East Delhi Municipal Corporation has published Civil And Electricals Work Of Fcts To Be Carried Out As Per Contract Condition Of Door To Door Collection And Transportation Of Municipal Solid Waste Sub Head Po Electrical Installation And Fans In 09 Nos. Fixed Compactor Transfer Station Under Sha Civi. Submission Date for this Tender is 20-05-2021. Electrical Maintenance Tenders in Ghazipur Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessedPVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as requiredGroupC |
2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required |
3 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.2x2.5 sq.mm + 1x2.5 sq.mm earth wire |
4 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
5 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch5/6 amps switch |
6 | 3 pin 5/6 A socket outlet |
7 | Supplying and fixing metal box of 180mm x 100mm x 60mm deep (nomnal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. |
8 | Supplying and fixing extra down rod of 20 cm length G.I. Pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.) |
9 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
10 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
11 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
12 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
13 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required |
14 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 Amp. |
15 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete withconnections, testing and commissioning etc. as required |
16 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (5 pin) |
17 | Supply of following sizes of XLPE insulated PVC Sheathed Al conductor armoured cables 1.1 KV grade on surface etc. as reqd. as per IS7098 (Part-I) /1998 as required:3.5 x 25 sq. mm |
18 | 4x 10 sq.mm |
19 | 2x 10 sq.mm |
20 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of ecessed conduit as required.25MM |
21 | Supplying & making end termination with brass compression gland & aluminum lugs for following sizes of PVC insulated & PVC sheathed /XLPE aluminum conductor cable of.1 KVgrade as reqd : 3.5 x 25sq mm (35 mm) |
22 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
23 | Supply of 18 inch(450mm) exhaust fan heavy duty complete with shutters, blades etc as reqd. 1400 RPM. |
24 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
25 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
26 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
27 | SITC of surface mounting LED luminaire suitable for 1X20 watt LED rating complete with extruded aluminium batten prewired with high efficient LEDs with the following: a) Total System Wattage 20 ±5% Wattb) Luminaries effucacy = 100 lumens/watt c) Power factor = 0.95 |
28 | SITC of 30W LED Flood Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd.a) Total System Wattage 30 ±5% Wattb) Luminaries effucacy = 100 lumens/watt c) Power factor = 0.95d) Protection Class- IP-66 |
29 | SITC of 60W LED Flood Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd.. (b) Total system wattage =60 watt +/- 5% c)Luminaire Efficacy>=100 Lm/w d) Power Factor>=0.95sf) Protection IP-66 |
30 | S& F of compartment cubical type panel board duly powder coated made out of16 SWG MS Sheet with insulated aluminium bus bar i/c interconncetioncopper wiring arrangment for mounting for switch gears, change over swichtes,MCCB i/c making the foundation brick work/ angle iron frame on floor/wall with proper locking arrangement etc. complete as required at site. Depth 30 to 60 cm |
31 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required150 A, 16kA, TPMCCB |
32 | 100A 16KA TPMCCB |
33 | Providing and fixing following capacity TP&Ndisconnector fuseswitch unit,sheet enclosure typewith side handle operation , ISI mark,making connections, etc. as required 160 A, TP&N |
34 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
35 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle) |
36 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35sqmm |
37 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
38 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy