Periodical Services Including Misc Maint Works To Certain Buildings , Repairs To Leekage/Seepage In Roof , Chajja , Balconies And Repair/Replacement Of Street Light , Oh Conductor , Dbs At Mes , Domestic And Basara Area Including Mes Area Under Ge , GE(AF) HASIMARA-West Bengal

Military Engineer Services-MES has published Periodical Services Including Misc Maint Works To Certain Buildings , Repairs To Leekage/Seepage In Roof , Chajja , Balconies And Repair/Replacement Of Street Light , Oh Conductor , Dbs At Mes , Domestic And Basara Area Including Mes Area Under Ge . Submission Date for this Tender is 07-06-2021. Street Lighting Tenders in GE(AF) HASIMARA West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

27908405
Corrigendum : Periodical Services Including Misc Maint Works To Certain Buildings , Repairs To Leekage/Seepage In Roof , Chajja , Balconies And Repair/Replacement Of Street Light , Oh Conductor , Dbs At Mes , Domestic And Basara Area Including Mes Area Under Ge
Open Tender
Indian
West Bengal
GE(AF) HASIMARA
07-06-2021

Tender Details

Periodical Services Including Misc Maint Works To Certain Buildings , Repairs To Leekage/Seepage In Roof , Chajja , Balconies And Repair/Replacement Of Street Light , Oh Conductor , Dbs At Mes , Domestic And Basara Area Including Mes Area Under Ge ( Af ) Has

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-May-2021 CORRIGENDUM TO TENDER Other 07-06-2021
2 28-May-2021 CORRIGENDUM TO BOQ BOQ 07-06-2021
3 28-May-2021 CORRIGENDUM TO BOQ BOQ 07-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
Refer document

BOQ Items

Nature of Work : PERIODICAL SERVICES INCLUDING MISC MAINT WORKS TO CERTAIN BUILDINGS, REPAIRS TO LEEKAGE/SEEPAGE IN ROOF, CHAJJA, BALCONIES AND REPAIR/REPLACEMENT OF STREET LIGHT, OH CONDUCTOR, DBs AT MES, DOMESTIC & BASARA AREA INCLUDING MES AREA UNDER GE (AF) HASIMARA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M & L for preparing old decorated surfaces of walls, etc including cornices by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed. 1000 Sqm
2 2 M & L for preparing old decorated surfaces of ceiling, etc by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed. 500 Sqm
3 3 M & L for preparing old decorated surfaces of wall/chajja, etc including cornces by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of cement base paint complete all as specified and directed. 5000 Sqm
4 4 M & L for preparing old decorated surfaces of wall, etc including cornces by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of distemper oil emulsion complete all as specified and directed. 8000 Sqm
5 5 M & L for preparing old decorated surfaces of ceiling, etc including cornces by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of distemper oil emulsion complete all as specified and directed.\n 500 Sqm
6 6 M & L for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of alkali resistant priming coat complete all as specified and directed. 500 Sqm
7 7 M & L for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of chalk whitening over one or more coat of wall care putty complete all as specified and directed.\n 4200 Sqm
8 8 M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed. 500 Sqm
9 9 M & L for Preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. 1500 Sqm
10 10 M & L for Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed. 300 Sqm
11 11 M & L for preparing old decorated surfaces of wall, etc including cornces by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of Plastic emulsion paint complete all as specified and directed. 300 Sqm
12 12 M & L for preparation old decorated external surfaces of wall, chajja, facia etc and applying one coat of water based acrylic weather proof exterior emulsion (exterior wall finish) paint complete all as specified and directed. 2500 Sqm
13 13 M & L for Obliterating old writing of any description, n exc 0.1 sq. m, with paint to match existing work with synthetic enamel paint complete all as specified and directed. 30 Each Job
14 14 M & L for Writing letters or figures (Block ,Roman, Italic or Indian) n. exc 30 cm height with synthetic enamel paint complete all as specified and directed. 20 Per 10 Nos per CM of height
15 15 M & L for Writing stops, commas, short lines , dashes, hyphens, brackets, etc with synthetic enamel paint complete all as specified and directed. 20 Per 10 Nos
16 16 M & L for Preparation of old treated steel surfaces of roof of any description over 10 cm girth or width and applying one coats of antisol roof paint complete all as specified and directed. 1200 Sqm
17 17 M & L for preparation & cleaning of old polished wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying one or more coat of french polish complete all as specified and directed. 50 Sqm
18 18 M & L for cleaning all exposed surfaces of bolts, nuts and washer and connected sufaces of CGI/PGI/AC roof sheet, sanding all surface by emmary paper throughly to remove rust, dust etc, finally cleaning the surfaces by cotton cloth and applying apoxy based roof repairing compound (Make: Sikflex of Sika India or equivelant approved make) to cover all the cleaned surfaces and gap between roof sheet and washer with thickness not less than 2mm and applying touch up painting with two coats of synthetic enamel paint after drying complete all as specified and directed. (Note: Roof repairing comound shall be applied only after cleaning the bolts, nuts, washer and connected surfaces of roof sheet to the entire satisfaction of Engr-in-Charge.) 7400 Each
19 19 Removing detoriated tarfelt/bitumenous felt from CGI sheet roof including removing bitumenous orimer by wire brushing etc and finally grinding the surfaces by emmary paper to remove all rust and dirt and removing the debries from site of work as directed by the Engr-in-Charge complete all as specified and directed. 1500 Sqm
20 20 M & L for preparing old damp painted surfaces of wall including complete removal of existing treatment and applying two coats of raincoat paint over a coat of anti efflorscence primer (Make: Dr Fixit or equivelant make as approve) without diluting the paint all as per manufacturer's instruction complete all as specified and directed. 1000 Sqm
21 21 M & L for preparing old damp painted internal surfaces of wall including complete removal of existing treatment and applying washing coat of one part vinegar to eight part of warm water to remove salt etc and applying two coats of dampguard paint over a coat of Pidiseal anti efflorscence salt primer (Make: Dr Fixit or equivelant make as approve) to make the surfaces completely dry all as per manufacturer's instruction complete all as specified and directed. 1000 Sqm
22 22 Cleaning and removing all scale and dirt, etc, from tanks of capapcity exc 250 & n.exc 500 Ltrs and from mouths of circulating pipes, etc. using bleaching powder and washed with water including dismantling and reconnecting and refixing in psoition including writing date of cleaning with nwhite synthetic enamel paint as "CLEANDED ON" complete all as specified and directed. 100 Each
23 23 Cleaning and removing all scale and dirt, etc, from tanks of capapcity exc 500 & n.exc 1000 Ltrs and from mouths of circulating pipes, etc. using bleaching powder and washed with water including dismantling and reconnecting and refixing in psoition including writing date of cleaning with nwhite synthetic enamel paint as "CLEANDED ON" complete all as specified and directed. 55 Each
24 24 S & F in repairs, 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed. 50 Each
25 25 S & F 15 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 142 gms) complete all as specified and directed. 30 Each
26 26 Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.\n 300 RM
27 27 Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. 220 RM
28 28 Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. 290 RM
29 29 Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. 210 RM
30 30 Refixing of 15mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 26 above) 10 RM
31 31 Refixing of 20mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 27 above) 10 RM
32 32 Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge. 13 Cum
33 33 M & L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.\n 12.5 Cum
34 34 M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete all as specified and directed. 21 Sqm
35 35 Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed 950 Sqm
36 36 M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). 550 Sqm
37 37 Supply only Liquid water proofing compound (ISI marked) complete all as specified and directed. 95 Ltr
38 38 M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. 300 Sqm
39 39 M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and directed. 100 Sqm
40 40 M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed. 500 Sqm
41 41 M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.\n 100 Sqm
42 42 M & L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and directed.\n 300 Sqm
43 43 M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed. 150 Sqm
44 44 Demolition of reinforced cement concrete in any position not otherwise specifically provided for complete all as specified and directed. 20 Cum
45 45 Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance n.exc 100m complete all as directed by the Engr-in-Charge 7.5 Cum
46 46 S & F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to cerntre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete including Hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including 4 mm thick, Non asbestos fibre cement building boards as in ceiling fixed with screws as per manufacturers instructions after dismantling of old unserviceable ceiling complete all as specified and directed by the Engr-in-Charge. 75 Sqm
47 47 M & L Water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- \n(a) Taking down existing old tarfelt, bituminous compound including cleaning, picking, sweeping and washing down with water and brushing with neat cement slurry & 3 Kg per Sqm & removing debris (b) 15 mm thick plastering in cement mortar 1:3 mixed with water proofing compound (to be measured seperately) as per manufacturer instructions finished even & smooth. \n(c) Preparing & cleaning of fully dried cement plastered surface. \n(d) Applying one coat of cold bituminous primer to the plastered surface @ 300 ml per sqm conforming IS-3384 \n(e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. \n(f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm 350 Sqm
48 48 Dismantling of Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings with ridges complete all as specified and directed. 175 Sqm
49 49 S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed. 150 Sqm
50 50 S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed. 25 Sqm
51 51 S & F in repairs, 20 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. 5 Each
52 52 S & F 100mm bore, Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. 25 Each
53 53 M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.\n 250 Sqm
54 54 Material and labour for 25 mm thick pre-polished cement concrete chequered tiles, glossy finish , smooth in design , compressive strength 300 kg/Sqcm, ISI marking (IS-13801-1993), set, jointed in neat cement slurry and pointed with white cement mixed with pigment to match over and including 20mm thick scread bed in cement mortar 1:6 complete all as specified and directed 120 Sqm
55 55 Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.\n 2.5 Qtl
56 56 M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed. 250 KG
57 57 M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. 45 Sqm
58 58 M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection/sub base/ hard standing etc, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. 100 Sqm
59 59 S & F in repair 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. 225 RM
60 60 S & F in repair 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. 24 Each
61 61 S & F 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed. 10 Each
62 62 S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed. 5 Each
63 63 Taking down street light fittings/flood lights of any type any capacity from existing pole after disconnecting all electrical connections and removing from the site complete all as specified and directed. 36 Each Set
64 64 S & F in repair Street light bracket arm of length not less than 1.2 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.\n\n\n 20 Each
65 65 Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed. 243 Cum
66 66 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. 146 Cum
67 67 Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. 97 Cum
68 68 Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed. 7000 Each
69 69 M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.\n(Note: Thickness after punning down shall be measured for payment) 73 Cum
70 70 M & L for boring of horizontally holes by manual method under road below 1 metre from the road surface and dia of hole not exc 100mm without damaging the exsting road, getting out and disposal of excavated soil, etc to a distance not exc. 50 meter from the site of work complete all as directed by Engineer in charge. 20 RM
71 71 M & L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors including taking up or down existing pipe complete all as specified and directed. 40 RM
72 72 Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core including taking out old one complete all as specified and directed. (Note: Excvation and earth work shall be measured and paid seperately) 200 RM
73 73 All as per serial item No. 72 above but for 10 Sqmm 4 core cable complete all as specified and directed. 300 RM
74 74 All as per serial item No. 72 above but for 16 Sqmm 4 core cable complete all as specified and directed. 300 RM
75 75 All as per serial item No. 72 above but for 25 Sqmm 3.5 core cable complete all as specified and directed. 200 RM
76 76 M & L for disconnecting burnt end or portion of UG cable, removing the cable from loop including necessary excavation and earth work, relaying and re-connecting the cable by removing burnt protion of cable and preparing fresh terminals for cable of cross sectional area 10 Sqmm 2 core to 95 Sqmm 3.5 core of LT cable to pole main switch etc complete all as specified and as directed by the Engr-in-Charge. \n 8 Each Job
77 77 M & L for plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in benching, coping, bed plate, lintel upto 1.5m span cast in situ including necessary form work complete all as specified and directed.\n 10 Cum
78 78 Supply, installation, testing and commissioning factory fabricated feeder pillar (outdoor type) weather dust and vermin proof fabricated out of 3.15 mm thick CRCA steel sheet outer portion AC 415 volts, 50 HZ of size 600 mm x 400 mm x 300 mm mounted on PCC foundation and inner portion of size 2.0 mm thick suitable size of MS channel supports and with suitable size of angle iron legs for grouting steel sheet powder coated paint internally & externally and locking arrangement including all incoming and outgoing connection with suitable size of lugs and glands and dismantling existing unserviceable panel with and including the following complete all as specified and directed.:-\n(a) 04 Nos aluminium busbar 3 phase 4 wire of rating 200 amps for phase and neutral. 4 Each
79 79 S & F PVC KIOSK box, weather proof, made out of one piece mounted SMC base and door pole mounted hinged door, size 333 x 233 x 200mm (out side) and 300 x 200 x 105mm (inside), comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp & 10 Amp MCB for controlling the street light fitting including FI clamps 30 x 4 mm with necessary MS nuts bolts and washer including embossing/painting of Danger notice of size not less than 10 cm x 7.5 cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as directed.( Make : Sintex / Hensal / Universal / Finolex) 50 Each
80 80 S & F in repair powder coated street light feeder panel with IP65 protection for outdoor application, modular changeover functions as auto manual bypass of time switch, digital Astro time switch to adjust time, 16 module enclosure, one MCB 4 pole 10 KA capacity 40 Amp, one MCB type change over 25amp, 2P, 250V, one contactor 40A 230V including 4 pole surge protection device including locking arrangement, glands and lugs etc and fixed to pole with nuts bolts washers etc complete all as specified and directed. (Make : Hager/Havell's/Aristo and equivalent model of make as specified in list of manufacturer). 3 Each
81 81 Supply & fixing in repair astronomical time switch in existing street light timer panel for switching on /off lights and other electric devices according to the Sunrise & sunset time based on the entered location or location coordinates complete all as specified and directed. (Make : Legrand, Model No AlphaRex3 D21 astro, 1 channel or equivalent) 2 Each
82 82 S & F LED street light fittings, 45 Watt in aluminium PDC housing toughened glass cover with IP 66 protection including lamp and connecting up and testing complete all as specified and directed. (Make : Surya Cat No. SLE UL 45W IP66 LXN and equivalent model of make as specified in list of manufacturer). 12 Each
83 83 S & F LED street light fittings, 60 Watt in aluminium PDC housing toughened glass cover with IP 66 protection including lamp and connecting up and testing complete all as specified and directed. (Make : Surya Cat No. SLE UL 60W IP66 LXN and equivalent model of make as specified in list of manufacturer). \n 12 Each
84 84 S & F energy efficient LED flood light fittings, 75 Watt with pressure die cast aluminium housing with IP 66 protection complete with all accessories including lamp and connecting up and testing complete all as specified and directed. (Make : C & S Cat No. LTEFI75WHPLED and equivalent model of make as specified in list of manufacturer). 4 Each
85 85 S & F LED flood light fittings, 60 Watt with high luminous afficacy with front toughened glass cover with IP 65 protection including lamp and connecting up and testing complete all as specified and directed. (Make : Surya Cat No. SLE FL 60W IP65 RFLOOD and equivalent model of make as specified in list of manufacturer). 4 Each
86 86 S & F LED flood light fittings, 200 Watt with highly efficient LEDs, long life with front toughened glass cover, die cast, environment friendly including lamp and connecting up and testing complete all as specified and directed. (Make : Havells Cat No. JETAVALOURFL200WLED757PINTNBLTG and equivalent model of make as specified in list of manufacturer). 4 Each
87 87 S & F in repairs, three core twisted, flexible copper conductor wire of size 1.00 Sqmm for connection complete all as specified and directed. 200 RM
88 88 M & L for making hole by gas flame of appropriate size in street light steel pole (02 Nos per pole) for passing the connection wire etc from junction box to street light complete all as specified and directed. 20 Each Job
89 89 S & F sheet metal enclosure, double door MCB DBs, phosphatised, powder coated, single pole & neutral (SPN), 08 way, 240 Volts suitable for housing MCBs with din rail, neutral and earth bar in proper psoition complete all as specified and directed. (Make : Legrand, Cat No. 5076 11 or equivalent model as approved) 6 Each
90 90 S & F MCB, SPN, 240 Volts, 6 to 32 Amps, 'C' series, 10KA capacity complete all as specified and directed. (Make: Legrand Cat No. 4086 14 - 17 or equivalent of make as per list of manufacturer) 6 Each
91 91 S & F MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and directed. (Make: Legrand, Cat No. 4085 87-95 or equivalent make as per list of manufacturer) 36 Each
92 92 M & L for Sub main wiring with two runs of 6 sqmm (Nominal area) single core cable FR PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through and including concealed PVC conduits/casing-caping of suitable size including 6 sqmm (nominal area) single core, FRLS PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size and taking down old unserviceable sub main wiring complete all as specified and as directed by Engineer-in-charge. (Note : (i) PVC Conduits/Casing-caping, two run cables and one run of earth wire will be measured as one length (ii) Cutting chases and making good the same for concealed wiring shall be meaured and paid seperately.) 200 RM
93 93 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but n.exc 20 cm girth complete all as specified and directed. 200 RM
94 94 S & F in repair wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED lamp, 18 Watt and connecting up complete all as specified and directed. (Make : Surya/Havells/ Crompton/Bajaj). 50 Each
95 95 M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.\nNote: An amount of Rs. 48505.00 on account of credit schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.\n 4 Each Job
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy