Military Engineer Services-MES has published Repair Maint Of Split Acs Window Acs Water Coolers Refrigerators And Desert Coolers In Sector C Under Ge Utility Ambala Cantt. Submission Date for this Tender is 07-07-2021. Air Cooler Tenders in AMBALA CANTT Haryana. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 30-Jun-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-07-2021 |
Name of Work : REPAIR/MAINT OF SPLIT ACs, WINDOW ACs, WATER COOLERS, REFRIGERATORS AND DESERT COOLERS IN SECTOR ‘C’ UNDER GE (U) AMBALA CANTT. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down the window type AC of any capacity from existing location and shifting & installation at another location after cleaning coil & greasing etc. for satisfactory working as directed by Engr-In -Charge. | 4 | Each Job | |
2 | 2 | Taking down the split type AC of any capacity from existing location and shifting & installation at another location after cleaning coil & greasing etc. for satisfactory working as directed by Engr-In -Charge. | 4 | Each Job | |
3 | 3 | Disconnecting from mains and Taking out existing unserviceable compressor sealed unit from the window type Air Conditioner of Cap 2 Ton, of any make any type from any location and Supply , Installing and testing of company made new sealed unit compressor with one year guarantee including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification (caplary tube etc ) & Charging of Gas F-22/R-134A and commisioning as directed by Engr-in-Charge , \nNote :- Transportation Charges From site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted. | 7 | Each Job | |
4 | 4 | Description all as per item No. 3.00 above but Window Air Conditioner of Cap 1.5 Ton. | 5 | Each Job | |
5 | 5 | Description all as per item No. 3.00 above but spilt type Air Conditioner of Cap. 2 Ton. | 4 | Each Job | |
6 | 6 | Description all as per item No. 3.00 above but spilt type Air Conditioner Cap. 1.5 Ton. | 4 | Each Job | |
7 | 7 | Disconnecting form mains and Taking out unserviceable fan motor/ blower motor of window type AC 1.5/2 ton capacity of any make and type from any location and supply, installing and testing new fan motor as per existing capacity and model all as directed by Egnr-in-charge.\nNote :- Transportation Charges From site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted. | 4 | Each Job | |
8 | 8 | Description all as per item No 7.00 above but for split type AC 1.5/2 TR and ditto. | 4 | Each Job | |
9 | 9 | Taking down unserviceable copper pipe of size 1/4" and supply & fixing new copper pipe 1/4" complete including brazing, welding, nut bolts and screws of reqd size complete all as directed by Engr-in-Charge | 20 | RM | |
10 | 10 | Description all as per item No 9.00 above but size of copper pipe 5/8" | 15 | RM | |
11 | 11 | Description all as per item No 9.00 above but size of copper pipe3/8" | 10 | RM | |
12 | 12 | Description all as per item No 9.00 above but size of copper pipe 1/2" | 12 | RM | |
13 | 13 | Material & labour for detecting the leakages of gas of window type AC capacity 1.5/2 TR from any location and rectified/stopped the leakages by gas welding or by any other means and make it functioning as directed by Engr-in-Charge | 8 | Each Job | |
14 | 14 | Description all as per item No 13.00 above but for split type AC 1.5/2 TR and ditto- | 8 | Each Job | |
15 | 15 | Charging only Refrigerant Gas F-22/R-134A in window type /Split Type AC Unit of capacity 1.5 /2Ton including testing and commissioning complete in satisfactory working condition. | 8 | Each Job | |
16 | 16 | Point wiring complete with 2 run of 4.00 sqmm single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade with multistranded copper conductor drawn through andincluding suitable size of PVC white Casing and Caping with all accessories like tee, straight joint, L Bend etc., fixed to walls / roofs / floors / ceiling etc., and including provision of PVC insulated heavy duty ISI Marked unsheathed copper conductor 4.00 sqmm forearth continuity conductor and connected to common earth dolly for 20 Amps Metal clad socket complete all as specified and directed. | 5 | Per Point | |
17 | 17 | Supply and Fix Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps including taking down old/unsv Metal clad socket of any make complete all as specified and directed. | 4 | Each | |
18 | 18 | Supply and fix MCB single pole, 240 volts, 5 to 40 Amps 10 KA complete including taking down old unservicable MCB of any type/capacity complete all as specified and as directed by Engr-in-Charge. | 4 | Each | |
19 | 19 | Reversible valve suitable for refrigerant R-22 for 1.5/ 2.0/ 3.0 TR AC including copper pipe required at site complete all as specified and as directed by Engr-in-Charge. | 4 | Each | |
20 | 20 | Disconnecting form mains and Taking out unserviceable condenser coil of window Type AC Cap. 1.5 Ton/2 Ton of any make and type from any location and supply, installing and testing new condneser coil as per existing capacity and make as directed by Engr-in- Charge. Make Voltas/Carrier/LG\nNote :- Transportation Charges From site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted. | 4 | Each Job | |
21 | 21 | Description all as per item No 20.00 above but for split type AC 1.5/2 TR and ditto-- | 3 | Each Job | |
22 | 22 | S & F in replacement of Evaporator /Cooling coil for window type AC Cap. 1.5 Ton /2 Ton Cap of existing make and size all as directed by Engr-in- Charge. | 4 | Each | |
23 | 23 | Description all as per item No 22.00 above but for split type AC 1.5/2 TR and ditto-- | 4 | Each | |
24 | 24 | Material & Labour one coat painting with synthetic enamel paint on the body of window type AC/Split type AC outer body unit capacity 1.5/2 TR of any make and capacity with colour as per existing at site complete all as directed by Engr-in-Charge. | 4 | Each | |
25 | 25 | Taking down unserviceable outdoor unit of split type AC (only body) of existing make type 1.5/2 Ton capacityand supply & fixing new outdoor unit ( only body) suitable for existing 1.5 /2TR capacity complete all as specified and as directed by Engr-in-Charge. | 2 | Each | |
26 | 26 | Taking down unserviceable indoor unit of split type AC of existing make type and 1.5/2 Ton capacity and supply & fixing new indoor unit complete copper assembly suitable for existing 1.5/2TR capacity complete all as directaed by Engr-in-Charge | 2 | Each | |
27 | 27 | Disconnecting from mains and servicing of Refrigerator/Deep freezer of Capacity 165 to 500 Ltrs including detecting the leakage of gas and refilling, cleaning of cooling coil, condenser, compressors, with vaccum cleaner OR cleaning solution including checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switch with knobs, etc., and keeping the Refrigerator unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge.\nNote :- 1. Replacement of defective parts shall be measured & paid separately as supply only under relevant items and Labour charges for fixing of defective parts shall deemed to be included in unit rate quoted. | 20 | Each Job | |
28 | 28 | Supply only Thermostat switch with Knob for Refrigerator/Deep freezer of 165 to 500 ltrs capacity | 10 | Each | |
29 | 29 | Supply only Starting relay 1/6 H.P. Open type with O.L.P. for Refrigerator/Deep freezer of 165 to 500 ltrs capacity | 10 | Each | |
30 | 30 | Supply only Starting relay 1/8 H.P. open type with O.L.P. for Refrigerator/Deep freezer of 165 to 500 ltrs capacity | 10 | Each | |
31 | 31 | Supply only copper filter single capillary pencil type for Refrigerator/Deep freezer of 165 to 500 ltrs capacity | 10 | Each | |
32 | 32 | Supply only Vegitable tray PVC suitable for Refrigerator of 165 to 500 ltrs capacity | 10 | Each | |
33 | 33 | Supply only Defrost tray suitable for Refrigerator of 165 to 500 ltrs capacity | 5 | Set of Two | |
34 | 34 | Supply only PVC ice tray flexible of existing type, make and size for Refrigerator of 165 to 500 ltrs capacity. | 5 | Each | |
35 | 35 | Supply only Refrigerator bottle shelf suitable for Refrigerator of 165 to 500 ltrs capacity | 5 | Each | |
36 | 36 | Supply only Waste water tray for Refrigerator of 165 to 500 ltrs capacity. | 5 | Each | |
37 | 37 | Supply only Freezer door for Refrigerator of 165 to 500 ltrs capacity. | 5 | Each | |
38 | 38 | Supply only Door Lock for Refrigerator of 165 to 500 ltrs capacity | 3 | Each | |
