Military Engineer Services-MES has published Provn Of Covid Segregation Clinic And Sanitation Facility At Command Hospital ( Nc ) Under Ge ( North ) Udhampur. Submission Date for this Tender is 30-06-2021. Healthcare Centers and Medical Practice Tenders in UDHAMPUR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

28058634
Corrigendum : Provn Of Covid Segregation Clinic And Sanitation Facility At Command Hospital ( Nc ) Under Ge ( North ) Udhampur
Open Tender
Indian
Jammu And Kashmir
UDHAMPUR
30-06-2021

Tender Details

Provn Of Covid Segregation Clinic And Sanitation Facility At Command Hospital ( Nc ) Under Ge ( North ) Udhampur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jun-2021 Corrigendum 1 Date 23-06-2021
2 16-Jun-2021 Amendment to tender documents and Revised BOQ BOQ 23-06-2021
3 23-Jun-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: PROVN OF COVID SEGREGATION CLINIC AND SANITATION FACILITY AT COMMAND HOSPITAL (NC) UNDER GE(NORTH) UDHAMPUR
Ser. No. Item Description Item Code / Make Quantity Units
1 1 Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in any type of soil, complete all as specified and as directed by Engr-in-Charge. 1 176 Cubic metre
2 2 Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge. 2 109 Cubic metre
3 3 Removal of excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point , complete all as specified and as directed by Engr-in-Charge. 3 67 Cubic metre
4 4 Plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foudation, filling, sub base and mass concrete all as specified. 4 14.8 Cubic metre
5 5 75mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engr-in- Charge. 24 Running metre
6 6 Walling of random rubble stone masonry uncoursed, with best quality locally available harder stones such as granite, trap, basalt, trap, basalt stone etc, well bonded, bedded and solidly hearted , built in cement mortar 1:6 complete all as specified and as directed. 6 20 Cubic metre
7 7 Flush pointing to random or polygonal rubble stone Masonry, uncoursed or brought upto courses, in cement mortar 1:4 complete all as specified and as directed by Engr-in-Charge. 5 Ten Square Metre
8 8 Plain cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) as in lintels upto 1.50 metre clear span,cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form works complete all as specified. 8 3.5 Cubic metre
9 9 Plain cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) as in surface channel and drain including all necessary form work, complete all as specified and directed. 9 1.5 Cum
10 10 Broken stone hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engr-in-Charge 10 4 Cubic metre
11 11 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in mass concrete, filling & sub base to floors, complete all as specified and as directed by Engr-in-Charge 140 Square metre
12 12 75mm PVC multi floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4). complete all as specified and as directed.(ISI Mark) 12 5 Each
13 13 Rolled mild steel in roof trusses (framed) , trussed , purlins,crane gantries , rails and fastening and heavy bracket framing ( beam, tee, angle, channel or flat section) including distance pieces conforming to Fe 410-W, Gde E-250 Quality 'A', complete all as specified and as directed.\nNote: All steel structures (truss and other member) shall be as per Drg No CE/TD/911/88 Sheet 1/20 t0 20/20. 13 3750 Kilogram
14 14 Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut diameter of neck 12mm not exceeding 20mm and lrngth of bolt exceeding 30cm long, complete all as specified and directed. 14 110 Kilogram
15 15 Gusset/Base Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment) with riveted bolted or wlded, complete all as specified and as directed by Engr-in-Charge. 15 350 Kilogram
16 16 Preparation of steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide/ zink chrome primer complete all as specified. 16 130 Square metre
17 17 Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and directed \n 17 210 Square metre
18 18 Pre-painted coloured plain steel profiled Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and directed. 18 10 Square metre
19 19 False ceiling with fibre cement designer tile ivory/white painted (high pressure steam cured) of 4 mm thickness (as per IS:14862) of size 595 x 595 mm and any one of the design (occeanic, lake & hill,cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gms, both side inclusive) consisting of main 'T' runner with suitably spaced joints to get required length, and 15x32 mm made of 0.30 mm sheet, and cross'T' at 600mm c/c to form a grid including, required cutting/making, opening for services like diffusers,grills,light fittings, fixures,smoke detectors etc. Main 'T' runners to be suspended from ceiling using Gl soffit cleats fixed to existing rafter, purlin, etc with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15 mm of all T- sections shall be centra black pre- painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, and refixed all existing electric wiring and fixture all complete at all heights as per direction of Engineer-in -Charge. 19 140 Square metre
20 20 Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge. 36 Cubic metre
21 21 RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beam; plinth beams; bases of columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engr-in-Charge. 21 20 Cubic metre
22 22 RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and as directed by Engr-in-Charge. 22 8 Cubic metre
23 23 RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed by Engr-in-Charge. 23 5 Cubic metre
24 24 Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to obtain rough finished flat surfaces of concrete complete all as specified and as directed. 24 100 Square Metre
25 25 Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions etc, square, ractangular or polygonal, to obtain rough finished flat surface of concrete complete all as specified and as directed. 25 85 Square Metre
26 26 Use and waste of form work to sides and sofits of floor or roof beams, beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc to obtain rough finished flat surface of concrete complete all as specified and as directed by Engr-in-Charge. 26 55 Square Metre
27 27 TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge. 27 2550 Kilogram
28 28 TMT mild steel bars, 6 to 8mm dia, as in stirrups, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge. 28 1470 Kilogram
29 29 Non skid, coloured ceramic jointfree/rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match,over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge. 29 13.5 Square metre
30 30 Glazed coloured ceramic jointfree/rectified tiles of size (600x300mmx8-10mm) thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match, over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3 finished rough for receiving tiles, complete all as specified and as directed by Engr-in-Charge. 30 60 Square metre
31 31 Black granite(of any type) stone slab 15-16 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with rounding to edges of stone slabs one edg complete Including 10mm thick backing coat CM 1:4 complete all as specified and as directed by Engr-in-Charge. 3.15 Square metre
32 32 10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge. 32 180 Square metre
33 33 Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge. 33 100 Square metre
34 34 Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified. 34 40 Square metre
35 35 Vitreous china wash down water closet,(pedestal pattern) casecade, Ivory colour, complete including soft close seat cover, twin flush fittings connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, complete all as specified and as directed by Engr-in-Charge. 35 4 Each
36 36 10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed by Engr-in-Charge. 36 4 Each
37 37 Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed by Engr-in-Charge 4 Each
38 38 PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified. 38 13 Each
39 39 Health faucet with 8mm dia 1m long flexible tube and wall hook with all accessories complete all as specified and as directed by Engr-in-Charge. 39 4 Each
40 40 Water jet to EWC's with flexible pipe, chromium plated, suitable for 15 mm bore and making connections, complete all as specified and as directed by Engr-in-Charge. 40 4 Each
41 41 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engr-in- Charge. 14 Running metre
42 42 110 mm bore PVC SWR bends any radius with acess door and fixed solvent etc complete all specified and as Directed (ISI Marked) 42 6 Each
43 43 75 mm bore PVC SWR bends any radius with acess door and fixed with solvent etc complete all specified and as Directed (ISI Marked) 43 6 Each
44 44 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors/fixed to walls, complete all as specified and as directed by Engr-in- Charge. 10 Running metre
45 45 75mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors/fixed to walls, complete all as specified and as directed by Engr-in- Charge. 10 Running metre
46 46 Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 2000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), complete all as specified and as directed by Engr-in-Charge. 2 Each
47 47 15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified. 20 Running metre
48 48 20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified. 50 Running metre
49 49 25mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified. 70 Running metre
50 50 Bib taps, fancy type, long body, cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, complete all as specified and as directed by Engr-in-Charge. 5 Each
51 51 Brass Chromium plated over head shower rose of dia 125mm with swivel joint fixed to pipe or union of 15mm bore, complete all as specified and as directed by Engr-in-Charge. 2 Each
52 52 Angular stop cock/Angle cock with wall flange, fancy type, brass, chromium plated, screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, complete all as specified and as directed by Engr-in-Charge. 52 16 Each
53 53 Brass chromium plated wall mounted mixture unit, fancy type, 3 in 1 system with provision for both hand shower and overhead shower complete with 1 mm long bend pipe connecting legs and wall flange for bore of pipe 15 mm, ,complete all as specified and as directed by Engr-in-Charge. 53 2 Each
54 54 600 mm x 450 mm bevelled edge mirror of thickness 5/5.5mm of slected quality glass, mounted on 6 mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete, all as specified and as directed by Engr-in-Charge. 4 Each
55 55 Solid PVC door frame of size 50mm x 47mm made out of 5mm wall nut colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings complete all as specified. 55 18 Running metre
56 56 Factory Made Solid PVC Moulded Door Shutterof wall nut colour, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet onback face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed. 56 5 Square meter
57 57 150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark) 57 4 Each
58 58 150 mm aluminium bow handles, cast type anodised complete all as specified and directed. (ISI Mark) 58 8 Each
59 59 Stainless steel, 100mm butt hinges ,heavy weight ,cold rolled mild steel ,all as complete all as specified and directed. 59 16 Each
60 60 250 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete, all as specified. (ISI Mark) 60 4 Each
61 61 Oval under counter wash basin, white flat back size 560 x 470mm including waste coupling CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron suitable size embedded in PCC block with PCC 1:2:4 type B-1 and HDPE pipe bend 32mm dia & CP getting with holes, complete all as specified and as directed by Engr-in-Charge. 61 4 Each
62 62 Brass chromium plated centre hole basin mixer 15 mm bore for mixing hot & cold water screw down for iron pipe, complete all as specified. 62 4 Each
63 63 Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors , windows , ventilators and partitions (fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required conforming to IS:733 and IS:1285 , fixing with dash fasteners of required dia and size , including necessary filling up the gaps at junctions , i.e. at top , bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth , rust free , straight , mitred and jointed mechanically wherever required including cleat angle , Aluminium snap beading for glazing paneling , C.P. brass / stainless steel screws, all complete as per architectural drawings complete all as specified and as directed. 63 1050 Kilogram
64 64 5mm Sheet glass, ordinary quality and glazing with rubber neoprene packing for aluminium doors/windows in square/rectangular exc 0.5 sq. m in each pane, including at top , bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth , rust free , straight , mitred and jointed mechanically wherever required including cleat angle , Aluminium snap beading for glazing paneling , C.P. brass / stainless steel screws, all complete as per architectural drawings complete all as specified and as directed. 64 70 Square metre
65 65 S&F aluminium composite panel (ACP) of 4mm thick sheet coated mirror glossy finish/ Natural wood finish of approved colour, pattern & design & as required shape like rectangular, trapezoidal or tapered curved shape ( colour, shade, texture as per sample kept in GE office) with aluminium beading and EPDM rubber complete all as specified and as directed. 65 80 Square metre
66 66 S&F stainless steel 'S' shape handles 300mm long fancy type fixed with screws to doors shutters complete all as specified and directed. (ISI Mark) 10 Each
67 67 Brass body mortice lock, four levers vertical type size 100mm or above with three keys complete all as specified and as directed by Engr-in-Charge. 10 Each
68 68 S&F Sliding roller for Sliding door (04 Nos Wheels in each roller) fixed to aluminium door with screws in position, complete all as specified. 68 12 Each Pair
69 69 Powder coated aluminium Deco grill DG 202 pattrn with apperture of size 60x45mm securing with suitable aluminium channel to frame complete all as specified as directed by Engr-In-Charge. 10 Square metre
70 70 Stainless steel mosquito proof wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium flat/channel and screws complete, all as specified and directed by Engr in Charge. 6 Square meter
71 71 Vitrified tiles (double charged) of 10mm thick any colour (area of each tile exceeding 0.42 sqm but not exceeding 0.64 sqm) as in floors jointed in cement slurry and pointed in white or coloured cement to match the existing surfaces over and including 10 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge. 71 135 Square meter
72 72 5mm thick Insulated PVC Wall Lining honeycombed consisting of PVC Insulated Panels with approved colour and design printed PVC sheet used colour PVC sheet duly fitted into the wall including PVC sheet in strips feathered at the edges including removing and refixing electric switch boards & plates and covered with PVC stripes or beading after fixing wall panelling as per specifications Complete all as specified . 80 Square metre
73 73 S&F in reapirs 22 mm dia MS powder coated antique type curtain rods with bracket fixed to wall with suitable screws and onion type end brackets all as per approved design/colour/pattern fixed as directed in Engr-in-Charge. 35 Running metre
74 74 15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge.\nNote : Water proofing compund to be measured and paid for separately as supply only. 195 Square metre
