Repairs And Maintenance Of Ht Lt Ug Cables Distribution Transformers Servo Voltage Stabilizers Switchgears Earthing And Repairs To Led Cfl Ftl Mh Lights At Icgas Daman, GARRISON ENGINEER DAMAN-Daman And Diu

Military Engineer Services-MES has published Repairs And Maintenance Of Ht Lt Ug Cables Distribution Transformers Servo Voltage Stabilizers Switchgears Earthing And Repairs To Led Cfl Ftl Mh Lights At Icgas Daman. Submission Date for this Tender is 03-06-2021. Electrification Work Tenders in GARRISON ENGINEER DAMAN Daman And Diu. Bidders can get complete Tender details and download the document.




Tender Notice

27905256
Corrigendum : Repairs And Maintenance Of Ht Lt Ug Cables Distribution Transformers Servo Voltage Stabilizers Switchgears Earthing And Repairs To Led Cfl Ftl Mh Lights At Icgas Daman
Open Tender
Indian
Daman And Diu
GARRISON ENGINEER DAMAN
03-06-2021

Tender Details

Repairs And Maintenance Of Ht Lt Ug Cables Distribution Transformers Servo Voltage Stabilizers Switchgears Earthing And Repairs To Led Cfl Ftl Mh Lights At Icgas Daman

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-06-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIRS AND MAINTENANCE OF HT/LT U/G CABLES , DISTRIBUTION TRANSFORMERS, SERVO VOLTAGE STABILIZERS, SWITCHGEARS, EARTHING AND REPAIRS TO LED, CFL, FTL, MH LIGHTS AT ICGAS DAMAN.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply and fix in repairs on-load change over switch 320 Amps, 4pole, 3 phase, 415V, 50Hz, front handle operated, open execution type in existing panel board after making addition/alterations and connecting of existing cables by providing suitable lugs, nuts,bolts & washers etc, testing after disconnecting electric connection, complete all as specified and directed. 1 1 Each Job
2 2 Supply and fixing in repairs of capacitor bank 20KVAR, MPP type, 415volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed. \nMake :- Epcos/L&T/Schnieder 2 1 Each job
3 3 Supply and fixing in repairs of capacitor bank 15KVAR, MPP type, 415Volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed. \nMake :- Epcos/L&T/Schnieder 3 2 Each Job
4 4 Supply and fixing in repairs of capacitor bank 10KVAR, MPP type, 415volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed. \n Make :- Epcos/L&T/Schnieder 4 3 Each Job
5 5 Supply and fixing in repairs of capacitor bank 5KVAR, MPP type, 415volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed.\nMake :- Epcos/L&T/Schnieder 5 4 Each Job
6 6 Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz Outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, CPRI approved factory fabricated made out of 3.2 mm thick CRCA sheet duly powder coated and shall be as approved by GE. The Panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequate size for MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and Panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) in foundation design subject to approval of GE as per site requirement. The minimum depth, height, width of panel is 450x1800x1500 mm respectively, minimum clearance from ground level is 450mm including removing old unserviceable panel/ item complete all as specified and directed and comprising of following :- \n(a) MCCB 250 Amps adjustable 70-100%,4P, 35/36 KA,415 volts,50Hz-01 No\n(b) MCCB 100 Amps adjustable 70-100%,4P, 16 KA,415 volts,50Hz-06 No \n(c) MCB 40 Amps,FP,10 KA,240 volts,50Hz-02 No \n(d) Digital, voltmeter,Ammeter,with CTs,VSS & ASS-01 set \n(e) LED phase indication lamps RYB-01 set \n(f) Aluminium bus bar TPN 400 Amps rating -01 set\nNote:- (i) Contractor shall provide CPRI certification of factory fabrication . (ii) Make for MCCB :-Schneider/L&T/Legrand/Havells (ISI Marked) .Make for CT :- Nippen/AE , Make of LED Lamp:- Teknic, Make for amp meter and volt ,meter :- AE/Kaycee 6 1 Each Job
7 7 Filtration & Dehydration of transformer oil in distribution transformer, servo voltage stabilizers, isolation tramsformer and HT OCBs (at different locations) using ON-LINE electrically operated filtration plant to achieve dielectric strength minimum 50 KV/ 4mm including testing of oil before and after dehydation and also topping up of the transformer oil upto required level, complete all as specified and directed.\nNote:-(i)Transformer oil supplyng and top-up shall be measured and paid separately.\n(ii) The quoted rates shall also be deemed to include for submission of test reports for testing as specified above \n(iii) Quantity payable under the item shall be the Qty of oil filtered and dehydrated only. 7 2332 Ltr
8 8 Supply only transformer oil conforming to IS 335-1993 (Make : 'Savita', 'Power Oil', APAR) having di-electric strength minimum 50 KV/4mm, complete all as specified and directed. 8 600 Ltr
9 9 Supply and fix in repairs breather assembly including silica gel component suitable for indoor type transformer of 160 KVA to 400 KVA capacity, complete all as specified and directed. 9 3 Each Job
10 10 Material & labour in repairs for HT Danger notice plate of size 25x20 cm made out of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with and including M.S. clamps, bolts and nuts of approved size, complete all as specified and directed. 10 5 Each Job
11 11 Supply and fix in repair 11 KV air break gang operated device of rating 400 amps, 3Pole, vertical type, mechanically operated,mounted on and including 11 KV porcelain insulators and steel frame with operating machanism worked from ground level with and including GI tubing 25 mm bore light grade and providing ACSR conductor jumpers duly crimped with lugs, connected to existing 11 KV supply and testing , complete all as specified and directed. 11 1 Each Job
12 12 Material and labour for high tension lightning arrestor, expulsion type suitable for 11 KV with all fittings of transmission class, discharge capacity 65 Kilo Amps and testing including removing old unserviceable item, complete all as specified and directed. Make :- OBLUM/ELPRO/ATLAS/BHEL. \n 12 2 Per Set of Three
13 13 Supply and fixing in repair drop out fuse unit expulsion type for outdoor air break gang operated switch, single pole, mounted on and including insulators for 11 KV working pressure, fixed to and including channel with nuts, bolts and washers etc,synthetic bounded fuse carrying tube with line taps and suitable for current carrying capacity 25 Amp to 50 Amp, testing including removing of old U/S items, complete all as specified and directed.\nNote for Item Nos 12& 13 : Steel work (channels for GOD)for installation of above items to Pole(s) shall be measured and paid separately. 13 4 Each Job
14 14 Supply & fixing in repairs control fuse unit of capacity 2 Amps with and including HRC fuse and fuse holder as required at site in existing panel boards complete all as specified and directed. 14 4 Each Job
15 15 Supply & fixing in repairs LED phase indicating lamp R Y B colour as required at site in existing panel boards complete all as specified and directed. 15 6 Each Set
16 16 Disconnecting of LT and HT cables carefully from the existing Transformer of capacity 400KVA, 11KV/433 volts of any make/type opening of top cover and decanning of transformer oil, checking of connections internally, tightening of all connections, HT and LT bushing and studs and soldering and brazing the connections including removal of sediments, carbon deposits at bottom of transformer tank, on core, on winding etc, cleaning of oil tank and rectification of leakage problem and renewal of all gaskets and assembling and filling back of tranformer oil including top up of tranformer oil upto required level and testing, complete all as specified and directed. Note:-Transformer oil for top up will be measured and paid separately 16 1 Each Job
17 17 Disconnecting of LT and HT cables carefully from the existing Transformer of capacity 200 to 250 KVA, 11KV/433 volts of any make/type opening of top cover and decanning of transformer oil, checking of connections internally, tightening of all connections, HT and LT bushing and studs and soldering and brazing the connections including removal of sediments, carbon deposits at bottom of transformer tank, on core, on winding etc, cleaning of oil tank and rectification of leakage problem and renewal of all gaskets and assembling and filling back of tranformer oil including top up of tranformer oil upto required level and testing, complete all as specified and directed. Note:-Transformer oil for top up will be measured and paid separately 17 1 Each Job
18 18 Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for primary (HT) side of transformer capacity 400KVA, 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed.\nNote:- This item shall not be applicable for item No 16 & 17. 18 1 Each Job
19 19 Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for primary (HT) side of transformer capacity 200 to 250 KVA, 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed.\nNote:- This item shall not be applicable for item No 16 & 17. 19 2 Each Job
20 20 Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for secondary (LT) side of transformer capacity 400KVA, 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed.\nNote:- This item shall not be applicable for item No 16 & 17. 20 1 Each Job
21 21 Material and Labour for brass terminal studs and bushing with brass check nuts including all accessories for secondary (LT) side of transformer capacity 200 to 250 KVA, 11KV/433 volts of any make/type including removing of old unserviceable items and testing complete all as specified and directed. \nNote:- This item shall not be applicable for item No 16 & 17. 21 2 Each Job
22 22 M&L for prepartion of old paint with electrically operated spray machine surfaces of transformer 200 to 400 KVA capacity, 11KV/433 Volt of any make/type including removing of any oil spillage etc and applying two coats of synthetic emanel paint of shade as per existing, complete all as specified and directed. 22 2 Each Job
23 23 Material and labour for fault finding of LT cables of size 50 to 120 sqmm, 3.5 core and any length with fault detective machine by thumbing method and suitable voltage and all as per manufactures instructions including providing straight through joint and additional cable of same existing size suitable to site requirement complete all as specified and directed. 23 2 Each Job
24 24 Supply only hydraulic oil type HV 132, complete all as specified and directed . 24 20 Litres
25 25 Taking out existing underground defective cable of any type and size from the trenches and from any other locations (including taking out of cable covers, pipes etc) complete all as directed.\n 25 838 RM
26 26 Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 120 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed.\nNote for item No 27 to 32 :- (i) Excavation & Earth work,sand cushioning, cable cover and protection pipe shall be measured and paid separately.\n(ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make of cable:- Polycab/Havells/KEI/Finolex (ISI Marked) 26 50 RM
27 27 Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 70 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed.\n 27 278 RM
28 28 Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 50 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed.\n 28 150 RM
29 29 Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 25 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed.\n 29 110 RM
30 30 Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 6 sqmm,2 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed.\n 30 210 RM
31 31 Supply, laying, testing and commissioning HT cable 11 KV grade, XLPE insulated (earthed) screened, PVC bedded, galvanized iron strip armoured with stranded aluminium conductor cable of cross sectional area 120 sqmm; 3 core, ISI marked with IS:7098 (part-II) as amended upto date in trenches/ ducts/ through pipes etc and making connection by providing suitable aluminium lugs with proper crimping, complete all as specified and directed. 31 40 RM
32 32 S&F cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with and including jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 120 Sqmm, also including connecting with single thimbles etc after disconnecting of electric supply including removing burnt out jointing kit etc, complete all as specified and directed. 32 1 Each Job
33 33 S&F cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint, complete with and including jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 120 Sqmm, also with and including connecting single thimbles etc after disconnecting of electric supply including removing burnt out jointing kit etc, complete all as specified and directed. 33 1 Each Job
34 34 M&L cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrinkable type joint, complete with and including jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 120 Sqmm, also with and including connecting single ferrules/thimbles etc after disconnecting of electric supply including removing burnt out jointing kit etc, complete all as specified and directed. 34 1 Each Job
35 35 Material and labour for painting of HT 4 pole structure consisting of steel tubular poles, bracing, cross arms, channels,clamps, supports, nuts, bolts with two coats of Silver paint over a coat of red oxide primer after preparing the existing external surfaces and marking of nomenclature of pole with black paint and including making alternate strips each of 30 cm height with black and red synthetic enamel paint upto 1.20 mtr height from top of PCC copping, complete all as specified and directed. 35 2 Each Job
36 36 Material & labour for painting of HT two pole structure consisting of steel tubuler poles and connected steel sections such as bracing, cross arms , channels, supports, clamps , nuts , bolts of any type with two coat of aluminium paint over a coat of red oxide primer after preparing the old painted external surfaces and marking of nomenclature of pole with black paint and including making alternate strips each 30 cm with black and red synthetic enamel paint upto 1.20 mtr height from ground level complete all as specified and directed . 36 2 Each Job
37 37 Material & labour for painting of LT PCC pole of any type with two coat of acrylic emulsion paint over a coats of primer including making alternate strips each of 30 cm height with black and yellow synthetic enamel paint upto 1.20 mtr height from top of PCC copping, complete all as specified and directed. 37 20 Each Job
38 38 Material & labour for GI tubes, "light grade", 80mm bore with and including all fittings laid in trenches/road crossing/floors etc for cable protection, complete all as specified and directed.\nNote: Excavation and earth work shall be measured and paid for separately. 38 6 RM
39 39 Material & labour for GI tubes, "light grade", 50 mm bore with and including all fittings laid in trenches/road crossing/floors etc for cable protection, complete all as specified and directed.\nNote: Excavation and earth work shall be measured and paid for separately. 39 6 RM
40 40 Supply and fix in repair MCCB, 315 Amps, 35/36 KA, 4 pole, 415 volts, 50Hz and making cable connections and testing complete all as specified and directed. \n 40 1 Each Job
41 41 Supply and fix in repair MCCB 200 Amps, 25 KA, 4 pole, 415 volts, 50Hz and making cable connections and testing, complete all as specified and directed.\n 41 2 Each Job
42 42 Supply and fix in repair MCCB 100 Amps, 16 KA, 4 pole, 415 volts, 50Hz and making cable connections and testing, complete all as specified and directed. \n 42 2 Each Job
43 43 Supply and fix in repair MCCB 63 Amps, 16 KA, 4 pole, 415 volts, 50Hz and making cable connections and testing, complete all as specified and directed.\n 43 3 Each Job
44 44 Supply and fix in repair MCB 63 Amps, 16 KA, 4 pole, 415 volts, 50Hz and making cable connections and testing, complete all as specified and directed.\nMake for I No 40 to 44 :-Schneider/Standard/Legrand/L&T/Havellls (ISI marked) 44 2 Each Job
45 45 Removing the existing unserviceable meters of any type from existing LT Panel/Panel boards/feeder pillar boxes after disconnecting of electric connection and supply and fix digital type voltmeter 0 to 500 volts with and including selecter switch and making cable connections and testing complete all as specified and directed. 45 2 Each Job
46 46 Removing the existing unserviceable meters of any type from existing LT Panel / panel boards/feeder pillar boxes after disconnecting of electric connection and supply and fix digital type ammeter 0 to200 Amps with and including selecter switch and appropriate CT's and making cable connections and testing complete all as specified and directed. 46 2 Each Job
47 47 Taking out the LT ACB 630 Amps to 800 Amps capacity of any make and model from the existing position after disconnecting of electric supply , carrying out genaral servicing , overhauling, cleaning the parts thoroughly with cleaning agents and applying lubricant oil and grease for the moving contacts after removing the carbon deposits and cheking the trip device system and circuit control wiring and reparing of push button system complete and reconnecting back and testing complete all as specified and directed 47 1 Each Job
48 48 M & L for complete servicing and maintenance of HT breaker 630 Amps to 800 Amps panel including cheking of contacts, lubrication of mechanism, cleaning, tightening , Insulation Resistance Test for existing rated H.T beaker . Tightening and replace of all control wiring panel,repair and replace to manual/electrical closing/trippping. Opening of panel back covers, removing and replace of Bus bar, revamping of CT ,removing of PT, removing of Ct's, cleaning of all bus bar and replace all sleeves and all space heaters , CT chamber and heating up chamber to remove moisture pressure test with pressure test kit.complete testing of breaker ,checking mechanism of fixed and moving contacts and removing carbon deposits and overhauling and replace of spring charged mechanism and operation of indicators are correctly showing the ON/OFF and spring charged / discharged system, cleaning the surfaces of insulators, and replace all insulators of 11 KV bus bar , fasten the bolts fixed in interrupting units, mechanism linkages etc. lubricating and greasing the mechanism of moving parts and reparing and replace of trip push button assembly including testing and calibration of protection relays and installation of battery set for continious DC supply to relay and also replace of MICOM P111- O/C & E/F relay and reconnecting back the VCB and testing complete all as specified and directed.\n Note:- The quoted rates shall also be deemed to include for submission of test reports for testing as specified above 48 2 Each Job
49 49 Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation, Cable, Pipe etc and 10 Sqm on plan and not exc 1.5 metre in depth for pits, independent holes, pole foundation etc, including getting out in any type of soil, complete all as specified and directed. 49 110 Cum
50 50 Returning, filling in with approved earth including spreading, leveling, watering and well ramming in layers n exc 25 cm thick each layer , complete all as specified and directed. 50 76.58 Cum
51 51 Removing excavated material/soil to a distance not exc 50m and depositing where directed at a level not exceeding 1.5metre above the starting point , complete all as specified and directed. 51 33.42 Cum
52 52 Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches upto 23 cm and punning to 18 cm complete all as specified and directed. Note: Punned thickess i.e 18 cm shall be measured for payment purpose. 52 40.5 Cum
53 53 Supply and laying unreinforced precast factory made concrete cable cover, class LV, Type -I, flat, size 250mm x 150mm x 40mm,ISI marked complete all as specified and directed. 53 2800 Each
54 54 Supply and laying unreinforced precast factory made concrete cable cover, class HV, Type -I, flat, size 300 mm x 180mm x 40mm,ISI marked complete all as specified and directed. 54 195 Each
55 55 M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregates as in foundation of pole, struts etc, complete all as specified directed. 55 2 Cum
56 56 Supply and fix LED street light fitting 36 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish.prismatic polycarbonate cover with individual LED lenses with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and removing old unserviceable item complete all as specified and directed. \nMake:- HAVELLS /BAJAJ/PHILLIPS /SHAKTI/HALONIX/CROMPTON 56 5 Each
57 57 Supply and fix LED street light fitting 45 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish.prismatic polycarbonate cover with individual LED lenses with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and removing old unserviceable item complete all as specified and directed. \nMake:- HAVELLS /BAJAJ/PHILLIPS /SHAKTI/HALONIX/CROMPTON 57 10 Each
58 58 Supply and fix LED flood light luminaire 150 watts with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection comple with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc. at any height providing clamps, nuts, bolts and washers etc. including removing old unserviceable items complete all as specified and as directed by Engineer-in-Charge.\nMake:- HAVELLS /BAJAJ/PHILLIPS /SHAKTI/HALONIX/CROMPTON 58 6 Each
59 59 Supply and fix LED flood light luminaire 180 watts with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection comple with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc. at any height providing clamps, nuts, bolts and washers etc. including removing old unserviceable items complete all as specified and as directed by Engineer-in-Charge.\nMake:- HAVELLS /BAJAJ/PHILLIPS /SHAKTI/HALONIX/CROMPTON 59 5 Each
60 60 Supply and fix analogue time switch(Daily time switch) suitable for outdoor ,power contactor 63 Amps ML-2 type,3Phase,415 volts and MCB TPN 63 Amps,10 KA 'C' series , including bus bar of suitable capacity with arrangement of auto/mannual control switch duly prewired and all accessories same shall be enclosed in and including sheet metal enclosure of 3.2 mm thick CRCA sheet of adequate size with powder coated, fixing arrangements on floor including powder coated painting and mounted on 50x50x6mm MS angle iron frame duly painting and including removing old unserviceable item complete all as specified and directed. Make of timer :- Legrand/L&T/ HPL/GE \nMake of Contactor:- Siemens/L&T/ABB/Schneider/GE \nMake of MCB:- Legrand/L&T/Siemens/HPL/Havells 60 1 Each
61 61 Supply and fix FRP looping box of size 250x200x105mm with connector and comprising of MCB SP 6 Amps, ISI marked,240V complete with and including providing GI clamps,nuts bolts etc suitable for fixing on PCC pole/ wall etc and including removing old unserviceable item complete all as specified and directed. Make:- National/Sintex 61 10 Each
62 62 Supply and fix copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade, 3 core ;1.5 sqmm and including connection and testing inlcuding removing old un\nserviceable item complete all as specified and directed. Make:-Havell/Finolex/Plaza/Polycab 62 53 RM
63 63 Supply and fix rigid non-metallic PVC conduit 25 mm dia medium grade including conduit accessories for encasing the cable from looping box to street light fittings on PCC poles/on wall surfaces as per site requirement with neccessary base saddles all as specified and directed. Make:- Finolex/Prince/Supreme/Precision/Dutron/Tirupati 63 30 RM
64 64 Supply and fix pin type insulator porcelain, vitreous white, brown or green including one galvanised mild steel spindle, two washers and one nut of size 150 mm height &150 mm dia of working pressure 11 KV grade including removing of old unserviceable item complete all specified and directed 64 6 Each Job
65 65 Supply and fixing cable tray 150mm wide x 50mm deep, hot dip galvanised with standard slot pattern manufactured from CRCA sheet 2.00 mm thick duly pre-treated with hot dip galvanising in seven tank process, perforated type including provision of fixing arrangement, nuts & bolts etc for proper securing to walls/beams or suspended from ceiling, complete all as specified and directed 65 20 RM
66 66 Supply and fixing cable tray 200mm wide x 25mm deep, hot dip galvanised with standard slot pattern manufactured from CRCA sheet 2.00 mm thick duly pre-treated with hot dip galvanising in seven tank process, perforated type including provision of fixing arrangement, nuts & bolts etc for proper securing to walls/beams or suspended from ceiling, complete all as specified and directed 66 20 RM
67 67 Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-290 Gde E-165 including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of red oxide primer coat and two coat of silver paint all as specified and directed. 67 0.89 Per Qtl
68 68 M&L for prepartion scrubing removing of old paint and painting with electrically operated spray machine surfaces of LT Panel/feeder piller box of any type/make including removing of old paint with scrubing etc and applying two coats of synthetic emanel paint of shade as per existing, complete all as specified and directed. 68 3 Each Job
69 69 M& L for cutting of branches at any height of trees surrounding to the street light pole which obstruct the light to reach the ground and removing from the site to said area whrere specified and directed .(cutting tools, ladders and connected items deemed into the quoted rates) 69 20 Each job
70 70 Material and labour in repairs for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 25 X 4 mm from earth electrode to test point or up-to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Part-I provision of G I Pipe 40mm bore eight grade for protection of GI strip and GI watering pipe of 20 mm bore medium grade,GI funnel with wire mesh,including char-coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed. 70 4 Each Set
71 71 Repairs to boom barrier electrically operated type,230 volts of make Godrej and opening of boom barrier assembly examine thoroughly and carry out servicing ,overhauling,grasing and replacement of spare parts/accessories such as control board,slow shaft, lever arm, release lever lock cylinder,boom bar including replacing of suitable nuts,bolts and washers etc and certain minor items and testing for its efficient functioning complete all as specified and directed. \n Note:-(i) Spare parts/accessories will be measured and paid separately under relevent item of schedule as supply only. \n (ii) Labour element for fixing of supply only items and removing of old unserviceable item are deemed to be included in quoted rate. \n (iii) The work shall be carry out through OEM only. 71 6 Job
72 72 Supply only control board suitable for boom barrier of existing make Godrej 72 2 Each
73 73 Supply only lever arm suitable for boom barrier of existing make Godrej 73 2 Each
74 74 Supply only release lever lock cylinder suitable for boom barrier of existing make Godrej 74 2 Each
75 75 Supply only boom bar for boom barrier of existing make Godrej 75 1 Each
76 76 Repairs to "Road Blocker" electro-hydrualic driven type including checking of blocking segment and under ground housing and carry out lubrication of bearings,joint heads of hydraulic cylinders, check all functional components,connections etc and electrical control unit installed in the separate steel drive unit housing, hose connections to the drive unit in the under ground housing.Cleanining the under ground housing properly without damaging to other parts.Checking up the hydraulic unit with motor 5.5 KW,415 volts ,50Hz, pump: 22.0 l/min, control valve and tank, hand pump including carryout works such as loosen the screw of the oil filler socket at the filter and remove contamination, adjust the valves, control assembly and remove oil residue, titaning of all hydraulic connection hoses, checking up revers flow filter, adjust the operating pressure.Checking up the electrical control unit, PLC based control SE 140 unit ,loop detector,transformer,contactor electrical and electronic circuit system and rectify the defects by replacing certain minor spares such as fuses,terminal connectors,copper conductor control cable, gaskets, spring washers,nuts,bolts and washers of any type and replacement of hydraulic oil and spare parts/accessories such as throttle valve, push button(Open-Close) ,proximity switch, pressure gauge, electronic 24 Volts power supply charger, power contractor 3 pole, suitable for 5.5 kw motor, 415 volts,50Hz,transformer, power supply box etc and including servicing, greasing,overhauling of blocking segment,under housing and hydraulic unit assembly with motor pump and control valves and testing the complete road blocker working system as per as per manufacturer specifications complete all as specified and directed.design parameters and specification:-\n(i) Blocking width:4000 mm size. \n (ii)Raised height :1100 mm (min) \n(iii) Crash rating : 6.8 tonnes vechicle weight (min) with Nil penetration PAS 68:2010 or ASTM-M50(DOS-K-12)certified \n (iv) Static equivalent load (impact load):926KN (min) \n (v)Raising time: 1.5 second(max) \n(vi) Lowering time :3.0 second (max) \n (vii)Driving unit: Electro hydrualic \n (viii) Operating temparature : (-) 5 to 50 degree C \n(ix) Normal position: NC (normally closed) / lowered \n(x)Axle weight: withstand to 100 KN (min) \n(xi) Features : Manual operation during power failure by integrated hydraulic hand pump. (xii) Operation on power supply:- 3 Phase,415V,50Hz. (b) Spare parts/accessories/hydraulic oil will be measured and paid separately under relevent item of schedule as 'supply only'.\n(i) Labour element for fixing of supply only items and removing of old unserviceable items are deemed to be included in quoted rate\n(ii) The work shall be carried out through OEM only.\n\n\n \n 76 2 Each Job
77 77 Supply only Solenoid switch 78 2 Each
78 78 Supply only Relay contactor 79 2 Each
79 79 Supply only Hydrualic jack bearing \n\n\n Sch of credit Rs 41426.00 80 2 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail