2Nd Retender Supply , Installation , Testing , And Commissioning Of Dg Set At Skbu , Purulia In The District Of Purulia---Electrical Installation Work For Installation Of Diesel Generator Sets, PURULIA-West Bengal

Public Works Department-PWD has published 2Nd Retender Supply , Installation , Testing , And Commissioning Of Dg Set At Skbu , Purulia In The District Of Purulia---Electrical Installation Work For Installation Of Diesel Generator Sets. Submission Date for this Tender is 31-05-2021. Electrical Maintenance Tenders in PURULIA West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

27901622
2Nd Retender Supply , Installation , Testing , And Commissioning Of Dg Set At Skbu , Purulia In The District Of Purulia---Electrical Installation Work For Installation Of Diesel Generator Sets
Open Tender
Indian
West Bengal
PURULIA
31-05-2021

Tender Details

2Nd Retender Supply , Installation , Testing , And Commissioning Of Dg Set At Skbu , Purulia In The District Of Purulia---Electrical Installation Work For Installation Of Diesel Generator Sets

Key Value

Document Fees
Refer document
EMD
INR 42658.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Supply ,Installation,Testing, and Commissioning of DG set at SKBU, Purulia in the District of Purulia--Electrical Installation work for Installation of Diesel Generator Sets
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply of 1.1 KV grade XLPE insulated armoured cable with aluminium conductor (Make-Havells/RR Kabel/Gloster/Ploycab) as per direction of EIC BI01010001010000000000000515BI0100001112
2 1.01 3 ½ Core 400 sqmm BI01010001010000000000000515BI0100001113 120 Mtr
3 1.02 3 ½ Core 150 sqmm BI01010001010000000000000515BI0100001114 400 Mtr
4 1.03 3 ½ Core 95 Sqmm BI01010001010000000000000515BI0100001115 200 Mtr
5 2 Laying of one No. cable above 35 sqmm and upto 185 sqmm in UG trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. BI01010001010000000000000515BI0100001116 560 RM
6 3 Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. BI01010001010000000000000515BI0100001117 100 RM
7 4 Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand. BI01010001010000000000000515BI0100001118 40 RM
8 5 Laying of one cable above 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand. 20 RM
9 6 S&F 80 mm dia. Medium gauge GI Pipe (ISI-Medium) protection with necy. fitting and jointing material as required. 60 RM
10 7 S&F 100 mm dia. Medium gauge GI Pipe (ISI-Medium) protection with necy. fitting and jointing material as required. 30 RM
11 8 Extar Labour charges for boring/cutting the Metal road for fixing 80 mm/100mm GI pipe 100 RM
12 9 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
13 9.01 3 ½ Core 400 sqmm 6 Set
14 9.02 3 ½ Core 150 Sqmm 10 Set
15 9.03 3 ½ Core Core 95 Sqmm 10 Set
16 10 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
17 10.01 3 ½ Core400 sqmm 6 Each
18 10.02 3 ½ Core 150 Sqmm 10 Each
19 10.03 3 ½ Core 95 Sqmm 10 Each
20 11 Construction of DG set Foundation size by 3 mtr x 2 mtr x 1mtr ( 1 ft above the ground level & 2 ft below the ground level ) ordinary cement concrete mix 1:1.5:3 with graded stone chips of 20 mm down pakur variety laying concrete base (1:3:6) using 40 mm down stone metal & single brick flat soiling of picked jhama brick incl. at shuttering work by 25 mm to 30 mm thick wooden plank also ,rein inforcement with 8 mm tor steel atleast 150 kg total, this rate are incl. all materials, labour charges & carrying etc. Inner filling should be done with soft soil and 75mm thick red thick sand layer on top suitable for 82.5 Kva DG set( as per direction of EIC) 1 Item
21 12 Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts.long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (1 nos 250 KVA DG earthing body-2 nos, Neutral-2 nos,) [ body-2,neutral-2][For 2 nos 125 KVA , 1 no 82.5KVA , 1 no 250 KVA . 16 Set
22 13 Excavation of soil for installation of Earth Electrode and filling & ramming.\n[For Morrum Soil] @1.75cubic mtr/earth. 28 Cu. Mtr
23 14 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.\n 16 Item
24 15 Treatment of soil by using salt & charcoal for pipe electrode (morrum soil). 16 Set
25 16 Extra for connecting the neutral of Transformer/Earth busbar to earth electrode including S & F Galvanized (Hot Dip) Steel strip 65 mm x 8 mm on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape. 90 Mtr
26 17 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required 50 Mtr
27 18 Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. 100 Mtr
28 19 Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 40 Mtr
29 20 S&F PVC heat shrink sleeve of 1 mm thick for covering the 50x6mm GI flat 100 Mtr
30 21 S&F Exhaust gas pipe of 100 mm dia exhaust pipe made up of 20 SWG GI sheet cut to required lengths provided with flenge on both side of each peice having thin copper gasket installed with necessary bends, supports and clamp, anti- vibration mounting, insulation of exhaust system with mineral wool/Rockwool, 50 mm thick wire mesh & aluminium cladding etc. as required as per specification incl S & F rain protection canopy. 20 Mtr
31 22 S&F Exhaust gas pipe of 150 mm dia exhaust pipe made up of 20 SWG GI sheet cut to required lengths provided with flenge on both side of each peice having thin copper gasket installed with necessary bends, supports and clamp, anti- vibration mounting, insulation of exhaust system with mineral wool/Rockwool, 50 mm thick wire mesh & aluminium cladding etc. as required as per specification incl S & F rain protection canopy.. 10 Mtr
32 23 Supply and drawing 1.1KV 1x 35 sq. mm single core stranded ‘FR’ PVC insulated copper wire in PVC rigid conduit incl. necy. fitting as required embedding in wall /floor from neutral earth bus to generator neutral incl. both side socketing and necy. Connection [Polycab/Gloster/RR Kabel] 30 Mtr
33 24 Supply and drawing 1.1KV 1x 95 sq. mm single core stranded ‘FR’ PVC insulated copper wire in PVC rigid conduit incl. necy. fitting as required embedding in wall /floor from neutral earth bus to generator neutral incl. both side socketing and necy. connection. [Polycab/Gloster/RR Kabel] 20 Mtr
34 25 Supply and laying 14 core x 2.5 sq. mm PVC insulated armoured cable with copper conductor embedded in floor with necy connection. [Polycab/Gloster/RR Kabel] 50 Mtr
35 26 Supply and pouring High speed Diesel oil for starting and commissioning of DG set 300 Ltr
36 27 Supply and pouring Mobile oil (CH415W40) 20 Ltr
37 28 Supply and delivery of 200 ltrs capacity barrel made of heavy gauge MS sheet with High speed Diesel oil 1 Each
38 29 Supply and delivery of best quality oil hand pump with 25 mm dia PVC flexible pipe of 6 mtr length. [Make- JAIN TECH, 3.5mtr head, capacity-3ltr. M. S. Body] 2 each
39 30 Supply & installation of CPRI approved Cubical Type Compartmentalized floor mounted LT panel board of suitable size and shape for extension of existing LT panel board and made of 2mm thick CRCA sheet, angle/ flat iron for structural frame work & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint having copper Bus-bar and following equipment & accessories. Protection required of panel is IP-54.
40 30.01 Bus-bar :a) 415V 2000A Horizontal Bus-bar chamber to Vertical Busbar Chamber of hinged type door of electrolyte tinned copper bar with EPR support for main power distribution supply power to individual section from Bus-bar with suitable size electrolytic tinned copper bar all joint must be of bolted type construction. Proper colour code to be provided by PVC heat shrink sleeves.
41 30.02 Outgoing:\na) 400A 415VTPN switch disconnector fuse unit (L&T make cat no.SK95481 / Eq. Siemens/ Schneider) with 3 nos. of din type HRC fuses—3 nos. Necy. electrolytic tinned copper bars of Adequate size on suitable insulation must be provided for outgoing cable connection.
42 30.03 Constructional Details:\nThe panel to be made by 2mm thick CRCA sheet. The cable gland packing should be 2.5mm thick and having required nos. of hole for cable entry. Cable entry provision to be made from bottom of the panel and it should be compartmentalized. The panel surface must be pre-treated through 9 tank treatment process before painting by powder coating paint by electrostatic charging system and again to be dried up through heat chamber at 200 degrees Celsius to keep the paint on panel surface with adequate hardness. Cable chamber in the panel shall be 600mm width along the vertical. The panel shall have suitable size integral and removable lifting lug in required nos. All doors should be hinged type railway type locking arrangement and all opening shall be properly gasketted. The material and design should be approved by EIC before fabrication. 1 Set
43 31 SITC of CPRI approved cubicle type compartmentalised floor mounted LT panel board of suitable size and shape for existing panel room and made of 2mm thick CRCA sheet steel CNC fabricated panel & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint (RAL 7032) having electrolytic tinned copper Bus-bar and following equipment & accessories. Protection rank required of panel is IP-54.
44 31.01 Bus-bar:415V 800A Vertical Bus-bar system with EPR support for main power distribution by S&F suitable size electrolytic tinned copper bars to supply power to individual section. All joint must be of bolted type construction. Proper colour code to be provided by PVC heat shrink sleeves-2 nos
45 31.02 Buscoupler:630A 4 Pole 50 KA Switch disconnector MCCB without O/L & S/C protection, extended rotary handle, Spreader Terminal etc. (L&T Make DN3-630SD Cat no. CM96807 00T00G/ Eq. Siemens/ Schneider)- 1 no.\nIncoming Cable termination arrangement:Necy. electrolytic tinned copper bars of Adequate size on suitable insulation must be provided for Incoming cable connection of MCCB
46 31.03 Incoming :-a) 630A 4 Pole 50 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. (L&T Make DN3-630N Cat no. CM94104OOT1OG/ Eq. Siemens/ Schneider)- 2 nos.\nIncoming Cable termination arrangement:a) Necy. electrolytic tinned copper bars of Adequate size on suitable insulation must be provided for Incoming cable connection of MCCB
47 31.04 Outgoing:a) 400A 4 Pole 50 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. (L&T Make-DN3-400N Cat no. CM94103OOR1OG/ Eq. Siemens/ Schneider)- 2 no\nb) 250A 4 Pole 36 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. (L&TMakeDN2-250N Cat no.CM92106OOP1OG/ Eq. Siemens/ Schneider)-4 nos
48 31.05 Constructional Details:The panel to be made by 2mm thick CRCA sheet steel. The cable gland packing should be 2.5mm thick and having required nos. of hole for cable entry. Cable entry provision to be made from the bottom of the panel. All required cutting,sloting and punching for indicating arrangement , bend etc. shall be done by Automatic CNC Machine for good finish. The panel surface must be pre-treated through 9 tank treatment process before painting by powder coating paint by electrostatic charging system and again to be dried up through heat chamber at 200 degrees Celsius to keep the paint on panel surface with adequate hardness. Cable chamber in the panel shall be 600mm width along the vertical and outgoing swich busbar should be extended at cable chamber for outgoing cable connction and required nos of cable chamber to be provided in the panel so that outgoing cable not passes through any other main switch or Bus-bar. The panel shall have suitable size integral and removable lifting lug in required nos with complete base channel. All doors should be hinged type railway type locking arrangement and all opening shall be properly gasketted.
49 31.06 Metering & Indication arrangement:\na) LED Basic Multifunction Meter (L&T Cat no. WL440010OOOO or eqv. make of Schneider/Siemens)- 2 nos.\nb) CT- 800/5A,15VA, Accuracy class -1.0 (Kappa make) -6 nos.\nc) LED indicating lamp (Siemens make /Esbee make) – 6 nos (RYB Healthy for I/F,)\nd) 6ATPNMCB for Multifunction Meter-2 nos.\ne) EI danger board – 2 nos.
