Military Engineer Services-MES has published Periodical Services To Compound Wall Including Painting To Street Poles And Allied Street Light Works At Arakkonam. Submission Date for this Tender is 24-06-2021. Electrification Work Tenders in Arakkonam Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

28101557
Corrigendum : Periodical Services To Compound Wall Including Painting To Street Poles And Allied Street Light Works At Arakkonam
Open Tender
Indian
Tamil Nadu
Arakkonam
24-06-2021

Tender Details

Periodical Services To Compound Wall Including Painting To Street Poles And Allied Street Light Works At Arakkonam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jun-2021 BoQ Corrigendum BOQ 24-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PERIODICAL SERVICES TO COMPOUND WALL INCLUDING PAINTING TO STREET POLES AND ALLIED STREET LIGHT WORKS AT ARAKKONAM (TENDER ID : 2021_MES_448773_1)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Cutting bushes, weed, trees and stems of trees including cutting down tress upto 30cms girth and stacking of serviceable material and disposal of rubbish material to a distance not exc 50m from site and clear for access the compound wall (1m from edge of compound wall) for colour washing etc., complete all as specified and as directed. 15000 Sqm
2 2 Material and labour for preparing old decorated surfaces of walls and applying one coat of colour wash complete all as specified and as directed. 61750 Sqm
3 3 Materiala and labour for preparing old decorated surfaces of walls and applying one coat of cement wash with portland cement slurry to smooth bodied opaque finish wall complete all as specified and as directed. 6175 Sqm
4 4 Material and labour for preparation of old painted steel surfaces of any description exc 10cm width (or) girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 500 Sqm
5 5 Material and labour for preparation of old painted wooden surfaces of any description exc 10cm width (or) girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 50 Sqm
6 6 Material and labour for preparing old painted decorated wall surfaces and applying one coat of white wash complete all as specified and as directed. 1000 Sqm
7 7 Material and labour for preparing old painted decorated ceiling surfaces and applying one coat of white wash complete all as specified and as directed. 1100 Sqm
8 8 Material and labour for preparing old painted decorated wall surfaces and applying one coat of cement base paint complete all as specified and as directed. 5600 Sqm
9 9 Material and labour for preparing old painted decorated wall surfaces and applying one coat of acrylic emulsion paint (Matt finish) surfaces of walls and over projected surfaces of parapet/ column/ beams/ facia of chajjas complete all as specified and as directed. 500 Sqm
10 10 Taking down cement plaster on brick or stone walls etc., including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and as directed. 150 Sqm
11 11 Material and labour for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 complete all as specified and as directed. 300 Sqm
12 12 Material and labour for preparation of newly plastered surfaces of wall and applying two coats of colour wash etc., complete all as specified and as directed. 300 Sqm
13 13 Racking out joints/ pointing to square rubble masonary coursed or uncoursed and brought upto course work built in cement mortar complete all as specified and as directed. 250 10 sqm
14 14 Material and labour for keyed pointing to random rubble masonry brought upto courses in CM 1:4 complete all as specified and as directed. 450 10 sqm
15 15 Demolition of stone masonry built in cement mortar including all quoins, arches, etc., including dressed stone work complete all as specified and as directed. 44 Cum
16 16 Material and labour for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in with cement mortar 1:4 complete all as specified and as directed. 9 Cum
17 17 Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and as directed. 30 Cum
18 18 All as per item No.16 here-in-before but except stone. 5 Cum
19 19 Material and labour for cement concrete type D2 1:4:8, (Using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and as directed. 1.5 Cum
20 20 Supply and fix in repairs galvanised iron, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and pran of glavanished mild steel wire, staples or steel pins etc., (each line of wire to be measured) complete all as specified and as directed. 90 100 RM
21 21 Supply and fix in repairs 600mm dia razor blade galvanised barbed concertina coil having minimum weight of 8Kg (+) or (-) 5% per coil of 2.6mm dia wire streched to a length of 5m to 6m as in fencing to steel posts and to another coil/ MS nibs including fixing with special galvanised fasterners such as J clips, C clips, U clips complete all as specified and as directed.\nNote: After streching the coil, the length of the compound wall on which it has been streched shall be considered for measurement. 450 RM
22 22 Supply and fix in repairs 1050mm dia razor blade galvanised barbed concertina coil having minimum weight of 15Kg (+) or (-) 5% per coil of 2.6mm dia wire streched to a length of 6m to 8m as in fencing to steel posts and to another coil/ MS nibs including fixing with special galvanised fasterners such as J clips, C clips, U clips complete all as specified and as directed.\nNote: After streching the coil, the length of the compound wall on which it has been streched shall be considered for measurement. 450 RM
23 23 Dismantling wrought iron or mild steel work of any description complete all as specified and as directed by Engr-in-charge. 3.5 Qtl
24 24 Supply and fix for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.,) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. 350 Kg
25 25 Material and labour for preparation of new steel surfaces of any description exc 10cm width (or) girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directe. 50 Sqm
26 26 Material and labour for painting to existing LT street light tubular poles of following sizes including bracket of street light bracket and other accessories as per site requitrement after preparing/ scraping the metal surface with emery sheet in all respect for making smooth surface and painted with one coat coat of aluminium paint including writing pole No/ feeder No and supply and fix of superior quality self adhesive water proof photo reflective tape in two lines on poles as directed (tape size and tint shall be as approved by Department) as per site requirement complete all as specified as directed.\nNote: The bottom of pole 1.5m height above coping shall be painted with light blue paint and aluminium paint strips alternatively at an interval of 30cm including writing the pole with white colour over black colour circle base all as per site.
27 26.01 9.0 Mtr to 10.0 Mtr long 180 Each Job
28 26.02 11.0 Mtr to 12.0 Mtr long 120 Each Job
29 27 Supply and fix including fabrication of cable route indicator consisting of cast iron shape 200mm dia, 12mm thick with inscription embossing as LT cable and fixed hot dipped GI angle iron of size 50x50x6mm thick 0.8m long and GI nuts and bolts embadded in ground including PCC 1:3:6 type C-1 (Using 20mm graded stone aggregrade) as in PCC block of size 200x200x500mm complete all as specified and as directed. 20 Each
30 28 Material and labour for taking out of existing loop cable from under ground, after rectificattion of fault /damaged cable portion and relaying the cable to same existing location with proper connections including lugs, nuts, bolts including PCC works, necessary earth works etc., complete all as specified and as directed. 40 Each Job
31 29 Taking up existing old/ unserviceable/ burnt under ground cable from the existing positions/ trenches etc., including testing with the help of megger, disconnecting and removing unserviceable portion of cable complete all as specified and as directed by Engr-in-charge.\nNote: (i) Excavation/ earth work shall be measured and paid seprately under relavent items.\n(ii) Retrived good bricks and sand from site properly stacked and reused as protection to UG cable.\n(iii) Serviceable portion of cable shall be relayed as directed and shall be measured and paid separetely under relevent items.
32 29.01 25 sqmm 2 core to 50 sqmm 3.5 / 4 core. 400 Running Metre
33 29.02 10 sqmm 2 core to 16 sqmm 2 core 500 Running Metre
34 30 Laying only serviceable portion of cable as obtained against item No 11 here-in-before in the trench suitable for site requirement and for necessary connections with suitable lugs complete all as specified and directed by Engr-in-charge.\nNote: Cable straight through joints/ bus bar chamber if any as per site requirement shall be measured and paid seprately under relevent item of schedule.
35 30.01 25 sqmm 2 core to 50 sqmm 3.5 / 4 core. 50 Running Metre
36 30.02 10 sqmm 2 core to 16 sqmm 2 core 50 Running Metre
37 31 Supply, laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor of following size for replacement of unserviceable portion of cable including connecting up with proper size aluminium lugs, glands wherever necessary in LT panels/ bus bar chamber panel /joints etc., all as per site requirement including testing complete all as specified and as directed \nNote: (i) Rates includes supply and fix necessary glands, lugs, etc.,.\n(ii) Excavation/ Earth work shall be measured and paid separately under relevent items.\n(iii) Cable straight through joints/ bus bar chamber if any as per site requirement shall be measured and paid seprately under relevent item of schedule.
38 31.01 50 sqmm 3.5 core 175 Running Metre
39 31.02 25 sqmm 4 core 175 Running Metre
40 31.03 16 sqmm 4 core 450 Running Metre
41 32 Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for taking out cables /pipes /poles /stay /route indicators etc., and getting out in soft /loose soil complete all as specified and as directed. 230 Cum
42 33 Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cms complete all as specified and as directed. 138 Cum
43 34 Removing excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed. 92 Cum
44 35 Relaying of reusable bricks as obtained from item No.01 here-in-before complete all as specified and as directed. 2 Per 1000 Nos
45 36 Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and as directed. 5 Per 1000 Nos
46 37 Spreading riddled earth as obtained from item No. 01 here-in-before in cable trenches complete all as specified and as directed.\nNote: If required Qty not obtained from item No. 32 the contractor should make brought up pit in the location not exceeding 50m distance to avail required qty and the cost for necessary earth work is deemed to be included in the quoted rate. 70 Cum
47 38 Material and labour for PCC for coping round/ cylindrical type for existing poles whereever necessary, 1:3:6 type C-1 (Using 20mm graded stone aggregate) complete all as specified and as directed. 1 Cum
48 39 Material and labour for PCC for foundation for existing poles whereever necessary, cable route indicators etc., 1:4:8 type D-2 (Using 40mm graded stone aggregate) complete all as specified and as directed. 1 Cum
49 40 Demolition and dismantling of damaged concrete of any description from existing poles etc., complete all as specified and as directed. 1 Cum
50 41 Supply, fixing and testing powder coated outdoor street light control box of size not less than 300x200x80mm CRCA 3mm thick IP 55 fabricated by CPRI certified panel manufacturer's in and including suitable terminal TPN 10 KA SMC connector (Make - Electro Fibres / Powermat / Ramanuj for 3 phase cable line IN and OUT), MCB 6 SP Amps - 02 Nos, canopy weather proof, hinged door with two hinges, pad side locking system - 02 Nos (top and bottom), for fixing on PCC / steel poles in and including MS clamps - 02 Nos of suitable shape of size 40x5mm with zinc coated nuts, bolts and washers as per site requirement complete all as specified and as directed.\nNote: (i) The cost deemed to be included in the quoted rate for reconnecting old existing cables to boxes carefully using a suitable glands and also taking up loop from the under ground and making good in all respect whereever required as per site requirement. 20 Each
51 42 Supply, draw /connect, testing weather proof PVC insulated multi stranded copper conductor 2.5 sqmm round, three core 1100 volts grade complete all as specified and as directed 400 Running Metre
52 43 Supply, fixing and testing LED street light luminaire fitting not less than 60 Watt and not less than IP 65 protection comprises of pressure die cast aluminium housing powder coated, with luminaire efficiancy not less than 100 lm/w provided with surge suppressor 5 KV complete including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed.\nMake: Surya Roshini Ltd Cat Part No. SLE UL 60W IP66 LXN /Philips /Wipro /Havells /Crompton/ Luker Electric Technologies Pvt Ltd\nNotes: (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement \n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. 24 Each
53 44 Supply, fixing and testing LED street light luminaire fitting of not less than 45 Watt and not less than IP 65 protection comprises of Pressure die cast Aluminium housing powder coated, with luminaire efficiancy not less than 100 lm/w provided with surge suppressor 5 KV complete including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed.\nMake: Surya Roshini Ltd Cat Part No. SLE UL 45W IP66 LXN/ Philips /Wipro /Havells /Crompton/ Luker Electric Technologies Pvt Ltd\nNotes: (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement.\n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. 30 Each
54 45 Supply, fixing and testing LED flood light fitting of not less than 100 Watt and not less than IP 65 protection comprises of pressure die cast aluminium housing powder coated, toughened glass, luminaire efficiancy not less than 100 lm/w provided with surge suppressor 10 KV including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed.\nMake: Surya Roshini Ltd Cat Part No. SLE FL 100W IP66 LUMOS/ Philips /Wipro /Havells /Crompton/ Luker Electric Technologies Pvt Ltd \nNotes: (i) Quoted rate is deemed to be included of necessary Ladder, tools and plants, necessary drilling, bolts /screws and MS frame work if any for fixing new one etc., as per site requirement. \n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. 10 Each
55 46 Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out in soft / loose soit including removing green vegetation, roots, bushes etc from surroundings near electric poles/panels or sub stations area Complete all as specified and directed. 80 Sqm
56 47 Cutting and Trimming of tree branches touching street / security poles or light fittings etc, to clear the tree branches around the pole and maintain a clearance of 1.50 M radius of the pole top or light fitting complete all as specified and as directed.\nNote: (a) An area of 1.5 M surrounding the pole to be cleared off trees branches. \n(b) Measurement and payment will be made for all cutting / trimming near top of the each pole as one job only. 50 Each Job
57 48 Supply, fixing and testing LED post top 40 Watt high output with single piece construction comprises of die cast housing and clear acrylic and spun aluminium reflector, IP-65 protection lighting luminaire, including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed. \nNote: (i) Quoted rate is deemed to be included the charges of necessary ladder, tools and plants, necessary drilling, bolts/ screws for fixing new one etc., as per site requirement \n(ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer. 8 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail