}

Pumping Machinery Installation, Repairing And Maintenance Supplying Of Spare Part At Raw And Pure Water Pumping Station. ( 2 Nd Call ) -1 Latur City Water supply Project Dhanegaon head works (ManjaraProject) Vt PumpHead- 77metre.Dischange- 0473 L, Latur City Municipal Corporation, Latur-Maharashtra

Latur Municipal Corporation has published Pumping Machinery Installation, Repairing And Maintenance Supplying Of Spare Part At Raw And Pure Water Pumping Station. ( 2 Nd Call ) -1 Latur City Water supply Project Dhanegaon head works (ManjaraProject) Vt PumpHead- 77metre.Dischange- 0473 L. Submission Date for this Tender is 21-06-2021. Spare Part Tenders in Latur City Municipal Corporation, Latur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

28079511
Corrigendum : Pumping Machinery Installation, Repairing And Maintenance Supplying Of Spare Part At Raw And Pure Water Pumping Station. ( 2 Nd Call ) -1 Latur City Water supply Project Dhanegaon head works (ManjaraProject) Vt PumpHead- 77metre.Dischange- 0473 L
Indian
Maharashtra
Latur City Municipal Corporation, Latur
21-06-2021

Tender Details

Pumping Machinery Installation, Repairing And Maintenance Supplying Of Spare Part At Raw And Pure Water Pumping Station. ( 2 Nd Call ) -1 Latur City Water supply Project Dhanegaon head works (ManjaraProject) Vt PumpHead- 77metre.Dischange- 0473 LPS/ 1703m3/ hr ( 17,03,000lph)Model -C24TCStages- 2, MakeWPIL, Speed - 1180 rpm. Reparingwith Bearing shaft sleavesbussypumpoil,oilchemberbushingTTPlatebush,gland with dismentling, erecting labour charges. 2 10MTCapacityEOTCranewithelectricallyoperated, CPblock and travelling Trolley lift - 10 m., Span - 11.5 mtr. Make - Hercules, starter, contactswithsupplying, erectingwithlabour Charges. 3 3.3KVVSSMotor (SPDP)Speed- 1500rpm.KW- 510,Current - 109A. HP- 700HPmake- alstomrotorbrsig,windingbearings with repairing and rewinding, dismentling, erecting labour charges. 4 Repairingand rewindingof Transformer 33 KV/ 3.3 KVwith OLTC,RTCC,AVRandMarshallingboxcapacity- 2500KVAmake Transdelta (Aurangabad) 5 Repairingandrewinding AuxiliaryTransformer (ForL.T. Supply) 3.3 KV / 0.433 KV Capacity - 100 KVA make - Transdelta. 6 Repairing/ replacementofHTSubstationwith33KV,ABswitch, lighting arrestor, disc insulator, pin insulator etc. 7 Repairing/ replacement 33KVindoor VCBpanel insubstation room33KVfullydrawout typevacuumcircuit beaker630AMP CapacitywithCTsRatio- 75/ 5AandPTSratio33KV/ 110V/ 100 VA Burden / TPIDMTL - relay, HT fiber size vaccum contractor, duck, insulator, mail, femail contact. 8 Repairingof 3.3KVVCBandisolator panel insubstationroom 800 A - 3.3 KV VCB Panel. 9 Repairing of 3.3 KV break switch panel 10 Repairing/ replacement of 3.3KV- 100KVARCapacitor bank, transformer, reactor, etc. 11 3.3 KVVCB800 Afor Buscoupler, repair withmaterial with labour 12 Repairing/ replacementof3.3KV400AVaccumcontractorsfor motor feeder, contacts, fuse 200 amp. 13 Repairing/ replacementof3.3KV200AbreakerswitchwithHRC Fuses, coil, contacts, necessary material 14 Repairing/ replacement of LTPanel Board630A- Air Circuit breaker,contacts coil, mechanical work 15 Supplyingand erectingof Power Cables33 KV, 3 core x 185 sqmmXLPE(E) grade aluminiumConductor armoured cable (from two pote to VCB, VCB to transformer) 16 Supplyinganderectingof 11KV, 3 core x120 sqmmXLPE(E) grade Aluminium Conductor armoured cable (Motor Control panel to motor) 17 Supplyinganderectingof 11KV, 3 core x300 sqmmXLPE(E) grade Aluminium Conductor armoured cable (2500 KVA Transformer to motor feeder panel) 18 Supplyinganderectingof 3 1/2Core x240 sqmmaluminium armoured cable (For auxiliary and LT Panel Board) 19 Supplying and erecting of Control Cable 10 Core x 2.5 sq.mm 20 Supplying and erecting of 7 Core x 1.5 sq.mm 21 Supplying and erecting of 4 Core x 1.5 sq.mm 22 Supplying and erecting of 4 Core x 2.5 sq.mm 23 Supplying and erecting of 2 Core x 1.5 sq.mm 24 Supplying and erecting of 10 Core x 1.5 sq.mm 25 Repairing of HT Capacitors 3.3 KV make madhavKVAR 100 26 PureWaterPumpingStationat HarangulWTP VTPumpHead 67meterDischange1123m3/ hr (11,23,000LPH)Speed- 1480 rpmModelStages- 2MakeWPILshaft sleaves, bearing, rubber packing,TTplatebushing,nutbolt,oil,grease withdismentling, erecting labour charges. 27 Removing, Dismentling of 700 HP Electrical Motor 28 Removing, Dismentling of 442 HP Electrical Motor 29 Removing, Dismentling of 700 HP Pump Set 30 Removing, Dismentling of 442 HP Pump Set 31 Motor / pump fitting and erecting loading and unloading transportation 32 7.5MTCapacityEOTCrane,CPblockandtravellingTrolleylift -8 m, span 11.5 mtr make hercules starter moter, repairing, rewinding with material. 33 3.3KVVSSMotor (SPDP)Speed- 1500rpm.KW- 330,Current - 72A. HP- 442HPmake- alstomRewinding, repairsworkwith bearing breazing. 34 Rewinding, repairingof Transformer 33KV/ 3.3KVwithOLTC, RTCC, AVRand Marshalling box capacity - 1600 KVAmake Transdelta, transfor fress oil, Breather. 35 Repairingof Auxiliary Transformer (For L.T. Supply) 3.3 KV / 0.433KVCapacity- 315KVAmake- Transdelta.Repairingwork with T/f Fresh Oil 36 Repairing andmaintenance of HT Substation with 33 KVAB switch, lighting arrestor, disc insulator, pin insulator cunductor. 37 Repairingof 33KVVCB_630AMPfor Isolationof 3.3KVSupply, repair with material 38 Repairingof 3.3KVVCBandIsolator panel insubstationroom 800 A - 3.3 KV VCB Panel repair with material 39 Repairingof 3.3KV- 100KVARCapacitorbank, transform, fuse, capacitor, supply and repair 40 Supplying and erecting of 125 A TP SFU H.T. Fuses 41 Supplying and erecting of 63 A TP SFU H.T. Fuses 42 Supplying and erecting of 100 A TP SFU H.T. Fuses 43 Supplying and erecting of 250 A TP SFU H.T. Fuses 44 Cable trays of Iron works 45 Repairing of UPS System 3 KVA Capacity 3 KVA Battery panel 46 Repairing / replacement of Battery 12 volts Exide Make 47 Electrification, bulb, metering, led, unit 48 Fire Fighting and safety equipments 49 Tools - Plyer, cutter, spaner set, ring spaner set 50 Earthing 51 हहहह ऀऀऀऀऀऀऀऀ ऀ य य यय यय य यय य ऀऀऀऀ 50 HP Wash Water Electric Motor and centrifugal pump repair, rewinding with bearing cupler. 52 Air Blower 50 HP Electric Motor Repairing, rewinding with material, bearing, oil, grease, V Belt. 53 Repairing of Non Return Valve size 450 mm dia 54 Repairing of Non Return Valve size 600 mm dia 55 Supplying and erecting 63 Amper MCCB 56 Supplying and erecting 100 Amper MCCB 57 Supplying and erecting 200 Amper MCCB 58 Supplying and erecting 250 Amper MCCB 59 Supplying and erecting 400 Amper MCCB 60 Supplying and erecting 630 Amper MCCB 61 Supplying and erecting LT Contractor of verious size as below 100 Amper 62 125 Amper 63 185 Amper 64 225Amper 65 330 Amper 66 400 Amper 67 630 Amper 68 C.T. Relay 63 Amper 69 125 Amper 70 150 Amper 71 225 Amper 72 330 Amper 73 630 Amper 74 Vaccume timer 75 L.T. single phase privater 76 ATS Rewinding for 50 HP 77 ATS Rewinding for 75 HP 78 ATS Rewinding for 150 HP 79 ATS Rewinding for 250 HP 80 Gear Box repairing work with gear oil bearing. 81 Electric Motor Rewinding with Material 1 HP 82 Electric Motor Rewinding with Material 2 HP 83 Electric Motor Rewinding with Material 3 HP 84 Electric Motor Rewinding with Material 5 HP 85 Electric Motor Rewinding with Material 25 HP 86 Electric Motor Rewinding with Material 50 HP 87 Electric Motor Rewinding with Material 75 HP 88 Electric Motor Rewinding with Material 150 HP 89 Electric Motor Rewinding with Material 250 HP 90 Submersible Monoblock pumpset rewinding repairing bush bearing set empler shaft for 3 HP 91 5 HP 92 7.5 HP 93 10 HP 94 15 HP 95 75 HP 96 L.T. Panel Board Indicator Ammter, Voltmeter, selector switch push button on / off CT (25/5, 100/5 Amper 200/5 Amper, 600/5 Amper 97 Sluice Value Repair size 80 mm dia Check Nut 98 Spendal Rod 99 Joint Rassi 100 Nut Bolt 101 Gland Cap 102 Supplying of Grease 103 Supplying of Gear Oil 104 Sluice Value Repair size 100 mm dia Check Nut 105 Spendal Rod 106 Joint Rassi 107 Nut Bolt 108 Gland Cap 109 Sluice Value Repair size 150 mm dia Check Nut 110 Spendal Rod 111 Joint Rassi 112 Nut Bolt 113 Gland Cap 114 Sluice Value Repair size 200 mm dia Check Nut 115 Spendal Rod 116 Joint Rassi 117 Nut Bolt 118 Gland Cap 119 Sluice Value Repair size 250 mm dia Check Nut 120 Spendal Rod 121 Joint Rassi 122 Nut Bolt 123 Gland Cap 124 Sluice Value Repair size 300 mm dia Check Nut 125 Spendal Rod 126 Joint Rassi 127 Nut Bolt 128 Gland Cap 129 Sluice Value Repair size 350 mm dia Check Nut 130 Spendal Rod 131 Joint Rassi 132 Nut Bolt 133 Gland Cap 134 Sluice Value Repair size 400 mm dia Check Nut 135 Spendal Rod 136 Joint Rassi 137 Nut Bolt 138 Gland Cap 139 Sluice Value Repair size 500 mm dia Check Nut 140 Spendal Rod 141 Joint Rassi 142 Nut Bolt 143 Gland Cap 144 Sluice Value Repair size 600 mm dia Check Nut 145 Spendal Rod 146 Joint Rassi 147 Nut Bolt 148 Gland Cap 149 LaturCityWatersupplyProjectDhanegaonDamandpurewater pumping station at Harangul resin cost indoor single phase Doublecorectsupplyinganderectingof33KV15VAclass1/ 10- P-10 150 Resingcost indoor singlecorePTsupplyinganderectingof 100 VA Capacity 33 KV / 3 / 110 volt / 3 Make Hupen 151 Indoor type termination Kit supplying and erecting For 33 KV (E) X LPE unscreened 3 core x 95 sqmm power cable 152 Indoor type termination Kit supplying and erecting For 33 KV (E) X LPE unscreened 3 core x 120 sqmm power cable 153 Indoor type termination Kit supplying and erecting For 33 KV (E) X LPE unscreened 3 core x 185 sqmm power cable 154 OutdoortypeterminationKitsupplyinganderectingfor3.3/ 6.6 KVXLPE (E) unscrened 3 core cable Size 300 sqmm 155 OutdoortypeterminationKitsupplyinganderectingfor3.3/ 6.6 KVXLPE (E) unscrened 3 core cable Size 400 sqmm 156 Supplyinganderectingof Aluminiumlugssuitable for 33.0KV XLPE (E) unscrened 3 core cable Size 185 sqmm 157 25 sqmm Aluminium Cable Lugs 158 50 sqmm Aluminium Cable Lugs 159 95 sqmm Aluminium Cable Lugs 160 95 sqmm Copper Cable Lugs 161 120 sqmm Aluminium Cable Lugs 162 300 sqmm Aluminium Cable Lugs 163 400 sqmm Aluminium Cable Lugs 164 SupplyinganderectingofResincast indoor singlephasedouble coreCTRatio75/5.5Amp33KV100VAClass/ 10-p-10made hupen 165 Supplying and erecting of HT Fiber sheet (as per sample) 166 Supplying and erecting of HT C type fiber sheet (as per sample) 167 Supplying and erecting of HT Tubler type fuses 63 amp 168 Supplying and erecting of 100 amp HT Tubler type fuses 169 Supplying and erecting of 200 amp HT Tubler type fuses 170 Supplying of of DO Fuses 171 Supplying and erecting of Chlorinater 900 KG tonner 172 Alum Grade 1 173 Bleaching Powder Grade 1 ISI Mark, IS-1065 174 PAC Powder 25 Kg bag 175 Aluminium Hydralic 176 Electrical, Mechanical Engineer 177 Supervisor (Electrical / Mechanical) 178 Electrician (ITI Passed) 179 Pump Operator (ITI Passed) (Electrical) 180 Filter Operator (any graduate) 181 Fitter (ITI) 182 Labour (Unscheled)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jun-2021 Bid Submission Date Extended Date 21-06-2021

Key Value

Document Fees
INR 10000 /-
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail