Construction Of Proposed New Bldg Bplusgplus9 Opposite To Centenary Bldg Within The Campus Of Nrsmch Kolkata Electrical Works Dismantling And Reorientation Of Of Existing Cable Feeder Pillar Box Light Pole Lt Panel And Allied Works, NRSMCH-West Bengal

Public Works Department-PWD has published Construction Of Proposed New Bldg Bplusgplus9 Opposite To Centenary Bldg Within The Campus Of Nrsmch Kolkata Electrical Works Dismantling And Reorientation Of Of Existing Cable Feeder Pillar Box Light Pole Lt Panel And Allied Works. Submission Date for this Tender is 01-06-2021. Electrical Maintenance Tenders in NRSMCH West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

27901972
Construction Of Proposed New Bldg Bplusgplus9 Opposite To Centenary Bldg Within The Campus Of Nrsmch Kolkata Electrical Works Dismantling And Reorientation Of Of Existing Cable Feeder Pillar Box Light Pole Lt Panel And Allied Works
Open Tender
Indian
West Bengal
NRSMCH
01-06-2021

Tender Details

Construction Of Proposed New Bldg Bplusgplus9 Opposite To Centenary Bldg Within The Campus Of Nrsmch Kolkata Electrical Works Dismantling And Reorientation Of Of Existing Cable Feeder Pillar Box Light Pole Lt Panel And Allied Works

Key Value

Document Fees
Refer document
EMD
INR 72339.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of proposed new building (B+G+9) opposite to Centenary Building within the campus of NRS Medical College & Hospital, Kolkata-Electrical Works----Dismantling and reorientation of Existing cable Feeder pillar Box, Light pole, LT panel and Allied works.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Dismantling of old Feeder Piller box after disconnecting of all incoming & outgoing cables and connected SFUs and others accessories also to be shifting to store room and also mending good damages to original finish as directed by EIC. 1 Job
2 2 Dismantling of old LT panel box after disconnecting of all incoming & outgoing cables and connected SFUs and others accessories also to be shifting to store room and also mending good damages to original finish as directed by EIC. 1 Job
3 3 SITC OF CUBICLE TYPE LT PANEL\nSITC of LT,Cubicle Type,Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz,as per size, design & drawing to be approved by EIC.The panel board will be fabricated by CPRI approved panel maker as per detail specification below. 1 item
4 3.01 The general construction of the pannel will conform to IS 8623:93 as ammended uptodate. The Degree of IP protection for the enclosure will be IP-42.It will have multi tier arrangement, having necessary cable alley at both end, with rigid and self supporting structure fabricated with sufficient no. of channels & covered by 2mm thick CRCA sheet with base structure by 75x40x4mm channel.
5 3.02 All incoming, outgoing SFUs & Bus Coupler are to be housed in respective compartments with hinged and gasketted doors at the front. All the doors should have pannel lock arrangements in such a fashion that it cannot be unlocked unless the respective feeder remains OFF. The rear of the pannel should have gasketted wire net guard for ventillation and arrangement shall be made for easy access to each compatment by providing rear doors with locking system.
6 3.03 The pannel is to be properly gasketted to prevent the dust and vermin. All vertical and horizontal bus bar chamnbers are to be properly arranged and all electrical switches, busbars are to be fixed by MS nut-bolts on suitable hylam board / non - hygroscopic insulators of adequate size and dimensions. The outgoing feeder connections from respective switches are to be made at the rear side of the pannel by means of bus-bar/multicore copper cables, to be terminated on bolted type terminals for cable connections or bush insulators for bus connection
7 3.04 It will be powder coated after seven tank pretreatment process.2 Nos copper strip of size as per IS shall be fixed all around the panel and will be connected to 2 nos copper earth bus bar connected to incoming earth conductor.All tests should be made for the complete panel.The following 415 / 230 Volt Open Execution Type switches with fuses & accessories will be fixed in the panel. [ ACB/MCCB/SFU/CO etc. will be as per given Approved Make List. All the other accessories will be as per given Approved Make List and as per manufacurers standard ].
8 3.05 BUSBAR
9 3.06 600A, 4 x (2x 40x5) mm Busbar made of 99.99% electrolytic tinned copper flats
10 3.07 INCOMER
11 3.08 Supplying and fixing 415V, 400A, TPN on load front operated Changeover switch open execution type in SS cubical with nuts bolts etc.-1 no.
12 3.09 OUTGOING
13 3.1 (i)415V, 160A, 4 pole 36 kA , MCCB with Thermal magnetic release having both side spreader link, extended rotary handle etc. - 4 Nos
14 3.11 (i)415V, 125A, 4 pole 36 kA , MCCB with Thermal magnetic release having both side spreader link, extended rotary handle etc. - 3 Nos
15 3.12 (i)415V, 63A, 4 pole 36 kA , MCCB with Thermal magnetic release with extended rotary handle etc. - 2 Nos
16 3.13 METERING & ACCESSORIES
17 3.14 Multi function meter Accuracy Class 1 having RS485 port for integration with 3rd party SCADA system Industry standard Modbus RTU protocol Legrand PMX 700 or equivalent product of approved make list having similar specification in all respect. - 1 No.
18 3.15 Current transformers 400/5, VA - 8, - 3 Nos
19 3.16 R-Y-B LED Indicator Lamp - 3 nos
20 3.17 SPMCB 0-6A - 3Nos
21 4 FEEDER PILLAR BOX \nDesign, Manufacture, testing, supply and commissioning of Double door outdoor type Distribution Feeder Pillar box conforming to Indian Standard IS : 5039-1969 with latest amendments,suitable for use on 3 phase 4 wire, 400/440 Volts 50 Cycles A.C. Supply and shall be suitable for short circuit fault of 31 MVA at 415 Volts, fabricated as per size, design & drawing to be approved by EIC. The Enclosure shall provide Degree of protection IP -54 in accordance with IS : 2147 -1962 with its latest ammendmentThe feeder pillar box will be fabricated by CPRI approved fabricator as per detail specification below. 1 Item
22 4.01 The Enclosure shall provide Degree of protection IP -54 in accordance with IS : 2147 -1962 with its latest ammendment.The body will be fabricated with 3mm thick MS plate, MS angle ( 50X50X6) & MS Flat ( 50X6 ). The Base Plate will be made by 5 mm thick MS Plate. The top of the box will be fitted with a sloping canopy made out of 3 mm thick sheet steel. It will have a set of water proof double hinged door at the front and back with suitable locking arrangement ( Godrej Type ) and provision for manual locking arrangement.
23 4.02 Adequate ventilation by means of louvers with wire mesh shall be provided on both sides and at the top and bottom of both sides of LT pillars.The inside will be painted by 1 coat of Redled / zinc chromate and the outside will be painted by 2 coats of synthetic enamel paint over 1 coat of Redled / zinc chromate. A hylam sheet of 10mm thick of suitable size will be fitted for holding the switches and accessories ,that will be supplied and fixed as specified below by making necessary interconnection by required sizes CU wires & Epoxy paintings as per direction of EIC. The following 415 / 230 Volt Cubicle Type switches with fuses & accessories will be fixed in the panel.
24 4.03 It will be installed on a suitable size brick pillar platform with first class brick foundation 60 cm above ground level & 30 cm below ground i/c plastering as per direction of Engineer-in-charge.The following 415 / 230 Volt Cubicle Type switches with fuses & accessories will be fixed in the panel.
25 4.04 [ ACB/MCCB/SFU/CO etc. will be as per given Approved Make List. All the other accessories will be as per given Approved Make List and as per manufacurers standard ]
26 4.05 BUSBAR
27 4.06 1000A, 4 x (2x 80x5) mm Busbar made of 99.99% electrolytic tinned copper flats
28 4.07 INCOMER
29 4.08 Supplying and fixing 415V, 800A, TPN on load front operated Changeover switch open execution type in SS cubical with nuts bolts etc.-1 no.
30 4.09 OUTGOING
31 4.1 (i)415V, 400A, 4 pole 50 kA , MCCB with microprocessor release having both side spreader link, extended rotary handle etc. - 1 Nos
32 4.11 (i)415V, 200A, 4 pole 50 kA , MCCB with microprocessor release having both side spreader link, extended rotary handle etc. - 5 Nos
33 4.12 (i)415V, 100A, 4 pole 50 kA , MCCB with microprocessor release with extended rotary handle etc. - 2 Nos
34 4.13 METERING & ACCESSORIES
35 4.14 Multi function meter Accuracy Class 1 having RS485 port for integration with 3rd party SCADA system Industry standard Modbus RTU protocol Legrand PMX 700 or equivalent product of approved make list having similar specification in all respect. - 1 No.
36 4.15 Current transformers 800/5, VA - 10, - 3 Nos
37 4.16 R-Y-B LED Indicator Lamp - 3 nos
38 4.17 SPMCB 0-6A - 3Nos
39 4.18 415V. Danger Board ( 8"x12") - 01 No
40 5 Shifting & Reinstallation of existing old outdoor type feeder Piller Box of size (H 6' X L 5' X B 3') after the cutting of 25 sq. feet RCC foundation and to be constructed of Brick foundation of a height 12'' from ground level and inside the ground of 24''(inch) with 1st class bricks in lime and surki mortar (1:3) ( 1 lime putty/paste: 3 surki) lime to be slaked at site and the mortar to be prepared with such lime putty and first class surki made from kiln burnt bricks having its fineness modulus between 2 and 2.5 and which passes through B.S. sieve No 8 with correspondes to I.S sieve No 200 with considerable grinding and pugging it complete.Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed upto 150mm thickness.Plaster (to wall, floor, ceiling etc.) with sand and cement mortar with 1:3 cement mortar 20 mm thick plaster of 20 Sq.feet. 1 job
41 6 Supply and fixing medium gauge GI pipe (ISI-Medium) protection with necessary fittings and jointing meterials as required(for protection of 120 to 300Sqmm cable)
42 6.01 a) 125 mm dia 40 mtr
43 6.02 b) 150 mm dia 40 mtr
44 7 Supply and fixing medium gauge Humepipe protection with necessary fittings and jointing meterials as required(for protection of 120 to 300Sqmm cable)
45 7.01 a) 100 mm 30 mtr
46 7.02 b) 200 mm 30 mtr
47 7.03 c) 300 mm 30 mtr
48 8 Withdrawing the following sizes of old PVC / XLPE Al cable from underground masonary trench by earth excavation /withdrawal of checker plate very carefully and after withdrawal and ramming the excavated soil to label the ground/ repossioning the checker plates at its intial condition/ position inc. relaying the withdrawn cable through existing cover masonery trench incl. taking out RC cover setting them order, mending goiod the damages and filling the trench with fine dry sand incl. supplying sand as per direction of EIC.
49 8.01 a) 4Core 95 sqmm/120 sqmm/150sqmm/ 240 sqmm 734 mtr
50 9 S&F 415V 4 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, as per direction of the EIC.\nIncoming - 415V 63A FPMCB isolator(1no)\nOutgoing - 10KA 6-32A SPMCB-(12nos) 1 set
51 10 S&F 415V 2+12 way double door SPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, as per direction of the EIC.\nIncoming - 220V 40A DPMCB isolator(1no)\nOutgoing - 10KA 6-32A SPMCB-(12nos) 1 set
52 11 Supply & Delivery of Hot Dip Galvanised (as per IS:2629 / IS 2633 / IS 4759 and with its latest amendment ) Octagonal Pole made of HT steel ( sheet thickness -3mm ) conforming to grade S355 of BSEN 10025 alongwith welded base plate of required size conforming to IS: 226 / 2062 with integrated Control box with required sizes studs for termination of 2 core 10 /4 Core 16 sq mm Al (Armoured ) cable incld S&F 1 No 6 Amp SP MCB ( C-Series ) for each out going circuit to the fittings with proper pad locking arrangement for the following pole -- \n 9 Mtr Long [ Top Dia ( A / F ) - 70 mm, Bottom Dia ( A / F ) -155 mm ] Base Plate Size : 260 mm x 260mm x 16 mm.. 5 sets
53 12 Errection of the following Octagonal pole by designing and Casting RCC ( M 20 ) foundation of suitable size as specified below considering the safe soil bearing capacity at site as T/sq m, including excavation of earth, providing, cutting, bending and placing in position reinforcement as per drawing and providing pipe for cable entry and exit as required and providing and fixing of 4 Nos foundation bolts ( J Type ) as specified below and as per drawing on ground surface including back filling and cleaning extra earth.\n9 Mtr Long [ Founation size - 600 mm X 600 mm X 1500 mm, J Bolt Size - Dia 24mm Length 750mm ] 5 nos
54 13 Supply and laying of following multistrand Aluminium armoured cable through U.G. Trench 460 mm wideX760 mm average depth, with brick protection on the top of the cable with 8 (eight) nos brick per meter, incl. fitting the space between the brick & cable and also the trench with shifted soil, leaving up and restoring surface duly rammed . Road cutting will not be allowed. If required, U/G boaring can be allowed for laying cable. i) XLPE insulated armoured Al. 4 core 16 sqmm cable. 100 mtr
55 14 Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire in 20 mm size PVC rigid conduit 'FR' incl. necy. fittings as required, as directed by EIC.
56 14.01 a) 2x6sqmm + 1x4sqmm [TPNDB to SPNDB] 50 mtr
57 15 Finishing the end of above PVC insulated & unsheathed copper wire, as directed by EIC.
58 15.01 a) 2x6sqmm + 1x4sqmm [TPNDB to SPNDB] 80 set
59 16 Supply & Delivery of 1.1 KV grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984 / 3975:1970 /8130:1984/ 3961:1967/ 10418:1982 / 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith.
60 16.01 a) 2 core 10 sqmm 60 mtr
61 16.02 b) 4 core 16 sqmm 180 mtr
62 16.03 c) 4 core 50 sqmm 190 mtr
63 16.04 d) 4 core 70 sqmm 210 mtr
64 16.05 e) 4 core 95 sqmm 210 mtr
65 16.06 f) 4 cor 150 sqmm 250 mtr
66 16.07 g) 4 core 240 sqmm 320 mtr
67 16.08 h) 4 core 300 sqmm 280 mtr
68 17 Laying on Wall / surface with Saddles / clamps.\nLaying of following cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
69 17.01 (i) Upto 3/4 core 25 sqmm 200 mtr
70 17.02 (ii) From 3/3½/4 core 35 sqmm to 50 sqmm 150 mtr
71 17.03 (iii) Cable above 3/3½/4 core 50 sqmm and upto 3/3½/4 core 95 sqmm 350 mtr
72 17.04 (iv) Cable above 3/3½/4 core 95 sqmm and upto 3/3½/4 core 150 sqmm 200 mtr
73 17.05 (v) Cable above 3/3½/4 core 150 sqmm 500 mtr
74 18 Laying of one No. cable of following sizes cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
75 18.01 (i) Upto 3/4 core 35 sqmm 100 mtr
76 18.02 (ii) From 3/3½/4 core 50 sqmm to 185 sqmm 100 mtr
77 18.03 (iii) Cable above 3/3½/4 core 185 sqmm 100 mtr
78 19 Laying of two cables in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
79 19.01 (i) Upto 3/4 core 35 sqmm 10 mtr
80 19.02 (ii) From 3/3½/4 core 50 sqmm to 185 sqmm 10 mtr
81 19.03 (iii) Cable above 3/3½/4 core 185 sqmm 10 mtr
82 20 Laying of one cablethrough existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand 100 mtr
83 21 Laying of 3/3-1/2 /4 core Armour Al Cable on existing Cable tray with necessary holding, binding arrangement, support etc if required as per direction of the EIC. 100 mtr
84 22 S&F compression type cable gland complete with brass gland, bursh ring & rubber ring for dust & moisture proof entry of 1.1 KV 4 core following size XLPE/A cable, incl. finishing the end with sockets, by crimping method ,as directed by EIC.
85 22.01 a) 2 core 10 sqmm 22 set
86 22.02 b) 4 core 16 sqmm 60 set
87 22.03 c) 4 core 50 sqmm 20 set
88 22.04 d) 4 core 70 sqmm 10 set
89 22.05 e) 4 core 95 sqmm 10 set
90 22.06 f) 4 cor 150 sqmm 6 set
91 22.07 g) 4 core 240 sqmm 6 set
92 22.08 h) 4 core 300 sqmm 8 set
93 23 Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC)
94 23.01 a) 3½ / 4 core 120-150 sqmm cable 2 job
95 23.02 b) 3½ / 4 core 95 sqmm cable 2 job
96 24 S/l of 3x1.5 sqmm Cu wire from Loop box to Luminaire through pole incl. Soldering/socketting the both end as per direction of EIC.( Finolex) 150 mtr
97 25 Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 55 mtr
98 26 Supply of uniflood is an integal flood light with driver inside a pdc housing is an IP66 LED lighting luminaire. [Make-Philips, Cat no-BVP122 LED 124 CW HE AK55 FG XTFCL S4 or equivalent make and model of Cromption /Wipro having similar specification in all respect] 3 sets
99 27 Supply of Tempo LED is a flood lighting luminaire with high power LED and unique flood optics to uniform distribution with driver an IP66 ratting.[Make-Philips,Cat no-BVP410 LED 245 CW HE FG S4 XTFCL or equivalent make and model of Cromption /Wipro having similar specification in all respect] 3 sets
100 28 Fixing only street light/Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure, as to GS. 30 sets
101 29 Dismantling of 12 mtr long steel tubular pole including arm bracket from roadside after disconnecting all connections and breaking RCC muffing with base (600mm x 600mm x 1500mm depth) for pole end under the ground then filling the hole properly and ramming by co’s own tools and tackle as to G.S.. 17 nos
102 30 Shifting of 12 mtr long steel pole including arm bracket from work place to section store as per direction of EIC. 12 nos
103 31 Erection of 12 mtr long steel tubular pole with sole plate & cap etc. in CC (4:2:1) base block below sole plate with hard jhama metal incl. pipe pole to be surrounded with 600x600mm jhama concrete mortar having 6:3:1 ratio up to G.L incl. 3mm thick neat cemented finishing & providing G.I earth bolt after making drilled hole etc. on pole. 12 nos
104 32 Foundation providing C.C (6:3:1) base block (around the pole) dimension (60x 60 x 76mm) above ground level ,neat cemented finish (3mm thick)at the base pole incl drilled hole in pole suitable for polythene pipe entry for street light wiring without loop box. 12 nos
105 33 S & F 40mm dia 1.5mtr arm bracket incl. 2 nos MS clamp fixed with suitable size fastener incl. painting on wall. 17 nos
106 34 Inter connection with 3x1.5 sqmm PVC insulated & unsheathed Copper conductor through arm bracket from loop box to HPSV/LED fittings.(12 nos.) 250 mtr
107 35 Fixing of outdoor type street light fitting on pole including S&F cap type 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with necessary arrangement etc. and providing wiring with 2x1/1.50 PVC insulated and unsheathed copper wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections & painting, as directed by EIC. 6 nos
108 36 Painting of Steel Tubular Pole up to 9 mtr of lengths and no. of coats of paint, as given with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint
109 36.01 (i) 1st coat of aluminium paint over 1 coat of RO priming per pole \n(ii) 2nd coat of aluminium paint over 1st coat 17 nos
110 37 Supply&fixing of 250V Timer DB (equivalent of 8 way SPN DB in size) with steel sheet enclosure double door, phosphatised powder coated , neutral bar, Din Rail with IP-43 protection comprises with 1 no. 20A/25A DP MCB ('C' Curve, 10 kA,), 1 no. 24 hours programmable Time Switch with minimum switching time of 15 minutes and 1 no. 18A/25A contactor, single phase screw type motor starter(compact-25A-min.) complete with internal wiring by suitable size of copper wire including 1 no. Auto Manual bypass MCB Changeover Switch and provision for earthing attachment including LED indication light for running condition with locking arrangement. ( For 1.5 / 2.0 TR) 2 set
111 38 Supply&fixing of 415V Timer DB (equivalent of 8 way SPN DB in size) with steel sheet enclosure double door, phosphatised powder coated , neutral bar, Din Rail with IP-43 protection comprises with 1 no. 25A TPN MCB ('C' Curve, 10 kA,), 1 no. 24 hours programmable Time Switch with minimum switching time of 15 minutes and 1 no. 25A contactor, complete with internal wiring by suitable size of copper wire including 1 no. Auto Manual bypass troggle Switch and provision for earthing attachment including LED indication light for running condition with locking arrangement. 1 set
112 39 cost of Hiring of 415V, 3phase,50HZ,250 KVA capacity vehicle mounted silent DG set of reputed make in good operating condition and not more than five (5) years old with 150mtr of good quality cable capable of carrying full load current along with driver, DG operator, Helper and others tools & takoles as per directed by EIC. 10 day
113 40 Cost of fuel (Based on actual consumption in Ltr) at the prevailing market price. 800 Ltr
114 41 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1x4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S&F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level, incl. excavation of approx 1 m3 of soft soil for installation of Earth Electrode and filling & ramming, by ISI-Medium GI Pipe for soft soil, as directed by EIC. 17 set
115 42 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc 20 mtr
116 43 Supply of 1.1KV grade,unarmoured 3core 4sqmm cu cable (Make: Gloster/Finolex). 150 Mtr
117 44 Cost of wall cutting by tools and appliances with cement,brick,morter finishing and plastering to meet up desire dimension incl mending goods damages and painting.All the air gapes should be fill up by cement brick,morter or other filler material as desired.All the cost of related and acessaries works are to be incorporated with these job as directed by EIC . 440 Cuft
118 45 List of Approved makes is attached in separate sheet
119 46 Rate should be quoted incl. of all taxes and cess.
120 47 Defect Liability period : 1 year
121 48 The Bidder must have valid Electrical Contractors License with Electrical Supervisor holding Supervisor competency on the parts 1, 2, 3, 4, 5, 7 (A) (B), 10,11,12 as per I.E. Rules or equivalent National Supervisors Certificate of competency. The bidder should have the acknowledgement of authentication from Directorate of Electricity, West Bengal in respect of the Supervisor attached with the firm. The contractor shall have scan copy of valid electrical contractor license and valid supervisor competency certificate with proper engagement/appointment letter incl. mentioning time validity