Military Engineer Services-MES has published Repair/Maint Of Cooling Appliances In Tech Area At Af Stn Gwalior. Submission Date for this Tender is 12-06-2021. Air Conditioner Tenders in GE (AF) TA Gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-May-2021 | BOQ Ammendment | BOQ | 28-05-2021 |
2 | 27-May-2021 | Corrigendum to critical dates | Date | 05-06-2021 |
3 | 05-Jun-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-06-2021 |
Name of Work: REPAIR/MAINT OF COOLING APPLIANCES IN TECH AREA AT AF STN GWALIOR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Disconnecting,dismantling and taking out the defective/ non functional desert cooler of any description and in any position and any floor installed at direct approch (where any ladders and other T&P are not required to remove the desert cooler from position) strip opening of desert cooler, cleaning servicing oiling & greasing etc of desert cooler taking out and removing unserviceable/defective parts and internal wiring, replacement of unserviceable & damaged parts and internal wiring, reassembling & testing of the desert cooler complete all as specified and directed\nNote :- (i) The replacement of defective/ nonfuctional parts shall be measured & paid separatly as ` supply only' under respective item of schedule A and fixing charges for new items are deemed to be included under this item and replacement of unserviceable/damaged body portion i.e panel/switch board/Pump/Motor/bottom /top/grills/frame etc of the desert cooler shall also be measured and paid for separatly under appropriate item of schedule `A' ./BOQ.\n | BI01010001010000000000000515BI0100001113 | 70 | Each Job |
2 | 2.01 | Supply only of the following parts for existing desert cooler of any description, any capacity, any make and in any position complete all as specified and directed.\nNote :- (i) Make of the parts must be same as per existing desert cooler (ii) The cost of fixing and testing of spare parts is deemed to be included under schedule A/BOQ Sl No 1.00 here-in-before\n\n(a) 15 mm dia PVC flexible water pipe | BI01010001010000000000000515BI0100001114 | 120 | RM |
3 | 2.02 | (b) PVC distributor 3 way for 15 mm dia water distribution | BI01010001010000000000000515BI0100001115 | 60 | Each |
4 | 2.03 | (c ) 1.5 sqmm 3 core PVC insulated copper cable round type suitable for 1100 volts grade \nMake : Havells/L&T/Polycab. | BI01010001010000000000000515BI0100001116 | 100 | RM |
5 | 2.04 | (d) Submersible pump, PVC body, for desert cooler single phase, 230 volt AC flow rate 1100LPH, Max head 1850 mm \nMake:- Balaji or equivalent make as approved by GE. | BI01010001010000000000000515BI0100001117 | 90 | Each |
6 | 2.05 | (e) PVC switch board with and incl piano type switch 5 Amps-02 Nos one way and 1 No selctor switch 4 way 15 Amp 230 volts for speed control and one red indicator incl wiring complete as directed | BI01010001010000000000000515BI0100001118 | 20 | Each\nSet |
7 | 2.06 | (f) Air curtain panels (side and back removale panels) of any description and size for different size of desert coolers made to shape and size with using 20 SWG guage PGI sheets as per requirement incl necessary moulding etc to suit the existing desert cooler openings | BI01010001010000000000000515BI0100001119 | 45 | Set of three |
8 | 2.07 | (g) Aluminium fan blade (set of three blades) for desert cooler motor of any description to match existing motor | BI01010001010000000000000515BI0100001120 | 40 | Each set |
9 | 2.08 | (h) Wood wool pads of required size as apporved (three in each) for desert cooler | BI01010001010000000000000515BI0100001121 | 80 | Set of three |
10 | 2.09 | (j) desert cooler fan motor of existing make/model/ capcity/sweep, 900/1400 RPM including making connection complete all as specified and directed | BI01010001010000000000000515BI0100001122 | 40 | Each |
11 | 2.1 | (k) desert cooler fan motor of existing make/model/ capcity/sweep, 1200/1400 RPM including making connection complete all as specified and directed | BI01010001010000000000000515BI0100001123 | 30 | Each |
12 | 2.11 | (l) Chicken wire mess having hexagonal wire mesh 15mm size mesh and 0.5mm dia of wire for supporting to the wood wool pads. | BI01010001010000000000000515BI0100001124 | 60 | Each set |
13 | 2.12 | (m) Front grills of existing shape and size and made out of 20 SWG PGI sheet. | BI01010001010000000000000515BI0100001125 | 30 | Each |
14 | 2.13 | (n) 15mm bore ball brass valves high pressure with polythene float and fly nut complete | BI01010001010000000000000515BI0100001126 | 25 | Each |
15 | 2.14 | (o) 15mm bore Gun metal gate valve with iron wheel head, screwed both end for iron pipe \nMake NMC/BIR/Leader | BI01010001010000000000000515BI0100001127 | 25 | Each |
16 | 2.15 | (p ) PVC connection pipe 15mm size 450 mm length complete with PTMT nuts on both ends. | BI01010001010000000000000515BI0100001128 | 65 | Each |
17 | 3 | M&L for preparation of steel surfaces of desert cooler and applying one coats of synthetic enamelled paint(blue) on all exterior surfaces and applying one coat of black bituminous paint on all interior surfaces including bottom surfaces complete all as specified and directed | BI01010001010000000000000515BI0100001129 | 60 | Each Job |
18 | 4 | Disconnecting, di mantling and taking out the non functional Water Coolers of any description, checking, replacement of unserviceable parts including testing complete all as specified and directed. \nNote :- Replacement of new parts shall be measured and paid separately under relevant item of Sch 'A'/ BOQ as Supply only.\n | BI01010001010000000000000515BI0100001130 | 35 | Each Job |
19 | 5.01 | Supply only of the following parts for existing water cooler of any description, any capacity, any make and in any position complete all as specified and directed.\nNote :- (i) Make of the parts must be same as per existing water cooler \n(ii) The cost of fixing and testing of spare parts is deemed to be included under schedule A/BOQ Sl No 4.00 here-in-before\n(a) Base tray stainless steel for 40/80 and 60/120 ltrs capacity | BI01010001010000000000000515BI0100001131 | 3 | Each |
20 | 5.02 | (b) Base tray stainless steel for 150/150 ltrs capacity | BI01010001010000000000000515BI0100001132 | 3 | Each |
21 | 5.03 | (c) Side cover stainless steel for 40/80 ltrs capacity | BI01010001010000000000000515BI0100001133 | 3 | Each set of three |
22 | 5.04 | (d) Side cover stainless steel for 60/120 ltrs capacity | BI01010001010000000000000515BI0100001134 | 3 | Each set of three |
23 | 5.05 | (e) Side cover stainless steel for 150/150 ltrs capacity | BI01010001010000000000000515BI0100001135 | 3 | Each set of three |
24 | 5.06 | (f) Water storage tank with chiller made of stainless steel incl copper tube for 40/80 Ltrs capacity | BI01010001010000000000000515BI0100001136 | 2 | Each |
25 | 5.07 | (g) Water storage tank with chiller made of stainless steel incl copper tube for 60/120 Ltrs capacity | BI01010001010000000000000515BI0100001137 | 2 | Each |
26 | 5.08 | (h) Water storage tank with chiller made of stainless steel incl copper tube for 150/150 Ltrs capacity | BI01010001010000000000000515BI0100001138 | 2 | Each |
27 | 5.09 | (j) Water tank chiller's top cover made of stainless steel for 40/80 ltrs capacity | BI01010001010000000000000515BI0100001139 | 2 | Each |
28 | 5.1 | (k) Air cooled condenser with ventury, copper 3 row for 40/80 ltrs capacity | BI01010001010000000000000515BI0100001140 | 2 | Each |
29 | 5.11 | (l) Air cooled condenser with ventury, copper 3 row for 60/120 ltrs capacity | BI01010001010000000000000515BI0100001141 | 5 | Each |
30 | 5.12 | (m) Air cooled condenser with ventury, copper 4 row for 150/150 ltrs capacity | BI01010001010000000000000515BI0100001142 | 4 | Each |
31 | 5.13 | (n) Relay unit currrent type\n Make : Kilxen, Model 5441/Electrica or other make as approved | BI01010001010000000000000515BI0100001143 | 20 | Each |
32 | 5.14 | (o) Relay pin type (Potential type) Make Tecumseh Model No 1062/KCL 85001, 02, 03, 04 or other equivalent make as approved by GE. | BI01010001010000000000000515BI0100001144 | 20 | Each |
33 | 5.15 | (p) Thermostat 220 volts, Make Indfoss/Renutrol /Rockwell | BI01010001010000000000000515BI0100001145 | 15 | Each |
34 | 5.16 | (q) Over load protector suitable for 40/80 Ltr.60/120 Ltr water cooler Make Kilxen/KCL/Electrica | BI01010001010000000000000515BI0100001146 | 15 | Each |
35 | 5.17 | (r) AC electric condenser motor 25 watt, 230 volts, 1250/1400 RPM, single speed Make AUE/GE | BI01010001010000000000000515BI0100001147 | 10 | Each |
36 | 5.18 | (s) AC electric condenser motor 30 to 35 watt, 230 volts, 900 /1400 RPM, single speed Make AUE/GE | BI01010001010000000000000515BI0100001148 | 10 | Each |
37 | 5.19 | (t) AC electric condenser motor 75 to 90 watt 230 volts 1400 RPM single speed Make AUE/GE | BI01010001010000000000000515BI0100001149 | 15 | Each |
38 | 5.2 | (u) Brass nipple 15 mm dia for inlet and out let connection of water cooler any type/size incl PVC connection 15 mm dia with brass coupling on both ends | BI01010001010000000000000515BI0100001150 | 15 | Each Set |
39 | 5.21 | (v) Drain pipe PVC flexible ¼" dia . | BI01010001010000000000000515BI0100001151 | 30 | RM |
40 | 5.22 | (w) end circle clip for Drain pipe 1/4" dia | BI01010001010000000000000515BI0100001152 | 30 | Each |
41 | 5.23 | (x) Wiring kit of flexible PVC insulated copper condutor cable of existing size | BI01010001010000000000000515BI0100001153 | 15 | Each |
42 | 5.24 | (y) CP brass push cock 15mm dia (ISI marked) inner/outer threaded as directed :Make: Prayag/ Jaquar or equivalent make as approved by GE | BI01010001010000000000000515BI0100001154 | 30 | Each |
43 | 5.25 | (z) Harmetic sealed unit compresssor of capcity 40/80 Ltrs Model No. KCE443 of water cooler incl vaccum testing and filling of refrigerant gas to required pressure Make Emerson copland/ carrier/ Blue star/Tecumseh | BI01010001010000000000000515BI0100001155 | 8 | Each |
44 | 5.26 | (ab) Harmetic sealed unit compresssor of capcity 60/120 Ltrs Model No. KCE461 of water cooler incl vaccum testing and filling of refrigerant gas to required pressure Make Emerson copland/ carrier/ Blue star/Tecumseh | BI01010001010000000000000515BI0100001156 | 3 | Each |
45 | 5.27 | (ac) Harmetic sealed unit compresssor of capcity 150/150 LtrsModel NO.AHR13/513 of water cooler incl vaccum testing and filling of refrigerant gas to required pressure Make Emerson copland/ carrier/ Blue star/Tecumsah\nNote for Sl No 5.26 and 5.27The cost of fixing brazing to suction and discharge line and testing of compressor at site is deemed to be included under schedule'A'/BOQ Sl No 4.00 here-in-before(ii) The rate quoted against items is demeed to be inclusive of labour for filling of refrigerant gas, However the refrigerent gas is shall be issued under schedule 'B' free for filling. | BI01010001010000000000000515BI0100001157 | 3 | Each |
46 | 5.28 | (ad) Fan blade suitable for 40/80 ltrs capacity | BI01010001010000000000000515BI0100001158 | 5 | Each |
47 | 5.29 | (ael) Fan blade suitale for 60/120 ltrs capacity | BI01010001010000000000000515BI0100001159 | 5 | Each |
48 | 5.3 | (af) Fan blade suitable for 150/150 ltr capacity | BI01010001010000000000000515BI0100001160 | 5 | Each |
49 | 6 | Disconnecting, dismanling and taking out the non functional Refrigerator of capacity 165 to 360 ltrs of any description, checking,replacement of unserviceable parts including testing complete all as specified and directed. Note :- Replacement of new parts shall be measured and paid separately under relevant item of Sch 'A'/BOQ as Supply only.\n | BI01010001010000000000000515BI0100001161 | 12 | Each Job |
50 | 7.01 | Supply only of the following new parts for existing refrigerator of any description, any capacity of 165 to 360 ltrs & any make and in any position complete all as specified and directed.\nNote :- (i) Make of the parts must be same as per existing refrigerator (ii) the cost of fixing and testing of spare parts is deemed to be included under schedule A \n(a) Main door gasket magnetic type | BI01010001010000000000000515BI0100001162 | 10 | RM |
51 | 7.02 | (b) Thermostat switch with knob 230 volt suitable for single door refrigerator Make Indofos/Godrej/Annapurna | BI01010001010000000000000515BI0100001163 | 8 | Each |
52 | 7.03 | (c) Thermostate switch with knob 230 volts suitable for double door refrigerator of capacity 230 to 360 ltrs \nMake: Indofoss/Godrej/Annapurna | BI01010001010000000000000515BI0100001164 | 8 | Each |
53 | 7.04 | (d) Relay box type 220 volts 3 pin/4 pin \nMake: KCL/Rentrol/Indofoss/Annapurna | BI01010001010000000000000515BI0100001165 | 10 | Each |
54 | 7.05 | (e) Freezer door with spring & clamp | BI01010001010000000000000515BI0100001166 | 10 | Each |
55 | 7.06 | (f) Pin type/screw type bulb \nMake: Philip/bajaj/Crompton | BI01010001010000000000000515BI0100001167 | 15 | Each |
56 | 7.07 | (g) Condensor water drain off tray of pvc same as per existing model complete | BI01010001010000000000000515BI0100001168 | 10 | Each |
57 | 7.08 | (h) Door switch 230 volts | BI01010001010000000000000515BI0100001169 | 10 | Each |
58 | 7.09 | (j) Chiller tray plastic. | BI01010001010000000000000515BI0100001170 | 10 | Each |
59 | 7.1 | (k) Refrigerator freezer coil, roll bound type for 165 ltr to 230 ltrs capacity | BI01010001010000000000000515BI0100001171 | 10 | Each |
60 | 7.11 | (l) Refrigerator freezer coil, roll bound type for 250 ltrs to 360 ltrs | BI01010001010000000000000515BI0100001172 | 10 | Each |
61 | 7.12 | (m) Bulb holder assembly complete | BI01010001010000000000000515BI0100001173 | 10 | Each |
62 | 7.13 | (n) Inner PUF Insulation for 165 to 250 ltr capacity | BI01010001010000000000000515BI0100001174 | 5 | Each |
63 | 7.14 | (o) Innter PUF Insulation for 275 to 330 ltr capacity | BI01010001010000000000000515BI0100001175 | 5 | Each |
64 | 7.15 | (p) PVC inner cabinet moulded in shape suitable for capacity 165 to 230 ltrs | BI01010001010000000000000515BI0100001176 | 5 | Each |
65 | 7.16 | (q) PVC door cabinet (factory made) moulded in shape suitable for capcity 275 to 330 ltrs | BI01010001010000000000000515BI0100001177 | 5 | Each |
66 | 7.17 | (r) Condesner coil for 165 to 230 ltrs capacity | BI01010001010000000000000515BI0100001178 | 10 | Each |
67 | 7.18 | (s) Fan motor of frost free for double door refrigerator of capcity 300 to 360 ltrs | BI01010001010000000000000515BI0100001179 | 10 | Each |
68 | 7.19 | (t) Bi-metalic thermostat of capacity -5 ºC cut in temperatur for 300 to 360 ltr capacity | BI01010001010000000000000515BI0100001180 | 10 | Each |
69 | 7.2 | (u) Fuse for bi-metalic thermostat of 65 ºC /70ºC for 300 to 360 ltrs capacity | BI01010001010000000000000515BI0100001181 | 10 | Each |
70 | 7.21 | (v) PCB for 265 ltrs capacity | BI01010001010000000000000515BI0100001182 | 8 | Each |
71 | 7.22 | (w) PCB for 300 to 330 ltrs capacity | BI01010001010000000000000515BI0100001183 | 8 | Each |
72 | 7.23 | (x) Timer for double door refrigerator \nMake: Samsung /WirlpoolGodraj/LG | BI01010001010000000000000515BI0100001184 | 10 | Each |
73 | 7.24 | (y) Sealed unit compressor Model No. THK 1340 for 165 ltrs capacity incl vacuum testing and filling of refrigerant gas to required pressure make Godrej/Teccumesh /Voltas/ Whirpool/Kirloskar copland | BI01010001010000000000000515BI0100001185 | 6 | Each |
74 | 7.25 | (z) Sealed unit comrpressor Model No. THK 1352/51 for 220 to 330 ltrs capacity incl vacuum testing and filling refrigerant gas to required pressure make Godrej/Teccumesh /Voltas/ Whirpool/Kirloskar copland\nNote for Sl No. 2.24 & 2.25 : (i) the cost of fixing brazing to suction and discharge line and testing of compressor at site is deemed to be included under schedule A/ BOQ Sl No 6.00 \n(ii) The rate quoted against items is demeed to be inclusive of labour for filling of refrigerant gas. However, the refrigerent gas shall be issued under Schedule 'B' free for filling | BI01010001010000000000000515BI0100001186 | 6 | Each |
75 | 7.26 | (aa) Vegetable tray of any capacity refrigerator\n | BI01010001010000000000000515BI0100001187 | 8 | Each |
76 | 8 | Taking down old unserviceable submain wiring including PVC conduit of any description and any type including making good to disturbed surfaces complete all as specified and directed | BI01010001010000000000000515BI0100001188 | 150 | RM |
77 | 9.01 | M&L for Sub main wiring with PVC insulated FRLS cable LT 1100 volts grade with stranded copper conductor and drawn into and incl with concealed non metalic rigid PVC coduit alongwith earth wire and connected to comman earth dolly of the following size complete all as specified and directed. Make of cable :- Havells/L&T/Polycab\n(a) 2x4 sqmm ( 2 single run) with one contineous wire of size 2.5 sqmm | BI01010001010000000000000515BI0100001189 | 50 | RM |
78 | 9.02 | (b) 2x6 sqmm ( 2 single run) with one contineous wire of size 4 sqmm | BI01010001010000000000000515BI0100001190 | 50 | RM |
79 | 9.03 | (c) 4x6 sqmm (4 single run) with two contineous wire of size 4 sqmm | BI01010001010000000000000515BI0100001191 | 50 | RM |
80 | 10 | Taking down old unserviceable PVC conduit of any size complete all as specified and directed | BI01010001010000000000000515BI0100001192 | 150 | RM |
81 | 11 | M&L for non metalic rigid PVC conduit, medium grade ISI marked of size 25mm dia fixed on angle with suitable size clamp with machine screw incl all other accessories complete all as specifed and directed | BI01010001010000000000000515BI0100001193 | 150 | RM |
82 | 12 | Taking down old unserviceable PVC cable of any conductor and any core complete all as specified and directed | BI01010001010000000000000515BI0100001194 | 500 | RM |
83 | 13.01 | S&F PVC insulated & sheathed copper round cable 1100 volts of following size incl copper thimble/pin type lugs connecting both side and testing complete all as specified and directed. Make :- L&T/Havells\n(a) Size 2.5 sqmm 6 core | BI01010001010000000000000515BI0100001195 | 100 | RM |
84 | 13.02 | (b) Size 2.5 sqmm 3 core | BI01010001010000000000000515BI0100001196 | 100 | RM |
85 | 13.03 | (c ) Size 4.0 Sqmm 3 core | BI01010001010000000000000515BI0100001197 | 100 | RM |
86 | 13.04 | (d ) size 1.5 sqmm 3 core | BI01010001010000000000000515BI0100001198 | 100 | RM |
87 | 13.05 | (e) size 1.0 sqmm 3 core | BI01010001010000000000000515BI0100001199 | 100 | RM |
88 | 14 | S & F plug top 3 pin 20 amp complete all as specified and directed. | BI01010001010000000000000515BI0100001200 | 50 | Each |
89 | 15 | S & F plug top 3 pin 6 amp | BI01010001010000000000000515BI0100001201 | 100 | Each |
90 | 16 | Disconnecting & taking out the non -functional voltage corrector (stabilizer of any description and in any position & strip opening of voltage corrector (stabilizer) of following capacity single phase air cooled of any make, taking out unserviceable/defective wiring & parts, cleaning and servicing complete incl replacement of unserviceable parts with new one and unserviceable wiring with new PVC insulated and unseathed stranded copper conductor cable of existing size, reassembling, connecting and testing incl cleaning the exposed surfaces of stabilizer complete all as specified and directed\nNote :- Replacement of unserviceable parts shall be measured and paid separatly as supply onl. Fixing charges is deemed to be included in quoted rate. \n(a) 7.5 to 10 KVA | BI01010001010000000000000515BI0100001202 | 50 | Each |
91 | 17 | (b) 4/5 KVA | BI01010001010000000000000515BI0100001203 | 80 | Each Job |
92 | 18.01 | Supply only of following new parts suitable for 7.5 to 10 KVA, voltage stabilizer complete all as specified and directed\nNote - (i) Fixing and testing element of the these items is deemed to include under respective schedule `A' item \n(ii) Make, shape and size of part shall be the same as per existing or as directed\n(a) Power transformer input 140-280 volts & out put 220 volt ± 9% for 7.5 to 10 KVA | BI01010001010000000000000515BI0100001204 | 12 | Each |
93 | 18.02 | (b) Power transformer input 140-280 volts & out put 220 volt ± 9% for 4/5 KVA | BI01010001010000000000000515BI0100001205 | 20 | Each |
94 | 18.03 | (c) Relay 24 volts singal change over 60 Amps | BI01010001010000000000000515BI0100001206 | 40 | Each |
95 | 18.04 | (d) Relay 24 volts singal change over 30 Amps | BI01010001010000000000000515BI0100001207 | 40 | Each |
96 | 18.05 | (e) Axillary transformer 12/24 volts | BI01010001010000000000000515BI0100001208 | 20 | Each |
97 | 18.06 | (f) PCB 4 to 10 KVA suitable for existing make of stabilizer | BI01010001010000000000000515BI0100001209 | 40 | Each |
98 | 18.07 | (g) Volt meter 0-300 Volts 50mm square type | BI01010001010000000000000515BI0100001210 | 50 | Each |
99 | 18.08 | (h) Switch SPDT 220 volt 1 Amp | BI01010001010000000000000515BI0100001211 | 20 | Each |
100 | 18.09 | (j) Indicator lamp green/red 220 volts | BI01010001010000000000000515BI0100001212 | 20 | Each |
101 | 18.1 | (k) Toggle switch 15 Amps 2 way 220 volts | BI01010001010000000000000515BI0100001213 | 10 | Each |
102 | 19 | Taking down old unserviceable voltage stablizer of capacity 5KVA/4 KVA | BI01010001010000000000000515BI0100001214 | 30 | Each |
103 | 20 | Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor, type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and directed Make:- Blue Bird/V-Guard or equivalent | BI01010001010000000000000515BI0100001215 | 15 | Each |
104 | 21 | Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed\nMake:- Blue Bird / V-Guard or equivalent | BI01010001010000000000000515BI0100001216 | 15 | Each |
105 | 22 | Disconnecting and taking out existing defective non functional dehumidifier of capcity 600 CFM of make ` BRY air model FEB 1000 in any position, three phase, 50 HZ, strip opening, cleaning and servicing of dehumidifire including taking out and removing unserviceable/defective wiring & parts, painting the bottom with one coat of black synthetic enamelled paint, reassembling and testing of the dehumidifire complete all as specified and directed\nNote (i) The replacement of defective/nonfuctional parts shall be measured and paid sepratly as "supply only" under appropriate item of Sch A and fixing charges for new items are deemed to be included under this item.\n(ii) The rate for above items are deemed to include for transportation of dehumidifier to & from work shop as approved by Engr-in-charge for necessary repair and testing & replacement of necessary unserviceable screws/nuts/bolts/washer/packing etc with new one. | BI01010001010000000000000515BI0100001217 | 1 | Each |
106 | 23.01 | Supply only of the following spare parts for BRY AIR make dehumidifier & Model NO EFB-1000 complete all as specified and directed\nNote- The Elements of fixing & testing of the item is deemed to be included in the rates quoted by the contractor for respective schedule A here-in-before\n(a) Heater 2 KW | BI01010001010000000000000515BI0100001218 | 10 | Each |
107 | 23.02 | (b) Micro switch MCL-15D | BI01010001010000000000000515BI0100001219 | 1 | Each |
108 | 23.03 | (c ) Thermostate | BI01010001010000000000000515BI0100001220 | 2 | Each |
109 | 23.04 | (d) Air pressure switch | BI01010001010000000000000515BI0100001221 | 2 | Each |
110 | 23.05 | (e) Timer set 800-M | BI01010001010000000000000515BI0100001222 | 2 | Each |
111 | 24 | M&L for MCB Plug and socket DBs with one MCB SP 25 /32 Amps, 10 KA, 'C' Series complete all as specified and directed Make of Plug and socket DB :- Legrand cat No. 607841 or equivalent | BI01010001010000000000000515BI0100001223 | 50 | Each |