Military Engineer Services-MES has published Repair/Maintenance Of Summer Appliences Geyser , Water Coolers , Refrigerators And Allied Connected Works At Lekhapani Military Station Under Ge Lekhapani Repair/Maint Of Summer Appliences Geyser , Water Coolers , Refrigerators And Allied Connecte. Submission Date for this Tender is 26-06-2021. Water Cooler Tenders in GE LEKHAPANI Assam. Bidders can get complete Tender details and download the document.




Tender Notice

28028864
Corrigendum : Repair/Maintenance Of Summer Appliences Geyser , Water Coolers , Refrigerators And Allied Connected Works At Lekhapani Military Station Under Ge Lekhapani Repair/Maint Of Summer Appliences Geyser , Water Coolers , Refrigerators And Allied Connecte
National Competitive Bid
Indian
Assam
GE LEKHAPANI
26-06-2021

Tender Details

Repair / Maintenance Of Summer Appliences Geyser , Water Coolers , Refrigerators And Allied Connected Works At Lekhapani Military Station Under Ge Lekhapani Repair / Maint Of Summer Appliences Geyser , Water Coolers , Refrigerators And Allied Connected Works At Lekhapani Military Station Under Ge Lekhapani

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Jun-2021 AMENDMENT8608 BOQ 19-06-2021
2 19-Jun-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 9000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : Repair/ maintenance of summer appliances Geyser,Water cooler,Refrigerator & allied connected works at Lekhapani Mil Stn.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down unserviceable window /Spit type AC of Capacity 1.5/2/ TR capacity from existing location and transportation to work shop for repair and return after necessory servicing, repair and refixing in its original position including necessory connection complite all as directed. Note:- (a)Necessory a if required for replacement will be measured and paied in respective items. 12 Each Job
2 2 Disconnecting the electric connection,Overhauling/Servicing to the window type/Split type air conditioners including wiring kit and painting(two coats of synthetic enamel paint of interior and external portion of any Make/Capacity by dismantling all removable components and cleaning the same by compressed air water etc and refixing including replacement of defective parts, including gas charging(if required) and replacement pins nuts,bolts & washers etc complete all as directed. \nNote: (a)All facility ACs for repair will be attended at site only. (b)Necessory spare/gas if required for replacement will be measured and paied in respective items. 8 Each
3 3 Supply & Fixing sealed compressor for 1.5 ton capacity as taken out vide srl item No 1 above all as directed.Make kirloskar /Tecumsheh/Voltas 6 Each
4 4 All as item no-3 above but sealed compressor for 2 TR Capacity as Taken out vide srl item No 1 above all as directed Make : Kirloskar/Tecumsheh. 1 Each
5 5 All as item no-3 above but relay for window type AC/Spit AC of Capacity 1.5 TR type 1622 ( Make Renetor/Shriram). 2 Each
6 6 All as item no-3 above but thermostat for window type AC /spit type AC Capacity 1.5/2 TR ( Make Renetor Danfos/Indfoss). 3 Each
7 7 All as item no-3 above but of fan blade for window type AC Capacity 1.5 TR 3 Each
8 8 All as item no-3 above but for Blower motor suitable for window type AC /spit type AC Capacity 1.5/2 TR ( Make Renetor/ Danfos/Indfoss). 5 Each
9 9 All as item no-3 above but for window type AC front panel grill as per existing Capacity 1.5 TR. 2 Each
10 10 supply and fixing Time delay switch suitable for Maximum 3 minutes delay time relay unit with high/lowcut with timer 25 Amps suitable for 1.5/2 ton AC ( Makw VENUS/EICHER. 3 Each
11 11 S& F for replacement to unserviceable capacitor 36+6mfd with new suitable for rotary type compressor of window /split type AC complete all as specified and as directed by Engineer-in-Charge. 4 EACH
12 12 S& F for replacement to unserviceable capacitor 45+10mfd with new suitable for rotary type compressor of window /split type AC complete all as specified and as directed by Engineer-in-Charge Make : UNIVERSAL/SARADA 4 EACH
13 13 Supply and Fix Running and starting capacitor required at site to be fitted in split / window Acs removed from site. 3 Each
14 14 S & F Over load protector relay 1 Each
15 15 Supply and charging of refrigerant Gas R-22 15 KG
16 16 Supply and charging of refrigerant Gas R-134a. 12 KG
17 17 supply and fix air filter for window Acs/Split Acs 2 Each
18 18 Supply and fixing automatic sensor card suitable for 1.5ton split air conditioner.Make;- LG/Samsong/Voltas 2 Each
19 19 Supply and fixing automatic sensor card suitable for 2 ton split air conditioner.Make;- LG/Samsong/Voltas 1 Each
20 20 Supply and fixing remotcontrol suitable for 1.5/2 Ton air conditioner.Make:- LG/Samsung/Voltas. 2 Each
21 21 Dismantling to Blower fan motor from window/split type AC and rewinding to same with super enameled copper wire of appropriate gauge including insulation, varnishing &replacement of worn out bearing, bush, capacitor etc complete all as specified and as directedby Engineer-in-charge. 3 EACH
22 22 S& F for new copper pipe of dia 5/8 inch insulated by Nytril foam for suction line including brazing and making as leak proof and testing as in repair complete all as specified and as directed by Engineer-in-Charge. 18 RM
23 23 S& F for new copper pipe of dia 1/4 inch insulated by Nytril foam for discharge line including brazing and making as leak proof and testing as in repair complete all as specified and as directed by Engineer-in-Charge.. 15 RM
24 24 Disconnecting carefully all outgoing connections of outdoor/indoor unit of split type AC 1.5/2.0 ton and to be shifted on roof of the same building at height not more than 4.0m all as directed. 3 Each Job
25 25 supply and fixing PVC insulated Industrial Flexible sheathed multistandred cable 3 core 10 sq mm copper conductor 1100 Volts grade ( Make:KEI Richa/Payal/Plaza) 20 RM
26 26 supply and fixing PVC insulated Industrial Flexible sheathed multistandred cable 3 core 6 sq mm copper conductor 1100 Volts grade ( Make:KEI Richa/Payal/Plaza) 20 RM
27 27 S & F Clamp for outdoor unit of split type AC including nut bolt etc 3 Each
28 28 S & F 3-1/2 inch black Foam rubber pipe insulation suitable for split AC Copper pipe isulation 50 RM
29 29 Disconnecting the water and Electric connection from water cooler of any capacity and transportation to worksop for repair / serviceing of the same and refixing in its original position /reconnection all as diercted. Note: (a)All facility water cooler for repair will be attended at site only. (b)Necessory spare/gas if required for replacement will be measured and paied in respective items. 10 Each Job
30 30 Supply & Fixing the sealed compressor unit suitable for 40 ltrs/hr capacity for water cooler all as specified and directed. Make:- /Kirloskar/TECUMSEH/GODREJ.) 3 Each
31 31 All as per item No 33 above but for 80 ltrs/hrs capacity water coolers.Make:- /Kirloskar/TECUMSEH/GODREJ.) 3 Each
32 32 All as per item No 33 above but for 120 ltrs/hrs capacity water coolers.Make:- /Kirloskar/TECUMSEH/GODREJ.) 2 Each
33 33 All as per item No 33 above but for 150 ltrs /hrs capacity water coolers.Make:-/Kirloskar/TECUMSEH/GODREJ.) 1 Each
34 34 All as per item No 33 above but Strating of capacity 80/100 MFD . Make Universal. /Usha /Aristo. 5 Each
35 35 All as per item No 26 above but Capacitor of capacity 40/60MFD . Make Universal /Usha /Aristo. 5 Each
36 36 All as per item No 33 above but Running Capacitor of capacity 34/36 MFD .Make:-Universal/Usha/Aristo. 6 Each
37 37 All as per item No 33 above but Capacitor of capacity 4 MFD. Make : Unuivsrsal /Usha /Aristo. 6 Each
38 38 All as per item No 33 above but Capacitor of capacity 8 MFD Make:-Universal/ Usha/Arosto/Havells. 6 Each
39 39 All as per item No 33 above but relay for water cooler of capacity 40/80/120/150 ltr/hrs type 412 .Make Renetor/Shriram/Dun Foss. 8 Each
40 40 All as per item No 33 above but Thermostat for water cooler capacity 40/80/120/150 ltr/hrs. Make :- Renetor/shriram/Godraj/Danfoss. 4 Each
41 41 All as per item No 33 above but Blower motor suitable capacity for water cooler 40/80/150 ltr. Make :-.Annapurna/Godraj/Danfoss. 4 Each
42 42 All as per item No 33 above but Blower Fan . Make :-. Renetor/shriram/Godrej/Danfoss. 2 Each
43 43 M&L for Re-winding of fan motor with appropriate gauge of super enameled copper conductor to match with the existing design including replacement of ball bearing, bush, capacitor, rubber base including overhauling, testing and re-fixing complete all as directed 3 Each Job
44 44 Supply and fixing for bib tap Cast copper alloy 15 mm Push type chromium plated. 8 Each
45 45 S/F PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15 mm dia GI Pipe. 10 Each
46 46 S/F PVC Float valve with epoxy coated aluminium arm , with PVC polythene ball suitable for water coolers. 10 Each
47 47 S/F PVC polythene ball suiatble to fix to 15mm PVC float valve. 12 Each
48 48 S/F PVC drain out pipe 25 mm dia bore as per existing by providing necessary GI Clamps nuts bolts etc. 10 RM
49 49 M/L for replacement of base plate of water cooler of any cacapcity, made out of 2 mm ehick MS sheet and painting with two coats of enamel paint over one coatt of re oxide. 1 Each Job
50 50 S/F for Water cooler door lock CP as per existing with duplicate key. 4 Each
51 51 S/F door rubber inner liner (magnetic) suitable for water cooler capacity 40 ltrs. 2 Each
52 52 S/F door rubber inner ( Magnetic suitable for water cooler Capacity 80ltrs. 2 Each
53 53 S/F door rubber inner liner ( magnetic) suitable for watercooler Capacity 150 ltrs. 1 Each
54 54 Disconnecting unserviceable Refrigerator of any capacity fron existing location and transporting to workshop for repair and reinstallation in original position(Necessory replacement of spare parts will be measured and paid separately in respactive items.). 10 Each Job
55 55 Supply and fixing of sealed compressor for repair of 165/175 ltrs capacity Referigerator as takenout from above all as specified and directed.Make shriam/Kirloskar). 4 Each
56 56 All as per item No 58 above but for sealed compressor refrigerator of capacity 286/300 ltrs.Make shriam/Kirloskar. 3 Each
57 57 All as per item No 58 above but for Thermostat for refrigerator Capacity 165/175 Ltrs . Make:- Renetor/Shriram/Godraj/Danfoss 2 Each
58 58 All as per item No 58 above but for Thermostat for refrigerator Capacity286/ 300 Ltrs ( Make Renetor/Shriram/Godraj/Danfoss 8 Each
59 59 All as per item No 58 above but for chiller tray for refrigerator for 286/ 300 ltrs Capacity. 3 Each
60 60 All as per item No 58 above but for PVC Ice tray for refrigerators. 10 Each
61 61 All as per item No 58 above but for Vegitable tray for refrigerators 165/175 ltr Capacity). 3 Each
62 62 All as per item No 58 above but for vegitable tray for refrigerators 286/300litre capacity. 3 Each
63 63 All as per item No 58 above but for door hinges suitable for referigerator 165/175/286/300 litre Capacity. 2 Each
64 64 All as per item No 58 above but for Refrigerator freezer unit evaporator door only capacity 286/300 litrs 1 Each
65 65 All as per item No 58 above but for refrigerator freezer unit evaporator door only cpacity 165/175 ltrs with spring. 1 Each
66 66 All as per item No 58 above but for copper capillary tube assembly for 286/300 litr Capacity refrigerator 2 Each Set
67 67 All as per item No 58 above but for Cooling coil tube assembly ,aluminum for 286/300 litre capacity refrigerator. 2 Each Set
68 68 All as per item No 58 above but for Cooling coil tube assembly ,aluminum for 165/175 litre capacity refrigerator. 3 Each Set
69 69 All as per item No 58 above but for PVC refrigerator stand suitable for165/ 286/310 litre refrigerator ( Make:- KELVINATOR/ GODREJ/LG. 4 Each
70 70 All as per item No 58 above but for Timer assembly suitable for 165/175 ltrrefrigerator (Make:- INDFOSS /Renetrol). 6 Each
71 71 All as per item No 58 above but for Timer assembly suitable for286/300 litre refrigerator ( Make:- INDFOSS/Renetrol). 6 Each
72 72 Supply and fixing door rubber inner liner suitable for refrigerator capacity 165 ltrs 3 Each
73 73 Supply and fixing door rubber inner liner suitable for refrigerator Capacity 286/300 ltrs 3 Each
74 74 Supply install, test and commission hermetically sealed reconditioning compressor suitable for 330/320 ltr capacity Deepfreezer of different makes including vacuum sing, initial charging of oil and refrigerant gas of required quantities to ensure efficient functioning and proper cooling & testing complete all as directed. (Note : Refrigerant and comp oil for charging to be supplied by the contractor. The Factory Re-conditioned Compressor shall be accompanied by certificate from the manufacturer to the effect that the compressor has been repaired at their Auth, Service center, further, a warranty of not less than 12 months shall be provided on the compressor). 1 EACH
75 75 All as per item No. 77 here-in-before but for Deepfreezer of capacity 500 Ltrs. 1 EACH
76 76 Supply and fixing of new overload protector suitable for 300/500 ltrs capacity Deepfreezer to match with the existing design. 2 EACH
77 77 S& F for replacement of unserviceable thermostate with new suitable for 310/300/286/185/165 litre capacity Deepfreezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge. 1 EACH
78 78 S& F for replacement of unserviceable open type relay with new suitable for 320/500 litre capacity Deepfreezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge. 1 EACH
79 79 S& F for replacement of unserviceable pigmy lamp with new suitable for any capacity Deepfreezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge.Make :Plhilips/Omex. 1 EACH
80 80 S& F for replacement of unserviceable relay with new suitable for any capacity Deepfreezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge. Make : Sriram /Godrej 2 EACH
81 81 S& F for replacement of unserviceable strainer with new suitable for any capacity Deepfreezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge. 1 EACH
82 82 S& F for replacement of unserviceable capillary copper tube with new suitable for any capacity Deepfreezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge. 8 RM
83 83 M&L for rubber door gasket suitable for Deepfreezer of any capacity/make and provision for making air tight of the system complete all as specified and as directed by Engineer-in-Charge. 3 RM
84 84 M &L for Refrigerant charging of 320/500 ltr capacityDeepfreezer with required quantity refrigerant gas after vaccuumising the system thoroughly, sealing and leak testing complete all as specified and as directed by Engineer-in-Charge. 2 EACH
85 85 Checking, Diagnosing and Rectifying Minor faults in Deep Freezers of any capacities at installed locations as per site requirements complete all as specified and as directed by Engineer-in-Charge. 2 Each Job
86 86 Taking down, opening and dismantling storage type water heaters (geysers) of capacity 25/50 ltrs vertical/horizontal type cleaning, descaling, re-assembling and re-installation in the existing place and container by hand operated hydraulic pump complete after necessary repair/replacement of unserviceable items all as directed . (Note : Spare as required shall be measured and paid under relevant items) 38 Each Job
87 87 S & F heating element of rating 2000 W circular/triangular shape push/thread type with rubber washers of make Bajaj/Theeta/Johnson/Racold 35 Each
88 88 S & F thermostat for geyser of capacities 25/50 Ltrs of make Bajaj/Elcon/Johnson/Racold 30 Each
89 89 Supply and fix safety valve/high pressure air release valve ISI marked. 16 Each
90 90 Supply and fix hot/cold water PVC armoured heavy duty connection pipe suitable for hot water of size 15 mm dia with PTMT nuts of length 450 mm including taking down old/damage PVC connection pipe all as directed 30 Each
91 91 Supply and fix angular stop cock fancy type chromium plated of size 15 mm dia 5 Each
92 92 Repair of Voltage stablizer for autumatic operation, single phase naturally air cooled indoor type and designed for input variation between 150 V to 280 V with output voltage stablized at 230 V with accuracy of ± 2.5 % and of capacity upto 2.0 KVA all as specied and as directed. 4 Each Job
93 93 Repair of Voltage stablizer for autumatic operation, single phase naturally air cooled indoor type and designed for input variation between 150 V to 280 V with output voltage stablized at 230 V with accuracy of ± 2.5 % and of capacity upto 4.0 KVA all as specied and as directed. 5 Each Job