75 75 Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of primer, complete all as specified and as directed by Engr-in-Charge. 75 155 Square metre
76 76 Reinforced concrete pipes 150mm bore ,class NP2,laid and jointed complete with coller all as specified and as directed. 76 60 Running metre
77 77 Plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes all as specified. 77 45 Running metre
78 78 Precast Reinforced cement concrete 1:2:4 (Nominal mix) type B-1, using 20mm graded crushed stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves, fins and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar 1:4 complete all as specified. 0.25 Cubic Metre
79 79 TMT mild steel bars, 6-8 mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed by Engr-in-Charge. 75 Kilogram
80 80 M&L Aadvanced septic tank 5000 liter per day suitable to retain micro organism  long enough to digest the organic waste by 70% of BOD reduction from final outlet including inlet and outlet pipes of 100mm dia and 50mm dia vent pipe, internal piping, manhole cover, Excavation, RFR, Removing excavated soil and 100mm thick PCC Bed Type D-2, 1:4:8 (40mm graded aggregate) all including etc complete all as specified. \nMake - Sintex code No PWTS - AM - 500-01 or equivalent apporved. 80 1 Each
81 81 RCC M-25 (design mix), using 20 mm graded crushed stone aggregate. as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge. 81 1 Cubic metre
82 82 Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed. 82 5 Square metre
83 83 100 mm thick, Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in floor finishes even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge. 83 40 Square metre
84 84 Point wiring for light/ fan point with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light /fan/ bell controlled by one switch with modular metal flush box suitable for module concealed on walls,cover plate with frame for mounting of switches, socket outlet, regulator etc suitable for modular type , fixed with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge. 88 Per Point
85 85 Description all as per item No 84 above but for bell/buzzer. 1 Per point
86 86 Description all as per item No 84 above but one 5 pin 10 Amp socket outlet on the same board with other switch. 8 Per Point
87 87 Description all as per item No 84 above but one 3/5 pin 10 Amp socket outlet on independent board . 15 Per Point
88 88 Description all asper item No 84 above but one 3/5 pin 20 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 4 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 4 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge. 23 Per Point
89 89 Modular switch 1 way 10A, 1 module, complete all as specified and as directed by Engr-in-Charge. 111 Each
90 90 Socket 10A - 2/3 pin combined, 2 module, modular type complete all as specified and as directed by Engr-in-Charge. 23 Each
91 91 Modular switch 1 way 20A, 1 module, complete all as specified and as directed by Engr-in-Charge. 91 23 Each
92 92 Modular socket, 20Amps, 2/3 pin combined 2 module, complete all as specified and as directed by Engr-in-Charge. 92 23 Each
93 93 Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge. 93 27 Each
94 94 Bell (ding dong type), AC electronic type, 230 volts, single pole , complete all as specified and as directed by Engr-in-Charge. 94 1 Each
95 95 Modular type bell push 10 Amps 230 volts,1 module, complete all as specified and as directed by Engr-in-Charge. 1 Each
96 96 Modular type stepped type fan regulator 120W, 230V 50 C/S, Deluxe 2 Modular electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge. 96 9 Each
97 97 Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - \n(a) Housing of Light fitting : Aluminium Extruded\n(b) Operating Voltage : Between 150 V- 270V\n(c) Operating Temperature : -10 to +45 Degree Centigrade\n(d) Lumen efficacy : Not less than 110 lm/W\n(e) System Lumens : Not less than 2000 lm\n(f) Colour Temperature : Not less than 5700K\n(g) Surge Voltage Protection : Up to 2KV\n(h) Ingress protection : IP 20\n(j) Total Harmonic Distortion (THD) : Not less than 20%\n(k) Power factor : Not less than : 0.90\n(l) Line protection : Under/Over voltage Protection \n(m) Input Frequancy : 50 Hz 14 Each
98 98 Decorative ultra slim linear surface mounted LED lighting fixture (2 feet length), 10 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - \n(a) Housing of Light fitting : Aluminium Extruded\n(b) Operating Voltage : Between 150 V- 270V\n(c) Operating Temperature : -10 to +45 Degree Centigrade\n(d) Lumen efficacy : Not less than 100 lm/W\n(e) System Lumens : Not less than 1000 lm\n(f) Colour Temperature : Not less than 5700K\n(g) Surge Voltage Protection : Up to 2KV\n(h) Ingress protection : IP 20\n(j) Total Harmonic Distortion (THD) : Not less than 20%\n(k) Power factor : Not less than : 0.9\n(l) Line protection : Under/Over voltage Protection \n(m) Input Frequancy : 50 Hz 98 4 Each
99 99 Environmental friendly, new generation,aesthetically designed, ultra modern, glare-free symmetric light distribution SURFACE mounting luminaire with high efficiency long life LED integral module as light source, 42 Watt 2'x2' LED flat Panel luminire with SELV Output electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing including making good disturbed surface all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - \n(a) Housing of Light fitting : CRCA powder coated\n(b) Diffuser : High transmittance polystyrene opal diffuser\n(c) Operating Voltage : 150 V- 270V\n(d) Operating Temperature : -10 to +45 Degree Centigrade\n(e) Lumen efficacy : Not less than 100 lm/W\n(f) System Lumens : Not less than 3600 lm\n(g) Colour Temperature : Not less than 5700K\n(h) Surge Voltage Protection : Up to 2KV\n(j) Ingress protection : IP 20\n(k) Total Harmonic Distortion (THD) : Not less than 20%\n(l) Power factor : Not less than : 0.9\n(m) Line protection : Under/Over voltage Protection \n(n) Input Frequancy : 50 Hz\n(o) Dimension of fitting : (600 x600 x 50)mm\n 20 Each
100 100 Environmental friendly, energy saving, surface mounted, decorative LED 10 Watt Bulk head luminire, with integral electronic LED driver with APFC and lower THD, Output complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following :-\n(a) Housing of Light fitting : Die Cast Aluminium\n(b) Diffuser : Polycarbonate UV protected diffuser\n(c) Operating Voltage : Between 140 V- 270V\n(d) Operating Temperature : -10 to +45 Degree Centigrade\n(e) Lumen efficacy : Not less than 100 lm/W\n(f) System Lumens : Not less than 900 lm\n(g) Colour Temperature : Not less than 5700K\n(h) Surge Voltage Protection : Up to 4kV\n(j) Ingress protection : IP 65\n(k) Total Harmonic Distortion (THD) : Not less than 20%\n(l) Power factor : Not less than : 0.9\n(m) Line protection : Under/Over voltage Protection \n(n) Input Frequancy : 50 Hz\n 100 4 Each
101 101 Supply & hanging ceiling fan AC single phase 230/240 volts of size 1200 mm sweep , having service value > 4.0 including making connection with and including suitable flexible copper wire, complete all as specified and as directed by Engineer-in-Charge.\n\n\n 9 Each
102 102 Supply & fixing exhaust fan AC single phase 230/240 V of size 300mm sweep, speed 1400 RPM power input 50-55 W, Heavy duty with louver having aliminium / sheet metal flap with thickness not less than 1.00 mm and mounting assembly including fixing exhaust fan with grouting of nut & bolts , complete all as specified and as directed by Engr-in-Charge.\n\n 4 Each
103 103 Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked (concealed) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6 sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified and directed by Engr-in-Charge.\n Note:- 2 runs of 6 Sqmm (2x6 sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit. 103 95 Running metre
104 104 Sheet metal enclosure VTPN 4 way 415 volt 250 Amp rated bus bar double door type , mechanical impact strength IK-09 with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB , IP - 54 protection grade fixed flush to wall complete including cable connections should be provide with necessary reducer lugs complete all as specified and as directed by Engr-in-Charge. 104 1 Each
105 105 MCCB 4 pole, 415 volts 160 Amps with breaking capacity 25 KA with thermal adjustble, complete all as specified and as directed by Engr-in-Charge. 1 Each
106 106 Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-54, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications , complete all as specified and as directed. 2 Each
107 107 MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. 2 Each
108 108 MCB SP, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. 108 20 Each
109 109 MCB SP, 40 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. 6 Each
110 110 Sheet metal enclosure single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge. 110 6 Each
111 111 Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :-\n(a) Excavation and earth work for drilling hole for electrode in any type of soil. \n(b) PCC pit in cement concrete 1:2:4 type B-1. \n(c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.\n(d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. \n 111 2 Each Job
112 112 Srl item No 111 Contd …\n(e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. \n(f) Requisite quantity of common salt and charcoal.\n(g) Testing of earthing.\nNote : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
113 113 XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 50 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge. 113 85 Running metre
114 114 Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. \nNOTE Only punned thickness shall be measured for payment purpose. 5 Cubic Metre
115 115 Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge. 480 Each
116 116 GI tubing light grade 50mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge. 116 20 Running metre
117 117 Geyser 25 Ltrs capacity verticle type BEE 5 star rating suitable to operate in Single phase AC supply, 230 volts 50 Hz including suitable size heavy duty PVC connection hot & cold and grouting fashner with suitable size on the wall as per site requirment all as specified and directed by EIC. 2 Each
118 118 M&L for PVC hot and cold pipe with check nuts and washer 300 mm long complete all as specified and as directed by Engr-in-Charge. 118 4 Each