39 | 39 | Supply only chiller tray for Refrigerator of 165 to 500 ltrs capacity. | 3 | Each | |
40 | 40 | Supply only ice tray for Refrigerator of 165 to 500 ltrs capacity. | 4 | Each | |
41 | 41 | Supply only Door switch for Refrigerator of 165 to 500 ltrs capacity. | 4 | Each | |
42 | 42 | Supply only Interior light fittings with bulb for Refrigerator of 165 to 500 ltrs capacity. | 4 | Each | |
43 | 43 | Supply only Door handle suitable for Refrigerator of 165 to 500 ltrs capacity. | 4 | Each | |
44 | 44 | Supply only Refrigerator compartment Glass for Refrigerator of 165 to 500 ltrs capacity. | 3 | Each | |
45 | 45 | Disconnecting from mains and Taking down for servicing of Water Cooler of Capacity 40 Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vaccum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and keeping the Water cooler unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge.\nNote :- Replacement of defective parts shall be measured & paid separately under relevant items as supply only and Labour charges for fixing of defective parts shall deemed to be included in unit rate quoted. | 8 | Each Job | |
46 | 46 | Description all as per item No 45.00 above but for water cooler 150 ltrs capacity and ditto. | 7 | Each Job | |
47 | 47 | Supply only Over load protector device for 150 Ltr Cap. Water Cooler | 6 | Each | |
48 | 48 | Supply only Over load protect device for 40 Lts Cap. Water cooler | 6 | Each | |
49 | 49 | Supply only Starting relay open type/Box type suitable for 150 Ltr | 6 | Each | |
50 | 50 | Supply only Starting relay open type/Box type suitable for 40 Ltr water cooler | 6 | Each | |
51 | 51 | Supply only Starting Capacitor 36 MFD for water cooler 40/150 ltr capacity | 6 | Each | |
52 | 52 | Supply only Starting Capacitor 80-100 MFD for water cooler 40/150 ltr capacity | 6 | Each | |
53 | 53 | Supply only Running Capacitor 25 MFD for water cooler 40/150 ltr capacity | 6 | Each | |
54 | 54 | Supply only Drain Hose pipe 40mm for water cooler 40/150 ltr capacity. | 4 | RM | |
55 | 55 | Supply only Condenser fan blade plastic for fan Motorn 1/10/ 1/16 HP for water cooler 40/150 ltr capacity. | 3 | Each | |
56 | 56 | Supply only Condenser fan blade plastic for Motor 1/32, 1/35 for water cooler 40/150 ltr capacity. | 5 | Each | |
57 | 57 | Supply only Copper filter pencil type single / Double Capillary for water cooler 40/150 ltr capacity. | 5 | Each | |
58 | 58 | Supply only Self closing/pushtaps for water cooler Cap 150/40 Ltr for water cooler 40/150 ltr capacity. | 5 | Each | |
59 | 59 | Supply only R-22 refrigerant gas. | 20 | Kg | |
60 | 60 | Supply only R-134 refrigerant gas. | 20 | Kg | |
61 | 61 | Disconnecting the unserviceable compressor sealed unit of deep freezer of any make and type 230 V single phase of capacity 500 ltr by opening the nut bolt and supply and fixing new compressor suitable for 500 ltr deep freezer of make Kirloskar/Tachumsha procured from authrised dealer and fixing the compressor in original position and testing the same (with one year guarantee) including supply and charging Refrigerant R-134 gas and fixing copper tube Capilary, over load relay and starting relay etc. and making connection and put working condition complete all as specified and as directed by Engr-in-Charge. | 2 | Each Job | |
62 | 62 | Description all as per item No 61.00 above but for 320 ltr capacity deep freezer and ditto. | 2 | Each Job | |
63 | 63 | Description all as per item No 61.00 above but for 205 ltr capacity deep freezer and ditto. | 2 | Each Job | |
64 | 64 | Disconnecting from the mains and Taking out the existing unserviceable cooler fan motor and supply and fixing new cooler fan motor 1/10 HP capacity 3 speed single phase 240 volts for desert cooler including reconneting the electric connection and testing complete all as specified and directed by the Engr-in-charge. \n | 70 | Each | |
65 | 65 | Disconnecting from the mains and Taking out the existing unserviceable Water lifitng pump vertical pump/little submersible pump and supply and fixing new Water lifting pump heavy duty single phase 240 volts for desert cooler including reconneting the electric connection and testing complete all as specified and directed by the Engr-in-charge. | 80 | Each | |
66 | 66 | Taking down old U/s or rusted Angle iron stand and replace it with new angle iron stand for desert cooler/window AC made out of angle iron 40x40x5mm of required size with four legs including Leg support duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed by Engr-in-Charge. | 40 | Kg | |
67 | 67 | Disconnecting the electric connection and taking out unserviceable condenser fan motor 1/10, 1/16 HP from water cooler cap.150 Ltr and supply and replace with new motor single phase AC 220 V of same Cap including reconnecting the electric connections and testing complete all as directed by Engr-in- Charge.\n | 4 | Each Job | |
68 | 68 | Description all as per item No. 67.00 above but fan motor 1/32 HP and Water cooler of Capacity 40 Ltrs and ditto. | 4 | Each Job | |
69 | 69 | Disconnecitng the electric connections and taking out the unserviceable condenser coil fins type and supply & fixing new condenser coil fins type as per existing size & patterns for Water Coolers 150 ltrs ltrs capacity complete all as specified and directed by Engr-in-Charge. | 5 | Each | |
70 | 70 | Description all as per item No. 69.00 above but for water cooler 40 ltrs capacity and ditto. | 5 | Each | |
71 | 71 | Cutting the rusted unserviceable base of 150/40 Ltr Capacity. water cooler body and material and labour for fabrication of New Base made of MS sheet & angle as per existing size and thickness and shape incl welding or small patches as directed by Engr - in - Charge. | 2 | Each Job | |
72 | 72 | Taking down old U/s or rusted MS Side panels and repalce it with new MS Side panel set of three for desert cooler of exisiting size at site including wood wool pad set of three for desert cooler of size 70x70 cms having weight 500 gms each set complete all as specified and directed by Engr-in-Charge. | 2 | Each | |
73 | 73 | Collecting of unserviceable voltage stabilizer of capacity 0.5 to 2 KVA from the MES store yard (AGE E/M(E/S) ) , dismantling the same and transporting to workshop for locating the fault including checking the serviceablity of electrical/electronic circuits relays and repalcement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES sotre yard complete all as specified and directed by Engr-in-charge.\nNote :- Replacement of defective parts shall be measured & paid separately under relevant items as supply only and Labour charges for fixing of defective parts shall deemed to be included in unit rate quoted. | 6 | Each Job | |
74 | 74 | Description all as per item ser No. 73.00 herein before but voltage stabilizer of capacity 3 kva to 5 KVA and ditto. | 6 | Each Job | |
75 | 75 | Supply only Volt meter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply for Voltage stabilizer of Cap 0.5 to 5 KVA.\n | 5 | Each | |
76 | 76 | Supply only Digital type Volt meter 0 to 300 volts any type shape single phase 50 Hz AC supply for Voltage stabilizer of Cap 0.5 to 5 KVA. | 5 | Each | |
77 | 77 | Supply only printer circuit control card suitable for 0.5 to 2 KVA | 4 | Each | |
78 | 78 | Supply only printer circuit control card suitable for 3 KVA | 4 | Each | |
79 | 79 | Supply only printer circuit control card suitable for 4 KVA to 5 KVA | 4 | Each | |
80 | 80 | Supply only Input/output switch for Voltage stabilizer of Cap 0.5 to 5 KVA. | 6 | Each | |
81 | 81 | Supply only Push on switch for Voltage stabilizer of Cap 0.5 to 5 KVA. | 6 | Each | |
82 | 82 | Supply only Indicator complete with bulbs for Voltage stabilizer of Cap 0.5 to 5 KVA. | 6 | Each | |
83 | 83 | Supply only Trigger Transformer for 0.5 KVA to 2 KVA voltage stabilizer. | 6 | Each | |
84 | 84 | Supply only Trigger Transformer for 3 KVA to 5 KVA voltage stabilizer. | 4 | Each | |
85 | 85 | Supply only Relay for 0.5 to 2 KVA voltage stablizer | 4 | Each | |
86 | 86 | Supply only Relay for 3 to 5 KVA voltage stabilizer | 4 | Each | |
87 | 87 | Supply only Time delay and High/low voltage cut off circuit with relay suitable for 0.5 KVA to 2 KVA | 4 | Each | |
88 | 88 | Supply only Time delay and High/low voltage cut off circuit with relay suitable for 3 KVA to 5 KVA | 4 | Each | |
89 | 89 | Dismantling the evaporator/cooling coil of water cooler capacity 150/40 Ltrs, checking the leakages of gas and rectify the leakages by gas welding or as in other means as directed by Engr-in-Charge. | 5 | Each Job | |
90 | 90 | M & L charging only of Gas F-22 for the water cooler Cap. 150/40 ltrs including testing and satisfactory commissioning. | 5 | Each | |
91 | 91 | Disconnecting from mains and taking down the unserviceable compressor sealed unit of Refrigerator of 165 to 180 ltrs capacity and providing and fixing New Compressor suitable for 165 to 180 ltr Refrigerator & testing the same with one year gurantee including supply and charging of the refrigernt gas F-12 , R-134A and all other copper tubes, capillary, filter and put in working condition all as directed by Engineer-in-Charge. \nNote :- The Unit Rate quoted by the contractor shall deem to be included for replacement of filter, cleaning of condenser Nuts & bolts and making necessary connection and testing complete. | 4 | Each Job | |
92 | 92 | Description all as per item No. 91.00 above but capacity of the refrigerator 280/ 300/310 Ltrs and ditto. | 5 | Each Job | |
93 | 93 | M & L one coat of spray painting with synthetic enamel paint, any shade with machine as directed to refrigerator 165/310 lts cap including anticorrosive black paint on compressor, condenser coil incl Scratching out the existing paint with sand paper and filling up the scratches with putty complete all as directed by Engineer-in- Charge. | 2 | Each Job | |
94 | 94 | M & L charging only of gas refrigerant F-12/ R-134A after detecting or rectify the leakages incl cutting welding for Refrigerant cap. 165 Ltrs to 310 ltrs of any Make | 10 | Each | |
95 | 95 | Taking out unserviceable evaprotator/freezer from the refrigerator and supply & fixing evaporator/freezer made out of aluminium press type suitable for 280/300/310 ltr capacity Refrigerator with freezer frame and door including connection complete all as specified and as directed by Engr-in-Charge. | 5 | Each | |
96 | 96 | Description all as per item No. 95.00 above but capacity of the refrigerator 165 to 180 Ltrs and ditto. | 2 | Each | |
97 | 97 | Disconnecting the Electric & Water connection of the Desert Cooler incl taking down from its existing location removal of unserviceable side panel, Top cover W/Tank side support, grill regulator etc. Scratching old paint with sand paper complete cleaning inner & outer surfaces of the Desert Cooler body to make the surface smooth and painting the inner surfaces & Grills with two coats of black anticorrosive paint and outer surfaces with two coats of alluminium/ hammerton paint of 1st quality with spray machine and including checking the servicibility of Fan and submersible (little ) pump , selector switchs etc., and fixing the Desert Cooler at existing location including oiling & Greasing and making electric & water connections and testing the same complete all as specified and directed by Engr-in-Charge.\nNote :- Replacement of defective parts shall be measured & paid separately under relevant items as supply only and Labour charges for fixing of defective parts shall deemed to be included in unit rate quoted. | 30 | Each Job | |
98 | 98 | Supply only Capacitor 4 Mfd for desert cooler | 30 | Each | |
99 | 99 | Suppy only wood wool Cooler Pad set of Three 70x70 cms having wt of 500 gms each set for desert cooler. | 200 | Each Set of three | |
100 | 100 | Supply only Selector Switch with Knob for desert cooler. | 25 | Each | |
101 | 101 | Supply only MS Front Show grill for desert cooler as per exisitng size at site. | 25 | Each | |
102 | 102 | Supply only Plastic front Show grill for desert cooler as per existing size at site. | 12 | Each | |
103 | 103 | Supply only PVC Pipe 1/2 " with Elbow plastic as per exisiting length set of three | 20 | Each | |
104 | 104 | Supply only distirbutor box PVC for desert cooler. | 20 | Each | |
105 | 105 | Supply only Wooden ply of size 6mm thick and sheet size 3’x6’ water proof for desert cooler fixing of desert cooler/window AC | 10 | Each | |
106 | 106 | Supply only aluminium blades for fan motor of desert cooler. | 20 | Each | |
107 | 107 | Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 150 ltrs from any location and supply and fixing new compressor suitable for 150 ltr capacity water cooler with one year guarantee alongwith test certificate from manufacturer and cleaning of condenser by machine doing vaccum the whole system and supply and charging of gas and other necessary lubricants including reconnecting the electric and water connections & testing complete all as directed by Engr-in-charge. | 4 | Each Job | |
108 | 108 | Description all as per item No 107.00 above but Water cooler of Cap 40 Ltrs and ditto. | 4 | Each Job | |
109 | 109 | Taking out the burnt winding of transformer of voltage stablizer and prepairing core after cleaning by suitable cleaning agent and rewinding the transofrmer of voltage stablizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 0.5 KVA voltage stablizer.\n | 5 | Each | |
110 | 110 | Desctription all as per item No 109.00 above but for 1 KVA voltage stabilizer. | 3 | Each | |
111 | 111 | Desctription all as per item No 109.00 above but for 2KVA voltage stabilizer. | 4 | Each | |
112 | 112 | Desctription all as per item No 109.00 above but for 3 KVA voltage stabilizer. | 3 | Each | |
113 | 113 | Desctription all as per item No 109.00 above but for 4 KVA voltage stabilizer. | 3 | Each | |
114 | 114 | Desctription all as per item No 109.00 above but for 5 KVA voltage stabilizer. | 3 | Each | |
115 | 115 | Taking out the Water Cooler Tank from water cooler 150/40 ltrs capacity & repair the tank with brazing welding etc to stop the leakage of tank incl provn of inserting glass wool tarpaulin sheet etc and repair to cooling coil and refixing in original position & testing and commissioning complete all as specified and directed by Engr-in-Charge. | 5 | Each Job | |
116 | 116 | Cleaning & removing the existing paint from old steel surfaces of water coolers capacity 150 /40 Ltrs by rubbing & preparing the surface smooth & applying one coat of synthetic enamel paint by spray gun machine of colour as approved by Engr-in-Charge. | 5 | Each Job | |
117 | 117 | Taking out rusted/unserviceable MS sheet from water cooler of capacity 150/40 ltrs, supply & fixing new MS sheet of 22 SWG including nut bolts & screws and welding if required, painting with two coats of synthetic enamel grey paint over a coat of red oxide primer complete all as directed. | 5 | Sqm | |
118 | 118 | Supply & fixing in replacement of complete Top door made out of stainless steel 20 guage sheet with handle and locking arrangement with double keys including door gasket and recommended insulation material and PVC inner sheet of suitable thickness for 150/40 Ltr capacity water cooler as per eixsiting size and shape, welding work nuts bolts & washers all as directed. | 5 | Each Job | |
119 | 119 | Supply and Fix in replacement of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified and directed. | 10 | Each | |
120 | 120 | Supply and Fix G I Tubing 15 mm dia medium grade with all fittings in walls with suitable size clamps/saddles including taking down old unsv /rusted GI tubing and cutting in wall complete all as specified and directed by Engr-in-charge. | 6 | RM | |
121 | 121 | Supply and Fixing Stop vlave cast copper alloy screw down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15 mm dia bore including taking down old unsv /rusted stop valve complete all as specified and directed by Engr-in-charge. | 6 | Each | |
122 | 122 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of walls, floors, etc. | 5 | Per Point | |
123 | 123 | Point wiring complete with 2 run of 2.5 sqmm single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade with multistranded copper conductor drawn through andincluding suitable size of PVC white Casing and Caping with all accessories like tee, straight joint, L Bend etc., fixed to walls / roofs / floors / ceiling etc., and including provision of PVC insulated heavy duty ISI Marked unsheathed copper conductor 2.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches/socket outlets, 15 Amps S/S outlet. | 6 | Per Point | |
124 | 124 | Taking down split type AC 1.5/2TR Capacity for servicing including cleaning of cooling coil, air filters/plasma filters etc., (Indoor unit), condenser, compressors, fan motor etc., (Out door unit) with vaccum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit, fan, blower, etc., and keeping the AC unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge. \nNote :- Replacement of defective parts shall be measured & paid separately under relevant items as supply only and Labour charges for fixing of defective parts shall deemed to be included in unit rate quoted. | 60 | Each Job | |
125 | 125 | Taking down Window type AC 1.5/2TR Capacity for servicing including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit, fan, blower, etc., and keeping the AC unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge.\nNote :- Replacement of defective parts shall be measured & paid separately under relevant items and Labour charges for fixing of defective parts shall deemed to be included in unit rate quoted. \n | 60 | Each Job | |
126 | 126 | Supply only Running capacitor 36 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton | 20 | Each | |
127 | 127 | Supply only Running capacitor 45 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton | 25 | Each | |
128 | 128 | Supply onlyStarting capacitor 100-120 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton | 25 | Each | |
129 | 129 | Supply only Starting capacitor 120-150 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton | 25 | Each | |
130 | 130 | Supply only Starting Relay 1022/ 1622 for Window/Split type AC unit of Cap 1.5 Ton/2 Ton | 30 | Each | |
131 | 131 | Supply only Starting Relay 2000 for Window/Split type AC unit of Cap 1.5 Ton/2 Ton | 25 | Each | |
132 | 132 | Supply only Thermostat switch 2059/2064/2054 for Window/Split type AC unit of Cap 1.5 Ton/2 Ton | 15 | Each | |
133 | 133 | Supply only Lit lawn sheet 6mm thick and 1000 mm wide for Window/Split type AC unit of Cap 1.5 Ton/2 Ton | 20 | RM | |
134 | 134 | Supply only Condenser fan blade for Window Type AC Cap 1.5/2 Ton made of Plastic. | 10 | Each | |
135 | 135 | Supply only Condenser fan blade for split Type A.C Cap 1.5/2Ton made of Plastic. | 10 | Each | |
136 | 136 | Supply only Copper filter double capillary pencil type for Window/Split type AC unit of Cap 1.5 Ton/2 Ton | 10 | Each | |
137 | 137 | Supply only Thermocol sheet 40x20 inch and thickness 20mm for Window/Split type AC unit of Cap 1.5 Ton/2 Ton | 10 | Each | |
138 | 138 | Supply only Wiring kit for A.C Windo/split Type 1.5/2 T | 8 | Each | |
139 | 139 | Supply only Remote control for window type AC Cap 1.5/2 TR of any make as per site requirement. | 5 | Each | |
140 | 140 | Supply only Remote control for split type AC Cap 1.5/2 TR of any make as per site requirement. | 5 | Each | |
141 | 141 | Supply only Main printed circuit board (PCB) with electric accessories and sensors suitable for split type AC capacity 1.5/2 TR. | 4 | Each | |
142 | 142 | Supply only Main printed circuit board (PCB) with electric accessories and sensors suitable for window type AC capacity 1.5/2 TR. | 4 | Each | |
143 | 143 | Supply only Platic louvers for (Front panel) for Window AC 1.5/2 Ton as per existing at site. | 5 | Each | |
144 | 144 | Supply only Selector switch for fan/cooling of Window type AC 1.5/2 Ton | 5 | Each | |
145 | 145 | Supply only Suction and discharge valve set for Split type AC 1.5/2 TR capacity of any make as per exisiting | 5 | Each | |
146 | 146 | Taking down old unserviceable or rusted body and replace it with new body for desert cooler including reconnecting the electric connection and testing complete all as specified and directed by the Engr-in-Charge. | 9 | Each | |
147 | 147 | Disconnecting from the mains and taking out the existing underviceable fan motor of cooler and rewiring the fan motor 1/10 HP capacity 3 speed single phase 240 volts for desert cooler including reconnecting the electric connection and testing complete all as specified and directed by the Engr-in-Charge. | 8 | Each | |
148 | 148 | Note :- Amount of credit of Rs. 94689.00 for retrieved materials is mentioned in Schedule of Credit mentioned in tender documents in pdf form which will be deducted offline while acceptance of tender. |