Military Engineer Services-MES has published Repair/Maintenance Of Split Acs And Cooling Appliances With Allied Works At Hq Eac ( U ) Under Ge ( I ) Af Shillong. Submission Date for this Tender is 17-06-2021. Air Conditioner Tenders in SHILLONG Meghalaya. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-May-2021 | Amendment to tender documents | Other | 27-05-2021 |
2 | 27-May-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-06-2021 |
3 | 29-May-2021 | Bid Submission End Date Corrigendum | Date | 17-06-2021 |
Name of Work: REPAIR/MAINTENANCE OF SPLIT AC's & COOLING APPLIANCES WITH ALLIED WORKS AT HQ EAC (U) UNDER GE (I) AF SHILLONG | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Disconnecting electrical connections of Split type Air Conditioners, storing refrigerant gas in compressor of outdoor unit, splitting indoor and outdoor units, checking for faults and worn out parts/components, removing all accumulated dust and dirt of indoor and outdoor units, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassembling indoor and outdoor units, re-installing both indoor and outdoor units at respective locations (old or new locations as directed), re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required or connecting with service valves in outdoor unit and in indoor unit with threaded cast copper alloy sockets , making electrical connections, testing and commissioning complete all as directed for the following capacity Air Conditioners :-\n | |||
2 | 1.1 | Split type Airconditioner 1.5 TR capacity of any make | 2 | Each Job | |
3 | 1.2 | Split type Airconditioner 2.0 TR capacity of any make\n\n{Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, felts, lead metal balancing of blower fans, lugs, thimbles, sockets and other minor materials shall be deemed to be inclusive in quoted rate.\n(b) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against these items} | 16 | Each Job | |
4 | 2 | Disconnecting electrical connections of refrigerators, storing refrigerant gas in compressor, checking for faults and worn out parts/components, removing all accumulated dust and dirt, dry and wet cleaning, complete servicing, lubricating moving parts, replacing worn out parts/components, tightening of loose nuts/bolts, reassembling refrigerators, re-connecting refrigerant gas circulating copper tubes, charging of refrigerant gas (top up or complete new gas as directed), brazing of copper tubes wherever required, making electrical connections, testing and commissioning complete all as directed for the following capacity Refrigerators :- | |||
5 | 2.1 | Refrigerators of 180 Litre to 310 Litre capacity of any make\n\n{Notes : (a) Cost of all consumables like lubricants, grease, nuts/bolts, washers, teflon tapes, packing materials, lugs, thimbles other minor materials shall be deemed to be inclusive in quoted rate.\n(b) Refrigerant gas, replacement of worn out parts/components as described here-in-after shall be measured and paid as "Supply Only" under respective items. However fixing cost/labour for same shall be deemed to be inclusive in quoted rate against this item} | 2 | Each Job | |
6 | 3 | Supply only following spare parts/components of ACs, Refrigerators, refrigerant Gas for all these equipments/appliances complete all as directed :-\n{Notes : (a) Genuine spare parts/components and refrigerant gas as originally fitted/filled in ACs, Deep freezers, Refrigerators, Package type AC Units shall only be provided during repairs/replacement.\n(b) These genuine spare parts/components and refrigerant gas shall be procured through OEM/their authorised distributers or dealers/service frenchise/service stations (Authosised to deal in genuine spare parts/components) | |||
7 | 3.01 | Control circuit (PCB) for 2.0 TR capacity Split/Tower type AC, operating on 50 Hz electric supply of current rating, humidity control rating, operating temperature range and impedence as per Technical parameter of existing PCB installed by OEM in AC. | 2 | Each | |
8 | 3.02 | Remote circuit unit with remote controller cord, nylon fastner, tapping screw for 2.0 TR capacity Split/Tower AC as per Technical parameter of existing Remote circuit unit installed by OEM in AC. | 5 | Each | |
9 | 3.03 | Copper tube of size 3/8 inch outer dia, 0.8mm thick ISI marked for Air conditioners. | 10 | RM | |
10 | 3.04 | Copper tube of size 5/8 inch outer dia, 1.0mm thick ISI marked for Air conditioners. | 10 | RM | |
11 | 3.05 | Standard strainer & capillary tube of compressor for 2.0 TR Split/Tower type A/C as per Technical parameter of existing strainer & capillary tube installed by OEM in AC. | 1 | Each | |
12 | 3.06 | Hermatically sealed, uncut rotary type compressor for 1.5 TR capacity Split/Tower type AC as per Technical parameter of existing compressor installed by OEM in AC. | 2 | Each | |
13 | 3.07 | Hermatically sealed, uncut rotary type compressor for 2.0 TR capacity Split/Tower type AC as per Technical parameter of existing compressor installed by OEM in AC. | 5 | Each | |
14 | 3.08 | Referigent gas R-22. | 5 | Kg | |
15 | 3.09 | Referigent gas R-32. | 5 | Kg | |
16 | 3.1 | Referigent gas F-22. | 1 | Kg | |
17 | 3.11 | LCD/LED display unit for Split type AC of 1.5 TR/2.0 TR capacity. | 1 | Each Set | |
18 | 3.12 | Air equalizer for Split type AC of 1.5 TR/2.0 TR capacity. | 2 | Each | |
19 | 3.13 | Swing motor of indoor unit of Split type AC 1.5 to 2 TR capacity as per Technical parameter of existing motor installed by OEM in ACs. | 1 | Each | |
20 | 3.14 | Indoor fan motor of Split type AC 1.5 to 2 TR capacity as per Technical parameter of existing motor installed by OEM in ACs. | 2 | Each | |
21 | 3.15 | Supply only Indoor fan motor capacitor for split AC 1.5/2 TR capacity. | 2 | Each | |
22 | 3.16 | Outdoor fan motor for 1.5 to 2.0 TR Capacity Split type AC as per Technical parameter of existing outdoor fan motor installed by OEM in ACs. | 5 | Each | |
23 | 3.17 | Dual run Capacitor (Starting/running) for 1.5 to 2.0 TR Capacity for outdoor unit of Split type AC as per Technical parameter of existing capacitor installed by OEM in ACs. | 5 | Each | |
24 | 3.18 | Outdoor fan Blade for 2.0 TR Capacity Split type AC as per Technical parameter of existing fan blades installed by OEM in ACs. | 1 | Each | |
25 | 3.19 | Service Valve suitable for 1/2 inch outer dia copper tubing. | 2 | Each | |
26 | 3.2 | Service Valve suitable for 1/4 inch outer dia copper tubing. | 1 | Each | |
27 | 3.21 | Condensor Coil for outdoor unit of split AC 2.0 TR capacity as per Technical parameter of existing Condensor Coil installed by OEM in ACs. . | 1 | Each | |
28 | 4 | S & F in repairs Thermostate switch for referigerator 180 to 310 ltrs capacity of reputed make. | 1 | Each | |
29 | 5 | S & F in repairs rubber gasket of superior quality for door of refrigerator of any capacity. | 2 | Each | |
30 | 6 | S & F in repairs Compressor starting relay for refrigerators of any capacity. | 1 | Each | |
31 | 7 | S & F in replacement Sealed maintenance free Lead acid battery 12 V 42 AH complete all as directed.\nModel and Make : Model " Powersafe" of Make "Exide" or equivalent model of Make LUMINOUS/MICROTEK/AMRON. | 30 | Each | |
32 | 8 | S & F in replacement Electrice Auto wound voltage converter suitable step down type to convert 220 volts into 110 volts 2000W rating including necessary electrical connection complete all as directed. | 1 | Each |