Providing Laying Jointing Testing Pvc Pipe, Specials For Distribution System, Sluice Valve, Chamber, House Connection For Existing Pipe Line & New Pipe Line, Repair/Replacement Of Pumping Machinery, Control Panel, Repair Of Pump Chamber, Repair Of Ohsr & , Amritsar-Punjab

Water Supply And Sanitation Department-WSSD has published Providing Laying Jointing Testing Pvc Pipe, Specials For Distribution System, Sluice Valve, Chamber, House Connection For Existing Pipe Line & New Pipe Line, Repair/Replacement Of Pumping Machinery, Control Panel, Repair Of Pump Chamber, Repair Of Ohsr & . Submission Date for this Tender is 15-06-2022. Control Panel Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

28120783
Corrigendum : Providing Laying Jointing Testing Pvc Pipe, Specials For Distribution System, Sluice Valve, Chamber, House Connection For Existing Pipe Line & New Pipe Line, Repair/Replacement Of Pumping Machinery, Control Panel, Repair Of Pump Chamber, Repair Of Ohsr &
Open Tender
Indian
Punjab
Amritsar
15-06-2022

Tender Details

Providing Laying jointing testing PVC pipe, specials for Distribution System, Sluice valve, Chamber, House Connection for existing pipe line & new Pipe Line, Repair/Replacement of Pumping Machinery, Control Panel, Repair of Pump Chamber, Repair of OHSR & Development of water works etc. & All other works Contigent there to Complete in all respect at Water Supply Scheme Village Sidhwan, Block Majitha, Distt Amritsar. (Under PRWSSIP Sub Component 2a(i)/JJM)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jun-2021 Corrigendum No. 5799-5829 Dated 15.06.2021 Date 21-06-2021
2 22-Jun-2021 Corrigendum No. 6267-97 Dated 21.06.2021 Date 28-06-2021
3 29-Jun-2021 Corrigendum SPL62-92 Dated 28.06.2021 Date 08-07-2021
4 09-Jul-2021 Corrigendum SPL 62-92 Dated 09.07.2021 Date 19-07-2021
5 20-Jul-2021 Corrigendum No. 6616-46 Dated 19.07.2021 Date 29-07-2021
6 30-Jul-2021 Corrigendum No. 7044-74 Dated 30.07.2021 Date 09-08-2021
7 10-Aug-2021 Corrigendum No. 7480 to 7509 Dated 10.08.2021 Date 17-08-2021
8 18-Aug-2021 Corrigendum No. 7704-34 Dated 18.08.2021 Date 31-08-2021
9 01-Sep-2021 Corrigendum No. 8181-8211 Dated 31.08.2021 Date 09-09-2021
10 10-Sep-2021 Corrigendum No. 8684-8714 Dated 10.09.2021 Date 23-09-2021
11 24-Sep-2021 Corrigendum No. 8956-86 Dated 24.09.2021 Date 12-10-2021
12 13-Oct-2021 Corrigendum No. 9437-67 Dated 13.10.2021 Date 27-10-2021
13 28-Oct-2021 Corrigendum No. 9879-9909 Dated 27.10.2021 Date 08-11-2021
14 09-Nov-2021 Corrigendum No. 14341-71 Dated 08.11.2021 Date 15-11-2021
15 16-Nov-2021 Corrigendum No. 14561-91 Dated 16.11.2021 Date 25-11-2021
16 26-Nov-2021 Corrigendum No. 15107-37 Dated 26.11.2021 Date 02-12-2021
17 03-Dec-2021 Corrigendum No. 15452-15482 Dated 02.12.2021 Date 15-12-2021
18 16-Dec-2021 Corrigendum No. 15835-65 Dated 16.12.2021 Date 20-12-2021
19 21-Dec-2021 Corrigendum No. 17160-90 Dated 21.12.2021 Date 28-12-2021
20 29-Dec-2021 Corrigendum No. 17489-17519 Dated 29.12.2021 Date 06-01-2022
21 07-Jan-2022 Corrigendum No. 249-79 Dated 07.01.2022 Date 11-01-2022
22 12-Jan-2022 Corrigendum No. 452-82 Dated 12.01.2021 Date 18-01-2022
23 19-Jan-2022 Corrigendum no. 845-75 Dated. 19-01-2022 Date 27-01-2022
24 28-Jan-2022 Corrigendum No. 1077-1107 Dated 28.01.2022 Date 23-02-2022
25 24-Feb-2022 corrigendum no 1505-35 dated 24-02-2022 Date 16-03-2022
26 17-Mar-2022 Corrigendum No. 1942-72 Dated 17.03.2022 Date 30-03-2022
27 30-Mar-2022 Corrigendum No. 2650-80 Dated 30.03.2022 Date 21-04-2022
28 22-Apr-2022 Corrigendum No. 605-35 Dated 22.04.2022 Date 09-05-2022
29 10-May-2022 Corrigendum No. 1038-68 Dated 10.05.2022 Date 23-05-2022
30 24-May-2022 Corrigendum no.2256-86 dated. 24-05-2022 Date 01-06-2022
31 02-Jun-2022 corrigendum no. 8941-70 dated 02-06-2022 Date 15-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 10500.0 /-
Tender Value
INR 5.22 Lakhs /-

