Military Engineer Services-MES has published Special Repair To Street Lights And Connected Accessories Near Butchery Under Ge Gangtok. Submission Date for this Tender is 28-05-2021. Street Lighting Tenders in GANGTOk -> Sikkim Sikkim. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-May-2021 | Corrigendum | Other | 28-05-2021 |
Name of Work: SPL REPAIR TO STREET LIGHTS AND CONNECTED ACCESSORIES NEAR BUTCHERY UNDER GE GANGTOK(2nd Call). | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supply, laying, jointing, testing in trenches or passing through pipe, 1100 Volts grade XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cable conforming to IS-7098 (Part-I) 1988, heavy duty with aluminium conductor of cross sectional area 16 Sqmm, 4 core with necessary fixing arrangements such as lungs, glands and terminal etc complete all as specified and directed. | BI01010001010000000000000515BI0100001113 | 1150 | RM |
2 | 2 | Supply, laying, jointing, testing in trenches or passing through pipe, 1100 Volts grade XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cable conforming to IS-7098 (Part-I) 1988, heavy duty with aluminium conductor of cross sectional area 10 Sqmm, 4 core with necessary fixing arrangements such as lungs, glands and terminal etc complete all as specified and directed. | BI01010001010000000000000515BI0100001114 | 1250 | RM |
3 | 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in loose/ rocky/ hard/ dense soil including forming bottom surface to required level or slope, complete all as specified and directed. | BI01010001010000000000000515BI0100001115 | 340 | CuM |
4 | 4 | Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth; for foundation, laying of cable etc. n exc 10 sq m on plan and n exc 3.0 m in depth and getting out in loose/ rocky/ hard/ dense soil including forming bottom surface to required level or slope, complete all as specified and directed. | BI01010001010000000000000515BI0100001116 | 1 | CuM |
5 | 5 | Returning filling in loose/ rocky/ hard/ dense soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed | 336 | CuM | |
6 | 6 | Removal of surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed. | 4 | CuM | |
7 | 7 | M&L for plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and as directed. | 1 | CuM | |
8 | 8 | M&L for plain cement concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and as directed. | 7 | CuM | |
9 | 9 | M&L for plain cement concrete 1:3:6 type C1 using 20mm graded crushed stone aggregate as in bond stone, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. | 1 | CuM | |
10 | 10 | M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) complete all as specified and as directed. | 15 | Each | |
11 | 11 | Supply and fixing LED street light fitting 60 Watt 230V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact resistance of IK07 and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. | 50 | Each | |
12 | 12 | M&L for GI bracket 1.5m long made out of GI dia suitable for fixing street lights bend to suitable radious including 2 sets of clamps nuts bolts washers including painting with aluminium paint etc complete all as specified and as directed. | 50 | Each Job | |
13 | 13 | M&L for laying of GI pipe 50 mm bore, light grade including fittings fixed to pole, passing through cables under the floor / road with clamps etc complete all as specified and directed. | 12 | RM | |
14 | 14 | Supply and fixing 1.5 Sqmm, 3 core, 240 Volts grade copper conductor cable heavy duty PVC insulated, round sheathed in PVC conduit all as specified and as directed. | 375 | RM | |
15 | 15 | M&L for earhing complete with galvanized steel earth plate electrode 600X600X6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to galvanized earth wire 4 mm dia , by means of galvanized iron or steel bolts, nuts, check nuts and washers of galvanized iron or of steel, GI earth wire will be protected by 15mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 1991 print and as directed. | 4 | Each Job | |
16 | 16 | Supply and laying DWC pipe SN-4 with coupler 50 mm OD,ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. laid in trenches/ fixed to pole /laying under road crossing/fixed on pavement walls with clamps complete all as specified and as directed. | 2000 | RM | |
17 | 17 | S&F Digital programmable and astronomical time switch 40A/TPN/6 kw suitable for street light complete with timer, suitable contactor, MCB of suitable rating prewired with all accessories fixed to pole with MS clamp 40 x 5 mm all as specified & directed.\nMake: Havells cat no - IHXTS0306A or equivalent in L&T / Indoasian. | 3 | Each Job | |
18 | 18 | Supply and fix in repair, Street light cable junction box made of polycarbonate, ''halogen free and weather proof', for outdoor installation (with metric knockouts for cable entry) IP-66 protection including short cable entry gland thread type with lock nut, four way terminal , GI flat strip clamps of size 25mm X 3mm with bolts, nuts and washers for fixing with MCB one 06 Amps inside the junction box complete all as specified and directed. \n(Make: HENSEL Cat No. KF-1616B or equivalent model of Havells/Sintex) | 50 | Each | |
19 | 19 | M&L for scrapping of surface of Steel tubular poles of any size with emery paper and painting of pole with one coat of primer and two coats of aluminium paint of approved make to the satisfaction of Engr in charge incl writing on yellow background with black/sky blue/white fluorescent strip 30 cm and upto 1.5m height from ground level complete all as specified and as directed. | 50 | Each | |
20 | 20 | Note:- The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. | BI01010001010000000000000515BI0100001128 |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail