Repair/ Replacement Of Unserviceable Spares Of Cooling Tower Ahus Pumps And Miscellaneous Ducting Works Including False Ceiling At Officers Family Ward Polyclinic Eye/Ent Ward C1 C2 Wards And Adjoining Area Of Base Hospital Under Ge ( E/M ) Base, GE E/M BASE HOSPITAL DELHI CANTT-Delhi

Military Engineer Services-MES has published Repair/ Replacement Of Unserviceable Spares Of Cooling Tower Ahus Pumps And Miscellaneous Ducting Works Including False Ceiling At Officers Family Ward Polyclinic Eye/Ent Ward C1 C2 Wards And Adjoining Area Of Base Hospital Under Ge ( E/M ) Base. Submission Date for this Tender is 08-07-2021. Cooling Tower Tenders in GE E/M BASE HOSPITAL DELHI CANTT Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

28140664
Corrigendum : Repair/ Replacement Of Unserviceable Spares Of Cooling Tower Ahus Pumps And Miscellaneous Ducting Works Including False Ceiling At Officers Family Ward Polyclinic Eye/Ent Ward C1 C2 Wards And Adjoining Area Of Base Hospital Under Ge ( E/M ) Base
Open Tender
Indian
Delhi
GE E/M BASE HOSPITAL DELHI CANTT
08-07-2021

Tender Details

Repair / Replacement Of Unserviceable Spares Of Cooling Tower Ahus Pumps And Miscellaneous Ducting Works Including False Ceiling At Officers Family Ward Polyclinic Eye / Ent Ward C1 C2 Wards And Adjoining Area Of Base Hospital Under Ge ( E / M ) Base

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-07-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 93000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/ REPLACEMENT OF UNSERVICEABLE SPARES OF COOLING TOWER, AHUS, PUMPS AND MISCELLANEOUS DUCTING WORKS INCLUDING FALSE CEILING AT OFFICERS FAMILY WARD, POLYCLINIC, EYE/ENT WARD, C1, C2 WARDS AND ADJOINING AREA OF BASE HOSPITAL UNDER GE (E/M) BASE HOSPITAL DELHI CANTT-10
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Comprehensive maintenance including replacement of defective/ unserviceable parts/ fittings of Hot water Generators (Make: Rapid Cool) - (02 Nos) complete all specified and as directed. Contractor shall be responsible for repair and replacement of all the defective parts of complete hot water generator including pipelines and connected infrastructure and connected accessories during entire contract period. Replacements of all defective/ unserviceable parts and periodical painting, fabrication work, if any required to maintain smooth functioning of equipments, control and power wiring etc required for smooth functioning of 02 Nos equipments during entire comprehensive maintenance period shall be included in rate quoted by the contractor. 11 Per Month
2 1.01 Notes:-\n(i) Rate quoted by the contractor shall be for two Nos Hot water plants on monthly bases. \n(ii) Quoted rates shall be inclusive of labour element and replacement of defective/ unserviceable parts/ fittings during complete comprehensive maintaince period. Old parts shall not be re-used and shall be deposited in MES store yard by the contractor. \n(iii) Contractor shall provide all kind of tools without any extra cost as per OEM recommendation.\n(iv) Tradesman shall take all preventive measures as per Code of practice of IE rules and the department shall not be responsible for any type of untowards incident.\n(v) Tradesmen shall rush to spot of fault within 2 Hours of lodging complaint by the User Rep, JE in Charge or Engr-in-Charge telephonically or by any other means at their own arrangement to restore the faults of equipments and to attend the complaint. If the complaint is not attended within 2 Hours, a penalty of Rs 500.00 Per complaint per Hour shall be imposed on contractor.\n(vi) Contractor shall provide insulation tape, cotton waste and all tools i.e hand gloves, spanner set, tool kit, tool bag etc. without any extra cost to Govt. \n(vii) Equipments/ Machinery shall always be kept neat & clean and maintain in presentable condition.\n(viii) Proper Protective clothing of maintenance staff employing in breakdown duty shall be arrange by contractor without any extra cost to Govt.
3 2 S&F in repair 50mm thick box type Pre-Filter (EU-4) Synthetic media type flange type (non woven type) efficiency - 90% down to 10 micron with all fittings for AHU and 50 mm wg static pressure with rod support fabrication with GI/Aluminium frame, suitable for AHU of Make Fedders Lloyd complete all as specified & as directed. Make : AAF/ Fredenberg/ Thermodyne 12 Sqm
4 3 S&F in repair 3 pole, power contactor, 415 V, type MNX 25, including NO or NC auxiliary contact block, coil voltage 230 Volt, including connecting complete all as specified and as directed.\n 2 Each
5 4 S&F in repair 3 pole, power contactor, 415 V, type MNX 18, including NO or NC auxiliary contact block , Coil voltage 230 Volt, 50 Hz including connecting complete all as specified and as directed.\n 2 Each
6 5 S&F in repair 3 pole, power contactor, 415 V, type MNX 32, including NO or NC auxiliary contact block, coil voltage 230 Volt, including connecting complete all as specified and as directed.\n 1 Each
7 6 S&F in repair 3 pole, ML2 contactor, including NO or NC AUXILIARY contacts, including connecting complete all as specified and as directed.\n 1 Each
8 7 S&F in repair 3 pole, ML6 contactor, 415 Volt including NO or NC AUXILIARY contacts, including connecting complete all as specified and as directed.\n 1 Each
9 8 M & L in replacement under deck insulation for metal roof with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and Kraft paper (FSK), facing with 50 mm projection for overlap and butting in following operations complete all as directed and specified:- \n(a) S&F in replacement 6 mm dia M S rods between purlins suitably for supporting the required thickness of insulation material beneath the metal roof.\n(b) S&F in replacement 22 SWG GI/ Aluminium wires supports for insulation.\n(c) S&F in replacement chicken wire mesh 12.5 mm x 22 SWG of hexagonal construction below the insulation for supporting the same.\n(d) S&F in replacement under deck insulation with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and Kraft paper (FSK), facing with 50 mm projection for overlap and butting.\nNote:- Insulating material shall be conforming to BS - 476, Part 4, 5, 6 & 7. 1450 Sqm
10 9 Supply, assembly and erection in replacement GI sheet with C & SS rectangular/ square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete including necessary MS Channels, gurder supports as approved by Engr-in-Charge including making of hole in any type of wall and making good with plastering work, masonry work and necessary MS channel supports complete all as specified and directed for the following sizes:-
11 9.01 24 Gauge GI Sheet 1610 Sqm
12 9.02 22 Gauge GI Sheet 320 Sqm
13 10 Supply & erection in replacement 25 mm thick nitrile duct thermal insulation with Aluminium foil, non-fibrous, fire retardant, closed cell, tri- dimensional, chemically cross linked polyethylene foam, confirm to class O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminium foil complete all as specified and as directed.\n 1700 Sqm
14 11 S&F in replacement Acoustic treatment/ lining of area of AHU room with 22 Gauge, GI channels of 50x50 mm size fitted at 600x600mm girds, fitted with 50mm thick, 32 Kg/cum fibber glass insulation, covered with fibber glass tissue and 24 Gauge Aluminium perforated sheet as required, The joint shall be with minimum overlapping of 75mm with 30mmx 3mm aluminium strip covering, All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and as directed. 375 Sqm
15 12 S&F in replacement acoustic lining of supply air ducting complete with GI frame, tissue paper, 26 Gauge perforated Aluminium Sheet, 25mm thick, of density 32 Kg/cum fiber glass insulation complete all as specified and as directed. 52 Sqm
16 13 S&F in replacement air volume control damper with connected accessories, made out of 22 Gauge GI Sheet with flap and operating handle complete all as specified and as directed. 32 Sqm
17 14 Supply, installation, testing and balancing in repair square shape supply air diffusers with removable core and antismudge ring and volume control dampers, powder coated, extruded aluminium construction complete all as specified and as directed. 18 Sqm
18 15 Supply, installation, testing and balancing in repair square shape return air diffusers with removable core and antismudge ring and without control dampers, with powder coated, extruded aluminium construction complete all as specified and as directed. 18 Sqm
19 16 Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including frame work & cover fillets etc complete all as specified and as directed. 600 Sqm
20 17 S&F powder coated Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm, suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm, fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed. 600 Sqm
21 18 S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level, fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size, 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed. 600 Sqm
22 19 S&F 4.00 mm thick Non asbestos fibre cement building boards (E Board), designer pattern, fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed. 600 Sqm
Disclaimer :