Construction Of Pump House And Installation Of Pump Motor Etc At Birendra Nagar Under Bishalgarh Municipal Council During The Year 2021 22 / Sh Construction Of Pump House And Installation Of Pump Motor In / Cl Pannal Board And Electrical Accessories Et , Agartala-Tripura

Public Works Department-PWD has published Construction Of Pump House And Installation Of Pump Motor Etc At Birendra Nagar Under Bishalgarh Municipal Council During The Year 2021 22 / Sh Construction Of Pump House And Installation Of Pump Motor In / Cl Pannal Board And Electrical Accessories Et . Submission Date for this Tender is 02-07-2021. Motor Work Tenders in Agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

28158614
Construction Of Pump House And Installation Of Pump Motor Etc At Birendra Nagar Under Bishalgarh Municipal Council During The Year 2021 22 / Sh Construction Of Pump House And Installation Of Pump Motor In / Cl Pannal Board And Electrical Accessories Et
Open Tender
Indian
Tripura
Agartala
02-07-2021

Tender Details

Construction Of Pump House And Installation Of Pump Motor Etc At Birendra Nagar Under Bishalgarh Municipal Council During The Year 2021 22 / Sh Construction Of Pump House And Installation Of Pump Motor In / Cl Pannal Board And Electrical Accessories Et

Key Value

Document Fees
INR 1000 /-
EMD
INR 4999.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Construction of Pump House and installation of pump motor etcat Birendra Nagar under Bishalgarh Municipal Councilduring the year 2021 -22./SH:-Construction of pump house & installation of pump motor in/cl pannal board and electrical accessories etc. (Under RIDF XXII Replacement).
Sl. No. Item Description
1Earthwork in excavation by mechanical means ( Hydraulic excavator ) / manual means in foundationtrenches or drains(not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. All kinds of soil ( by Manual means).
2Supplying & filling in plinth, under floor, foundations etc. with sands (fine) from local quarry with all lifts, i/c spreading in horizontal layers, watering, grading to required slope, ramming, consolodating and compacting each layer by using plate compactor or by any suitable method complete.
3Filling available excavated earth ( excluding rock in trenches, plinth, sides of foundations etc. in layers not execeding 20 cm in depth, consolidating each deposited layer by ramming ramming & watering, lead upto 50 m and lift upo 1.5 m. All kinds of soil.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering & shutering all work upto plinth level. (1) 1 :3 : 6 ( 1 cement : 3 fine sand : 6 graded well burnt brickaggregate of 20 mm nominal size)
5(2) 1 : 2 : 4 ( 1 cement : 2 fine sand : 4 graded well burnt brickaggregate of 20 mm nominal size)
6First class brick work in foundation and plinth including cost of all materials as required complete. In Cement mortar 1:6 ( 1 cement : 6 fine sand ).
7First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ).
8Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc. complete. 40 mm thick with 20 mm brick aggregate
912 mm cement plaster of mix. In Cement mortar 1:6 ( 1 cement : 6 fine sand )
10Neat cement punning.
11Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level.i)Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars.
12Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- In plinth and skirting courses, fillets, columns, pillars, posts and struts i)1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size)
13Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- i)1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size)
14Centering shuttering including struttings, propping etc. and removal of form work for: i) Foundations, footings, bases for columns etc. for mass concrete with timber plank.
15ii) Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank.
16Providing and fixing M.S. round holding down bolts with nutsand washer platyes complete as per standard design.
17Steel work in built up tubular (round,square or rectangular hollow tubes etc.) trusses etc.includng cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete:- i) Hot finished welded type tubes
18Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:- Using flats 30x6mm for diagonal braces and central cross piece.
19Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to steel windows by welding.
20Providing and fixing M.S. bolts i/c nuts and washer complete as per standard design. Upto 300 mmlength.
21Providing and placing of G.I. pipe over the pump house on top portion of the R.C.C. column as per specification and the direction of the Engineer-in-charge. i) 150 mm dia.
22ProvidingcorrugatedG.S.sheetroofingincludingvertical/curved surface fixedwithpolymercoatedJorLhooks,bolts andnuts8mm diameterwithbitumenandG.I.limpetwashersorwithG.I.limpet washersfilledwithwhiteleadandincludingacoatofapprovedsteel primerandtwocoatsofapprovedpaintonoverlappingofsheets complete(uptoanypitchinhorizontal/verticalorcurvedsurfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63mm thick with zinc coating not less than 275gm/m2
23Painting with synthetic enamel paintof required colour of approved brand and manufactureto give an even [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Two or more coats on new work.
24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats) over and including water thinnable priming coat with cement primer.
25Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of TestCertificate issued by the Manufacturer] :New work ( two or more coats applied @ 3.84 kg/10 sqm).
26Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : i) 200 x 10 mm
27Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : i) 125 mm.
28Finishing with epoxy paint ( two or more coats ) of approved brand and manufacture at all locations prepared and applied as per manufacturer"s specification on new work including appropriate priming coat, preparation of surface etc. complete in/c cost of materials required on steel work (Payment shall be made after submission of Test Certificate issued by the Manufacturer.) On steel work.
29Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ).
30SH:- B - Installation of Pump Motor Installation of submerssible pump with suitable motor upto the depth of 80 ft to 100 ft by 65 / 80 / 100 / 125 mm dia GI pipe welded with GI flange in/c providing fitting fixing by necessary rubber washer, nuts & bolts, MS safety clamp etc. as per required size and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run as per direction of the Engineer-in-charge ( pump, motor with cable, 65 / 80 / 100 / 125 mm dia GI pipe for assembly will be issued by the Department at free of cost ). ii) 5000 / 7500 GPH capacity with 10 mm thick GI flange
31Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inchx 9 feet ), nuts & bolts etc. for irrection of the same by1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and paintingtwo ormore coats & plastic paint as per specification and direction of the Engineer-in-charge.
32Providing and fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge. ii. 16 sqmm
33Providing and fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge.
34Providing and fitting fixing3 phase indicating lamp fiited with panel board with three different colour lamps with batten holder completeas per specification and direction of the Engineer-in-charge.
35Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge.
36Providing earthing with perforated 40 mm dia G.I. pipe (Medium class) ( 12 mm dia perforation ) ,laying of 4 mm dia GI wire from earth electrode to panel,including excavating hole of 600 mm dia and refilling with Salt and Charcoal / coke in alternate layers of 300 mm , as per standard specification and direction of the Engineer-in-charge. ii)for 3-phase connection with 4.00 mtr. Long G.I. pipe.
37Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge.25 HP/18.5 kw Relay range within 13-21 + 10%.
38Providing and fitting fixing of Moulded Case Circuit Breaker (MCCB) of different Thermal release range , 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge. i) 50-63Amps
39Providing & fabrication of column pipe includingfitting fixing of G.I. flange by cutting the GI pipe ( conforming to IS : 1239 medium class ) into 3.05 mtr. long and welding the same with GI flange as per specification and direction of the Engineer-in-charge ( G.I. pipe will be provided by the agency at his own cost & risk). iii) For 80 mm dia G.I. pipe with 10 mm thick GI flange
40Providing and fitting fixing of pressure meter (0.0 - 14.0 Kg/ sqcm.) as per specification and as per specification and thedirection of the Engineer - in-charge.
41Providing and fitting fixing heavy duty box type (Resin filled) power factor correction capacitorL & T make etc. completeas per specification and direction of the Engineer-in-charge. i) 5-15 kVAr 440 V.
42Providing andfixing C.I. double action air valve of approved quality with bolts, nuts, rubber insertionsetc. complete as perCPWD specification and direction of the Engineer - in - charge. ( The tail pieces, tapers etc if required will be paid separately ). i) 100 mm dia
43Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses) Tripal pole with neutral link (TPN 415/500 VOLT complate as per dit=rection of the engg-in-charge a)current range 100 amps
44b)current range 200 amps
45Providing and Supplying of Submersible pump motor set including carriage complete as per specification and direction of the Engineer-in-charge. i) 10.00 LPS 40 m head (7500 GPH)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail