Various Electricity Line Works In Deposit Scheme (Running Contract), In The Jurisdiction Of Edd-Ii, Hapur, Under Edc., Hapur., Hapur-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Various Electricity Line Works In Deposit Scheme (Running Contract), In The Jurisdiction Of Edd-Ii, Hapur, Under Edc., Hapur.. Submission Date for this Tender is 25-06-2021. Bolts Tenders in Hapur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28169994
Various Electricity Line Works In Deposit Scheme (Running Contract), In The Jurisdiction Of Edd-Ii, Hapur, Under Edc., Hapur.
Open Tender
Indian
Uttar Pradesh
Hapur
25-06-2021

Tender Details

Various Electricity Line Works In Deposit Scheme ( Running Contract ) , In The Jurisdiction Of Edd-Ii, Hapur, Under Edc., Hapur.-1 For Various Electricity Line Works, In Deposit Scheme ( Running Contract ) , In The Jurisdiction Of Edd-Ii, Hapur, Under Edc., Hapur. 2 Carriage Of Line Material ( Like 11Kv Xlpe Cable 3X35-3X70+3X120-3X185sqmm, And 11Kv Cable Jointing Kit Indoor / Outdoor Type Etc. ) From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road. 3 Carriage Of St Pole 11 Mtrs. Long From Electricity Store Center, Hapur / J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road. 4 Carriage Of Pcc Pole 8.5 Mtrs. Long From Electricity Store Center, Hapur / J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road. 5 Carriage Of 10Kva To 250Kva From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road. 6 Carriage Of 11Kv Ct / Pt Unit From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road. 7 Carriage Of Metering Cubical Set Complete, From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road. 8 Erection & Fixing Of Pcc Pole 8.5 Mtr. Long In 11 Kv Line After Digging Of Suitable Pits Including Fixing Of Requisite Accessories As Per Respo Drawing / Norms By Providing F-Bracket Made Of M.S. Flat Of Size 50X6 Mm, Cross Arm Holding Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts. 9 Erection & Fixing Of Stp Pole 11 Mtr. Long In 11 Kv Line After Digging Of Suitable Pits Including Fixing Of Requisite Accessories As Per Respo Drawing / Norms By Providing F-Bracket Made Of M.S. Flat Of Size 50X6 Mm, Cross Arm Holding Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts. 10 Fabrication, Erection And Fixing Of Double Pole On St Pole 11 Mtr. Long With Fixing Of M.S. Top & Dropper Channel, M.S. S / S Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting As Per Respo Drawing / Norms By Providing Top And Dropper Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts. 11 Mounting, Placing And Connecting From Lt / Ht Side Of 11Kv, 10 To 250Kva T / F As Per Respo Norms. 12 Mounting, Placing And Connecting From Lt / Ht Side Of 11Kv, Ct / Pt Units As Per Respo Norms. 13 Laying Of 11Kv Xlpe Cable 3X35-3X70+3X120-3X185sqmm, As Per Respo / Norms. 14 Making And Filling Of 11Kv Cable Jointing Kit Indoor / Outdoor Type, Suitable For 11Xlpe Cable As Per Respo Norms. 15 Installation Of 11Kv Metering Cubical Complete Work As Per Respo Norms. 16 Fabrication & Fixing Of T-Channel On Pole By Providing Holding Clamps, F-Clamps & Proper Size Nuts & Bolts, As Per Respo / Norms. 17 Grouting & Fixing Of Stay Rods ( 20X1800 ) Mm Including All Work Of Excavation, Cement Concrete In Size ( 0.60X0.60X0.30 ) M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing / Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops. 18 Earthing Of Supports With Ms Earth Rod Of ( 20X2500 ) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing / Norms By Providing Proper Size Nuts & Bolts. 19 Grouting Of St Supports In Cc 1:4:8 ( Cement, Sand & 40Mm Brick Ballast ) Grouting Will Be Done In The Block Of Size ( 450X450 ) Mm X1 / 6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With Cc 1:3:6 ( Cement, Core Sand And Stone Grit ) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials. 20 Laying , Stringing And Final Sagging Of Acsr Weasel Conductor After Binding From Insulator, As Per Respo / Drawing Norms. 21 Acsr Weasel Conductor 22 Acsr Rabbit Conductor 23 Acsr Dog Conductor 24 Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv 3X70 And 3X120sq.Mm Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends. 25 Construction Of T / F Plinth Suitable For 250Kva T / F ( Size Of 2 X 2 X 1.5 Mt. ) As Per Drawing, Cc Work In Foundation In Ratio 1:4:8 ( Cement, Sand & Brick Ballast ) . Ist Class Brick Work In Side Walls Cc Ratio Of 1:4 ( Cement & Fine Sand ) . 12Mm Thick Plaster In Ratio 1:4 ( Cement & Fine Sand ) . The Rcc Work On Top Of Plinth In Ratio 1:2:4 After Duly Filling Of Brick Ballast Inside The Plinth & Ramming The Same, Including Cost Of All Material & Labour. 26 Dismantling & Removal Of Old & Used 25 / 63Kva T / F And Opening Of All Accessories. 27 Carriage Of Old & Used 25 / 63Kva T / F From Site Of Work To Electricity Store Center, Hapur With Loading And Unloading At Both Ends On Kachha Packka Road. 28 Erection & Fixing Of Chemical Earthing As Per Respo Norms And Proper Completion Work Complete ( According To Sanctioned Estimate Concerned ) . 29 Jumpering Work Properly As Per Respo / Norms.

Key Value

Document Fees
INR 1180 /-
EMD
INR 10000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: FOR VARIOUS ELECTRICITY LINE WORKS IN DEPOSIT SCHEME (RUNNING CONTRACT), IN THE JURISDICTION OF EDD-II, HAPUR, UNDER EDC., HAPUR.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 FOR VARIOUS ELECTRICITY LINE WORKS, IN DEPOSIT SCHEME (RUNNING CONTRACT), IN THE JURISDICTION OF EDD-II, HAPUR, UNDER EDC., HAPUR. BI01010001010000000000000515BI0100001112
2 1.01 Carriage of line material (like 11KV XLPE Cable 3x35-3x70+3x120-3x185sqmm, and 11KV Cable Jointing Kit indoor/outdoor type etc.) from Electricity Store Center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road. BI01010001010000000000000515BI0100001113 36.3 Qtl.
3 1.02 Carriage of ST Pole 11 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road. BI01010001010000000000000515BI0100001115 90 Nos.
4 1.03 Carriage of PCC Pole 8.5 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road. BI01010001010000000000000515BI0100001115 20 Nos.
5 1.04 Carriage of 10KVA to 250KVA from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road. BI01010001010000000000000515BI0100001115 30 Nos.
6 1.05 Carriage of 11KV CT/PT Unit from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road. BI01010001010000000000000515BI0100001115 10 Nos.
7 1.06 Carriage of Metering Cubical Set Complete, from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road. BI01010001010000000000000515BI0100001115 10 Nos.
8 1.07 Erection & Fixing of PCC Pole 8.5 mtr. long in 11 KV line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing F-Bracket made of M.S. Flat of size 50x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts. BI01010001010000000000000515BI0100001115 20 Nos.
9 1.08 Erection & Fixing of STP Pole 11 mtr. long in 11 KV line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing F-Bracket made of M.S. Flat of size 50x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts. BI01010001010000000000000515BI0100001115 10 Nos.
10 1.09 Fabrication, erection and fixing of double pole on ST Pole 11 mtr. long with fixing of M.S. Top & Dropper Channel, M.S. S/S Angle, E-Bracket, 11 KV Pin insulator with Pin, Disc Insulator with Disc fitting as per RESPO Drawing/Norms by providing top and dropper clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts. BI01010001010000000000000515BI0100001115 40 Nos.
11 1.1 Mounting, Placing and connecting from LT/HT side of 11KV, 10 to 250KVA T/F as per RESPO Norms. BI01010001010000000000000515BI0100001115 30 Nos.
12 1.11 Mounting, Placing and connecting from LT/HT side of 11KV, CT/PT Units as per RESPO Norms. BI01010001010000000000000515BI0100001115 10 Nos.
13 1.12 Laying of 11KV XLPE Cable 3x35-3x70+3x120-3x185sqmm, as per RESPO/Norms. BI01010001010000000000000515BI0100001115 450 mtrs
14 1.13 Making and filling of 11KV Cable Jointing Kit Indoor/outdoor type, suitable for 11XLPE Cable as per RESPO Norms. BI01010001010000000000000515BI0100001115 20 Nos.
15 1.14 Installation of 11KV Metering Cubical Complete work as per RESPO Norms. BI01010001010000000000000515BI0100001115 5 Nos.
16 1.15 Fabrication & Fixing of T-Channel on pole by providing Holding Clamps, F-Clamps & Proper size nuts & bolts, as per RESPO/Norms. BI01010001010000000000000515BI0100001115 40 Nos.
17 1.16 Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops. BI01010001010000000000000515BI0100001115 40 Nos.
18 1.17 Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts. BI01010001010000000000000515BI0100001115 50 Nos.
19 1.18 Grouting of ST supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials. BI01010001010000000000000515BI0100001115 90 Nos.
20 2 Laying , Stringing and final sagging of ACSR Weasel Conductor after binding from Insulator, as per RESPO/Drawing Norms. BI01010001010000000000000515BI0100001115
21 2.01 ACSR Weasel Conductor BI01010001010000000000000515BI0100001115 4500 Mtr.
22 2.02 ACSR Rabbit Conductor BI01010001010000000000000515BI0100001115 1500 Mtr.
23 2.03 ACSR Dog Conductor BI01010001010000000000000515BI0100001115 2500 Mtr.
24 3 Providing & Fixing of G.I. pipe 6"dia Class-B over 11KV 3X70 and 3x120Sq.mm XLPE cable before mounting the cable at double pole. The work includes fitting of clamps, sealing of top and bottom of pipe and one end of pipe is to be burried under earth about 500mm earch including mounting and clamping the cable on double pole structure and making connection with overhead line at both ends. BI01010001010000000000000515BI0100001115 70 mtrs
25 4 Construction of T/F plinth suitable for 250KVA T/F (size of 2 x 2 x 1.5 mt.) as per drawing, cc work in foundation in ratio 1:4:8 (Cement, Sand & Brick ballast). Ist class brick work in side walls cc ratio of 1:4 (cement & fine sand). 12mm thick plaster in ratio 1:4 (cement & fine sand). The RCC work on top of plinth in ratio 1:2:4 after duly filling of brick ballast inside the plinth & ramming the same, including cost of all material & labour. BI01010001010000000000000515BI0100001115 2 Nos.
26 5 Dismantling & Removal of old & used 25/63KVA T/F and opening of all accessories. BI01010001010000000000000515BI0100001115 5 Nos.
27 6 Carriage of old & used 25/63KVA T/F from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road. BI01010001010000000000000515BI0100001115 5 Nos.
28 7 Erection & fixing of Chemical earthing as per RESPO Norms and proper completion work complete (according to sanctioned estimate concerned). BI01010001010000000000000515BI0100001115 15 Nos.
29 8 Jumpering work properly as per RESPO/Norms. BI01010001010000000000000515BI0100001115 40 Job