Military Engineer Services-MES has published Repair And Maintenance Of Cooling Appliances , Split Type Ac , Window Ac , Water Cooler , Refrigerator , Deepfreezer , Desert Cooler , Voltage Stabilizers , Central Ac Plants , Package Type Ac Plants , Electrical Panel And Misc Items At 9 Brd Af. Submission Date for this Tender is 23-06-2021. Voltage Stabiliser Tenders in GE (AF) LOHEGAON, PUNE Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 16-Jun-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-06-2021 |
Name of Work: REPAIR AND MAINTENANCE OF COOLING APPLIANCES, SPLIT TYPE AC, WINDOW AC, WATER COOLER, REFRIGERATOR, DEEPFREEZER, DESERT COOLER, VOLTAGE STABILIZERS, CENTRAL AC PLANTS, PACKAGE TYPE AC PLANTS, ELECTRICAL PANEL AND MISC ITEMS AT 9 BRD AF STATION PUNE. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | REPAIR AND MAINTENANCE OF CENTRAL AC PLANTS, PACKAGE TYPE AC PLANTS, ELECTRICAL PANEL AND MISC ITEMS AT 9 BRD AF STATION PUNE.\nM&L for servicing, cleaning & greasing of AHU with complete accessories such as cooling coil, air filters, greasing of blower motor, blower/drum, blower shaft, checking of electric control cable connections & cleaning of Pot Strainer/Y strainer of chillier/condenser line including replacement of strainer jail if required etc. up to satisfaction of Engr in Charge. | BI01010001010000000000000515BI0100001114 | 5 | Each Job |
2 | 2 | M&L for descaling of condenser (up to 18 TR) with dilute sulphuric acid solution (as per OEM manufacturers specification) by using decaling pump for circulation of solution and brushing with nylon brush by opening both side covers and cleaning/flushing out the dirt, sludge with water up to satisfaction of Engr in charge and re-fixing the side cover with new gasket, replacement of worn out nut, bolts & washers and leak detection complete all as specified and directed. | BI01010001010000000000000515BI0100001115 | 6 | Each |
3 | 3 | M&L for descaling of condenser (24 to 100 TR) with dilute sulphuric acid solution (as per OEM manufacturers specification) by using decaling pump for circulation of solution and brushing with nylon brush by opening both side covers and cleaning/flushing out the dirt, sludge with water up to satisfaction of Engr in charge and re-fixing the side cover with new gasket, replacement of worn out nut, bolts & washers and leak detection complete all as specified and directed. | BI01010001010000000000000515BI0100001116 | 7 | Each |
4 | 4 | Replacement of Unsv V belts with new V belts ISI marked of compressor & AHU as per existing size & type complete all as specified and directed. | BI01010001010000000000000515BI0100001117 | 20 | Each |
5 | 5 | M&L for servicing of compressor by disconnecting /detaching from motor after pump down the system and taking out the parts after strip opening of compressor (Make: ACCEL, 4x65L 18 TR ) Cleaning the parts of compressor & segregation of serviceable/unserviceable parts, keeping serviceable parts aside for reuse and replacing the worn out parts (taken as supply only), turning, lathe work on crank shaft if required, Reassembling the complete compressor parts, including checking leak test by using nitrogen pressure test at suitable pressure, vacuumed the compressor by using vacuum pump & filling oil and charging of gas R-22, testing and commissioning of complete system as per OEM specification complete all as specified and directed. \nNote: (i) Work shall be carried out through OEM Mechanics or Mechanic having 10 Years experience of repair of the compressor. \n(ii) Unserviceable nut, bolts, washers, springs etc. found unserviceable will be replaced and deemed to be included in the job work rate. \n(iii) Major spare parts, compressor oil and Frozen gas shall be measured and paid separately | BI01010001010000000000000515BI0100001118 | 4 | Job |
6 | 6 | Supply only of following spare parts of the compressor\n Make: ACCEL, 4x65L | BI01010001010000000000000515BI0100001119 | ||
7 | 6.01 | Cylinder liners with unloading ring with pin, washers, gasket | BI01010001010000000000000515BI0100001120 | 12 | Each |
8 | 6.02 | Piston set with piston rings and piston pin | BI01010001010000000000000515BI0100001121 | 12 | Each |
9 | 6.03 | Connecting rod with CR bush and bearing. | BI01010001010000000000000515BI0100001122 | 12 | Each |
10 | 6.04 | Suction/ Discharge valve assembly complete. | BI01010001010000000000000515BI0100001123 | 12 | Each |
11 | 6.05 | Shaft seal assly complete | BI01010001010000000000000515BI0100001124 | 6 | Each |
12 | 6.06 | O' ring set. | BI01010001010000000000000515BI0100001125 | 3 | Each |
13 | 6.07 | Gasket set. | BI01010001010000000000000515BI0100001126 | 3 | Each |
14 | 6.08 | Heater assembly | BI01010001010000000000000515BI0100001127 | 3 | Each |
15 | 6.09 | Heater | BI01010001010000000000000515BI0100001128 | 3 | Each |
16 | 6.1 | SV and DV reed set | BI01010001010000000000000515BI0100001129 | 12 | Each |
17 | 6.11 | Oil pressure regulating valve | BI01010001010000000000000515BI0100001130 | 2 | Each |
18 | 6.12 | Oil filter assembly | BI01010001010000000000000515BI0100001131 | 2 | Each |
19 | 6.13 | Filter Bag | BI01010001010000000000000515BI0100001132 | 2 | Each |
20 | 6.14 | Aluminum washer set | BI01010001010000000000000515BI0100001133 | 2 | Each |
21 | 6.15 | Coil for solenoid valve | BI01010001010000000000000515BI0100001134 | 4 | Each |
22 | 6.16 | solenoid valve | BI01010001010000000000000515BI0100001135 | 4 | Each |
23 | 6.17 | Cut Out LP HP | BI01010001010000000000000515BI0100001136 | 6 | Each |
24 | 6.18 | Loading unloading frame | BI01010001010000000000000515BI0100001137 | 8 | Each |
25 | 6.19 | Gear wheel & Neoprinence O ring of Oil pump | BI01010001010000000000000515BI0100001138 | 4 | Each |
26 | 6.2 | coupling for oil pump | BI01010001010000000000000515BI0100001139 | 2 | Each |
27 | 6.21 | crank shaft | BI01010001010000000000000515BI0100001140 | 1 | Each |
28 | 7 | M&L for replacement or top-up of u/s burnt compressor oil and charging with new lubricant oil for open type reciprocating compressor(4x65L Make- Accel) as per manufacturer's standard instruction\nMake - Servofriz-68 of Indian Oil Corpn. Ltd /Freezol- 68 of Bharat Petroleum | BI01010001010000000000000515BI0100001141 | 35 | Ltrs |
29 | 8 | M&L for charging of Refrigerant gas R-22 gas as per manufacturers instruction complete all as specified and directed. | BI01010001010000000000000515BI0100001142 | 100 | Kg |
30 | 9 | M&L for charging of Refrigerant gas R-134a gas as per manufacturers instruction complete all as specified and directed. | BI01010001010000000000000515BI0100001143 | 60 | Kg |
31 | 10 | M&L for servicing, cleaning of Cooling tower up to 100TR Cap, cleaning the storage tank, removal of all sludge , cleaning of strainer, servicing greasing of cooling tower motor, sprinkler hub assembly etc. complete up to satisfaction of Engr in charge. | BI01010001010000000000000515BI0100001144 | 5 | Each Job |
32 | 11 | M&L for servicing of Main Electric Panel board/Control panel board of Central/Package type AC Plant by cleaning the panel with blower, replacement of Unsv burnt wire, cables with existing size & length including proper numbering, replacement of u/s fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity, cleaning of contactors by contact cleaner etc. & find out defective parts and making the panel functional by replacing the Unsv item (taken as supply only) complete all as specified and directed. \nNote: (i) Unserviceable parts as MCB, MCCB, contactor, relay, MPD, etc. will be measure and paid separately.\n Minor parts like thimbles, tags, nut, bolts, washers, wire pieces etc. shall be deemed to be included in item rate. | BI01010001010000000000000515BI0100001145 | 2 | Each Job |
33 | 12 | Supply only of the following for above items (Make- Hager/C&S/L&T/Schneider/Siemens | BI01010001010000000000000515BI0100001146 | ||
34 | 12.01 | MCB 6-32 Amp SP C series | BI01010001010000000000000515BI0100001147 | 4 | Each |
35 | 12.02 | MCB TPN 40 to 63Amp C series | BI01010001010000000000000515BI0100001148 | 6 | Each |
36 | 12.03 | MCB TPN 10 to 32 Amp C series | BI01010001010000000000000515BI0100001149 | 5 | Each |
37 | 12.04 | Add on Auxiliary contact block (MNX A-2 /MNX A-1/TA1-DN22/LAN-11) | BI01010001010000000000000515BI0100001150 | 8 | Each |
38 | 12.05 | Voltage selector switch | BI01010001010000000000000515BI0100001151 | 4 | Each |
39 | 12.06 | HRC fuse link RH type having breaking capacity 80 kA ( 2-32 amps) | BI01010001010000000000000515BI0100001152 | 10 | Each |
40 | 12.07 | Fuse bases for HRC fuse up to 32 Amp | BI01010001010000000000000515BI0100001153 | 5 | Each |
41 | 12.08 | Contactor 3 phase having current rating 9 to 12 A | BI01010001010000000000000515BI0100001154 | 3 | Each |
42 | 12.09 | Contactor 3 phase having current rating 18 to 22 A | BI01010001010000000000000515BI0100001155 | 3 | Each |
43 | 12.1 | Contactor 3 phase having current rating 25 to 32A | BI01010001010000000000000515BI0100001156 | 3 | Each |
44 | 12.11 | Contactor 3 phase having current rating 40 A | BI01010001010000000000000515BI0100001157 | 3 | Each |
45 | 12.12 | Contactor 3 phase having current rating 70A | BI01010001010000000000000515BI0100001158 | 3 | Each |
46 | 12.13 | Thermal Over Load Relay (Auto/Manual reset) suitable for contractors (Relay range 2.5-t to 9-13 Amps ) | BI01010001010000000000000515BI0100001159 | 3 | Each |
47 | 12.14 | Thermal Over Load Relay (Auto/Manual reset) suitable for contractors (Relay range 23-32 to 30-40 Amps ) | BI01010001010000000000000515BI0100001160 | 4 | Each |
48 | 12.15 | PVC connector 15 to 60 Amps | BI01010001010000000000000515BI0100001161 | 20 | Each |
49 | 12.16 | Electronic Timers 110/240/360/415Volts 50 Hz for (3-10/ 9-30/36-120 Sec) | BI01010001010000000000000515BI0100001162 | 2 | Each |
50 | 12.17 | Single phase preventer suitable for 3 HP to 25 HP Elect motor sets (Make Minilic) | BI01010001010000000000000515BI0100001163 | 3 | Each |
51 | 12.18 | R/Y/B Phase/On/Trip indicating lamps (as per colour code) | BI01010001010000000000000515BI0100001164 | 10 | Each |
52 | 12.19 | Relay (Salzer Mkg 3P) | BI01010001010000000000000515BI0100001165 | 2 | Each |
53 | 12.2 | S/F thermostat expansion valve make- SPORLON / ALCO type HVE -16 CP 100 suitable for capacity up to 18 TR. | BI01010001010000000000000515BI0100001166 | 1 | Each |
54 | 13 | M&L for replacement of Unsv HEPA filters 0.3 Micron, flanged type EU-13, having Aluminum MOC casing, imported submicron glass fibber paper filter media , filtration efficiency 99.997% down to 0.3 micron, of size 610x610x545x545x305mm, Air flow 2000CFM , 25mm WC initial pressure drop & 60mm WC final pressure drop complete all as specified and directed. \nMake:- Spectrum Filtration / Dina Filter Pvt Ltd/ United filters/National Filter | BI01010001010000000000000515BI0100001167 | 3 | Each |
55 | 14 | M&L for replacement of Unsv HEPA filters 0.3 Micron, flanged type EU-13, having Aluminum MOC casing, imported submicron glass fibber paper filter media , filtration efficiency 99.997% down to 0.3 micron, of size 610x305x545x240x305mm, Air flow 1000CFM , 25mm WC initial pressure drop & 60mm WC final pressure drop complete all as specified and directed. \nMake:- Spectrum Filtration / Dyna Filter Pvt Ltd/ United filters/National Filter | BI01010001010000000000000515BI0100001168 | 3 | Each |
56 | 15 | M&L for replacement of Unsv flanged type combination filter EU4+EU-5 grade, having Aluminum MOC casing, HDPE+NW+AL Mesh filter media , filtration efficiency 95% down to 5 Micron, size 305x610x240x545x380mm, Air flow 1000CFM , 10.5-12.5mm WC initial pressure drop &45mm WC final pressure drop complete all as specified and directed. \nMake:- Spectrum Filtration / Dyna Filter Pvt Ltd/ United filters/National Filter | BI01010001010000000000000515BI0100001169 | 3 | Each |
57 | 16 | Testing of clean room-05 nos & Passage 01 Nos , Laminar flow table-04 Nos , Luminar flow tent-01 for verify the clean room requirement as per ISO- 8 in operation complied as per ISO- 14644. Testing of clean rooms shall be carried out through testing equipments meeting the requirement of ISO 21501-4-2007 and calibrated from National Institute of Standard and Technology (NIST) only.\n Note: (i) Test report to be submit in triplicate.\n(ii) Testing shall be carried out through ISO 9001.205 Certified company | BI01010001010000000000000515BI0100001170 | 2 | Each Job |
58 | 17 | M&L for replacement of strip heaters 3 KW consisting of stainless steel sheathing having heat resistant chrome-nickel 80/20 element protected under best insulation to avoid the leakage of current and with screwed type terminal at one end, 240 volts, AC, 50Hz, single phase complete including taking out existing Unsv heater from duct, AHUs complete all as specified and directed. \nMake: Daspass/Rapid Cool | BI01010001010000000000000515BI0100001171 | 5 | Each |
59 | 18 | M&L for Half yearly servicing of (2x 100 TR Running + 1x 100 TR as standby) screw type water cooled chiller unit by authorised OEM service Engineer including cleaning of electric control panel & its parts, chiller units parts, checking all parameters of Microprocessor, MPD, VRF and other controls including repairing of PCB /MPD/VRF if reqd and setting the parameters as per design and outside conditions, decaling of condenser top up of refrigerant gas, oil if required and submission of service report to Engr in Charge.\nMake of installed AC plant-Voltas Model- ACEGWFXR1001MLC242 \nNote: Refrigerant gas & oil shall be measured and paid in respective item. | BI01010001010000000000000515BI0100001172 | 2 | Each Job |
60 | 19 | M&L for replacement of Unsv rubber star coupling of back pull out type pump set including making proper alignment and greasing of the pump & motor complete all as specified and directed. | BI01010001010000000000000515BI0100001173 | 2 | Each |
61 | 20 | Replacement of Unsv humidistat with digital type humidistat with controller and wire to monitor humidity including interlocking with humidifier & dehumidifier complete all as specified and directed. \nMake : Sub Zero/Honey well | BI01010001010000000000000515BI0100001174 | 5 | Each |
62 | 21 | M&L for replacement of Unsv flow switch of chiller/condenser water line as per existing type & model complete all as specified & directed by Engr in Charge | BI01010001010000000000000515BI0100001175 | 2 | Each |
63 | 22 | M&L for replacement of defective sprinkler assy of complete as per existing type & model of cooling tower cap 40 to 60 TR | BI01010001010000000000000515BI0100001176 | 1 | Each Job |
64 | 23 | M&L for servicing of pan type humidifier by cleaning of internal tank, checking of all electrical & electronics parts & repair of the defective parts complete all as specified and directed. | BI01010001010000000000000515BI0100001177 | 2 | Each |
65 | 24 | M&L for outside duct thermal insulation class 'O ' nitrile rubber based thermal insulation 6mm thick with treated woven glass fiber covering of 0.18mm thick, density of 200+20 GSM, Tensile strength 275+-25 Kg/mm for exposed to sun application (green colour) including fixing with adhesive which is specifically formulated for duct insulation which shall be free from benzene and joints shall be fixed with glass cloth foil based tape with self adhesive ability to ensure 100% leak proof, complete all as specified by OEM & directed by Engineer-in-Charge.\nMake - Armacell/Vidoflex/Eurobatex.\nNote: Rates quoted are deem to be included for necessary temp staging reqd for fixing of insulation nothing extra shall be paid. | BI01010001010000000000000515BI0100001178 | 300 | Sqm |
66 | 25 | M&L for carefully painting on central AC plant water cooled type having condenser, Cooling tower, condenser water pipe line, refrigerant pipe line, control sluice valve/butter fly valves, angle iron foundation frames, compressor motor, compressors, drain water MS duct, condenser , chiller monoblock pump sets etc. of central type ac plant complete with two coat of synthetic enamel paint after scrapping out existing rusted/bubbled paint as per existing colour coding and marking water flow directions with suitable size arrow mark complete including cleaning the stains of paint after painting complete all as specified and directed. \nNote :- for measurement one complete plant taken as one job | BI01010001010000000000000515BI0100001179 | 2 | Each Job |
67 | 26 | M&L for servicing of humidifier Model No RM-2 &RM-3 including cleaning the pre filters, tank etc. complete all as specified and directed. | BI01010001010000000000000515BI0100001180 | 13 | Each |
68 | 27 | M&L for replacement of unsv Pre filter assembly complete as per existing model & make | BI01010001010000000000000515BI0100001181 | 5 | Each |
69 | 28 | M&L for replacement of unsv control module card with relay 220 V of humidified Model No RM2/3 of Rapid cool complete all as specified and directed. | BI01010001010000000000000515BI0100001182 | 1 | Each |
70 | 29 | M&L for replacement of unsv digital humidistat with controller of humidified As per existing make & model complete all as specified and directed. | BI01010001010000000000000515BI0100001183 | 3 | Each |
71 | 30 | M&L for replacement of unsv timer 220V of humidified Model No RM-2/3 complete all as specified and directed. | BI01010001010000000000000515BI0100001184 | 2 | Each |
72 | 31 | M&L for replacement of contactor MR-11W of humidifier model No RM-2/3 complete all as specified and directed. | BI01010001010000000000000515BI0100001185 | 2 | Each |
73 | 32 | M&L for replacement of 48V step down transformer as per existing make & Model of humidified Model No RM-2/3 complete all as specified and directed. | BI01010001010000000000000515BI0100001186 | 1 | Each |
74 | 33 | M&L for replacement of unsv cut out switch of humidifier Model No RM-2/3 complete all as specified & directed | BI01010001010000000000000515BI0100001187 | 1 | Each |
75 | 34 | M&L for replacement of motorised valve with timer for auto flashing of humidifier Model No RM-2/3 complete all as specified and directed. | BI01010001010000000000000515BI0100001188 | 1 | Each |
76 | 35 | Servicing of air shower for 2 persons by checking all electrical connection, replacing u/s wire, lugs, washers, sensors, push button, indicators, cleaning pre filters, blower motor servicing, oiling, etc. by service engineer complete all as specified and directed | BI01010001010000000000000515BI0100001189 | 10 | Each |
77 | 36 | M&L for replacement of unsv Doormat magnetic switch of air shower complete all as specified and directed. | BI01010001010000000000000515BI0100001190 | 2 | Each |
78 | 37 | M&L for replacement of unsv hydraulic Door closer assembly of air shower complete all as specified and directed. | BI01010001010000000000000515BI0100001191 | 2 | Each |
79 | 38 | Repair/replacement of Printed circuit board of air shower for 2 persons taking down and re-fixing of the same complete all as specified and directed. | BI01010001010000000000000515BI0100001192 | 2 | Each |
80 | 39 | Replacement of Unsv Emergency release switch as per existing model complete all as specified & directed | BI01010001010000000000000515BI0100001193 | 2 | Each |
81 | 40 | REPAIR AND MAINTENANCE OF COOLING APPLIANCES, SPLIT TYPE AC, WINDOW AC, WATER COOLER, REFRIGERATOR, DEEPFREEZER, DESERT COOLER, VOLTAGE STABILIZERS AND MISC ITEMS AT 9 BRD AF STATION PUNE.\nM&L for Servicing, cleaning of complete unit (indoor and out door) of air cooled split type AC any capacity by using blower, cleaning of condenser coil with water, checking all the parts, electrical connection , cleaning the air filters, combing of fins by using fins comb including replacing defective filters, burnt wiring, tightening of electric wiring connections, etc., complete all as specified and directed. | BI01010001010000000000000515BI0100001194 | 165 | Each Job |
82 | 41 | M&L for replacement of micro processor printed circuit board complete suitable for split type ACs as suitable for existing make/model up to 2 TR Cap complete all as specified and directed. | BI01010001010000000000000515BI0100001195 | 15 | Each |
83 | 42 | M&L for taking out the motor from swinging system of AC any type of indoor unit with rubber roller and replacing with new motor of suitable for the existing make/model and capacity complete all as specified and directed. | BI01010001010000000000000515BI0100001196 | 10 | Each |
84 | 43 | M&L for replacement of hermetically sealed unit with new Compressor by dismantling any taking out the old u/s burnt out Compressor of split type Air Conditioner, including replacement of bushes, sleeves, washers nut and bolt, relay terminal cover, clips reqd for fixing of new compressor including cutting, brazing of copper piping, charging of suitable refrigerant gas as required Qty to obtained desired cooling, carry out leak test etc., all as required at site complete commissioning, testing for the following capacity:- \nMake: Kirloskar/ Samsung/Voltas/Blue star/Carrier | BI01010001010000000000000515BI0100001197 | ||
85 | 43.01 | Capacity 1.5 TR | BI01010001010000000000000515BI0100001198 | 8 | Each Job |
86 | 43.02 | Capacity 2.0 TR | BI01010001010000000000000515BI0100001199 | 6 | Each Job |
87 | 44 | M&L for replacement of existing old U/S insulation of refrigerant pipes of split air conditioner up to 2 TR cap complete all as specified and directed. | BI01010001010000000000000515BI0100001200 | 30 | Each Job |
88 | 45 | M&L taking out defective micro processor printed circuit board of split type AC of existing Make/Model up to 3 TR Capacity for repair and refixing to its original place after carry out necessary repair and testing complete all as specified and directed. | BI01010001010000000000000515BI0100001201 | 20 | Each |
89 | 46 | M&L taking out defective micro processor printed circuit board of split type AC of existing Make/Model up to 3 TR Capacity for repair and refixing to its original place after carry out necessary repair and testing complete all as specified and directed. | BI01010001010000000000000515BI0100001202 | ||
90 | 46.01 | Split type AC 1.5 TR capacity | BI01010001010000000000000515BI0100001203 | 30 | Each |
91 | 46.02 | Split type AC 2.0 TR Capacity | BI01010001010000000000000515BI0100001204 | 30 | Each |
92 | 47 | M& L for replacement of condenser fan/blower motor as per existing make and model suitable for following Capacity including testing after replacement complete all as specified and directed. | BI01010001010000000000000515BI0100001205 | ||
93 | 47.01 | Motor suitable for 1.5 TR Capacity | BI01010001010000000000000515BI0100001206 | 6 | Each |
94 | 47.02 | Motor suitable for 2.0 TR capacity | BI01010001010000000000000515BI0100001207 | 6 | Each |
95 | 48 | M&L for replacement of unserviceable fan blade of condenser unit of split type AC up to 2 TR as per existing make and model complete all as specified and directed. | BI01010001010000000000000515BI0100001208 | 10 | Each |
96 | 49 | M& L for replacement of unserviceable hermetically sealed compressor with new Compressor suitable for window type AC of following capacity, including replacement of unserviceable bushes, sleeves, washers nut and bolt for 4/3 Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging of suitable refrigerant gas as required to obtained desired cooling, carry out leak test etc., all as required at site complete commissioning, testing for the following capacity\n Note: Make of compressor:-Kirloskar/Emerson/ Copeland/Tecumseh/Carrier | BI01010001010000000000000515BI0100001209 | ||
97 | 49.01 | Compressor suitable for 1.5 TR Capacity | BI01010001010000000000000515BI0100001210 | 2 | Each |
98 | 49.02 | Compressor suitable for 2.0 TR capacity | BI01010001010000000000000515BI0100001211 | 2 | Each |
99 | 50 | M&L for servicing, cleaning of window type AC's of capacity 1.0/1.5/ 2.0 TR by blower, cleaning condenser coil with water, combing fins including replacement of defective filter, selector knobs, burnt wiring , tighten, checking of electrical connections etc. complete up to satisfaction of Engr in charge. | BI01010001010000000000000515BI0100001212 | 20 | Each |
100 | 51 | M&L for leak detection in refrigerant system of AC by using nitrogen pressure test, cutting brazing, making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas as required quantity to achieve desire cooling complete all as specified and directed. | BI01010001010000000000000515BI0100001213 | ||
101 | 51.01 | Window type AC 1.5 TR capacity | BI01010001010000000000000515BI0100001214 | 4 | Each |
102 | 51.02 | Window type AC 2.0 TR Capacity | BI01010001010000000000000515BI0100001215 | 3 | Each |
103 | 52 | M&L for replacement of unserviceable electric blower motor suitable for 1/1.5 /2TR capacity window type AC double speed, single phase 230 volt 50 Hz, complete all as specified and directed. \n Make - Gulmarg/AUE or as per existing make/ type. | BI01010001010000000000000515BI0100001216 | 4 | Each |
104 | 53 | M&L for replacement of unserviceable running capacitor 30/36/40/45/55 mfd suitable for split/window type AC's 1 to 3 TR cap of existing make & model complete all as specified and directed. | BI01010001010000000000000515BI0100001217 | 60 | Each |
105 | 54 | M&L for replacement of capacitor 4/6 mfd suitable for fan motor of (split/window /water cooler/Desert cooler fan motor) complete all as specified and directed. | BI01010001010000000000000515BI0100001218 | 50 | Each |
106 | 55 | M&L for replacement of unserviceable thermostat switch suitable for water coolers, Window type AC's /split AC's, refrigerators and Deep freezers any capacity, make & model complete all as specified and directed. | BI01010001010000000000000515BI0100001219 | 10 | Each |
107 | 56 | M&L for replacement of starting relay suitable for water coolers, Window type AC's /split AC's, refrigerators and Deep freezers any capacity, make & model complete all as specified and directed. | BI01010001010000000000000515BI0100001220 | 15 | Each |
108 | 57 | M&L for replacement of valves suitable for suction and discharge line of refrigerant and taking out the u/s valves of split AC's of capacity 1.5TR/ 2.0 TR and complete all as specified and directed. | BI01010001010000000000000515BI0100001221 | 12 | Each |
109 | 58 | M&L for replacement of Unsv 1/6 HP electric motor suitable for 1.0/1.5 TR/2.0 TR capacity window type AC double speed, single phase 230 volt, 50 Hz, including taking out the old US motor and complete all as specified and directed. \nMake - Gulmarg/AUE | BI01010001010000000000000515BI0100001222 | 5 | Each |
110 | 59 | M&L for replacement of unserviceable submersible water pump suitable for desert cooler 4000/5000/ Cfm | BI01010001010000000000000515BI0100001223 | 20 | Each |
111 | 60 | M&L for replacement of Khas pad set of best quality suitable for 4000/5000 CFM desert cooler any make and type as specified and directed | BI01010001010000000000000515BI0100001224 | 20 | Set of three |
112 | 61 | M&L for replacement of Unsv exhaust fan motor double speed single phase 230 volt 50 Hz 1460 RPM suitable for desert coolers 4000/5000 Cfm capacity | BI01010001010000000000000515BI0100001225 | 10 | Each |
113 | 62 | S&F push cock of 15 mm dia for water cooler and taking out the unserviceable push cock and complete all as specified and directed. | BI01010001010000000000000515BI0100001226 | 10 | Each |
114 | 63 | M&L for replacement of float valve suitable for water cooler (40/60/120/150 Ltrs) capacity any make complete all as specified and directed. | BI01010001010000000000000515BI0100001227 | 5 | Each |
115 | 64 | Supply and fix hermetically sealed unit new Compressor by dismantling burnt out u/s Compressor suitable for water coolers of following capacities including provn of bushes, sleeves, washers nut and bolt for 4/3 Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing for the following capacity:-\nMake : Kirloskar/Emerson climate Technologies (India) Ltd/Voltas/Blue star | BI01010001010000000000000515BI0100001228 | ||
116 | 64.01 | Cooling capacity 40 Ltrs/Hr | BI01010001010000000000000515BI0100001229 | 3 | Each |
117 | 64.02 | Cooling capacity 60 Ltrs/Hr | BI01010001010000000000000515BI0100001230 | 2 | Each |
118 | 64.03 | Cooling capacity 120/150 Ltrs/Hr | BI01010001010000000000000515BI0100001231 | 2 | Each |
119 | 65 | Servicing of air curtain up to 6 feet, single phase, 240V by checking all electrical connection, blower, motor oiling greasing and replacement of u/s wire, lugs, bushes, rubber pads, bearing etc. complete all as specified and directed. | BI01010001010000000000000515BI0100001232 | 6 | Each |
120 | 66 | Supply and fix hermetically sealed unit new Compressor by dismantling burnt out u/s Compressor suitable for refrigerators including provn of bushes, sleeves, washers nut and bolt for 4/3 Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing for the following capacity.\nMake : Kirloskar/Emerson climate Technologies (India) Ltd/Voltas/Blue star | BI01010001010000000000000515BI0100001233 | ||
121 | 66.01 | 165 - 200 Ltr capacity | BI01010001010000000000000515BI0100001234 | 2 | Each |
122 | 66.02 | 285 - 300 Ltr capacity | BI01010001010000000000000515BI0100001235 | 1 | Each |
123 | 67 | M&L for leak detection in refrigerant system of Refrigerator (165 to 300 Ltrs cap) including cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas as required quantity complete all as specified and directed | BI01010001010000000000000515BI0100001236 | 2 | Each |
124 | 68 | Replacement of unsv Blower belts of air shower as per existing size and model complete all as specified and directed. | BI01010001010000000000000515BI0100001237 | 6 | Each |
125 | 69 | Taking down of u/s and S&F sheet metal enclosure with socket plug top and MCB, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240V 20 amps\nMake: Standard/Havel's or equivalent make. | BI01010001010000000000000515BI0100001238 | 10 | Each |
126 | 70 | Replacement of over load protection for Window/split type AC of any capacity. | BI01010001010000000000000515BI0100001239 | 5 | Each |
127 | 71 | Taking down of old u/s and S&F of PVC pipe 15 mm dia flexible water pipe with distributor, 3 way suitable for desert cooler, complete all as specified and directed. | BI01010001010000000000000515BI0100001240 | 10 | Each |
128 | 72 | M&L for replacement of drain pipe of Split type AC up to 2 TR cap and length as required at site complete all as specified and directed. | BI01010001010000000000000515BI0100001241 | 20 | Each |
129 | 73 | M&L for replacement of unsv condenser cooling coils of Split type AC up to 2 TR cap with new copper coil including taking out unsv condenser coil complete all as reqd at site and complete all as specified and directed. | BI01010001010000000000000515BI0100001242 | 10 | Each Job |
130 | 74 | Taking out existing split type air conditioners of any type and capacity removing from the site and keeping it in a safe custody for re-use or deposit in store complete all as specified and directed. | BI01010001010000000000000515BI0100001243 | 4 | Each |
131 | 75 | Fixing only split type air conditioners of any type and capacity including core cutting for passing copper tubing , drain pipe & cable through stone masonry wall with connected accessories such as bracket, copper tubing, cable from indoor to out door unit and rain water pipe etc. as per site requirement complete all as specified and directed. | BI01010001010000000000000515BI0100001244 | 4 | Each Job |