Military Engineer Services-MES has published Repairs To Rr Masonry Drain Repairs To Culvert Including Coping Pointing Kerb Stone Vhequered Tiles And Interlocking Tiles And Repairs To Street Light Control Panel And Allied Works In Zone A At Arakkonam. Submission Date for this Tender is 08-07-2021. Control Panel Tenders in Arakkonam Tamil Nadu. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 25-Jun-2021 | BOQ corrigendum | BOQ | 05-07-2021 |
2 | 06-Jul-2021 | date corrigendum | Date | 08-07-2021 |
Name of Work: REPAIRS TO RR MASONRY DRAIN, REPAIRS TO CULVERT, INCLUDING COPING, POINTING, KERB STONE VHEQUERED TILES AND INTERLOCKING TILES AND REPAIRS TO STREET LIGHT CONTROL PANEL AND ALLIED WORKS IN ZONE 'A' AT ARAKKONAM (TENDER ID NO. 2021_MES_450707_1) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of cement concrete of any description and in any position not ohterwise specifically provided for and removal and rubish of premises exc 500m but not exc 1.5 km complete all as specified and as directed.\n | 1.5 | Cum | |
2 | 2 | Material and labour for providing precast cement concrete louvers and jallies, 25mm thick (measured solid) including all mouldings set in cement mortar 1:6 type B0 1:2:4 (Using 12.5 mm graded stone aggregate) complete all as specified and as directed.\n | 60 | Sqm | |
3 | 3 | Demolition of cement concrete ( unreinforced) in ground floors and paving n. exc 15 cm thick ( below & above ground level) and removal & rubish of Premises exc 250 m but n exc 500 m complete all as specified and as directed.\n | 170.5 | Cum | |
4 | 4 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc, laid dry complete all as specified and as directed.\n\n | 40 | X Sqm | |
5 | 5 | Material and labour for plain cement concrete type D-2, 1:4:8 (Using 40mm graded stone aggregates) as in sub base complete all as specified and as directed.\n | 99 | Cum | |
6 | 6 | Material and labour for M-sand filling as a cushioning/ bedding complete all as specified and as directed.\n | 77 | Cum | |
7 | 7 | Material and labour for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and no pigment complete all as specified and as directed.\n | 625 | Sqm | |
8 | 8 | All as per ser item No 07 above but except paver blocks complete all as specified and as directed.\n | 400 | Sqm | |
9 | 9 | Material and labour for chequred cement concrete tiles 300 x 300 x 20-22mm thick set, jointed and pointed in neat cement slurry over 20mm thick screed bed in CM 1:6 with coloured cement to match the shade of tiles complete all as specified and as directed.\n | 362 | Sqm | |
10 | 10 | Material and labour for cement concrete type B-0, 1:2:4 (Using 12.5 mm graded stone aggregates) for edging/coping complete all as specified and as directed.\n | 11.3 | Cum | |
11 | 11 | Demolition of brickwork or stone/ boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework complete all as specified and as directed.\n | 70.4 | Cum | |
12 | 12 | Material and labour for walling random rubble, brought upto courses well bonded, bedded and solidly hearted, built in CM 1:4 complete all as specified and as directed.\n | 50.6 | Cum | |
13 | 13 | All as per item No.12 here-in-before but except stone.\n | 11 | Cum | |
14 | 14 | Material and labour for plain cement concrete bond stones type B1 1:2:4 (using 20 mm graded stone aggregate) complete all as specified and as directed.\n | 2 | Cum | |
15 | 15 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, with maximum depression on face from straight edge held against the dressed surface n exc 40 mm, as specified, of random rubble walling, uncoursed or brought upto courses; complete all as specified and as directed.\n | 162.1 | Kg | |
16 | 16 | Material and labour for racking out joints/ pointing to random rubble or polygonal rubble uncoursed or brought up to courses built in cement mortar complete all as specified and as directed.\n | 38.1 | X Sqm | |
17 | 17 | Material and labour for flush pointing to random rubble mansonry, uncoursed or brought upto courses in CM 1:3 complete all as specified and as directed.\n | 54.3 | X Sqm | |
18 | 18 | Material and labour for old size brick work with sub class 'B' bricks straight or curved on plan exc 6m mean redius built in CM 1:4 complete all as specified and as directed.\n | 3 | Cum | |
19 | 19 | Material and labour for old size brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed.\n | 50 | Sqm | |
20 | 20 | Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement complete all as specified and as directed.\n | 25 | Sqm | |
21 | 21 | Material and labour for three coat white wash on newly plastered surfaces of wall including preparation of surface complete all as specified and as directed.\n | 25 | Sqm | |
22 | 22 | Supply and fix 75mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.\n | 30 | RM | |
23 | 23 | Material and labour for 75mm thick PCC 1:3:6 type C-1 (Using 20mm graded stone aggregate) as in plinth protection, including finished even and smooth without using extra cement complete all as specified and as directed. | 150 | Sqm | |
24 | 24 | Material and labour for preparation of old decorated surfaces of walls by by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent walls and trading oil and greasy spots and applying one coat of cement based paint white or tinted complete all as specified and as directed.\n | 125 | Sqm | |
25 | 25 | Demolition of cement concrete (reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.\n | 6 | Cum | |
26 | 26 | Material and labour for precast reinforced cement concrete 1:2:4 type B1 (Using 20mm graded stone aggregate) as in cover slab for drain set in CM 1:6 complete all as specified and as directed.\n | 6 | Cum | |
27 | 27 | Supply and fix for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.\n | 620 | Kg | |
28 | 28 | Cleaning /desilting of bed of the drains constructed in any masonry thickness n.exc 40cm including removal of vegetation, growth or bushes or bushes or small vegetation and getting out and removing the roots including disposing off excavated silt, soil vegetation, shurbs etc., to a distance n.exc 100m where directed and deposited to a level n.exc 1.5m above the starting point complete all as specified and as directed. | 54 | Cum | |
29 | 29 | Material and labour for PCC 1:2:4 type B 1 (Using 20mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed. | 9 | Cum | |
30 | 30 | Taking down cement plaster or concrete etc., including racking out joints hacking for key scrubbing down with water etc., complete all as specified and as directed.\nNote : (i) The work shall be carried out upto six storey (G+5) buildings.\n(ii) Rate quoted is inclusive of Necessary scaffolding etc\n | 49 | Sqm | |
31 | 31 | Material and labour for 15mm thick rendering into two layers consisting 10mm thick in CM 1:4 followed by 5mm thick in CM 1:4 with WPC on fair faces of brick work or concrete surface including finished even and fair without using extra cement complete all as specified and as directed.\nNote: WPC shall be measured and paid separately.\n | 49 | Sqm | |
32 | 32 | Supply only integral water proofing compound.\n | 6 | Kg | |
33 | 33 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of cement based paint white or tinted over a coat of chalk whitening primer complete all as specified and as directed.\n | 49 | Sqm | |
34 | 34 | Taking down old unservicaeble security light junction box/bus bar box etc from existing security light poles / wall from existing positions including disconnecting existing cable connections carefully and MS clamps etc complete all as specified and directed. | 30 | Each | |
35 | 35 | Taking down old corroded MS Clamp, Cross arms, bracings, supports, back plates etc from existing street light pole of any type complete all as specified and directed. | 0.9 | Qtl | |
36 | 36 | Taking down old corroded steel conduit of any size from existing street light pole of any type /other similar locations complete all as specified and directed. | 30 | RM | |
37 | 37 | Taking down old/burnt out cable/aluminium wire from existing street light pole/bldg of any type/other similar locations complete all as specified and directed. | 1030 | RM | |
38 | 38 | Taking down old / unserviceable / burnt LED light fittings from existing positions including necessary T&P, ladder etc as per site requirement carefully, checking of fitting for defect and repair and refixing the same in existing position or any other location after repair as directed complete all as specified and directed. \nNote - 1) Spare parts as required shall be arranged by the Deptt from Fitting manufacturer aganist their warranty of fittings with Dept, However if any replacement of minor burnt wires require, the same shall be included in the rate quoted. 2) Quoted rate is deemed to be included the charges of T & P, labour etc complete as per site requirement. | 30 | Each | |
39 | 39 | Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out in soft / loose soil including removing green vegetation,roots,bushes etc from surroundings near electric poles/panels or sub stations area Complete all as specified and directed. | 50 | Sqm | |
40 | 40 | M & L for black stove enamelled rigid ERW steel conduit 20 mm dia fixing with suitable size MS clamp / saddles as per site requirement complete all as specified and directed.\nMake :- BEC/EMCO/ GARWARE /JINDAL/ WAVIN/FINOLEX. \nNote - 1) New wiring portions for replacement of unserviceable wiring as required as per site requirement shall be measured and paid separately under relevant schedule item. | 30 | RM | |
41 | 41 | Supply and fixing MCB TPN 415 V, 40- 63 Amps 'C' curve Including taking down old unserviceable one all as specified and as directed.\nMake : Legrand/ Siemens/Schneider/ABB. | 15 | Each | |
42 | 42 | Supply and fixing MCB SP 230 V, 6-32 Amps C curve Including taking down old unserviceable one all as specified and as directed.\nMake : Legrand/ Siemens/Schneider/ABB. | 15 | Each | |
43 | 43 | Supply and fixing MCB SP 230 V, 40-63 Amps C curve Including taking down old unserviceable one all as specified and as directed.\nMake : Legrand/ Siemens/Schneider/ABB. | 25 | Each | |
44 | 44 | Supply, Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 65 fabricated by CPRI certified panel manufacturer including suitable terminal TPN 10 KA SMC Connector ( for 3 Phase Cable Line IN & OUT) and provision of dimrail for mounting 3 Nos MCB SP including S&F 01 No MCB 6 A SP C curve ( Make - Siemens / Schneider/Legrand/ABB), canopy weather proof, hinged door with Two hinges, pad side locking system - 02 Nos (top and bottom), for fixing on PCC / Steel Poles including necessary MS Clamps - 02 Nos of suitable shape and size with nut, bolts and washers as per site requirement complete all as specified and directed by Engineer-in-charge. Note - 1) Drawing shall be got approved from Deptt before placing a order to CPRI certified panel manufacturers. 2) The cost deemed to be included in the quoted rate for reconnecting old existing cables to boxes carefully using a suitable glands and also taking up loop from the under ground and making good in all respect where ever required as per site requirement complete all as specified and directed. | 30 | Each Job | |
45 | 45 | Taking down unserviceable LED light fittings of any watt and type from existing position on pole/ wall/ tower/gate, complete for and including repair and refixing in existing position after repair all as specified and as directed \nNote: (i) New spare parts required for replacing old unserviceable parts shall be measured and paid separately as ‘ Supply only’ under relavent item here-in-after\n ii) Labour cost for replacing spare parts,removing unserviceable parts, dismantling light fitting and refixing including necessary T&P are deemed to be included in the quoted rate. | 163 | Each | |
46 | 46 | Supply only drivers suitable for outdoor type LED fitting any type and following wattage for flood lights/post top latern lights/street light/security lights including necessary connecting arrangements as per site requirement all as specified and directed Make : Philips/Wipro/Surya/Crompton | |||
47 | 46.01 | Out door type drivers suitable for 25 watts LED lights | 30 | Each | |
48 | 46.02 | Out door type drivers suitable for 40 watts LED lights | 10 | Each | |
49 | 46.03 | Out door type drivers suitable for 45 watts LED lights. | 48 | Each | |
50 | 46.04 | Out door type drivers suitable for 75 watts LED lights | 1 | Each | |
51 | 46.05 | Out door type drivers suitable for 150 watts LED lights | 20 | Each | |
52 | 47 | Supply only surge protection devicess any type and KV for following capacity flood lights/post top latern lights/street light/security lights including necessary connecting arrangements as per site requirement all as specified and directed. \n Make : Philips/Wipro/Surya/Crompton. | |||
53 | 47.01 | Surge protection devices not less than 5 KV suitable for LED light fittings up to 75 watts. | 25 | Each | |
54 | 47.02 | (b)Surge protection devices not less than 5 KV suitable for LED light fittings 75 watts to 150 watts. | 20 | Each | |
