}

Repairs And Maintenance Of Acs , Water Coolers And Water Purifier Under Age B/R New Mangalore Under Ge ( I ) ( Cg ) Goa, NEW MANGALORE-Karnataka

Military Engineer Services-MES has published Repairs And Maintenance Of Acs , Water Coolers And Water Purifier Under Age B/R New Mangalore Under Ge ( I ) ( Cg ) Goa. Submission Date for this Tender is 24-07-2021. Tanks and Cylinders Tenders in NEW MANGALORE Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

27832296
Corrigendum : Repairs And Maintenance Of Acs , Water Coolers And Water Purifier Under Age B/R New Mangalore Under Ge ( I ) ( Cg ) Goa
Open Tender
Indian
Karnataka
NEW MANGALORE
24-07-2021

Tender Details

Repairs And Maintenance Of Acs , Water Coolers And Water Purifier Under Age B/R New Mangalore Under Ge ( I ) ( Cg ) Goa , Air Conditioner: Servicing Of Split Type Ac Unit Of Any Capacity/Any Make By Removing Dust With Suitable Method , Cleaning Of Air Filters , Tightening Of Loose Wire , Nuts , Bolts , Washers , Servicing Of Condenser Motor/ Blower , By Oiling , Greasing , Required Welding/Bracing , Replacement Of Worn Out Rubber Bushes Of Condensor Motor , Setting Of Grill Alignment & Knobs , Checking For Any Leakages , Provision Of Thermocoal For Air Tightness , Testing Etc Complete All As Specified And Directed . , M & L Painting The Outdoor Unit Of Split Ac Of Any Capacity/Any Make And Its Stand By Synthetic Enamel Spray Paint As Existing Colour And Writing Mes No Complete All As Specified And Directed . , Removing The Unserviceable Blower Motor From The Split Ac 1 . 5/2 Ton Unit And M&L For Rewinding Of Blower Motor , Single Phase , With Super Enamelled Copper Wire Of Existing Gauge Including Replacement Of Gunmetal Bush Of Suitable Size , Cleaning , Greasing And Refixing Of Motor , Connecting Up All Including Testing And Refixing Complete All As Specified And Directed . , S & F In Replacement Blower Motor Suitable For Split Type Ac 1 . 5/2 Ton Out Door Unit Single Ended Or Double Ended Shaft As Per Existing One Complete All As Specified And Directed . , Removing The Unserviceable Compressor From Split Type Ac And Supply And Fix New Compressor Suitable For 1 . 5 Ton Split Type A/C All Including Fixing In Original Position , Connecting Up , Testing , Gas Charging , Pressure Testing , Cleaning , Condensing And Cooling Coils , Welding , Bracing And Also Including Required Length Of Capacity Tube And Strainer/Filter And Painting Of Base Plate Testing Complete All As Per Existing One Complete All As Specified And Directed . , Removing The Unserviceable Compressor From Split Type Ac And Supply And Fix New Compressor Suitable For 2 Ton Split Type A/C All Including Fixing In Original Position , Connecting Up , Testing , Gas Charging , Pressure Testing , Cleaning , Condensing And Cooling Coils , Welding , Bracing And Also Including Required Length Of Capacity Tube And Strainer/Filter And Painting Of Base Plate Testing Complete All As Per Existing One Complete All As Specified And Directed . , S & F In Replacemnt The Copper Piping ( Suction And Discharge ) And Power Cable Including The Thermal Insulation Complete All As Specified And Directed . , S & F In Repair Indoor Cooling Coil Made Up Of Copper Tubing And Copper/Aluminium Cooling Fins All As Per Sample And As Suitable For 1 . 5/2 Ton Capacity Split Type Ac Complete All As Specified And Directed . , S & F In Repair Condenser Coil Made Up Of Copper Tubing And Copper/Aluminium Cooling Fins All As Per Sample And As Suitable For 1 . 5/2 Ton Capacity Split Type Ac Complete All As Specified And Directed . , S & F In Replacement Room Sensor All As Per Existing One And Suitable For 1 . 5/2 Ton Capacity Split Ac Complete All As Specified And Directed . , S & F In Replacement Running Capacitor 60 Mfd 440 V Ac Suitable For 1 . 5/2 Ton Capacity Ac Complete All As Specified And Directed . , S & F In Replacement Of Capacitor 6 Mfd 440 Volts Suitable For Condenser Motor Of 1 . 5/2 Ton A/C Capacity Complete All As Specified And Directed . , S & F In Replacement Coil Sensor All As Per Existing One And Suitable For 1 . 5/2 Ton Capacity Split Ac Complete All As Specified And Directed . , S & F In Replacement Of Condnsor Fan Blade All As Per Existing One And Suitable For 1 . 5/2 Ton Capacity Split Ac Complete All As Specified And Directed . , S & F In Replacement Sheet Metal Enclosure , Single Pole Neutral , With Two Pin And Earth Plug Top And Socket Complete With One No Of Mcb Sp , 20 A , 240 V Complete All As Specified And Directed . , Tracing Out Leakage From Suction Line , Discharge Line , Evaporation Condenser , Filter , Capillary Tube By Suitable Method Including Bracing , Welding , Replacement Of Filter Strainer Charging Line And Filling Of Gas Charging ( R-134 A ) Aprox 0 . 75 Kg Or Prussure As Prescribed By Manufacturer , Leak Testing & Commissioning Of Split Type A/C Of Any Type , Any Capacity , Any Make Complete All As Specified And Directed . , S & F In Replacement Of Electronic Circuit Complete Including Controlling Unit ( Ie Remote ) All As Per Existing One And Suitable For 1 . 5/2 Ton A/C Complete All As Specified And Directed . , S & F In Replacement Of Printed Circuit Board ( Pcb ) Complete Including Controlling Unit ( Ie Remote ) All As Per Existing One And Suitable For 2 Tr Cassette Type Split Ac Complete All As Specified And Directed . , S & F In Replacement Of Receiver Pcb Complete Including The Chords Suitable For 1 . 5/2 Tr Split Ac All As Per Existing One Complete All As Specified And Directed . , Water Cooler:- Removing The Unserviceable Condenser Fan Motor From The Water Cooler Of 40/120 Ltr Capacity And M&L For Rewinding Of Condenser Fan Motor Of Capacity 1 Hp 1350 Rpm Single Phase , With Super Enamelled Copper Wire Of Existing Gauge Including Replacement Of Gunmetal Bush , Cleaning , Greasing And Refixing Of Motor , Connecting Up All Including Testing And Refixing Complete All As Specified And Directed . , Removing Unserviceable Condenser Fan Motor From The Water Cooler Of Any Capacity And Supply And Fix In Replacement New Condenser Fan Motor 230 V , 50 Hz As Per Sample Existing Suitable For 40/120 Ltr Capacity Storage Type Water Cooper Complete All As Specified And Directed . , Removing The Unserviceable Compressor From Water Cooler And Supply And Fix New Compressor Suitable For 120 Ltr Capacity Of Water Cooler Including Fixing In Original Position , Connecting Up , Testing , Gas Charging , Pressure Testing , Cleaning Of Cooling Coils Necesary Welding/ Brazing And Including Required Capillary Tube Complete All As Specified And Directed . , S & F In Replacement Starting Relay For 40/120 Ltr Capacity Water Cooler Including Over Load Protector Complete Assembly Complete All As Specified And Directed . , Tracing Out Leakage From Suction Line , Discharge Line , Evaporation Condenser , Filter , Capillary Tube By Suitable Method Including Bracing , Welding , Replacement Of Filter Strainer Charging Line And Filling Of Gas Charging ( R-134 A ) Aprox 0 . 75 Kg Or Prussure As Prescribed By Manufacturer , Leak Testing & Commissioning For Water Cooler 40/120 Ltr Storage Capacity , Any Type , Any Make All Complete All As Specified And Directed . , M & L Servicing And Cleaning Of The Water Cooler 40/80/120 Ltr Capacity By Removing Dust With Suitable Method , Cleaning Of Water Tank , Inlet And Outlets Including Leak Proofing/ Repairing Of Storage Tank , Necessary Repairs To Wiring Of The Water Cooler Unit ( I . E ) Internal Wiring Connections To Compressor , Condenser Motor Etc . , Supply And Replacement Of Damaged Hinges , Nuts , Bolts , Clamps , Washers , Screws , Tightening Of Loose Parts , Servicing Of Condenser Motor By Oiling , Greasing , Required Welding/Bracing To The Any Part Of The Water Cooler , Repairs To Chromium Plated Drain Tray , Replacement Of Worn Out Mounting Rubber Bushes Of Condenser Motor/Compressor , Setting Of Thermostat , Relay , Knobs , Checking For Any Leakages , Scrap Out Rust And Dust From Body Of Water Cooler Complete All As Specified And Directed . , M & L Cutting , Removing The Old , Rusted Base Angle Iron Frame And Ms Sheets Not Exc 0 . 30 M High Of Chasses Cabinet And S&F Angle Iron And Required Ms Sheet 2 Mm Thick Suitable To The Base Of Storage Type Water Cooler Body Of 40/80/120 Ltr Capacity All Incl

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-06-2021
2 07-Jun-2021 Corrigendum No 1 Date 14-06-2021
3 16-Jun-2021 Corrigendum No 2 Date 21-06-2021
4 23-Jun-2021 No 3 Date 29-06-2021
5 01-Jul-2021 Corrigendum No 4 Date 07-07-2021
6 08-Jul-2021 Corrigendum No 5 Date 16-07-2021
7 17-Jul-2021 Corrigendum No 06 Date 24-07-2021

Key Value

Document Fees
INR 300 /-
EMD
INR 6000.0 /-
Tender Value
INR 3 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail