Nos.
32 28 White washing with lime on undecorated wall surfaces two coats to give an even shade including thoroughly brooming the surface to remove all dirt,dust and other foreign matters in all leads and lifts. BI01010001010000000000000515BI0100001144 28.73 Sqm
33 29 Distempering with dry distemper of approved brand and manufacture (two coats)and of required shade on un-decorated wall surface to give an even shade sand papered smooth in all leads and lifts. BI01010001010000000000000515BI0100001145 78.97 Sqm
34 30 Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,grease,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink in all leads and lifts. BI01010001010000000000000515BI0100001146 12.96 Sqm
35 31 Painting two coats (excluding priming coat)on new wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of dirt,dust and other foreign matters sand papering and stopping with enamel paint other than white in all leads and lifts. BI01010001010000000000000515BI0100001147 12.96 Sqm
36 32 Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1cement : 3 sand : 6 crushed stone aggregate 20 mm nominal size) in all leads and lifts. BI01010001010000000000000515BI0100001148 6.32 Sqm
37 33 Providing under layer for plinth protection of 75mm thick (unconsolidated) bed dry brick/stone agg.40mm nominal size well rammed with rammed and consolidated and grouted with fine sand including preparation of ground in all leads and lifts. BI01010001010000000000000515BI0100001149 8.42 Sqm
38 34 Providing and Fixing of MS Fabricated Protection Panel 750 mm x 750 mm made with MS Angle 40 x 40 x 4 mm for frame, MS Angle 30 x 30 x 3 mm for cover, MS Flat 25 x 5 mm for Fixing of sliding door bolt and MS Sheet 4.00 mm thick for protection of manhole covers of storage tanks including the cost of cutting and welding of MS angle, MS Flat & MS Sheet, embedding in RCC Slab by drilling holes in MS angle & in RCC slab, provision for providing and Fixing sliding door bolt 300 x 16 mm, MS Handle 100 mm, Lock and applying a coat of red lead paint & painting two coat with steel paint (Firoza Blue) complete job in all respect in all leads and lifts and to the entire satisfaction of the Engineer - in - Charge. BI01010001010000000000000515BI0100001150 1 No.
39 35 Providing and placing in horizontal layers filtering media duly graded,screened,washed and cleaned as specified by the Engineer in charge in all leads and lifts.Top Layer :-FineSand Screened, washed, cleaned & graded from 2.00 mm to 3.00 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001151 1.35 Cum
40 35.01 2nd Layer :-Coursed sand screened, cleaned, washed & graded 3 mm to 6 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001152 0.18 Cum
41 35.02 3rd Layer :-Bajri screaned, washed and graded 6 mm to 20 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001153 0.18 Cum
42 35.03 4th Layer :-Bajri screaned, washed & graded 20 mm to 25 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001154 0.18 Cum
43 35.04 5th Layer :- Brocken stone screaned, washed and graded for 50 mm to 75 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001155 0.27 Cum
44 36 Construction designing testing and commissioning of water treatment plant 0.72 MLD at following locations comprising of following units.RAW WATER TANK .INLET CHAMBER .INLET CHAMBER &PARSHALL FLUME.PRE SETTLING TANK.FLASH MIXER UNIT. FLOCULATOR SETTLING TANK. RAPID SAND GRAVITY FILTER . BACK WASH SYSTEM . CLEAR WATER TANK . PLANT BULDING . LABORATORY EQUIPMENT and Proivision for barbed wire fencing with RCC poles around water treatment plant (Area 2x70.00+27.00)=194.00 Rmt.complete in all respect.and to the entire satisfaction of the Engineer-in-Charge. Note:-\n(1). The Lump-Sum Price bid of the contractor shall consist of following three parts.\n(a). Cost of WTP component including pump house cum WC toilet with septic tanks mechanical/electrical works (excluding site development) Rs.\n(b). Cost of site development work including R/wall, B/wall etc Rs.\n(c ). C/O Cost of fencing work RsThe design/ drawing of mechanical/ electrical equipment and wiring etc. along with manufacture’s specification/design also be submitted for approval of the department after vetting. In design and drawings the contractor/ firm shall submit the design calculations clearly indicating various formulae used and reference of books IS codes thereto. The contractors/ firms shall also supply software copy.(CD) of design calculation along with basic data used in the design so as to facilitate the quick checking/approval of the same. On the completion of all civil mechanical and electrical works, the contractor shall test/run the plant for 90 days before handing over the same to the department at the risk and cost of the contractor, however, electrical charges shall be borne by the department.\n(d). Cost of Gaseous Chlorination.\n(e) C/O Approach roadh for WTP.\n( f). Total Cost = ( a+b+c+d+e). Rs. \n(2). The detailed design parameters /specification and conditions shall be as per detailed design parameters.\n(3). The contractor/ firm shall propose the layout of WTP units in such a manner that the cost of site development is minimum. \nTerms and Condition:- \nThe firm shall submit the detailed hydraulic and structural design and drawing for each component of treatment plant which shall be approved by the department before the work is started. Before submitting the hydraulic as well as structural design and drawing for approval by the department it should be duly vetted from any of institution mentioned below:-\n(ii) Any of IIT/NIT\n(iii) (ii) Punjab Engineering College Chandigarh. During this period the contractor shall run the plant of full rated capacity and produce the results as per the CPHEEO standards and ISI codes in the presence of Engineer-in-Charge or his representative. During this period , the daily testing of raw water and treated water samples shall be done. Complete record of the test results and the flow measurement shall be kept during this period. If the performance of various units of the treatment plant is as specified in the CPHEEO Manual the plant shall be formally taken over by the department, otherwise the contactor shall make necessary changes / repair to improve the efficiency of the units/plant. The contractor / firm shall run and maintain the plant for further 90 days after handing over the plant to the department. During this period the firm shall depute at least one trained person to train the departmental persons in operating, maintaining the plant and regular testing of the raw water and treated water samples in the laboratory for the same period shall be done. During this period. Only energy charges shall be borne by the department. The contractor/ firm shall be responsible for any break down of the machinery/ equipment and shall have to repair all the fault/defects as directed by the Engineer-in-Charge. Out of 90 days one month should preferably be Monsoon to test the plant for heavy silt loads. \n BI01010001010000000000000515BI0100001156 1 Job
45 37 Supply, installation, commissioning and testing of vaccum oprated, pressure feed gaseous clorinator of Toshcon jesco / Capital make for clorination of water by direct feeding to existing water main consisting of the following components in all leads and lifts as spacified below. Providing installation & commissioning of gaseouos type fully vaccum chlorination system having 0-1.0 kg per hour chlorine gas feeding capacity of PENWALT(USA) / ECOCHLOR (USA) / ENCHLOR (USA)/Jasco (USA) make. The system shall have vacuum regulator with inbuilt Filter and Pressure Gauge, in-built Measuring Glass with dose rate adjuster, Vacuum ejector, ejector Non Return Valve, 4.0 m long PE tubing (As Vacuum and Vent tubing), 32 mm Spanner, Ammonia Solution etc. in all leads and lifts and to the entire satisfaction of Engineer-in-charge . BI01010001010000000000000515BI0100001157 1 Job
46 37.01 Chlorine Gas Injector. BI01010001010000000000000515BI0100001158 2 Job
47 37.02 Providing installation & commissioning single phase monoblock pump 1.5 to 2.0 HP of required discharge capacity with Motor of Kirloskar/Crompton Greaves make with common steel fabricated base frame duly grouted at site including starter and cabling including all leads and lifts and as per entire satisfaction of Engineer - in - charge. BI01010001010000000000000515BI0100001159 2 Job
48 37.03 Providing installation & commissioning of ISI marked PVC pipe & fittings, ball valves, Lead washers, O-Rings, G.I. pipe and fitting for installation and grouting of steel stand for ejector of gaseous type chlorination system complete in all respect including all leads and lifts and as per entire satisfaction of Engineer - in - charge. \n BI01010001010000000000000515BI0100001160 1 Job
49 37.04 Providing & Installation of gas filled chlorine gas cylinder of 100 kg capacity as per BIS standard duly certified by the petroleum and explosive safety organization Govt. of India for filling of chlorine gas required for the scheme including all leads and lifts and as per entire satisfaction of Engineer-in-charge . BI01010001010000000000000515BI0100001161 4 Cylinder
50 37.05 Providing and Supplying of Safety kit. BI01010001010000000000000515BI0100001162 1 Set
51 38 Providing, laying, jointiong and testing in trenches GMS pipe of following dia meters confirming to BIS: 1239 (Part-i),of following grade having wall thickness as specified below with plain end and capable of with standing required test pressure in random length of 4 to 7 meters, including special, short pieces , beds reducers, tees etc. made from parent tube providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392 - 1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3 mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing , providing and fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge . The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipe shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carrage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts (Earth work in trenches will be measured and paid for separately)Raw Water Stage100 mm dia-GMS pipe 4.50 mm thickness with Flange Table-17 (Medium Class) BI01010001010000000000000515BI0100001163 11 Rmt.
52 39 Providing, laying, jointiong and testing (by way of circumfrential butt welded joints by electrical arc welding) and testing of GMS pipe of following dia meters confirming to BIS: 1239 (Part-i) grade specified below (latest withup to date amendments ) having wall thickness as specified below with bevelled ends and capable of with standing required test pressure in random length of 4 to 7 meters, including manufacturing reducers tapers , all short pieces, beds etc. as per site requirement made from parent tubes. The laying of pipe will include all operation such as cutting, welding , jointing , fabrication of bends , tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge . The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipe shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carrage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts (Earth work in trenches will be measured and paid for separately)Raw Water Stage100 mm dia-GMS pipe 4.50 mm thickness (Medium Class) BI01010001010000000000000515BI0100001164 209 Rmt.
53 40 Pumping Machinery:- Supply of submersible pumping set of KSB/Calama/SU/ johnson and other approved make comprising to latest relevant BIS Code. The pump should be fitted with bronze impller of suitable alloys as per BIS 5659-1972 latest suitable for having greased packed bearing and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersibed squirrei cage electric induction motor (water proof type) of required HP RPM 2900 of Kirloskar /NGEF/ Cromption and other approved make make conformining to BIS 9287-1979 latest with upto date amendmednts totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. It should also be fitted with a device to take up expansion of water with heating of motor:-Discharge(Q) - 7.00 LPS for each pump,Total Dynamic heads:- 66.82 Meter, LWL in sump well(h) 693.00 Meter,Shaft Level - 690.60 Meter,Level at Discharge point750.00 Meter, Suction Lift '+ve , Discharge Head - 57.00 Meter, Static head - 57.00 Meter, Rising Main---Rising Main -220 Meter,Dia - 100 mm,Pumping Hours - 16 Hours,Altitude of installation above MSL -700 Meter Characterstics of water - Clear Water with turbidity up to 50 PPM,Temperature - 25 degree centigrade BI01010001010000000000000515BI0100001165 2 Sets
54 40.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001166 1 Set
55 40.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001167 1 No.
56 40.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001168 1 No.
57 40.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001169 1 No.
58 40.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001170 1 No.
59 40.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001171 1 No.
60 40.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001172 1 No.
61 40.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001173 1 No.
62 40.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001174 1 set
63 40.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001175 2 set
64 40.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001176 2 set
65 40.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001177 2 set
66 40.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001178 2 Nos
67 40.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001179 2 Nos
68 40.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001180 2 Nos
69 40.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001181 2 Nos
70 40.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001182 2 Nos
71 40.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001183 2 Nos
72 40.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001184 2 Nos
73 40.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001185 1 No.
74 40.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001186 1 No.
75 40.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001187 1 No.
76 40.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001188 1 Job
77 40.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:a) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n\n BI01010001010000000000000515BI0100001189 10 Rmt.
78 40.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001190 10 Rmt.
79 40.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001191 5 Rmt.
80 40.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.(a) Motor side (From switch to starter and starter to motor)\n BI01010001010000000000000515BI0100001192 10 Rmt.
81 40.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001193 10 Rmt.
82 40.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001194 1 Job
83 41 Providing & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:Discharge(Q) - 7.00 LPS for each pump , Total Dynamic heads:- 781.81 Meter, LWL in sump well(h) - 737.00 Meter ,. Shaft Level 736.00 Meter Level at Discharge point - 1394.00 Meter ,Suction Lift -'+ve , Discharge Head - 658.00 Meter, Static head- 658.00 Meter,Rising Main-Length -7200 Meter , Dia - 100 mm,Pumping Hours -16 Hours,Altitude of installation above MSL -750 Meter ,Characterstics of water -Clear Water with turbidity up to 50 PPM,Temperature - 25 degree centigrade BI01010001010000000000000515BI0100001195 2 Sets
84 41.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001196 1 Set
85 41.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001197 1 No.
86 41.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001198 1 No.
87 41.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001199 1 No.
88 41.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001200 1 No.
89 41.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001201 1 No.
90 41.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001202 1 No.
91 41.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001203 1 No.
92 41.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001204 1 set
93 41.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001205 2 set
94 41.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001206 2 set
95 41.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001207 2 set
96 41.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001208 2 Nos
97 41.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001209 2 Nos
98 41.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001210 2 Nos
99 41.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001211 2 Nos
100 41.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001212 2 Nos
101 41.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001213 2 Nos
102 41.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001214 2 Nos
103 41.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001215 1 No.
104 41.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001216 1 No.
105 41.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001217 1 No.
106 41.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001218 1 Job
107 41.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:a) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5 M/second in the suction pipe\n\n BI01010001010000000000000515BI0100001219 10 Rmt.
108 41.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001220 10 Rmt.
109 41.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001221 5 Rmt.
110 41.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.(a) Motor side (From switch to starter and starter to motor)\n BI01010001010000000000000515BI0100001222 10 Rmt.
111 41.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001224 10 Rmt.
112 41.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001225 1 Job
113 42 Providing, laying and jointing, testing in trenches galvanised mild steel tubes (Light Class) screwed and socketed, ISI marked, conformining to IS :1239 & latest with upto date ammendments including tube fitting such as bends, tees, air valves, unions and collars etc. as per direction and to the entire satisfaction of the Engineer-in-charge (Earth work in trenches to be measured and paid for separately) in all leads and lifts.65 mm Diameter BI01010001010000000000000515BI0100001226 1300 Rmt
114 42.01 50 mm Diameter BI01010001010000000000000515BI0100001227 450 Rmt
115 42.02 40 mm Diameter BI01010001010000000000000515BI0100001228 950 Rmt
116 42.03 32 mm Diameter BI01010001010000000000000515BI0100001229 2450 Rmt
117 43 Providing and Fixing Brass Stop Cock, Wheel Valve including housing chamber complete in all leads and lifts.80 mm Diameter BI01010001010000000000000515BI0100001230 1 No.
118 43.01 65 mm Diameter BI01010001010000000000000515BI0100001231 2 Nos.
119 43.02 50 mm Diameter BI01010001010000000000000515BI0100001232 2 Nos.
120 43.03 40 mm Diameter BI01010001010000000000000515BI0100001233 1 No.
121 43.04 32 mm Diameter BI01010001010000000000000515BI0100001234 1 No.
122 44 Providing LWSS under G.P. Nagdhar, Navlay, Deori, Gharan, Shiva & Maihani Phase Ist & Phase 2nd Tehsil Sadar Distt. Mandi (HP)Excavation in foundations trenches etc. ( for pipes and pits ) upto all depths in all kinds of soil such as pick work, jumper work, blasting and chiselling soft/hard rocks where blasting is prohibited in all leads and lifts including trimming and dressing of sides levelling of bed to correct excavation and returning the stacked soil after laying jointing and testing of G.I.Pipes in trenches in 15 cm. layers including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting/timbering and dewatering where ever required including restoration of un-metalled/metalled paved surface of its original conditions including cost of diversion for traffic night signals Fixing caution boards and fencing etc.complete in all respects. BI01010001010000000000000515BI0100001235 3633.13 Cum
123 45 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 crushed stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads & lifts. BI01010001010000000000000515BI0100001236 45.93 Cum
124 46 Providing and laying cement concrete 1:4:8 (1 cement : 4 sand : 8 crushed stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all leads and lifts. BI01010001010000000000000515BI0100001237 4.3 Cum
125 47 Providing form work with steel plates 3.15 mm thick welded with angle iron in frames 30x30x5 mm, so as to give a fair finish including centering ,shuttering, propping etc.with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in:-Vertical surface such as walls(any thickness) partitions and the like including attached pillasters, butteresses, plinth and string courses and the like in all leads & lifts. BI01010001010000000000000515BI0100001238 857.39 Sqm
126 47.01 Flat surfaces such as soffits of suspended floors, roofs landings and the like: floors etc. up to 200 mm in thickness in all leads & lifts. BI01010001010000000000000515BI0100001239 37.73 Sqm
127 48 Providing form work of ordinary timber plankings so as to give a rough finish including centering, shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plaiin concrete work in:- Arches, domes, vaults up to all span in all leads and lifts. BI01010001010000000000000515BI0100001240 36.17 Sqm
128 49 Providing and laying cement concrete 1:11/2 :3 ( 1cement : 1 1/2 sand: 3 crushed stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Foundation footings bases of columns and the like and mass concrete in all leads and lifts. BI01010001010000000000000515BI0100001241 36.03 Cum
129 49.01 Walls (any thickness but not less than 0.1 mtr thickness) attached pilasters, buttresses, plinth and string courses etc. from top of foundation level up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001242 62.47 Cum
130 50 Providing and laying cement concrete 1:2:4 ( 1 cement : 2 sand : 4 crushed stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Foundation footings bases of columns and the like and mass concrete in all leads and lifts. BI01010001010000000000000515BI0100001243 21.85 Cum
131 50.01 Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001244 5.29 Cum
132 50.02 Dome roofs, landings shelves and their supports balconies, beams, girders, bressumers and cantilevers etc. any shape in all leads & lifts. BI01010001010000000000000515BI0100001245 3.47 Cum
133 51 Providing and laying Tor Steel reinforcement for reinforcement cement concrete work including bending, binding and placing in position includig the cost of binding wire and cutting in all leads and lifts as per the directions of the Enginerer-in-Charge. BI01010001010000000000000515BI0100001246 10557.5 Kg
134 52 Providing and Fixing of Steel/fibre reinforcement concrete (SFRC) manhole cover with frame conforming to IS-12592 (Part - I)-1998 with latest ammendments 560 mm dia medium duty in all leads and lifts. BI01010001010000000000000515BI0100001247 6 Nos.
135 53 Providing and Fixing cast iron rungs 200 mm wide with chequered of ribbed non slip surface including Fixing in manhole with 200x200x100 mm cement concrete 1:3:6 (1 cement:3 sand:6 graded stone aggregate 20mm nominal size) in all leads and lifts. BI01010001010000000000000515BI0100001248 10 Nos.
136 54 Providing and Fixing of G.I. pipe dia mentioned below for inlet, outlet and scour pipe etc in all leads and lifts.80 mm diameter BI01010001010000000000000515BI0100001249 60 Rmt
137 55 Providing and Fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including Fixing with approved adhesive etc. complete in all leads and lifts.110 mm nominal bore. BI01010001010000000000000515BI0100001250 2 Rmt
138 56 Providing and Fixing Cast Iron Sluice Valve of BIR make BIS No. 14846 with flange Table - 5 including welding of flanges, Nuts & Bolts and Gasket etc.The sluice valve conforming to IS - 780. The dia of valve as mentioned below complete in all leads and lifts and to the entire satisfaction of the Engineer - in - Charge. 80 MM Diameter Table - 5 BI01010001010000000000000515BI0100001251 10 Nos.
139 57 Providing and Fixing Aquamet / Itron / ABB Multi jet Class B, EMR Compatible water, Inferential type, Dry Dial Water Meter with end connectors in brass as per ISS 779:1994 and conforming to ISO - 4064 class B having ready made holes, rubber gasket with saddle and supports and union including freight charges, connection charges complete in all respect and to the entire satisfaction of the Engineer - in - Charge.100 mm dia. BI01010001010000000000000515BI0100001252 1 No.
140 58 Providing and Fixing of MS Fabricated Protection Panel 750 mm x 750 mm made with MS Angle 40 x 40 x 4 mm for frame, MS Angle 30 x 30 x 3 mm for cover, MS Flat 25 x 5 mm for Fixing of sliding door bolt and MS Sheet 4.00 mm thick for protection of manhole covers of storage tanks including the cost of cutting and welding of MS angle, MS Flat & MS Sheet, embedding in RCC Slab by drilling holes in MS angle & in RCC slab, provision for providing and Fixing sliding door bolt 300 x 16 mm, MS Handle 100 mm, Lock and applying a coat of red lead paint & painting two coat with steel paint (Firoza Blue) complete job in all respect in all leads and lifts and to the entire satisfaction of the Engineer - in - Charge. BI01010001010000000000000515BI0100001253 3 Nos.
141 59 1.20 metre heigh fencing (as per approved design) 1.80 metres R.C.C.posts 3 metres centre to centre and R.C.C. struts with 7 horizental lines and two diagonals of galvanised steel bar bed wire (IS 278-1962 type I) weighing 9.38 kg./100 metres (minimum) strained and fixed to posts by typing to 6mm galvanised steel bar niles/clips with G.I. binding wire including cost of Excavation, R.C.C. Posts,R.C.C. struts and straining belts and embeded in cement concrete 1:4:8 ( 1cement : 4 sand : 8 graded stone aggregate 40 mm nominal size) and curing complete in all respect with manufacturing & Fixing of MS Gate 1.20X1.50 Meter and to the entire satisfaction of the Engineer-in-Charge. BI01010001010000000000000515BI0100001254 175.15 Rmt
142 60 Providing and placing in horizontal layers filtering media duly graded,screened,washed and cleaned as specified by the Engineer in charge in all leads and lifts.Top Layer :-FineSand Screened, washed, cleaned & graded from 2.00 mm to 3.00 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001255 61.49 Cum
143 60.01 2nd Layer :-Coursed sand screened, cleaned, washed & graded 3 mm to 6 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001256 8.2 Cum
144 60.02 3rd Layer :-Bajri screaned, washed and graded 6 mm to 20 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001257 8.2 Cum
145 60.03 4th Layer :-Bajri screaned, washed & graded 20 mm to 25 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001258 8.2 Cum
146 60.04 5th Layer :- Brocken stone screaned, washed and graded for 50 mm to 75 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001259 12.3 Cum
147 61 Providing and placing Ist class standard bricks in filter bed in two layers so as to make cross drains as per direction of Engineer-in-charge in all leads and lifts. BI01010001010000000000000515BI0100001260 3474 Nos.
148 62 Dismentling & Jointing of MS Flanged Pipes of following diameters from trenches and stacking the same site of work in all lead & lifts. (Earth work to be measured and paid for separately) Ist Stage Shiva Hatuan 80 mm diameter MS Pipe (Grade X-42) 4.00 mm thickness with Flange Table-34 BI01010001010000000000000515BI0100001261 300 Rmt
149 63 Providing , laying, fixing, jointing and testing in trenches MS pipe of following dia meters confirming to confirming to BIS 3183-2007, of following grade and having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).First Stage :- Shiva Hataun 80 mm diameter MS Pipe (Grade X-42) 4.00 mm thickness with Flange Table-34 BI01010001010000000000000515BI0100001262 15 Rmt
150 64 Providing , laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of MS pipe of following dia meters confirming to BIS 3183-2007, steel grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).First Stage :- 80 mm diameter MS Pipe (Grade X-42) 4.00 mm thickness BI01010001010000000000000515BI0100001263 285 Rmt
151 65 Providing, laying, jointiong and testing in trenches GMS pipe of following dia meters confirming to BIS: 1239 (Part-i),of following grade having wall thickness as specified below with plain end and capable of with standing required test pressure in random length of 4 to 7 meters, including special, short pieces , beds reducers, tees etc. made from parent tube providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392 - 1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3 mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing , providing and fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge . The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipe shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carrage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts (Earth work in trenches will be measured and paid for separately)First Stage :- Shiva Hataun 80 mm dia-GMS pipe 4.00 mm thickness with Flange Table-17 (Medium Class) BI01010001010000000000000515BI0100001264 16 Rmt.
152 65.01 80 mm dia-GMS pipe 4.00 mm thickness with Flange Table-5 (Medium Class) BI01010001010000000000000515BI0100001265 5 Rmt.
153 66 Providing, laying, jointiong and testing (by way of circumfrential butt welded joints by electrical arc welding) and testing of GMS pipe of following dia meters confirming to BIS: 1239 (Part-i) grade specified below (latest withup to date amendments ) having wall thickness as specified below with bevelled ends and capable of with standing required test pressure in random length of 4 to 7 meters, including manufacturing reducers tapers , all short pieces, beds etc. as per site requirement made from parent tubes. The laying of pipe will include all operation such as cutting, welding , jointing , fabrication of bends , tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge . The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipe shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carrage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts (Earth work in trenches will be measured and paid for separately)First Stage :-80 mm dia-GMS pipe 4.00 mm thickness (Medium Class) BI01010001010000000000000515BI0100001266 399 Rmt.
154 67 First Stage (Shiva Hataun Phase) :- Providing & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements: Discharge(Q) - 3.29 LPS for each pump,Total Dynamic heads:- 522.41 Mete,rLWL in sump well(h) - 1019.00 Meter, Shaft Level -1022.60 Meter,Level at Discharge point - 1522.00 Meter, Suction Lift '-ve ,Discharge Head - 499.40 Meter,Static head -0,Rising Main-Length -1300 Meter,Dia - 80 ,mm,Pumping Hours - 16 Hours,Altitude of installation above MSL -1000 Meter ,Characterstics of water -Clear Water with turbidity up to 50 PPM,Temperature - 25 degree centigrade BI01010001010000000000000515BI0100001267 2 Sets
155 67.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001268 1 Set
156 67.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001269 1 No.
157 67.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001270 1 No.
158 67.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001271 1 No.
159 67.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001272 1 No.
160 67.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001273 1 No.
161 67.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001274 1 No.
162 67.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001275 1 No.
163 67.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001276 1 set
164 67.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001277 2 set
165 67.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001278 2 set
166 67.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001279 2 set
167 67.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001280 2 Nos
168 67.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001281 2 Nos
169 67.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001282 2 Nos
170 67.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001283 2 Nos
171 67.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001284 2 Nos
172 67.18 Providing double flanged cast steel sluice valve, ASA-600 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001285 2 Nos
173 67.19 Providing double flanged swing type cast steel valve, ASA-600 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001286 2 Nos
174 67.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 85 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001287 1 No.
175 67.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001288 1 No.
176 67.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001289 1 No.
177 67.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001290 1 Job
178 67.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n BI01010001010000000000000515BI0100001291 10 Rmt.
179 67.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001292 10 Rmt.
180 67.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001293 5 Rmt.
181 67.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001294 10 Rmt.
182 67.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001295 10 Rmt.
183 67.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001296 1 Job
184 68 Pumping Machinery:- Raw Water Stage (Navlay Gharan Phase) :- Supply of submersible pumping set of KSB/Calama/SU/ johnson and other approved make comprising to latest relevant BIS Code. The pump should be fitted with bronze impller of suitable alloys as per BIS 5659-1972 latest suitable for having greased packed bearing and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersibed squirrei cage electric induction motor (water proof type) of required HP RPM 2900 of Kirloskar /NGEF/ Cromption and other approved make make conformining to BIS 9287-1979 latest with upto date amendmednts totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. It should also be fitted with a device to take up expansion of water with heating of motor:-Discharge (Q) - 3.23 LPS for each pump , Total Dynamic heads:- 15.95 Meter ,LWL in sump well(h) -958.00 Meter, Shaft Level - 959.00 Meter, Level at Discharge point -970.00 Meter,Suction Lift -'+ve , Discharge Head -11.00 Meter,Static head =0,Rising Main-Length - 45 Meter ,Dia - 80 mm,Pumping Hours -16 Hours,Altitude of installation above MSL -1000 Meter ,Characterstics of water -Clear Cold Water,Temperature -25 degree centigrade BI01010001010000000000000515BI0100001297 2 Sets
185 68.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001298 1 Set
186 68.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001299 1 No.
187 68.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001300 1 No.
188 68.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001301 1 No.
189 68.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001302 1 No.
190 68.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001303 1 No.
191 68.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001304 1 No.
192 68.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001305 1 No.
193 68.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001306 1 set
194 68.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001307 2 set
195 68.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001308 2 set
196 68.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001309 2 set
197 68.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001310 2 Nos
198 68.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001311 2 Nos
199 68.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001312 2 Nos
200 68.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001313 2 Nos
201 68.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001314 2 Nos
202 68.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001315 2 Nos
203 68.19 Providing double flanged swing type cast iron valve, PH-1.00 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001316 2 Nos
204 68.2 Providing double flanged cast iron reflux valves class, PH-1.00 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001317 1 No.
205 68.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001318 1 No.
206 68.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001319 1 No.
207 68.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001320 1 Job
208 68.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n BI01010001010000000000000515BI0100001321 10 Rmt.
209 68.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001322 10 Rmt.
210 68.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001323 5 Rmt.
211 68.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001324 10 Rmt.
212 68.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001325 10 Rmt.
213 68.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001326 1 Job
214 69 First Stage (Shiva Hataun Phase) :- Providing & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements: Discharge(Q) - 3.23 LPS for each pump,Total Dynamic heads:- 498.77 Meter,LWL in sump well(h) 965.00 Meter, Shaft Level -965.60 Meter,Level at Discharge point 1430.00 Meter,Suction Lift -'+ve ,Discharge Head -464.40 Meter,Static head -0 ,Rising Main-Length -2550 Meter,Dia - 80 mm,Pumping Hours -16 Hours,Altitude of installation above MSL -1000 Meter ,Characterstics of water - Clear Water with turbidity up to 50 PPM,Temperature -25 degree centigrade BI01010001010000000000000515BI0100001327 2 Sets
215 69.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001328 1 Set
216 69.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001329 1 No.
217 69.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001330 1 No.
218 69.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001331 1 No.
219 69.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001332 1 No.
220 69.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001333 1 No.
221 69.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001334 1 No.
222 69.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001335 1 No.
223 69.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001336 1 set
224 69.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001337 2 set
225 69.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001338 2 set
226 69.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001339 2 set
227 69.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001340 2 Nos
228 69.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001341 2 Nos
229 69.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001342 2 Nos
230 69.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001343 2 Nos
231 69.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001344 2 Nos
232 69.18 Providing double flanged cast steel sluice valve, ASA-600 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001345 2 Nos
233 69.19 Providing double flanged swing type cast steel valve, ASA-600 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001346 2 Nos
234 69.2 Providing double flanged cast steel reflux valves class, ASA-600 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 80 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001347 1 No.
235 69.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001348 1 No.
236 69.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001349 1 No.
237 69.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001350 1 Job
238 69.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:a) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n\n BI01010001010000000000000515BI0100001351 10 Rmt.
239 69.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001352 10 Rmt.
240 69.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001353 5 Rmt.
241 69.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001354 10 Rmt.
242 69.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001355 10 Rmt.
243 69.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001356 1 Job
244 70 Second Stage (Shiva Hataun Phase) :- Providing & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:Discharge(Q) 3.02 LPS for each pump,Total Dynamic heads:- 215.20 Meter,LWL in sump well(h) - 1427.00 Meter , Shaft Level - 1427.60 Meter,Level at Discharge point -1630.00 Meter, Suction Lift - '+ve, Discharge Head - 202.40 Meter,Static head = 0, Rising Main-Length 840 Meter,Dia 80 mm dia, Pumping Hours-16 Hours,Altitude of installation above MSL -1400 Meter ,Characterstics of water -Clear Water with turbidity up to 50 PPM,Temperature -25 degree centigrade BI01010001010000000000000515BI0100001357 2 Sets
245 70.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001358 1 Set
246 70.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001359 1 No.
247 70.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001360 1 No.
248 70.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001361 1 No.
249 70.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001362 1 No.
250 70.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001363 1 No.
251 70.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001364 1 No.
252 70.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001365 1 No.
253 70.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001366 1 set
254 70.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001367 2 set
255 70.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001368 2 set
256 70.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001369 2 set
257 70.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001370 2 Nos
258 70.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001371 2 Nos
259 70.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001372 2 Nos
260 70.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001373 2 Nos
261 70.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001374 2 Nos
262 70.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001375 2 Nos
263 70.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001376 2 Nos
264 70.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 80 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001377 1 No.
265 70.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001378 1 No.
266 70.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001379 1 No.
267 70.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001380 1 Job
268 70.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe BI01010001010000000000000515BI0100001381 10 Rmt.
269 70.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001382 10 Rmt.
270 70.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001383 5 Rmt.
271 70.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001384 10 Rmt.
272 70.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001385 10 Rmt.
273 70.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001386 1 Job
274 71 Providing, laying and jointing, testing in trenches galvanised mild steel tubes (Light Class) screwed and socketed, ISI marked, conformining to IS :1239 & latest with upto date ammendments including tube fitting such as bends, tees, air valves, unions and collars etc. as per direction and to the entire satisfaction of the Engineer-in-charge (Earth work in trenches to be measured and paid for separately) in all leads and lifts.65 mm Diameter BI01010001010000000000000515BI0100001387 4470 Rmt
275 71.01 32 mm Diameter BI01010001010000000000000515BI0100001388 2600 Rmt
276 72 Providing and Fixing Brass Stop Cock, Wheel Valve including housing chamber complete in all leads and lifts.65 mm Diameter BI01010001010000000000000515BI0100001389 2 Nos.
277 72.01 32 mm Diameter BI01010001010000000000000515BI0100001390 1 No.
278 73 Providing FHTC to the Balance Households of various villages in GP Kotadhar, Pali, Farsh, Kathyari, Bandhi, Kot Dhalyas, Bhatwari, Aut, Nau and Kigas Tehsil Aut Distt. Mandi (HP)Transportation of suitable truck mounted DTH and ODEX/Percussion Calyx/RC drilling rigs alongwith necessary accessories etc to the site of work and errection of rig including levelling etc. complete in all respects as per the directions of the Engineer-in-Charge in all leads and lifts. BI01010001010000000000000515BI0100001391 1 Nos.
279 74 Drilling bores of 200 mm dia as per IS 2800-1979 from ground level in the overburden as per direction of the Engineer-in-Charge/hydrogeologist with suitable rigs for drilling through rocky formation consisting of sand stone, limestone, dolomites, congiomerate, boulder pebble, gravats, silt, clay or any other type of sedimentary, metamorphic and igneous rocks including cost of attachements consumables stores bils, water, POL etc complete in all respect in all leads and lifts. BI01010001010000000000000515BI0100001392 50 Rmt.
280 75 Supplying and lowering IS marked 200 mm ERW plain casing pipe as per IS 4270-2001 with upto date amendments in a length of 3 metres including cost of cutting welding, transportation charges complete in all respect. The pipe shall be at suitable intervals as per direction of Engineer-in-Charge in all leads and lifts. BI01010001010000000000000515BI0100001393 50 Rmt.
281 76 Providing and fixing suitable casing shoe and bit tube as per requirement of ODEX attachment complete in all respects as per directions of the Engineer-in-Charge in all leads and lifts. BI01010001010000000000000515BI0100001394 1 Nos.
282 77 Collection and preservation of soil samples in polythene bags complete in all respects as per the directions of the Engineer-in-Charge in all leads and lifts. BI01010001010000000000000515BI0100001395 1 Nos
283 78 Development of bore well and yield testing with air compressor through V notch and disinfection etc. complete in all respects as per IS-2800-1979 and as per directions of the Engineer-in-Charge in all leads and lifts. BI01010001010000000000000515BI0100001396 1 Hours
284 79 Cutting in earth work and disposal of excavated earth work in all kinds of soil such as pick work, jumper work, blasting work, chiselling work soft/hard rocks where blasting is prohibited in all leads and lifts. BI01010001010000000000000515BI0100001397 24 cum
285 80 Excavation in foundations trenches etc. ( for pipes and pits ) upto all depths in all kinds of soil such as pick work, jumper work, blasting and chiselling soft/hard rocks where blasting is prohibited in all leads and lifts including trimming and dressing of sides levelling of bed to correct excavation and returning the stacked soil after laying jointing and testing of G.I.Pipes in trenches in 15 cm. layers including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting/timbering and dewatering where ever required including restoration of un-metalled/metalled paved surface of its original conditions including cost of diversion for traffic night signals Fixing caution boards and fencing etc.complete in all respects. BI01010001010000000000000515BI0100001398 47246.8 Cum
286 81 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 crushed stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads & lifts. BI01010001010000000000000515BI0100001399 126.97 Cum
287 82 Providing and laying cement concrete 1:5:10 (1 cement:5 sand: 10 graded stone aggregate 40mm nominal size ) with 15 % plum and curing complete excluding cost of form work in retaining walls/ breast walls, the size of plums shall usually be 150 mm. to 300 mm. as per H.P.P.W.D specifications in all leads and lifts. BI01010001010000000000000515BI0100001400 51.8 Cum
288 83 Providing and laying cement concrete 1:6:12 (1 cement : 6 sand : 12 crushed stone aggreagte 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all leads and lifts. BI01010001010000000000000515BI0100001401 17.6 Cum
289 84 Random rubble masonry /polygonal rubble masonry (uncoursed brought to courses ) with hard stone of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 (1cement:6 sand:12 crushed stone aggregate 20 mm nominal size) at plinth level in cement mortar 1:6 (1 cement : 6 sand) in all leads and lifts. BI01010001010000000000000515BI0100001402 52.75 Cum
290 85 Providing and Fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jump lock jamb,beed and if required angle threshold of mild steel angle of section 50x25mm or base ties of 1.25 mm pressed mild steel welded or rigidly fixed together by mechanical means,adjustable lugs with split and tails to each jamb including steel butt things 2.5 mm thick with guards lock strike plate and shock as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001403 121.94 Rmt
291 86 Brick work using common burnt clay building bricks in foundation and plinth in cement mortar 1:6 (1cement : 6 sand ) in all leads and lifts. 2nd class bricks. BI01010001010000000000000515BI0100001404 69.44 Cum
292 87 Providing form work with steel plates 3.15 mm thick welded with angle iron in frames 30x30x5 mm, so as to give a fair finish including centering ,shuttering, propping etc.with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in:-Foundation footings bases of columns and the like and mass concrete in all leads and lifts. BI01010001010000000000000515BI0100001405 25.68 Sqm
293 87.01 Beam, cantilever, girders and lintels, sides and soffits of beam, beam haunching, cantilever, bressumers and lintels not exceeding 1 mtr. In depth in all heights from floor in all leads and lifts. BI01010001010000000000000515BI0100001406 21.72 Sqm
294 87.02 Vertical surface such as walls(any thickness) partitions and the like including attached pillasters, butteresses, plinth and string courses and the like in all leads & lifts. BI01010001010000000000000515BI0100001407 2439.33 Sqm
295 87.03 Flat surfaces such as soffits of suspended floors, roofs landings and the like: floors etc. up to 200 mm in thickness in all leads & lifts. BI01010001010000000000000515BI0100001408 389.08 Sqm
296 88 Providing form work of ordinary timber plankings so as to give a rough finish including centering, shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plaiin concrete work in:- Arches, domes, vaults up to all span in all leads and lifts. BI01010001010000000000000515BI0100001409 73.47 Sqm
297 89 Providing and laying cement concrete 1:11/2 :3 ( 1cement : 1 1/2 sand: 3 crushed stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Foundation footings bases of columns and the like and mass concrete in all leads and lifts. BI01010001010000000000000515BI0100001410 78.07 Cum
298 89.01 Walls (any thickness but not less than 0.1 mtr thickness) attached pilasters, buttresses, plinth and string courses etc. from top of foundation level up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001411 169.08 Cum
299 90 Providing and laying cement concrete 1:2:4 ( 1 cement : 2 sand : 4 crushed stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Foundation footings bases of columns and the like and mass concrete in all leads and lifts. BI01010001010000000000000515BI0100001412 37.58 Cum
300 90.01 Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001413 49.4 Cum
301 90.02 Dome roofs, landings shelves and their supports balconies, beams, girders, bressumers and cantilevers etc. any shape in all leads & lifts. BI01010001010000000000000515BI0100001414 7.04 Cum
302 91 Providing and laying Tor Steel reinforcement for reinforcement cement concrete work including bending, binding and placing in position includig the cost of binding wire and cutting in all leads and lifts as per the directions of the Enginerer-in-Charge. BI01010001010000000000000515BI0100001415 31038.4 Kg
303 92 Boulder filling under floor complete in all leads and lifts. BI01010001010000000000000515BI0100001416 26.78 Cum
304 93 Half bricks masonry in common burnt clay building bricks in cement mortar 1:4 (1cement:4 sand) in all leads and lifts. 2nd class Bricks. BI01010001010000000000000515BI0100001417 12.64 Sqm
305 94 Pointing on brick work with cement mortor 1:3 (1cement : 3 sand) Raised and Cut in all leads and lifts. BI01010001010000000000000515BI0100001418 230.04 Sqm
306 95 Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3 ( 1 cement :3 sand ) over a 12 mm layer of C.M 1:3 ( 1 cement : 3 sand ) and finished neat with in all leads and lifts complete in all respect in all leads and lifts. BI01010001010000000000000515BI0100001419 24.96 Sqm
307 96 6 mm cement plaster to ceiling in cement mortor 1:3 (1 cement : 3 Sand) complete in all leads and lifts. BI01010001010000000000000515BI0100001420 198.57 Sqm
308 97 15 mm thick cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering upto floor two level brick/concrete/stone walls for interior plastering upto floor two levels including arrises internal rounded angles chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smoothing cement mortar 1:6 (1cement:6 sand) in all leads and lifts. BI01010001010000000000000515BI0100001421 201.18 Sqm
309 98 20 mm thick cement plaster in single coat on rough side of brick/stone/concrete walls for interior plastering up to floor two level including arrisses,internal rounded angles,chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smooth with in all leads and lifts in C.M 1:6 ( 1 cement : 6 sand ) in all leads and lifts. BI01010001010000000000000515BI0100001422 31.1 Sqm
310 99 White glazed tiles 6 mm thick in flooring cement mortar 1:3 (1cement : 3 sand) finished with flush pointing in white cement in all leads and lifts. BI01010001010000000000000515BI0100001423 2.16 Sqm
311 100 White glazed tiles 6 mm thick in skirting risers of steps and dado 12 mm thick cement mortar 1 :3 ( 1 cement : 3 sand ) and jointed with cement slurry in all leads and lifts. BI01010001010000000000000515BI0100001424 3.06 Sqm
312 101 Providing and Fixing panneled glazed or panelled and glazed shutters for doors, windows and clerestory windows,including black enamelled iron butt hinges with necessary screws. 40 mm thick. 2nd class deodar wood in all leads and lifts. BI01010001010000000000000515BI0100001425 26.01 Sqm
313 102 Providing & fixing M.S. grills of required pattern in wooden frame of window etc.with M.S. flats, square or round barswith round headedbolts and nuts by screws plain grills in all leads and lifts. BI01010001010000000000000515BI0100001426 143 Kg
314 103 Providing and fixing wire gauge shutters using galvanised M.S. wire gauge of IS gauge specification 8 S.G with wire of dia 0.56 mm for doors,windows i/c bright finished black enamelled iron butt hinges with necessary screws 30 mm thick of 2nd class deodar wood with in all leads and lifts complete in all respect. BI01010001010000000000000515BI0100001427 28.68 Sqm
315 104 Providing and Fixing anodized MS sliding door bolts with bolts and nuts screws etc.complete. 300 x 16 mm in all leads and lifts. BI01010001010000000000000515BI0100001428 5 Nos.
316 105 Providing and Fixing anodized MS tower bolts(barrel type)with screws etc.complete in all leads and lifts.250X10 mm BI01010001010000000000000515BI0100001429 61 Nos.
317 105.01 150X10 mm BI01010001010000000000000515BI0100001430 1 Nos.
318 106 Providing and Fixing anodized MS handles with necessary screws etc. complete in all leads and lifts..125 mm BI01010001010000000000000515BI0100001431 1 No.
319 106.01 100 mm BI01010001010000000000000515BI0100001432 41 Nos.
320 107 White washing with lime on undecorated wall surfaces two coats to give an even shade including thoroughly brooming the surface to remove all dirt,dust and other foreign matters in all leads and lifts. BI01010001010000000000000515BI0100001433 195.06 Sqm
321 108 Distempering with dry distemper of approved brand and manufacture (two coats)and of required shade on un-decorated wall surface to give an even shade sand papered smooth in all leads and lifts. BI01010001010000000000000515BI0100001434 204.69 Sqm
322 109 Finishing wall with water proofing cement paint of approved brand and manufacture (two coats) brushing to give an even shade I/c cleaning of oil,dirt,dust and other foreign matters,sand papering and knotting etc. with in all leads and lifts complete in all respect in all leads and lifts. BI01010001010000000000000515BI0100001435 31.1 Sqm
323 110 Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,grease,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink in all leads and lifts. BI01010001010000000000000515BI0100001436 52.22 Sqm
324 111 Painting two coats (excluding priming coat)on new wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of dirt,dust and other foreign matters sand papering and stopping with enamel paint other than white in all leads and lifts. BI01010001010000000000000515BI0100001437 52.22 Sqm
325 112 Precast terrazzo tiles hydraulic compressed 20 mm thick with marble chips of specified size in flooring cement mortar 1:6 (1cement : 6 sand) jointed with neat cement slurry. (Dark shade) in all leads and lifts. BI01010001010000000000000515BI0100001438 101.6 Sqm
326 113 Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1cement : 3 sand : 6 crushed stone aggregate 20 mm nominal size) in all leads and lifts. BI01010001010000000000000515BI0100001439 33.16 Sqm
327 114 Constructing coursed rubble hammer dressed "U" shape open surface drain with side wall 15 X 22 cm in cementy mortar 1:6 ( 1 cement, 6 sand ) and inside plastering with cement mortar 1:3 ( 1 cement, 3 sand ) i/c earth work and laying 10 cms cement concrete in 1:5;10 ( 1 cement,5 sand,10 graded stone aggregate 40 mm nominal size ) and 7.5 cms cement concrete 1:2:4 ( 1 cement,2 sand,4 graded stone aggregate 20 mm nominal size ) and finished with a floating coat of neat cement complete as per standard design with in all leads and lifts complete in all respect. BI01010001010000000000000515BI0100001440 73.7 Rmt
328 115 Providing and Fixing of Steel / fibre reinforcement concrete (SFRC) manhole cover with frame conforming to IS-12592 (Part - I)-1998 with latest ammendments 560 mm dia medium duty in all leads and lifts. BI01010001010000000000000515BI0100001441 17 Nos.
329 116 Supplying and fixing of cast iron manhole cover with frame 455 x 610 mm rectangular C.I. cover (light duty) single seal pattern the weight of cover 23 Kg. and weight of frame 15 Kg. The total weight of cover and frame to be not less than 38 Kg. compelete in all leads and lifts. BI01010001010000000000000515BI0100001442 1 No.
330 117 Providing and Fixing cast iron rungs 200 mm wide with chequered of ribbed non slip surface including Fixing in manhole with 200x200x100 mm cement concrete 1:3:6 (1 cement:3 sand:6 graded stone aggregate 20mm nominal size) in all leads and lifts. BI01010001010000000000000515BI0100001443 20 Nos.
331 118 Providing and Fixing of G.I. pipe dia mentioned below for inlet, outlet and scour pipe etc in all leads and lifts.100 mm diameter BI01010001010000000000000515BI0100001444 36 Rmt
332 119 Providing and Fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including Fixing with approved adhesive etc. complete in all leads and lifts.110 mm nominal bore. BI01010001010000000000000515BI0100001445 4 Rmt
333 120 Providing and Laying in retaining walls and breast walls 10.00 Kgf/Cm2 working pressure unplasticized P.V.C. pipes (Conforming to IS:4985-1968) to make weep holes complete including making good the walls in all leads and lifts. BI01010001010000000000000515BI0100001446 51 Rmt
334 121 Providing and Fixing of MS Fabricated Protection Panel 750 mm x 750 mm made with MS Angle 40 x 40 x 4 mm for frame, MS Angle 30 x 30 x 3 mm for cover, MS Flat 25 x 5 mm for Fixing of sliding door bolt and MS Sheet 4.00 mm thick for protection of manhole covers of storage tanks including the cost of cutting and welding of MS angle, MS Flat & MS Sheet, embedding in RCC Slab by drilling holes in MS angle & in RCC slab, provision for providing and Fixing sliding door bolt 300 x 16 mm, MS Handle 100 mm, Lock and applying a coat of red lead paint & painting two coat with steel paint (Firoza Blue) complete job in all respect in all leads and lifts and to the entire satisfaction of the Engineer - in - Charge. BI01010001010000000000000515BI0100001447 47 Nos.
335 122 1.20 metre heigh fencing (as per approved design) 1.80 metres R.C.C.posts 3 metres centre to centre and R.C.C. struts with 7 horizental lines and two diagonals of galvanised steel bar bed wire (IS 278-1962 type I) weighing 9.38 kg./100 metres (minimum) strained and fixed to posts by typing to 6mm galvanised steel bar niles/clips with G.I. binding wire including cost of Excavation, R.C.C. Posts,R.C.C. struts and straining belts and embeded in cement concrete 1:4:8 ( 1cement : 4 sand : 8 graded stone aggregate 40 mm nominal size) and curing complete in all respect with manufacturing & Fixing of MS Gate 1.20X1.50 Meter and to the entire satisfaction of the Engineer-in-Charge. BI01010001010000000000000515BI0100001448 61.65 Rmt
336 123 Providing and placing in horizontal layers filtering media duly graded,screened,washed and cleaned as specified by the Engineer in charge in all leads and lifts.Top Layer :-FineSand Screened, washed, cleaned & graded from 2.00 mm to 3.00 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001449 56.7 Cum
337 123.01 2nd Layer :-Coursed sand screened, cleaned, washed & graded 3 mm to 6 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001450 7.5 Cum
338 123.02 3rd Layer :-Bajri screaned, washed and graded 6 mm to 20 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001451 7.5 Cum
339 123.03 4th Layer :-Bajri screaned, washed & graded 20 mm to 25 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001452 7.5 Cum
340 123.04 5th Layer :- Brocken stone screaned, washed and graded for 50 mm to 75 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001453 11.4 Cum
341 124 Providing and placing Ist class standard bricks in filter bed in two layers so as to make cross drains as per direction of Engineer-in-charge in all leads and lifts. BI01010001010000000000000515BI0100001454 11550 Nos.
342 125 Providing and fixing automatic flushing cistern with a pair of CI or MS bracket complete with fitting including CI Syphonic apprature masquits proof lid, CP brass unions and coupling for connecting with inlet outlet and over flow pipes including cutting holes and making good the same Over flow pipe to be measured and paid for seperately (Viterous china 5 liters capacity in all leads and lifts. BI01010001010000000000000515BI0100001455 1 No.
343 126 Providing and fixing vitreous china wash down water closet (Indian Type, W.C pan) with integral P or S trap including jointing the trap with soil pipe in cement mortar 1 : 1 ( 1 cement 1 sand) ( Seat and cover to be measured and paid for separately) (White colour) in all leads and lifts. BI01010001010000000000000515BI0100001456 1 No.
344 127 Providing and fixing 100 mm size P or S trap for water closet ( Squatting Pan) including jointing the trap with the pan and soil pipe in cement mortar 1:1 ( 1cement : 1 sand) Sand cast iron in all leads and lifts. BI01010001010000000000000515BI0100001457 1 No.
345 128 Providing & fixing viterious china wash basin with single hole for pillar tap with CI or MS bracket painted white including cutting hole including good the same excluding fitting Cera sanitary work (cornet) white 550x400 white in all leads and lifts. BI01010001010000000000000515BI0100001458 1 No.
346 129 Providing and fixing viterious china padestral for wash basin complete recessed at the basic for reception of pipe and fittings Cera sanitary work (carnet) white (Viterious China in White Colour) in all leads and lifts. BI01010001010000000000000515BI0100001459 1 No.
347 130 Providing and Fixing of water storage tank sintex having of capacity 500 liters with necessary fittings including over flow pipes, scour pipes etc. inlet and outlet and inside paint of required size for inlet or outlet and inside paint of approved quality complete including hoisting complete in all respects in all leads and lifts. BI01010001010000000000000515BI0100001460 1 No.
348 131 Providing and fixing on wall face PVC (D - Plast) rain water pipes of working pressure not less 4.5 Kg/Sqcm including fitting the joints with approved adhesive complete with in all leads , lifts and carriage of materials.110 mm nominal bore in all leads and lifts. BI01010001010000000000000515BI0100001461 10 Meters
349 132 Providing and fixing on wall faces PVC door bend (D-Plast) with oval access door, insertion rubber washer 3 mm thick bolts and nuts ISI marked complete including fixing with approved adhesive complete.75 mm nominal bore in all leads and lifts. BI01010001010000000000000515BI0100001462 6 Nos.
350 133 Providing and fixing to wall ceiling and floor galvanised mild steel tubes (Medium grade) tube fittings and clamp including making good the wall ceiling and floor in all leads and lifts.) 15 mm nominal bore in all leads and lifts. BI01010001010000000000000515BI0100001463 10 Nos.
351 134 Providing and fixing full way wheel valve 15 mm dia Gun metal in all leads and lifts. BI01010001010000000000000515BI0100001464 1 No.
352 135 Providing and fixing cast iron spun soil waste and ventilating pipe lead caulked joint to be measured and paid for separately 100mm dia with C.I cowl 100 mm dia nominal size in all leads and lifts. BI01010001010000000000000515BI0100001465 1 No.
353 136 Providing and fixing brass bib tap (superior qualityor heavy type) 15 mm dia in all leads and lifts. BI01010001010000000000000515BI0100001466 1 No.
354 137 Providing & Fixing CP Brass Soap Dish with CP breckets fixed to wodden plugs with CP brass screws complete in all respect in all leads and lifts. BI01010001010000000000000515BI0100001467 1 No.
355 138 Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required Group C. BI01010001010000000000000515BI0100001468 42 Nos.
356 139 Wiring for circuit / sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.2 x 1.50 Sq. mm. BI01010001010000000000000515BI0100001469 88 Rmt
357 139.01 2 x 4.00 Sq. mm. BI01010001010000000000000515BI0100001470 44 Rmt
358 140 Supplying and fixing 3 pin 5/6 amps. Socket outlet on the exists switch box/covers including connections etc. as required. BI01010001010000000000000515BI0100001471 15 Nos.
359 140.01 Supplying and fixing 2 way 5/6 amps. Tumbler/piano type switch on the existing switch box on the switch box/cover including connections etc. as required. BI01010001010000000000000515BI0100001472 15 Nos.
360 141 Supplying and fixing 3 pin 15/16 amps. Socket outlet on the exists switch box/covers including connections etc. as required. BI01010001010000000000000515BI0100001473 5 Nos.
361 141.01 Supplying and fixing 15/16 amps. Tumbler/piano type switch on the existing switch box on the switch box/cover including connections etc. as required. BI01010001010000000000000515BI0100001474 5 Nos.
362 142 Supplying and fixing wooden box of following size (nominal) on surface or recess with suitable size of phenolic laminated sheet cover of in front as required.229 mm.x 102 mm.x 60 mm. deep BI01010001010000000000000515BI0100001475 5 Nos.
363 142.01 203 mm.x152 mm.x 60 mm. deep BI01010001010000000000000515BI0100001476 5 Nos.
364 143 Supplying and fixing ceiling rose on existing junction box/ wooden block including connections etc. as required. BI01010001010000000000000515BI0100001477 16 Nos.
365 144 Supplying and fixing plain pandent with 16/20 mm twin twisted, flexible PVC insulated copper cable and backelite pendant holder including connections, etc. as required. BI01010001010000000000000515BI0100001478 6 Nos.
366 145 Supplying and Fixing 5 Amps to 32 Amps rating, 240 Volts, L series miniature circuit breaker of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required Cat - A. (Single Pole) BI01010001010000000000000515BI0100001479 12 Nos.
367 146 Supplying and Fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 Volts on surface/ recess, complete with tinned copper busbar, netural link, earthbar, dibnbar, detachable gland plates, inter connections, i/c painting, earthing etc. as required busbar 8 way. BI01010001010000000000000515BI0100001480 2 Nos.
368 147 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (63 amp. CAT - A) BI01010001010000000000000515BI0100001481 2 Nos.
369 148 Providing, installing, testing and commissioning of ceiling fan and regulator i/c wiring the down rod of standard length (upto 30 Cm with 1.5 Sqmm PVC insulated copper conductor signle core cable etc. as required.Ceiling fan 1400 mm sweep category A BI01010001010000000000000515BI0100001482 4 Nos.
370 149 Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast, snap-on installers, suitable for 28 watt FTL (T5), complete with all accessories (including one No. T-5 Tube), connections, testing and commissioning etc. as required 1 x28 watt-FTL (T5) (Category-A) BI01010001010000000000000515BI0100001483 6 Nos.
371 150 Providing and Fixing LED Flood Light watt mentioned below (OREVA make) complete in all respect in all leads and lifts. BI01010001010000000000000515BI0100001484 4 Nos.
372 151 Providing and fixing two core service wire 6 Sqmm thick in all leads and lifts. BI01010001010000000000000515BI0100001485 60 Rmt
373 152 Providing , laying, fixing, jointing and testing in trenches MS pipe of following dia meters confirming to confirming to BIS 3183-2007, of following grade and having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).First Stage :-100 mm diameter MS Pipe (L-360 or X-46) 5.70 mm thickness with Flane Table-38 BI01010001010000000000000515BI0100001486 35 Rmt
374 152.01 100 mm diameter MS Pipe (L-360 or X-46) 4.00 mm thickness with Flane Table-34 BI01010001010000000000000515BI0100001487 15 Rmt
375 152.02 Second Stage :-80 mm diameter MS Pipe (L-290 or X-42) 4.40 mm thickness with Flane Table-38 BI01010001010000000000000515BI0100001488 35 Rmt
376 152.03 80 mm diameter MS Pipe (L-290 or X-42) 4.00 mm thickness with Flane Table-34 BI01010001010000000000000515BI0100001489 40 Rmt
377 153 Providing , laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of MS pipe of following dia meters confirming to BIS 3183-2007, steel grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).First Stage :-100 mm diameter MS Pipe (L-360 or X-46) 5.70 mm thickness BI01010001010000000000000515BI0100001490 665 Rmt
378 153.01 100 mm diameter MS Pipe (L-360 or X-46) 4.00 mm thickness BI01010001010000000000000515BI0100001491 285 Rmt
379 153.02 Second Stage :-80 mm diameter MS Pipe (L-290 or X-42) 4.40 mm thickness BI01010001010000000000000515BI0100001492 665 Rmt
380 153.03 80 mm diameter MS Pipe (L-290 or X-42) 4.00 mm thickness BI01010001010000000000000515BI0100001493 760 Rmt
381 154 Providing, laying, jointiong and testing in trenches GMS pipe of following dia meters confirming to BIS: 1239 (Part-i),of following grade having wall thickness as specified below with plain end and capable of with standing required test pressure in random length of 4 to 7 meters, including special, short pieces , beds reducers, tees etc. made from parent tube providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392 - 1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3 mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing , providing and fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge . The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipe shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carrage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts (Earth work in trenches will be measured and paid for separately)First Stage :-100 mm dia-GMS pipe 4.50 mm thickness with Flange Table-28 (Medium Class) BI01010001010000000000000515BI0100001494 25 Rmt.
382 154.01 100 mm dia-GMS pipe 4.50 mm thickness with Flange Table-17 (Medium Class) BI01010001010000000000000515BI0100001495 40 Rmt.
383 154.02 100 mm dia-GMS pipe 4.50 mm thickness with Flange Table-5 (Medium Class) BI01010001010000000000000515BI0100001496 30 Rmt.
384 154.03 Second Stage :-80 mm dia-GMS pipe 4.80 mm thickness with Flange Table-28 (Medium Class) BI01010001010000000000000515BI0100001497 65 Rmt.
385 154.04 80 mm dia-GMS pipe 4.00 mm thickness with Flange Table-17 (Medium Class) BI01010001010000000000000515BI0100001498 20 Rmt.
386 154.05 80 mm dia-GMS pipe 4.00 mm thickness with Flange Table-5 (Medium Class) BI01010001010000000000000515BI0100001499 30 Rmt.
387 155 Providing, laying, jointiong and testing (by way of circumfrential butt welded joints by electrical arc welding) and testing of GMS pipe of following dia meters confirming to BIS: 1239 (Part-i) grade specified below (latest withup to date amendments ) having wall thickness as specified below with bevelled ends and capable of with standing required test pressure in random length of 4 to 7 meters, including manufacturing reducers tapers , all short pieces, beds etc. as per site requirement made from parent tubes. The laying of pipe will include all operation such as cutting, welding , jointing , fabrication of bends , tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge . The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipe shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carrage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts (Earth work in trenches will be measured and paid for separately)Booster Stage :-80 mm dia-GMS pipe 4.00 mm thickness (Medium Class) BI01010001010000000000000515BI0100001500 100 Rmt.
388 155.01 First Stage :-100 mm dia-GMS pipe 4.50 mm thickness (Medium Class) BI01010001010000000000000515BI0100001501 1805 Rmt.
389 155.02 Second Stage :-80 mm dia-GMS pipe 4.00 mm thickness (Medium Class) BI01010001010000000000000515BI0100001502 2185 Rmt.
390 156 Booster Stage :-Pumping Machinery:- Supply of submersible pumping set of KSB/Calama/SU/ johnson and other approved make comprising to latest relevant BIS Code. The pump should be fitted with bronze impller of suitable alloys as per BIS 5659-1972 latest suitable for having greased packed bearing and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersibed squirrei cage electric induction motor (water proof type) of required HP RPM 2900 of Kirloskar /NGEF/ Cromption and other approved make make conformining to BIS 9287-1979 latest with upto date amendmednts totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. It should also be fitted with a device to take up expansion of water with heating of motor:- Discharge (Q) -3.69 LPS for each pump,Total Dynamic heads:- 53.79 Meter, LWL in sump well(h) -1016.00 Meter, Shaft Level -1015.00 Meter,Level at Discharge point- 1065.00 , Suction Lift - '+ve , Discharge Head -50.00 Meter,Static head- 50.00 Meter,Rising Main Length-100 Meter,Dia - 80 mm..,Pumping Hours - 8 Hours,Altitude of installation above MSL - 1000 Meter, Characterstics of water - Clear Cold Water,Temperature 25 degree centigrade- BI01010001010000000000000515BI0100001503 2 Sets
391 156.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001504 1 Set
392 156.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001505 1 No.
393 156.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001506 1 No.
394 156.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001507 1 No.
395 156.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001508 1 No.
396 156.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001509 1 No.
397 156.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001510 1 No.
398 156.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001511 1 No.
399 156.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001512 1 set
400 156.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001513 2 set
401 156.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001514 2 set
402 156.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001515 2 set
403 156.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001516 2 Nos
404 156.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001517 2 Nos
405 156.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001518 2 Nos
406 156.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001519 2 Nos
407 156.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001520 2 Nos
408 156.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001521 2 Nos
409 156.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001522 2 Nos
410 156.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001523 1 No.
411 156.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001524 1 No.
412 156.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001525 1 No.
413 156.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001526 1 Job
414 156.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:a) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n\n BI01010001010000000000000515BI0100001527 10 Rmt.
415 156.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001528 10 Rmt.
416 156.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001529 5 Rmt.
417 156.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001530 10 Rmt.
418 156.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001531 10 Rmt.
419 156.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001532 1 Job
420 157 First Stage :-Providing & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements: Discharge(Q) - 7.38 LPS for each pump,Total Dynamic heads:- 724.55 Meter,LWL in sump well(h) - 1063.00 Meter , Shaft Level - 1062.00 Meter,Level at Discharge point -1730.00 Meter, Suction Lift - '+ve , Discharge Head - 668.00 Meter,Static head -668.00 Meter,Rising MainLength - 2900 Meter,Dia - 100 mm ,Pumping Hours - 4 Hours,Altitude of installation above MSL -1000 Meter , Characterstics of water - Clear Cold Water ,Temperature - 25 degree centigrade BI01010001010000000000000515BI0100001533 2 Sets
421 157.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001534 1 Set
422 157.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001535 1 No.
423 157.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001536 1 No.
424 157.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001537 1 No.
425 157.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001538 1 No.
426 157.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001539 1 No.
427 157.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001540 1 No.
428 157.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001541 1 No.
429 157.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001542 1 set
430 157.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001543 2 set
431 157.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001544 2 set
432 157.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001545 2 set
433 157.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001546 2 Nos
434 157.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001547 2 Nos
435 157.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001548 2 Nos
436 157.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001549 2 Nos
437 157.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001550 2 Nos
438 157.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001551 2 Nos
439 157.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001552 2 Nos
440 157.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001553 1 No.
441 157.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001554 1 No.
442 157.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001555 1 No.
443 157.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001556 1 Job
444 157.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n BI01010001010000000000000515BI0100001557 10 Rmt.
445 157.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001558 10 Rmt.
446 157.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001559 5 Rmt.
447 157.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001560 10 Rmt.
448 157.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001561 10 Rmt.
449 157.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001562 1 Job
450 158 Second Stage :-Providing & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following (requirements:Discharge(Q) -4.76 LPS for each pump,Total Dynamic heads:- 595.49 Meter,LWL in sump well(h) - 1721.00 Meter ,Shaft Level - 1720.00 Meter,Level at Discharge point - 2220.00 Meter, Suction Lift - '+ve ,Discharge Head -500.00 Meter,Static head - 500.00 Meter Rising Main Length - 3800 Meter,Dia-80 mm,Pum,ping - 4 Hours,Altitude of installation above MSL - 1000 Meter , Characterstics of water -Clear Cold Water Temperature - 25 degree centigrade BI01010001010000000000000515BI0100001563 2 Sets
451 158.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001564 1 Set
452 158.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001565 1 No.
453 158.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001566 1 No.
454 158.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001567 1 No.
455 158.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001568 1 No.
456 158.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001569 1 No.
457 158.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001570 1 No.
458 158.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001571 1 No.
459 158.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001572 1 set
460 158.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001573 2 set
461 158.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001574 2 set
462 158.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001575 2 set
463 158.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001576 2 Nos
464 158.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001577 2 Nos
465 158.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001578 2 Nos
466 158.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001579 2 Nos
467 158.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001580 2 Nos
468 158.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001581 2 Nos
469 158.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001582 2 Nos
470 158.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001583 1 No.
471 158.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001584 1 No.
472 158.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001585 1 No.
473 158.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001586 1 Job
474 158.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n BI01010001010000000000000515BI0100001587 10 Rmt.
475 158.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001588 10 Rmt.
476 158.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001589 5 Rmt.
477 158.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001590 10 Rmt.
478 158.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001591 10 Rmt.
479 158.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001592 1 Job
480 159 Providing, laying and jointing, testing in trenches galvanised mild steel tubes (Light Class) screwed and socketed, ISI marked, conformining to IS :1239 & latest with upto date ammendments including tube fitting such as bends, tees, air valves, unions and collars etc. as per direction and to the entire satisfaction of the Engineer-in-charge (Earth work in trenches to be measured and paid for separately) in all leads and lifts.65 mm Diameter BI01010001010000000000000515BI0100001593 3100 Rmt
481 159.01 50 mm Diameter BI01010001010000000000000515BI0100001594 6950 Rmt
482 159.02 40 mm Diameter BI01010001010000000000000515BI0100001595 18700 Rmt
483 159.03 32 mm Diameter BI01010001010000000000000515BI0100001596 33500 Rmt
484 159.04 25 mm Diameter BI01010001010000000000000515BI0100001597 15500 Rmt
485 159.05 20 mm Diameter BI01010001010000000000000515BI0100001598 27400 Rmt
486 159.06 15 mm Diameter BI01010001010000000000000515BI0100001599 24150 Rmt
487 160 Providing and Fixing Brass Stop Cock, Wheel Valve including housing chamber complete in all leads and lifts.65 mm Diameter BI01010001010000000000000515BI0100001600 5 Nos.
488 160.01 50 mm Diameter BI01010001010000000000000515BI0100001601 20 Nos.
489 160.02 40 mm Diameter BI01010001010000000000000515BI0100001602 40 Nos.
490 160.03 32 mm Diameter BI01010001010000000000000515BI0100001603 50 Nos.
491 160.04 25 mm Diameter BI01010001010000000000000515BI0100001604 50 Nos.
492 160.05 20 mm Diameter BI01010001010000000000000515BI0100001605 45 Nos.
493 160.06 15 mm Diameter BI01010001010000000000000515BI0100001606 60 Nos.
494 161 Providing FHTC to the Balance Households of LWSS Kathwari and LWSS Dhanyari and its adjoining villages in GP Bir, Kasan, Sadoh, Tarnoh, Bari Gumanu & Sadyana Tehsil Sadar Distt. Mandi (HP)Excavation in foundations trenches etc. ( for pipes and pits ) upto all depths in all kinds of soil such as pick work, jumper work, blasting and chiselling soft/hard rocks where blasting is prohibited in all leads and lifts including trimming and dressing of sides levelling of bed to correct excavation and returning the stacked soil after laying jointing and testing of G.I.Pipes in trenches in 15 cm. layers including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting/timbering and dewatering where ever required including restoration of un-metalled/metalled paved surface of its original conditions including cost of diversion for traffic night signals Fixing caution boards and fencing etc.complete in all respects. BI01010001010000000000000515BI0100001607 3276.58 Cum
495 162 Providing and laying cement concrete 1:4:8 (1 cement : 4 sand : 8 crushed stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads & lifts. BI01010001010000000000000515BI0100001608 44.21 Cum
496 163 Providing form work with steel plates 3.15 mm thick welded with angle iron in frames 30x30x5 mm, so as to give a fair finish including centering ,shuttering, propping etc.with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in:-Vertical surface such as walls(any thickness) partitions and the like including attached pillasters, butteresses, plinth and string courses and the like in all leads & lifts. BI01010001010000000000000515BI0100001609 394.94 Sqm
497 163.01 Flat surfaces such as soffits of suspended floors, roofs landings and the like: floors etc. up to 200 mm in thickness in all leads & lifts. BI01010001010000000000000515BI0100001610 8.67 Sqm
498 164 Providing and laying cement concrete 1:11/2 :3 ( 1cement : 1 1/2 sand: 3 crushed stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Foundation footings bases of columns and the like and mass concrete in all leads and lifts. BI01010001010000000000000515BI0100001611 12.23 Cum
499 164.01 Walls (any thickness but not less than 0.1 mtr thickness) attached pilasters, buttresses, plinth and string courses etc. from top of foundation level up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001612 40.87 Cum
500 165 Providing and laying cement concrete 1:2:4 ( 1 cement : 2 sand : 4 crushed stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001613 1.2 Cum
501 166 Providing and laying Tor Steel reinforcement for reinforcement cement concrete work including bending, binding and placing in position includig the cost of binding wire and cutting in all leads and lifts as per the directions of the Enginerer-in-Charge. BI01010001010000000000000515BI0100001614 2945.1 Kg
502 167 Providing and Fixing of G.I. pipe dia mentioned below for inlet, outlet and scour pipe etc in all leads and lifts. BI01010001010000000000000515BI0100001615 36 Rmt
503 168 Providing and Fixing Cast Iron Sluice Valve of BIR make BIS No. 14846 with flange Table - 5 including welding of flanges, Nuts & Bolts and Gasket etc.The sluice valve conforming to IS - 780. The dia of valve as mentioned below complete in all leads and lifts and to the entire satisfaction of the Engineer - in - Charge. 100 MM Diameter Table - 5 BI01010001010000000000000515BI0100001616 5 Nos.
504 169 Providing and Fixing of MS Fabricated Protection Panel 750 mm x 750 mm made with MS Angle 40 x 40 x 4 mm for frame, MS Angle 30 x 30 x 3 mm for cover, MS Flat 25 x 5 mm for Fixing of sliding door bolt and MS Sheet 4.00 mm thick for protection of manhole covers of storage tanks including the cost of cutting and welding of MS angle, MS Flat & MS Sheet, embedding in RCC Slab by drilling holes in MS angle & in RCC slab, provision for providing and Fixing sliding door bolt 300 x 16 mm, MS Handle 100 mm, Lock and applying a coat of red lead paint & painting two coat with steel paint (Firoza Blue) complete job in all respect in all leads and lifts and to the entire satisfaction of the Engineer - in - Charge. BI01010001010000000000000515BI0100001617 1 No.
505 170 Providing and placing in horizontal layers filtering media duly graded,screened,washed and cleaned as specified by the Engineer in charge in all leads and lifts.Top Layer :-FineSand Screened, washed, cleaned & graded from 2.00 mm to 3.00 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001618 69.05 Cum
506 170.01 2nd Layer :-Coursed sand screened, cleaned, washed & graded 3 mm to 6 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001619 9.21 Cum
507 170.02 3rd Layer :-Bajri screaned, washed and graded 6 mm to 20 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001620 9.21 Cum
508 170.03 4th Layer :-Bajri screaned, washed & graded 20 mm to 25 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001621 9.21 Cum
509 170.04 5th Layer :- Brocken stone screaned, washed and graded for 50 mm to 75 mm from approved quarry in all leads and lifts. BI01010001010000000000000515BI0100001622 13.81 Cum
510 171 Providing and placing Ist class standard bricks in filter bed in two layers so as to make cross drains as per direction of Engineer-in-charge in all leads and lifts. BI01010001010000000000000515BI0100001623 4083 Nos.
511 172 (CENTRIFUGAL STAGE) LWSS Dhanyari 1st Stage Providing & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:(Discharge(Q- 18.87 LPS for each pump,Total Dynamic heads:-362.64 Meter,LWL in sump well(h)-868.00 Meter , Shaft Level - 867.00 Meter,Level at Discharge point-1213.00 Meter, Suction Lift - '+ve ,Discharge Head -346.00 Meter,Static head -346.00 Meter Rising Main Length 960 Meter, Dia- 150 mm, Pumping Hours -10.50 Hours,Altitude of installation above MSL -900 Meter ,Characterstics of water -Clear Cold Water ,Temperature -25 degree centigrade. BI01010001010000000000000515BI0100001624 1 Set
512 172.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001625 1 Set
513 172.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001626 1 No.
514 172.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001627 1 No.
515 172.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001628 1 No.
516 172.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001629 1 No.
517 172.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001630 1 No.
518 172.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001631 1 No.
519 172.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001632 1 No.
520 172.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001633 1 set
521 172.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001634 1 set
522 172.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001635 1 set
523 172.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001636 1 set
524 172.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001637 1 Nos
525 172.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001638 1 Nos
526 172.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001639 1 Nos
527 172.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001640 1 Nos
528 172.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001641 1 Nos
529 172.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001642 1 Nos
530 172.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001643 1 Nos
531 172.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001644 1 No.
532 172.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001645 1 No.
533 172.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001646 1 No.
534 172.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001647 1 Job
535 172.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n BI01010001010000000000000515BI0100001648 10 Rmt.
536 172.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001649 6 Rmt.
537 172.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001650 10 Rmt.
538 172.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001651 10 Rmt.
539 172.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001652 10 Rmt.
540 172.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001653 1 Job
541 173 (CENTRIFUGAL STAGE) LWSS Dhanyari 2nd StageProviding & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:Discharge(Q) - 14.99 LPS for each pump,Total Dynamic heads:- 522.15 Meter,LWL in sump well(h) -1211.00 Meter, Shaft Level - 1210.00 Meter , Level at Discharge point - 1695.00 Meter , Suction Lift -'+ve ,Discharge Head- 485.00 Meter,Static head -485.00 Meter,Rising Main - Length 3640 Meter,Dia -150 mm, Pumping Hours-12.50 Hours,Altitude of installation above MSL -1200 Meter ,Characterstics of water - Clear Cold Water ,Temperature - 25 degree centigrade BI01010001010000000000000515BI0100001654 1 Set
542 173.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001655 1 Set
543 173.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001656 1 No.
544 173.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001657 1 No.
545 173.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001658 1 No.
546 173.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001659 1 No.
547 173.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001660 1 No.
548 173.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001661 1 No.
549 173.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001662 1 No.
550 173.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001663 1 set
551 173.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001664 1 set
552 173.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001665 1 set
553 173.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001666 1 set
554 173.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001667 1 Nos
555 173.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001668 1 Nos
556 173.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001669 1 Nos
557 173.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001670 1 Nos
558 173.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001671 1 Nos
559 173.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001672 1 Nos
560 173.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001673 1 Nos
561 173.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001674 1 No.
562 173.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001675 1 No.
563 173.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001676 1 No.
564 173.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001677 1 Job
565 173.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n BI01010001010000000000000515BI0100001678 10 Rmt.
566 173.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001679 6 Rmt.
567 173.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001680 10 Rmt.
568 173.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001681 10 Rmt.
569 173.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001682 10 Rmt.
570 173.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001683 1 Job
571 174 (CENTRIFUGAL STAGE) LWSS Kathwari 1st StageProviding & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:Discharge(Q) -4.28 LPS for each pump,Total Dynamic heads:- 493.34 Meter,LWL in sump well(h) 793.00 Meter ,Shaft Level -792.00 Meter,Level at Discharge point -1252.00 Meter, Suction Lift -'+ve, Discharge-Head-459.00 Meter,Static head 459.00 Meter,Rising Main Length -1490 Meter,Dia-80 mm,Pumping Hours -7.00 Hours ,Altitude of installation above MSL - 800 Meter , Characterstics of water , Temperature-25 degree centigrade. BI01010001010000000000000515BI0100001684 1 Set
572 174.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001685 1 Set
573 174.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001686 1 No.
574 174.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001687 1 No.
575 174.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001688 1 No.
576 174.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001689 1 No.
577 174.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001690 1 No.
578 174.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001691 1 No.
579 174.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001692 1 No.
580 174.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001693 1 set
581 174.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001694 1 set
582 174.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001695 1 set
583 174.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001696 1 set
584 174.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001697 1 Nos
585 174.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001698 1 Nos
586 174.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001699 1 Nos
587 174.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001700 1 Nos
588 174.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001701 1 Nos
589 174.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001702 1 Nos
590 174.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001703 1 Nos
591 174.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001704 1 No.
592 174.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001705 1 No.
593 174.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001706 1 No.
594 174.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001707 1 Job
595 174.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe BI01010001010000000000000515BI0100001708 10 Rmt.
596 174.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001709 6 Rmt.
597 174.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001710 10 Rmt.
598 174.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001711 10 Rmt.
599 174.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001712 10 Rmt.
600 174.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001713 1 Job
601 175 (CENTRIFUGAL STAGE) LWSS Kathwari 2nd StageProviding & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:Discharge(Q)-5.45 LPS for each pump,Total Dynamic heads:-398.80 Meter,LWL in sump well(h) -1261.00 Meter,Shaft Level - 1260.00 Meter,Level at Discharge point -1620.00 Meter, Suction Lift -'+ve ,Discharge Head -360.00 Meter,Static head -360.00 Meter,Rising Main- Length -1150 Meter,Dia - 80 mm,Pumping Hours -5.50 Hours,Pumping Hours -5.50 Hours, Altitude of installation above MSL- 1200 Meter ,Characterstics of water- Clear Cold Water ,Temperature -25 degree centigrade BI01010001010000000000000515BI0100001714 1 Set
602 175.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001715 1 Set
603 175.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001716 1 No.
604 175.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001717 1 No.
605 175.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001718 1 No.
606 175.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001719 1 No.
607 175.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001720 1 No.
608 175.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001721 1 No.
609 175.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001722 1 No.
610 175.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001723 1 set
611 175.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001724 1 set
612 175.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001725 1 set
613 175.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001726 1 set
614 175.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001727 1 Nos
615 175.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001728 1 Nos
616 175.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001729 1 Nos
617 175.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001730 1 Nos
618 175.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001731 1 Nos
619 175.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001732 1 Nos
620 175.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001733 1 Nos
621 175.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001734 1 No.
622 175.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001735 1 No.
623 175.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001736 1 No.
624 175.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001737 1 Job
625 175.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe BI01010001010000000000000515BI0100001738 10 Rmt.
626 175.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001739 6 Rmt.
627 175.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001740 10 Rmt.
628 175.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001741 10 Rmt.
629 175.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001742 10 Rmt.
630 175.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001743 1 Job
631 176 (CENTRIFUGAL STAGE) LWSS SadohProviding & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:Discharge(Q) 3.82 LPS for each pump,Total Dynamic heads:- 306.00 Meter,LWL in sump well(h)- 1016.00 Meter , Shaft Level -1015.00 Meter,Level at Discharge point - 1305.00 Meter, Suction Lift - '+ve, Discharge Head -290.00 Meter,Static head- 290.00 Meter,Rising Main Length -840 Meter,Dia - 80 mm,Pumping Hours - 15.00 Hours,Altitude of installation above MSL -1000 Meter ,Characterstics of water -Clear Cold Water , Temperature -25 degree centigrade , BI01010001010000000000000515BI0100001744 1 Set
632 176.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001745 1 Set
633 176.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001746 1 No.
634 176.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001747 1 No.
635 176.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001748 1 No.
636 176.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001749 1 No.
637 176.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001750 1 No.
638 176.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001751 1 No.
639 176.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001752 1 No.
640 176.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001753 1 set
641 176.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001754 1 set
642 176.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001755 1 set
643 176.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001756 1 set
644 176.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001757 1 Nos
645 176.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001758 1 Nos
646 176.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001759 1 Nos
647 176.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001760 1 Nos
648 176.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001761 1 Nos
649 176.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001762 1 Nos
650 176.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001763 1 Nos
651 176.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001764 1 No.
652 176.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001765 1 No.
653 176.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001766 1 No.
654 176.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001767 1 Job
655 176.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n BI01010001010000000000000515BI0100001768 10 Rmt.
656 176.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001769 6 Rmt.
657 176.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001770 10 Rmt.
658 176.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001771 10 Rmt.
659 176.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001772 10 Rmt.
660 176.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001773 1 Job
661 177 (CENTRIFUGAL STAGE) LWSS Sadoh Tarnoh 1st StageProviding & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:Discharge(Q)-4.56 LPS for each pump,Total Dynamic heads:- 407.77 Meter,LWL in sump well(h) -728.00 Meter ,Shaft Level-727.00 Meter,Level at Discharge point 1120.00 Meter, Suction Lift - '+ve , Discharge Head -393.00 Meter,Static head - 393.00 Meter, Rising Main Length -1650 Meter,Dia -100 mm,Pumping Hours -8.00 Hours,Altitude of installation above MSL -750 Meter ,Characterstics of water -Clear Cold Water ,Temperature 25 degree centigrade, BI01010001010000000000000515BI0100001774 1 Set
662 177.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001775 1 Set
663 177.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001776 1 No.
664 177.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001777 1 No.
665 177.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001778 1 No.
666 177.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001779 1 No.
667 177.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001780 1 No.
668 177.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001781 1 No.
669 177.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001782 1 No.
670 177.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001783 1 set
671 177.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001784 1 set
672 177.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001785 1 set
673 177.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001786 1 set
674 177.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001787 1 Nos
675 177.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001788 1 Nos
676 177.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001789 1 Nos
677 177.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001790 1 Nos
678 177.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001791 1 Nos
679 177.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001792 1 Nos
680 177.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001793 1 Nos
681 177.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001794 1 No.
682 177.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001795 1 No.
683 177.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001796 1 No.
684 177.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001797 1 Job
685 177.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:a) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n\n BI01010001010000000000000515BI0100001798 10 Rmt.
686 177.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001799 6 Rmt.
687 177.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001800 10 Rmt.
688 177.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001801 10 Rmt.
689 177.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001802 10 Rmt.
690 177.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001803 1 Job
691 178 (CENTRIFUGAL STAGE) LWSS Sadoh Tarnoh 2nd StageProviding & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:(Discharge(Q)- 4.57 LPS for each pump , Total Dynamic heads:- 440.08 Meter,LWL in sump well(h) -1120.00 Meter, Shaft Level - 1118.00 Meter,Level at Discharge point - 1548.00 Meter, Suction Lift -'+ve ,Discharge - 430.00 Meter, Static head- 430.00 Meter,Rising Main-Length -1162 Meter,Dia-100 mm,Pumping Hours -6.00 Hours,Altitude of installation above MSL -1100 Meter, Characterstics of water -Clear Cold Water ,Temperature- 25 degree centigrade) BI01010001010000000000000515BI0100001804 1 Set
692 178.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001805 1 Set
693 178.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001806 1 No.
694 178.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001807 1 No.
695 178.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001808 1 No.
696 178.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001809 1 No.
697 178.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001810 1 No.
698 178.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001811 1 No.
699 178.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001812 1 No.
700 178.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001813 1 set
701 178.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001814 1 set
702 178.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001815 1 set
703 178.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001816 1 set
704 178.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001817 1 Nos
705 178.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001818 1 Nos
706 178.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001819 1 Nos
707 178.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001820 1 Nos
708 178.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001821 1 Nos
709 178.18 Providing double flanged cast steel sluice valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001822 1 Nos
710 178.19 Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001823 1 Nos
711 178.2 Providing double flanged cast steel reflux valves class, ASA-300 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001824 1 No.
712 178.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001825 1 No.
713 178.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001826 1 No.
714 178.23 Installation of all the items apparing as per the syatematic drawing. BI01010001010000000000000515BI0100001827 1 Job
715 178.24 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:a) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n\n BI01010001010000000000000515BI0100001828 10 Rmt.
716 178.25 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001829 6 Rmt.
717 178.26 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001830 10 Rmt.
718 178.27 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001831 10 Rmt.
719 178.28 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001832 10 Rmt.
720 178.29 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001833 1 Job
721 179 Providing, laying and jointing, testing in trenches galvanised mild steel tubes (Light Class) screwed and socketed, ISI marked, conformining to IS :1239 & latest with upto date ammendments including tube fitting such as bends, tees, air valves, unions and collars etc. as per direction and to the entire satisfaction of the Engineer-in-charge (Earth work in trenches to be measured and paid for separately) in all leads and lifts.80 mm Diameter BI01010001010000000000000515BI0100001834 2850 Rmt
722 179.01 65 mm Diameter BI01010001010000000000000515BI0100001835 4550 Rmt
723 179.02 50 mm Diameter BI01010001010000000000000515BI0100001836 1450 Rmt
724 179.03 32 mm Diameter BI01010001010000000000000515BI0100001837 6725 Rmt
725 179.04 25 mm Diameter BI01010001010000000000000515BI0100001838 4400 Rmt
726 179.05 20 mm Diameter BI01010001010000000000000515BI0100001839 2385 Rmt
727 179.06 15 mm Diameter BI01010001010000000000000515BI0100001840 100 Rmt
728 180 Providing FHTC to the Balance Households in GP Baggi Tungal, Sai, Nichla lot, Kasan, Kot, Kotli and sehli Tehsil Sadar Distt. Mandi (HP)Excavation in foundations trenches etc. ( for pipes and pits ) upto all depths in all kinds of soil such as pick work, jumper work, blasting and chiselling soft/hard rocks where blasting is prohibited in all leads and lifts including trimming and dressing of sides levelling of bed to correct excavation and returning the stacked soil after laying jointing and testing of G.I.Pipes in trenches in 15 cm. layers including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting/timbering and dewatering where ever required including restoration of un-metalled/metalled paved surface of its original conditions including cost of diversion for traffic night signals Fixing caution boards and fencing etc.complete in all respects. BI01010001010000000000000515BI0100001841 10341.7 Cum
729 181 Providing, laying and jointing, testing in trenches galvanised mild steel tubes (Light Class) screwed and socketed, ISI marked, conformining to IS :1239 & latest with upto date ammendments including tube fitting such as bends, tees, air valves, unions and collars etc. as per direction and to the entire satisfaction of the Engineer-in-charge (Earth work in trenches to be measured and paid for separately) in all leads and lifts.65 mm Diameter BI01010001010000000000000515BI0100001842 1815 Rmt
730 181.01 50 mm Diameter BI01010001010000000000000515BI0100001843 7830 Rmt
731 181.02 40 mm Diameter BI01010001010000000000000515BI0100001844 7460 Rmt
732 181.03 32 mm Diameter BI01010001010000000000000515BI0100001845 5460 Rmt
733 181.04 25 mm Diameter BI01010001010000000000000515BI0100001846 9735 Rmt
734 181.05 20 mm Diameter BI01010001010000000000000515BI0100001847 13095 Rmt
735 181.06 15 mm Diameter BI01010001010000000000000515BI0100001848 5325 Rmt
736 182 Providing and Fixing Brass Stop Cock, Wheel Valve including housing chamber complete in all leads and lifts.65 mm Diameter BI01010001010000000000000515BI0100001849 1 Nos.
737 182.01 50 mm Diameter BI01010001010000000000000515BI0100001850 4 Nos.
738 182.02 40 mm Diameter BI01010001010000000000000515BI0100001851 8 Nos.
739 182.03 32 mm Diameter BI01010001010000000000000515BI0100001852 5 Nos.
740 182.04 25 mm Diameter BI01010001010000000000000515BI0100001853 8 Nos.
741 182.05 20 mm Diameter BI01010001010000000000000515BI0100001854 14 Nos.
742 182.06 15 mm Diameter BI01010001010000000000000515BI0100001855 17 Nos.
743 183 Providing FHTC to the Balance Households of various villages of GP Bizan, Tung and Nasloh Tehsil Sadar Distt Mandi (HP)Excavation in foundations trenches etc. ( for pipes and pits ) upto all depths in all kinds of soil such as pick work, jumper work, blasting and chiselling soft/hard rocks where blasting is prohibited in all leads and lifts including trimming and dressing of sides levelling of bed to correct excavation and returning the stacked soil after laying jointing and testing of G.I.Pipes in trenches in 15 cm. layers including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting/timbering and dewatering where ever required including restoration of un-metalled/metalled paved surface of its original conditions including cost of diversion for traffic night signals Fixing caution boards and fencing etc.complete in all respects. BI01010001010000000000000515BI0100001856 15890.1 Cum
744 184 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 crushed stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads & lifts. BI01010001010000000000000515BI0100001857 6.09 Cum
745 185 Providing form work with steel plates 3.15 mm thick welded with angle iron in frames 30x30x5 mm, so as to give a fair finish including centering ,shuttering, propping etc.with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in:-Vertical surface such as walls(any thickness) partitions and the like including attached pillasters, butteresses, plinth and string courses and the like in all leads & lifts. BI01010001010000000000000515BI0100001858 122.52 Sqm
746 185.01 Flat surfaces such as soffits of suspended floors, roofs landings and the like: floors etc. up to 200 mm in thickness in all leads & lifts. BI01010001010000000000000515BI0100001859 26.43 Sqm
747 186 Providing and laying cement concrete 1:11/2 :3 ( 1cement : 1 1/2 sand: 3 crushed stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Foundation footings bases of columns and the like and mass concrete in all leads and lifts. BI01010001010000000000000515BI0100001860 4.2 Cum
748 186.01 Walls (any thickness but not less than 0.1 mtr thickness) attached pilasters, buttresses, plinth and string courses etc. from top of foundation level up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001861 9.18 Cum
749 187 Providing and laying cement concrete 1:2:4 ( 1 cement : 2 sand : 4 crushed stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001862 3.09 Cum
750 188 Providing and laying Tor Steel reinforcement for reinforcement cement concrete work including bending, binding and placing in position includig the cost of binding wire and cutting in all leads and lifts as per the directions of the Enginerer-in-Charge. BI01010001010000000000000515BI0100001863 1482.3 Kg
751 189 Providing and Fixing of Steel/fibre reinforcement concrete (SFRC) manhole cover with frame conforming to IS-12592 (Part - I)-1998 with latest ammendments 560 mm dia medium duty in all leads and lifts. BI01010001010000000000000515BI0100001864 3 Nos.
752 190 Providing and Fixing of MS Fabricated Protection Panel 750 mm x 750 mm made with MS Angle 40 x 40 x 4 mm for frame, MS Angle 30 x 30 x 3 mm for cover, MS Flat 25 x 5 mm for Fixing of sliding door bolt and MS Sheet 4.00 mm thick for protection of manhole covers of storage tanks including the cost of cutting and welding of MS angle, MS Flat & MS Sheet, embedding in RCC Slab by drilling holes in MS angle & in RCC slab, provision for providing and Fixing sliding door bolt 300 x 16 mm, MS Handle 100 mm, Lock and applying a coat of red lead paint & painting two coat with steel paint (Firoza Blue) complete job in all respect in all leads and lifts and to the entire satisfaction of the Engineer - in - Charge. BI01010001010000000000000515BI0100001865 3 Nos.
753 191 1.20 metre heigh fencing (as per approved design) 1.80 metres R.C.C.posts 3 metres centre to centre and R.C.C. struts with 7 horizental lines and two diagonals of galvanised steel bar bed wire (IS 278-1962 type I) weighing 9.38 kg./100 metres (minimum) strained and fixed to posts by typing to 6mm galvanised steel bar niles/clips with G.I. binding wire including cost of Excavation, R.C.C. Posts,R.C.C. struts and straining belts and embeded in cement concrete 1:4:8 ( 1cement : 4 sand : 8 graded stone aggregate 40 mm nominal size) and curing complete in all respect with manufacturing & Fixing of MS Gate 1.20X1.50 Meter and to the entire satisfaction of the Engineer-in-Charge. BI01010001010000000000000515BI0100001866 54.21 Rmt
754 192 Providing, laying and jointing, testing in trenches galvanised mild steel tubes (Light Class) screwed and socketed, ISI marked, conformining to IS :1239 & latest with upto date ammendments including tube fitting such as bends, tees, air valves, unions and collars etc. as per direction and to the entire satisfaction of the Engineer-in-charge (Earth work in trenches to be measured and paid for separately) in all leads and lifts.100 mm Diameter BI01010001010000000000000515BI0100001867 1600 Rmt
755 192.01 80 mm Diameter BI01010001010000000000000515BI0100001868 800 Rmt
756 192.02 65 mm Diameter BI01010001010000000000000515BI0100001869 2150 Rmt
757 192.03 50 mm Diameter BI01010001010000000000000515BI0100001870 2950 Rmt
758 192.04 40 mm Diameter BI01010001010000000000000515BI0100001871 5850 Rmt
759 192.05 32 mm Diameter BI01010001010000000000000515BI0100001872 10760 Rmt
760 192.06 25 mm Diameter BI01010001010000000000000515BI0100001873 11450 Rmt
761 192.07 20 mm Diameter BI01010001010000000000000515BI0100001874 15520 Rmt
762 192.08 15 mm Diameter BI01010001010000000000000515BI0100001875 15070 Rmt
763 193 Providing and Fixing Brass Stop Cock, Wheel Valve including housing chamber complete in all leads and lifts 100 mm Diameter. BI01010001010000000000000515BI0100001876 1 No.
764 193.01 80 mm Diameter BI01010001010000000000000515BI0100001877 1 No.
765 193.02 65 mm Diameter BI01010001010000000000000515BI0100001878 3 Nos.
766 193.03 50 mm Diameter BI01010001010000000000000515BI0100001879 4 Nos.
767 193.04 40 mm Diameter BI01010001010000000000000515BI0100001880 7 Nos.
768 193.05 32 mm Diameter BI01010001010000000000000515BI0100001881 12 Nos.
769 193.06 25 mm Diameter BI01010001010000000000000515BI0100001882 11 Nos.
770 193.07 20 mm Diameter BI01010001010000000000000515BI0100001883 13 Nos.
771 193.08 15 mm Diameter BI01010001010000000000000515BI0100001884 13 Nos.
772 194 Providing FHTC to the Balance Households of various villages in GP Dudar Bharoun, Majhwar, Dhar, Pandoh, Seyogi and Jagar Tehsil Sadar Distt Mandi (HP)Transportation of suitable truck mounted DTH and ODEX/Percussion Calyx/RC drilling rigs alongwith necessary accessories etc to the site of work and errection of rig including levelling etc. complete in all respects as per the directions of the Engineer-in-Charge in all leads and lifts. BI01010001010000000000000515BI0100001885 2 Nos.
773 195 Drilling bores of 200 mm dia as per IS 2800-1979 from ground level in the overburden as per direction of the Engineer-in-Charge/hydrogeologist with suitable rigs for drilling through rocky formation consisting of sand stone, limestone, dolomites, congiomerate, boulder pebble, gravats, silt, clay or any other type of sedimentary, metamorphic and igneous rocks including cost of attachements consumables stores bils, water, POL etc complete in all respect in all leads and lifts. BI01010001010000000000000515BI0100001886 100 Rmt.
774 196 Supplying and lowering IS marked 200 mm ERW plain casing pipe as per IS 4270-2001 with upto date amendments in a length of 3 metres including cost of cutting welding, transportation charges complete in all respect. The pipe shall be at suitable intervals as per direction of Engineer-in-Charge in all leads and lifts. BI01010001010000000000000515BI0100001887 100 Rmt.
775 197 Providing and fixing suitable casing shoe and bit tube as per requirement of ODEX attachment complete in all respects as per directions of the Engineer-in-Charge in all leads and lifts. BI01010001010000000000000515BI0100001888 2 Nos.
776 198 Collection and preservation of soil samples in polythene bags complete in all respects as per the directions of the Engineer-in-Charge in all leads and lifts. BI01010001010000000000000515BI0100001889 2 Nos
777 199 Development of bore well and yield testing with air compressor through V notch and disinfection etc. complete in all respects as per IS-2800-1979 and as per directions of the Engineer-in-Charge in all leads and lifts. BI01010001010000000000000515BI0100001890 2 Hours
778 200 Excavation in foundations trenches etc. ( for pipes and pits ) upto all depths in all kinds of soil such as pick work, jumper work, blasting and chiselling soft/hard rocks where blasting is prohibited in all leads and lifts including trimming and dressing of sides levelling of bed to correct excavation and returning the stacked soil after laying jointing and testing of G.I.Pipes in trenches in 15 cm. layers including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting/timbering and dewatering where ever required including restoration of un-metalled/metalled paved surface of its original conditions including cost of diversion for traffic night signals Fixing caution boards and fencing etc.complete in all respects. BI01010001010000000000000515BI0100001891 10876.9 Cum
779 201 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 crushed stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads & lifts. BI01010001010000000000000515BI0100001892 2.03 Cum
780 202 Providing form work with steel plates 3.15 mm thick welded with angle iron in frames 30x30x5 mm, so as to give a fair finish including centering ,shuttering, propping etc.with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in:-Vertical surface such as walls(any thickness) partitions and the like including attached pillasters, butteresses, plinth and string courses and the like in all leads & lifts. BI01010001010000000000000515BI0100001893 40.84 Sqm
781 202.01 Flat surfaces such as soffits of suspended floors, roofs landings and the like: floors etc. up to 200 mm in thickness in all leads & lifts. BI01010001010000000000000515BI0100001894 8.81 Sqm
782 203 Providing and laying cement concrete 1:11/2 :3 ( 1cement : 1 1/2 sand: 3 crushed stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Foundation footings bases of columns and the like and mass concrete in all leads and lifts. BI01010001010000000000000515BI0100001895 1.4 Cum
783 203.01 Walls (any thickness but not less than 0.1 mtr thickness) attached pilasters, buttresses, plinth and string courses etc. from top of foundation level up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001896 3.06 Cum
784 204 Providing and laying cement concrete 1:2:4 ( 1 cement : 2 sand : 4 crushed stone aggregate 20 mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-Suspended floors, roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level in all leads & lifts. BI01010001010000000000000515BI0100001897 1.03 Cum
785 205 Providing and laying Tor Steel reinforcement for reinforcement cement concrete work including bending, binding and placing in position includig the cost of binding wire and cutting in all leads and lifts as per the directions of the Enginerer-in-Charge. BI01010001010000000000000515BI0100001898 494.1 Kg
786 206 Providing and Fixing of Steel/fibre reinforcement concrete (SFRC) manhole cover with frame conforming to IS-12592 (Part - I)-1998 with latest ammendments 560 mm dia medium duty in all leads and lifts. BI01010001010000000000000515BI0100001899 1 Nos.
787 207 Providing and Fixing of MS Fabricated Protection Panel 750 mm x 750 mm made with MS Angle 40 x 40 x 4 mm for frame, MS Angle 30 x 30 x 3 mm for cover, MS Flat 25 x 5 mm for Fixing of sliding door bolt and MS Sheet 4.00 mm thick for protection of manhole covers of storage tanks including the cost of cutting and welding of MS angle, MS Flat & MS Sheet, embedding in RCC Slab by drilling holes in MS angle & in RCC slab, provision for providing and Fixing sliding door bolt 300 x 16 mm, MS Handle 100 mm, Lock and applying a coat of red lead paint & painting two coat with steel paint (Firoza Blue) complete job in all respect in all leads and lifts and to the entire satisfaction of the Engineer - in - Charge. BI01010001010000000000000515BI0100001900 1 Nos.
788 208 1.20 metre heigh fencing (as per approved design) 1.80 metres R.C.C.posts 3 metres centre to centre and R.C.C. struts with 7 horizental lines and two diagonals of galvanised steel bar bed wire (IS 278-1962 type I) weighing 9.38 kg./100 metres (minimum) strained and fixed to posts by typing to 6mm galvanised steel bar niles/clips with G.I. binding wire including cost of Excavation, R.C.C. Posts,R.C.C. struts and straining belts and embeded in cement concrete 1:4:8 ( 1cement : 4 sand : 8 graded stone aggregate 40 mm nominal size) and curing complete in all respect with manufacturing & Fixing of MS Gate 1.20X1.50 Meter and to the entire satisfaction of the Engineer-in-Charge. BI01010001010000000000000515BI0100001901 18.07 Rmt
789 209 Providing, laying and jointing, testing in trenches galvanised mild steel tubes (Light Class) screwed and socketed, ISI marked, conformining to IS :1239 & latest with upto date ammendments including tube fitting such as bends, tees, air valves, unions and collars etc. as per direction and to the entire satisfaction of the Engineer-in-charge (Earth work in trenches to be measured and paid for separately) in all leads and lifts.65 mm Diameter BI01010001010000000000000515BI0100001902 32540 Rmt
790 209.01 50 mm Diameter BI01010001010000000000000515BI0100001903 24945 Rmt
791 209.02 40 mm Diameter BI01010001010000000000000515BI0100001904 4200 Rmt
792 209.03 32 mm Diameter BI01010001010000000000000515BI0100001905 2800 Rmt
793 209.04 25 mm Diameter BI01010001010000000000000515BI0100001906 7650 Rmt
794 210 Providing and Fixing Brass Stop Cock, Wheel Valve including housing chamber complete in all leads and lifts.65 mm Diameter BI01010001010000000000000515BI0100001907 15 Nos.
795 210.01 50 mm Diameter BI01010001010000000000000515BI0100001908 12 Nos.
796 210.02 40 mm Diameter BI01010001010000000000000515BI0100001909 3 Nos.
797 210.03 32 mm Diameter BI01010001010000000000000515BI0100001910 3 Nos.
798 210.04 25 mm Diameter BI01010001010000000000000515BI0100001911 6 Nos.
799 211 Providing LWSS to PC Habitation in Census Village DPF Sarain, Kanoj & Ropain GP Chaihtigarh Tehsil Aut Distt Mandi HP.Excavation in foundations trenches etc. ( for pipes and pits ) upto all depths in all kinds of soil such as pick work, jumper work, blasting and chiselling soft/hard rocks where blasting is prohibited in all leads and lifts including trimming and dressing of sides levelling of bed to correct excavation and returning the stacked soil after laying jointing and testing of G.I.Pipes in trenches in 15 cm. layers including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting/timbering and dewatering where ever required including restoration of un-metalled/metalled paved surface of its original conditions including cost of diversion for traffic night signals Fixing caution boards and fencing etc.complete in all respects. BI01010001010000000000000515BI0100001912 1006.2 Cum
800 212 Pumping Machinery:- Raw Water Stage :- Supply of submersible pumping set of KSB/Calama/SU/ johnson and other approved make comprising to latest relevant BIS Code. The pump should be fitted with bronze impller of suitable alloys as per BIS 5659-1972 latest suitable for having greased packed bearing and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersibed squirrei cage electric induction motor (water proof type) of required HP RPM 2900 of Kirloskar /NGEF/ Cromption and other approved make make conformining to BIS 9287-1979 latest with upto date amendmednts totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty point head with 60% efficiency. It should also be fitted with a device to take up expansion of water with heating of motor:-Discharge (Q) -3.08 LPS for each pump,Total Dynamic heads:- 64.61 Meter, LWL in sump well(h) - 1264.60 Meter, Shaft Level -1267.00 Meter,Level at Discharge point -1323.00 Meter, Suction Lift - '+ve, Discharge Head -56.00 Meter,Static head -56.00 Meter, Rising Main Length -60 Meter, Dia- 65 mm,Pumping Hours - 4 Hours,Altitude of installation above MSL -1000 Meter , Characterstics of water -Clear Water with turbidity up to 50 PPM,Temperature- 20 degree centigrade ) BI01010001010000000000000515BI0100001913 2 Sets
801 212.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001914 1 Set
802 212.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001915 1 No.
803 212.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001916 1 No.
804 212.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001917 1 No.
805 212.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001918 1 No.
806 212.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001919 1 No.
807 212.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001920 1 No.
808 212.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001921 1 No.
809 212.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001922 1 set
810 212.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001923 2 set
811 212.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001924 2 set
812 212.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001925 2 set
813 212.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001926 2 Nos
814 212.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001927 2 Nos
815 212.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001928 2 Nos
816 212.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001929 2 Nos
817 212.17 Providing double flanged cast steel sluice valve, PN 1.00 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001930 1 No
818 212.18 Providing double flanged swing type cast steel valve, PN 1.00 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001931 1 No
819 212.19 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001932 1 No.
820 212.2 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001933 1 No.
821 212.21 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:a) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe\n\n BI01010001010000000000000515BI0100001934 10 Rmt.
822 212.22 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001935 10 Rmt.
823 212.23 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001936 5 Rmt.
824 212.24 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001937 10 Rmt.
825 212.25 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001938 10 Rmt.
826 212.26 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001939 1 Job
827 213 First Stage :- Providing & Installing horizontal spindle,horizontal/redial split casing/end suction (Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti and other approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and other approved make suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head with 60% efficiency. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts, bolts and painting etc. and should meet the following requirements:Discharge(Q) - 3.08 LPS for each pump,Total Dynamic heads:- 555.63 Meter,LWL in sump well(h) -1320.00 Meter,Shaft Level - 1320.60 Meter, Level at Discharge point - 1820.00 Meter, Suction Lift - '-ve ,Discharge Head-499.40 Meter ,Static head - 499.40 Meter, Rising Main Length -1720 Meter,Dia - 65 mm, Pumping Hours -16 Hours,Altitude of installation above MSL -1000 Meter , Characterstics of water- Clear Water with turbidity up to 50 PPM,Temperature - 20 degree centigrade BI01010001010000000000000515BI0100001940 2 Sets
828 213.01 Providing ICTP main switch with HRC fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. BI01010001010000000000000515BI0100001941 1 Set
829 213.02 Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities\n BI01010001010000000000000515BI0100001942 1 No.
830 213.03 a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments\n BI01010001010000000000000515BI0100001943 1 No.
831 213.04 b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.\n BI01010001010000000000000515BI0100001944 1 No.
832 213.05 c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition)\n BI01010001010000000000000515BI0100001945 1 No.
833 213.06 d) Digital 100 mm diameter circular dial A.C.supply voltmeter of recommended make AE/IMP/Havells of suitable range with selector switches as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001946 1 No.
834 213.07 e) Digital Power factor meter of standard make AE/L&T/IMP/Havells as per relevant IS code with upto dateammendments\n BI01010001010000000000000515BI0100001947 1 No.
835 213.08 f) Digital Frequencey meter of standard makeAE/L&T/IMP/Havells as per relvant IS code with uptodate ammendments\n BI01010001010000000000000515BI0100001948 1 No.
836 213.09 g) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments\n BI01010001010000000000000515BI0100001949 1 set
837 213.1 h) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001950 2 set
838 213.11 i) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments\n BI01010001010000000000000515BI0100001951 2 set
839 213.12 j) Digital 100mm dia circular dial A.C.supply flush ammeter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments\n BI01010001010000000000000515BI0100001952 2 set
840 213.13 k) Capacitor of Mechneil/ BHEL/GEC make as per 15:2834:1986 with upto date ammendments , to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rting according to H.P.offered including cables as per relevant ISI code (of siemens/clocter.IEC make )from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per Is:4064:1978 with upto date ammendments\n BI01010001010000000000000515BI0100001953 2 Nos
841 213.14 l) Providing suitable oil immersed starter delta/direct on line/auto transformer/. starter rotor starter of MEI/.Kilburn/Jyoti /L&T/Siemens make as per IS:8544:1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type over-load release and dashpot, time lag, under voltage release with or without initial oil filling as the case may be with single phae preventor as per IS:1248( P-V) 1983 with upto date ammendments\n BI01010001010000000000000515BI0100001954 2 Nos
842 213.15 m) Providng Digital hour run meter of recommended make and suitable capacity as per IS:722(latest edition.)\n BI01010001010000000000000515BI0100001955 2 Nos
843 213.16 n) Providng antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS:6337:1971. BI01010001010000000000000515BI0100001956 2 Nos
844 213.17 Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)\n BI01010001010000000000000515BI0100001957 2 Nos
845 213.18 Providing double flanged cast steel sluice valve, ASA-600 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001958 2 Nos
846 213.19 Providing double flanged swing type cast steel valve, ASA-600 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001959 2 Nos
847 213.2 Providing double flanged cast steel reflux valves class, ASA-600 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make and of 65 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)\n BI01010001010000000000000515BI0100001960 1 No.
848 213.21 Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments.\n BI01010001010000000000000515BI0100001961 1 No.
849 213.22 Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments\n BI01010001010000000000000515BI0100001962 1 No.
850 213.23 Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under:\na) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5 M/second in the suction pipe\n BI01010001010000000000000515BI0100001963 10 Rmt.
851 213.24 b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe\n BI01010001010000000000000515BI0100001964 10 Rmt.
852 213.25 c) Common header : One dia higher then delivery of pump x 65 mm dia and will extend upto 5 meters from the outer wall of the pump house in the direction to be jointed.\n BI01010001010000000000000515BI0100001965 5 Rmt.
853 213.26 Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.\n(a) Motor side (From switch to starter and starter to motor) BI01010001010000000000000515BI0100001966 10 Rmt.
854 213.27 (b) Supply side (From Meter of HPSEB to bus bar and switch) BI01010001010000000000000515BI0100001967 10 Rmt.
855 213.28 Providing and fixing double loop earthing with copper plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. BI01010001010000000000000515BI0100001968 1 Job
856 214 Providing , laying, fixing, jointing and testing in trenches MS pipe of following dia meters confirming to confirming to BIS 3183-2007, of following grade and having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).First Stage :-65 mm diameter MS Pipe (L-290 or X-42) 4.00 mm thickness with Flange Table-34 BI01010001010000000000000515BI0100001969 40 Rmt
857 215 Providing , laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of MS pipe of following dia meters confirming to BIS 3183-2007, steel grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).First Stage :-65 mm diameter MS Pipe (L-290 or X-42) 4.00 mm thickness BI01010001010000000000000515BI0100001970 760 Rmt
858 216 Providing, laying, jointiong and testing in trenches GMS pipe of following dia meters confirming to BIS: 1239 (Part-i),of following grade having wall thickness as specified below with plain end and capable of with standing required test pressure in random length of 4 to 7 meters, including special, short pieces , beds reducers, tees etc. made from parent tube providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392 - 1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3 mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing , providing and fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge . The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipe shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carrage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts (Earth work in trenches will be measured and paid for sepa rately)Booster Stage :-65 mm dia-GMS pipe 3.60 mm thickness with Flange Table-17 (Medium Class) BI01010001010000000000000515BI0100001971 60 Rmt.
859 216.01 First Stage :-65 mm dia-GMS pipe 3.60 mm thickness with Flange Table-28 (Medium Class) BI01010001010000000000000515BI0100001972 46 Rmt.
860 217 Providing, laying, jointiong and testing (by way of circumfrential butt welded joints by electrical arc welding) and testing of GMS pipe of following dia meters confirming to BIS: 1239 (Part-i) grade specified below (latest withup to date amendments ) having wall thickness as specified below with bevelled ends and capable of with standing required test pressure in random length of 4 to 7 meters, including manufacturing reducers tapers , all short pieces, beds etc. as per site requirement made from parent tubes. The laying of pipe will include all operation such as cutting, welding , jointing , fabrication of bends , tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge . The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipe shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carrage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts (Earth work in trenches will be measured and paid for separately)First Stage :-65 mm dia-GMS pipe 3.60 mm thickness (Medium Class) BI01010001010000000000000515BI0100001973 874 Rmt.
Disclaimer :