50 31.07 All wiring for metering & indication to be done with 1.1KV grade PVC insulated stranded FRLS copper wire of size 1.5 sq mm, each wire shall have ferrules & lugs at both end. Metering & indication wires shall be nearly bunched separately and adequately supported so as to prevent stress and strain on termination. The material and design should be approved by EIC before fabrication. 1 set
51 32 SITC of CPRI approved cubicle type compartmentalised floor mounted LT panel board of suitable size and shape for existing panel room and made of 2mm thick CRCA sheet steel CNC fabricated panel & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint (RAL 7032) having electrolytic tinned copper Bus-bar and following equipment & accessories. Protection rank required of panel is IP-54.
52 32.01 Bus-bar:415V 600A Vertical Bus-bar system with EPR support for main power distribution by S&F suitable size electrolytic tinned copper bars to supply power to individual section. All joint must be of bolted type construction. Proper colour code to be provided by PVC heat shrink sleeves-2 nos
53 32.02 Buscoupler:320A 4 Pole 50 KA Switch disconnector MCCB without O/L & S/C protection, extended rotary handle, Spreader Terminal etc. (L&T Make DN3B-400SD Cat no. CM98412OOQOOG/ Eq. Siemens/ Schneider)- 1 no.
54 32.03 Incoming :-a) 320A 4 Pole 50 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. (L&T Make DN3-400N Cat no. CM94103OOQ1OG/ Eq. Siemens/ Schneider)- 2 nos.\nIncoming Cable termination arrangement:a) Necy. electrolytic tinned copper bars of Adequate size on suitable insulation must be provided for Incoming cable connection of MCCB
55 32.04 Outgoing:a) 250A 4 Pole 50 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. (L&T Make-DN2-250N Cat no. CM92106OOP1OG/ Eq. Siemens/ Schneider)- 2 nos\nb) 125A 4 Pole 50 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. (L&TMakeDN2-250N Cat no.CM92105OOL1OG/ Eq. Siemens/ Schneider)-4 nos
56 32.05 Constructional Details:The panel to be made by 2mm thick CRCA sheet steel. The cable gland packing should be 2.5mm thick and having required nos. of hole for cable entry. Cable entry provision to be made from the bottom of the panel. All required cutting,sloting and punching for indicating arrangement , bend etc. shall be done by Automatic CNC Machine for good finish. The panel surface must be pre-treated through 9 tank treatment process before painting by powder coating paint by electrostatic charging system and again to be dried up through heat chamber at 200 degrees Celsius to keep the paint on panel surface with adequate hardness. Cable chamber in the panel shall be 600mm width along the and outgoing swich busbar should be extended at cable chamber for outgoing cable connction and required nos of cable chamber to be provided in the panel so that outgoing cable not passes through any other main switch or Bus-bar. The panel shall have suitable size integral and removable lifting lug in required nos with complete base channel. All doors should be hinged type railway type locking arrangement and all opening shall be properly gasketted.
57 32.06 Metering & Indication arrangement:\na) LED Basic Multifunction Meter (L&T Cat no. WL440010OOOO or eqv make of Schneider /Siemens)- 2 nos.\nb) CT- 600/5A,15VA, Accuracy class -1.0 (Kappa make) -6 nos.\nc) LED indicating lamp (Siemens make /Esbee make) – 6 nos (RYB Healthy for I/F,)\nd) 6ATPNMCB for Multifunction Meter-2 nos.\ne) EI danger board – 1 no.
58 32.07 All wiring for metering & indication to be done with 1.1KV grade PVC insulated stranded FRLS copper wire of size 1.5 sq mm, each wire shall have ferrules & lugs at both end. Metering & indication wires shall be nearly bunched separately and adequately supported so as to prevent stress and strain on termination. The material and design should be approved by EIC before fabrication. 1 Set