BOQ Items

Name of Work: Providing Laying jointing testing PVC pipe, specials for Distribution System, Sluice valve, Chamber, House Connection for existing pipe line & new Pipe Line, Repair/Replacement of Pumping Machinery, Control Panel, Repair of Pump Chamber, Repair of OHSR & Development of water works etc. & All other works Contigent there to Complete in all respect at Water Supply Scheme Village Sidhwan, Block Majitha, Distt Amritsar. (Under PRWSSIP Sub Component 2a(i)/JJM)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.\n(Manually excavation and Including specials) BI01010001010000000000000515BI0100001112
2 2 63mm o/d pipe of 6 Kgf. / sqcm BI01010001010000000000000515BI0100001113 375 mtr
3 3 Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).\nClass PN-1 as per ISI BI01010001010000000000000515BI0100001114
4 4 80mm i/d Sluice Valves flanged BI01010001010000000000000515BI0100001115 2 No.
5 5 Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. BI01010001010000000000000515BI0100001116
6 6 Size 0.6 m. x 0.6 m. BI01010001010000000000000515BI0100001117 2 No.
7 7 Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position BI01010001010000000000000515BI0100001118
8 8 63mm pipe Dia BI01010001010000000000000515BI0100001119 350 mtr
9 9 Dismantling of metalled road with Bithminous course 50 to 75 mm thick with base course and making good the same to its original condition as per analysis. BI01010001010000000000000515BI0100001120 25 mtr
10 10 Providing proposed water connection to house hold up to wall with providing, laying jointing testing MDPE pipe lines 15 mm i/d with specials 2.00 mtr (Below GL) and ISI Marked G.I. pipe 15 mm i/d GM ferrule (As per IS:1239) B Class approved make2.50 mtr. (Above GL) including cost of special such as tees, bends, sockets, elbow, etc. cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with C.I bib cock, 15 mm i/d as per IS: 210 with stainless steel spindle of approved make as per CSR 30.65 (b) complete in all respects.\n(Connection at Existing pipe line) 60\n(Connection at New pipe line) 15 BI01010001010000000000000515BI0100001121 75 No.
11 11 Cost of Replacement of Machinery Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 142 LPM against a head of 65 mtr (reputed make) complete in all respects as per standard Specifications including Cable as per standard Specifications. BI01010001010000000000000515BI0100001122 1 Job
12 12 Cost of Replacement of control panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. (reputed make) complete in all respects as per standard Specifications. BI01010001010000000000000515BI0100001123 1 Job
13 13 Repair of Pump Chamber BI01010001010000000000000515BI0100001124
14 14 Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. (Grills in windows, Grills in ventilator, R.S. Joint on roof, Door, Ventilator,Windows .etc) BI01010001010000000000000515BI0100001125 23.85 Sqm
15 15 White washing 3 coats inside of pump chamber. BI01010001010000000000000515BI0100001126 13.08 Sqm
16 16 Finishing walls with cement based water soluble exterior paint such as snowecem, robbiacem etc. on old work one coat to give an even shade. BI01010001010000000000000515BI0100001127 73.31 Sqm
17 17 Repair of 12.5mm thick cement plaster 1:4 complete in all respects. BI01010001010000000000000515BI0100001128 33.6 Sqm
18 18 Conglomerate floor 50mm thick cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling. using mechanical mixer for mixing of material BI01010001010000000000000515BI0100001129 15.91 Sqm
19 19 Repair of Existing windows including replacing old chowkat and shutter .etc complete in all respects. BI01010001010000000000000515BI0100001130 1 Job
20 20 Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.\nGlass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area BI01010001010000000000000515BI0100001131 6.9 Sqm
21 21 RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- BI01010001010000000000000515BI0100001132
22 22 Wiring fan point (Without fan box) BI01010001010000000000000515BI0100001133 1 No.
23 23 Wiring light point BI01010001010000000000000515BI0100001134 3 No.
24 24 Wiring 6Amp. Plug control comprising wall socket point BI01010001010000000000000515BI0100001135 2 No.
25 25 Wiring 16/20Amp. power plug control point BI01010001010000000000000515BI0100001136 1 No.
26 26 Providing and fixing of ceiling fan of reputed make such as Crompton or equivalent BI01010001010000000000000515BI0100001137 1 No.
27 27 Providing and fixing of electric tube set of reputed make BI01010001010000000000000515BI0100001138 1 No.
28 28 Repair of OHSR BI01010001010000000000000515BI0100001139
29 29 Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects. BI01010001010000000000000515BI0100001140 1 Job
30 30 Repair of 4" Expansion joint Complete in all respects. BI01010001010000000000000515BI0100001141 3 No.
31 31 OHSR Plinth Protection BI01010001010000000000000515BI0100001142
32 32 Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. BI01010001010000000000000515BI0100001143 3.54 Cum
33 33 Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type BI01010001010000000000000515BI0100001144 1.15 Cum
34 34 First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth BI01010001010000000000000515BI0100001145 2.62 Cum
35 35 12.5 mm thick cement plaster 1:4 BI01010001010000000000000515BI0100001146 8.86 Sqm
36 36 Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres BI01010001010000000000000515BI0100001147 5.7 Cum
37 37 Stone (building or pitching) Sand, Earth, Fly Ash, Bajri, Shingle, Spalls, Brick bats, Brick ballast and Stone metal. BI01010001010000000000000515BI0100001148 2.16 Cum
38 38 Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type BI01010001010000000000000515BI0100001149 2.04 Cum
39 39 Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material BI01010001010000000000000515BI0100001150 24.2 Sqm
40 40 Finishing wall with cement based water soluble exterior paint such as snowcem robbiacem etc. on new work in two coats to give even shade. BI01010001010000000000000515BI0100001151 5.23 Sqm
41 41 Development of water works BI01010001010000000000000515BI0100001152
42 42 Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing. BI01010001010000000000000515BI0100001153 170 mtr
43 43 Providing & Fixing D hook complete with MS bolt size 300 mm x18 mm as per standard drawing D-7 & Analysis of Rates A-9 complete in all respects. BI01010001010000000000000515BI0100001154 24 No.
44 44 Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects including carriage. BI01010001010000000000000515BI0100001155 35 No.
45 45 Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3. BI01010001010000000000000515BI0100001156 4 No.
46 46 Construction of foot paths with masonry toe wall& earth filling & concrete topping; inside water works as per standard drawing D-10 & Analysis of Rates A-11 complete in all respects. BI01010001010000000000000515BI0100001157 37 mtr
47 47 Repair gate pillar & Gate Painting two coats including priming coat with ready mixed paint for metallic surface in all shades on new steel or iron work. BI01010001010000000000000515BI0100001158 1 No.
48 48 Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing D-20 BI01010001010000000000000515BI0100001159 1 No.
49 49 Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications. BI01010001010000000000000515BI0100001160 1 Job
50 50 Extra Carriage of Sand (Fine Aggregate) BI01010001010000000000000515BI0100001161 15.92 Cum
51 51 Extra Carriage of Bajri (Course Agrregate) BI01010001010000000000000515BI0100001162 17.99 Cum
Disclaimer :