55 | 48 | Supply,Fixing and Testing LED street light luminaire fitting of not less than 45 Watt and not less then IP 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 5 KV complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. Make : Surya Cat-SLE UL 45W IP66 LXN / Philips/Wipro. \nNote :-\n(i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants , necessary drilling,bolts/screws for fixing new one etc as per site requirement.and MS frame work if any complete as per site requirement. \n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. | 20 | Each | |
56 | 49 | Supply and draw the PVC insulated round copper flexible cable multistranded of 3 core 1.5 sqmm with necessary arrangments all as directed.\nMake : Plaza/Gloster/Nicco/Polycab. | 800 | RM | |
57 | 50 | Supply and fixing GI bracket for street light made out of 25mm dia GI pipe medium grade 1.5 mtr length bend in shape as required complete with MS flat iron clamp,nuts and bolts etc all as directed and specified including dismantling old damaged one all as specified and as directed. | 15 | Each | |
58 | 51 | Material and labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface and old corroded item all as specified and as directed. | 0.9 | Qtl | |
59 | 52 | Supply,Fixing and Testing LED flood light fitting of not less than 50W Watt, Luminaire fitting of not less then IP 65 protection comprises of Pressure die cast Aluminium housing powder coated, toughened glass,luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 10 KV including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed.\nMake : Surya Cat ref-SLE FL 50W COSMO/ Philips/Wipro/LUKER\nNote:-\n(i) Quoted rate is deemed to be included the charges of necessary Scaffolding, Ladder, tools and plants , necessary drilling,bolts/screws for fixing new one etc as per site requirement upto 10m height and MS frame work if any complete as per site requirement. \n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. | 16 | Each | |
60 | 53 | Supply,Fixing and Testing LED flood light fitting of not less than 100 Watt, Luminaire fitting not less then IP 65 protection comprises of Pressure die cast Aluminium housing powder coated, toughened glass,luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 10 KV including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed.\nMake : Surya Cat ref-SLE FL 100W IP66 LUMOS/ Philips/Wipro/LUKER\nNote:-\n(i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants , necessary drilling,bolts/screws for fixing new one etc as per site requirement.and MS frame work if any complete as per site requirement. \n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. | 8 | Each | |
61 | 54 | Cutting and Trimming of tree branches touching street / security poles or light fittings etc, to clear the tree branches around the pole and maintain a clearance of 1.50 M radius of the pole top or light fitting complete all as specified and as directed by Engineer-in-charge. Note: (a) An area of 1.5 M surrounding the pole to be cleared off trees branches. (b) Measurement and payment will be made for all cutting / trimming near top of the each pole as one job only. | 25 | Each Job | |
62 | 55 | Supply,Fixing and Testing LED flood light fitting of not less than 150 Watt, Luminaire fitting not less then IP 65 protection comprises of Pressure die cast Aluminium housing powder coated, toughened glass, ,luminaire efficacy not less than 110 lm/w provided with Surge Suppressor 10 KV including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. \nMake : Surya Cat-SLE FL 150W IP66 LUMOS / Philips/Wipro/ LUKER \nNote:-\n(i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants , necessary drilling,bolts/screws for fixing new one etc as per site requirement.and MS frame work if any complete as per site requirement. \n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. \n | 8 | Each | |
63 | 56 | Material and labour for Earthing complete with using GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level, with top edge of the earth plate at a depth of not less than 1.5 mtr below ground and connected to GI earth wire 4 mm by means of GI bolts and nuts,check nuts,washers and GI earth wire protected by GI pipe light grade 15 mm bore and connecting to Panel/DBs etc as per site requirement including alternate layers of charcoal & salt crystal, necessary excavation, earth work in any type of soil PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete incl watering pipe 20mm dia medium grade with funnel complete with mesh all as shown in electrical plate No. 3 of MES Schedule Part 1 complete including testing on completion all as specified and as directed . \nNote :- (i)Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc. (ii) GI earth wire, GI tubing light grade 15mm bore upto 7.5 mtr deemed to be included in the rate quoted by the contractor. (iii) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost. | 8 | Each | |
64 | 57 | Supply,Fixing and Testing LED street light luminaire fitting of not less than 25 Watt of not less then IP 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. \nMake :Surya Cat-SLE UL 25W IP66 LXN / Philips/Wipro/ LUKER\nNote:-\n(i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants , necessary drilling,bolts/screws for fixing new one etc as per site requirement.and MS frame work if any complete as per site requirement. \n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. \n | 15 | Each | |
65 | 58 | Material and labour for PCC 1:3:6 type C1 using 20 mm grade stone aggregate as in copping of electric pole at site including providing necessary form work etc including demolition complete all as specified and as directed. | 1.5 | Cum | |
66 | 59 | Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wiredrawn in existing conduit complete all as specified and as directed. | 230 | RM | |
67 | 60 | Supply,Fixing and Testing LED street light luminaire fitting of not less than 60 Watt,Luminaire fitting of not less then IP 65 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 5 KV complete including taking down the old unserviceable/damaged light fittings and making good disturbed surfaces all as specified and directed. Make : Surya Cat-SLE UL 60W IP66 LXN / Philips/WiproLUKER \nNote:- (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants , necessary drilling,bolts/screws for fixing new one etc as per site requirement.and MS frame work if any complete as per site requirement. (ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. \n | 10 | Each | |
68 | 61 | Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth for taking up / laying cable etc and getting out for soft/loose soil complete all as specified and directed. | 189 | Cum | |
69 | 62 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as directed. | 132 | Cum | |
70 | 63 | Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed. | 57 | Cum | |
71 | 64 | Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and directed. | 2.9 | Per 1000 Nos | |
72 | 65 | Relaying of reusable bricks as obtained from item ser No 61 here-in-before complete all as specified and directed. | 2.6 | Per 1000 Nos | |
73 | 66 | Spreading riddled earth as obtained from item No. 61 here-in-before in cable trenches all as specified and directed. | 57 | Cum | |
74 | 67 | Supply and lay pipe galvanised iron tubing light grade of 40 mm dia in trenches/under road or floor/on wall / near pole/panel etc all as per site requirement complete all as specified and directed. | 68 | RM | |
75 | 68 | Supply,laying for 16 sqmm 4 core XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor for replacement of un serviceable portion of cable,connecting with proper size Aluminium lugs, glands whereever necessary near LT Panels / Bus bar chamber panel/joints/poles including taking down the old unsevicaeble cable all as per site requirement , testing complete all as specified and directed. \nMake -: UNIVERSAL / POLYCAB / NICCO /Havells . | 690 | RM | |
76 | 69 | All as per item no-68 here-in-before but 25 Sqmm cross sectional area 4 core cable complete all as specified and directed . \nMake -: UNIVERSAL / POLYCAB / NICCO /Havells. | 180 | RM | |
77 | 70 | Supply and fix LED outdoor type LED Bollard type fitting not less than 12W and including taking down old unserviceable fittings all as specified and as directed.\nMake :Crompton Cat Part No :LBLSR-10-WW /Surya cat ref :SLE BL 12W-FLR650 or equivalent model of Philips/wipro. | 5 | Each | |
78 | 71 | Supply and fix LED outdoor type narrow beam light fitting not less than 10W with necessary connecting arrangements and including taking down old unserviceable fittings all as specified and as directed.\nMake :Crompton /Surya/ Philips/wipro. | 5 | Each | |
79 | 72 | Supply,fixing and Testing LED post top 40 Watt High output with single piece construction comprises of die cast housing and clear acrylic & spun aluminium reflector,not less then IP 65 Protection lighting luminaire and including taking down old unserviceable fittings complete all as per site requirement and all as specified and directed.Make:Crompton/Surya/Philips/Wipro. | 10 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail