Providing Fixing Pvc Wall Paneling And Portico Work, ARIES Manora Peak, Nainital-Uttarakhand

Aryabhatta Research Institute Of Observational Sciences -ARIES has published Providing Fixing Pvc Wall Paneling And Portico Work. Submission Date for this Tender is 28-06-2021. Composite Panel Tenders in ARIES Manora Peak, Nainital Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

28074771
Providing Fixing Pvc Wall Paneling And Portico Work
Open Tender
Indian
Uttarakhand
ARIES Manora Peak, Nainital
28-06-2021

Tender Details

Providing Fixing Pvc Wall Paneling And Portico Work , Lp / F Pvc Wall Paneling Work In Office Buildings Room And Portico Work In Front Of Auditorium At Manora Peack Aries . Nainital , Providing And Fixing In Wall Lining Medium Density Fiber Board Is: 14587:1998 Marked , Pre-Laminated One Side Decorative Lamination And Other Side Balancing Lamination , With Necessary Fixing Arrangement And Screws Etc . Complete . 12 Mm Thick . , Design Supply & Installation Of Suspended Spider Glazing System Designed To Withstand The Wind Pressure As Per Is 875 ( Part-Iii ) . The Suspended System Held With Spider Fittings Of Ss-316 Grade Steel Of Approved Manufacturer With Glass Panel Having 12 Mm Thick Clear Toughened Glass Held Together With Ss- 316 Grade Stainless Steel Spider & Bolt Assembly With Laminated Glass Fins 21 Mm Thick . The Glass Fins And Glass Panel Assembly Shall Be Connected To Slab / Beams By Means Of Ss- 316 Grade Stainless Steel Brackets & Anchor Bolts And At The Bottom Using Ss Channel Of 50X25x2mm Using Fastener & Anchor Bolts , Non Staining Weather Sealants Of Approved Make , Teflon / Nylon Bushes And Separators To Prevent Bi-Metallic Contacts , All Complete To Perform As Per Specification And Approved Drawings . The Complete System To Be Designed To Accommodate Thermal Expansion & Seismic Movements Etc . The Joints Between Glass Panels ( 6 To 8 Mm ) And Gaps At The Perimeter & In U Channel Of The Assembly To Be Filled With Non-Staining Weather Sealant , So As To Make The Entire System Fully Water Proof & Dust Proof . The Rate Shall Include All Design , Engineering And Shop Drawing Including Approval From Structural Designer , Labour , T&P , Scaffolding , Other Incidental Charges Including Wastage , Enabling Temporary Services All Fitting Fixers Nut Bolts , Washer , Buffer Plates , Fastener , Anchors , Ss Channel Laminated Glass Etc . All Complete . For The Purpose Of Payment , Actual Elevation Area Of Glazing Including Thickness Of Joints And The Portion Of Glass Panel Inside The Ss Channel Shall Be Measured .

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: P/F PVC wall paneling work in Office Buildings Room and portico work in front of Auditorium at Manora Peack ARIES. Nainital
Sl. No. Item Description Item Code / Make Quantity Units
1 1 LP/F PVC wall paneling work in Office Buildings Room and portico work in front of Auditorium at Manora Peack ARIES. Nainital BI01010001010000000000000515BI0100001112
2 1.01 Providing and fixing in wall lining medium density fiber board IS: 14587:1998 marked, Pre-laminated one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. complete. 12 mm thick. BI01010001010000000000000515BI0100001113 2600 sqm
3 1.02 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between\nglass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non-staining weather sealant, so as\nto make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener,\nanchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS\nchannel shall be measured.\n BI01010001010000000000000515BI0100001114 113 sqm